arXiv:1403.7796 · Review of Scientific Instruments

Shot-noise-limited magnetometer with sub-picotesla sensitivity at room temperature

Vito Giovanni Lucivero, Pawel Anielski, Wojciech Gawlik, Morgan W. Mitchell

Published Nov 1, 2014• 48 citations
arXivHTMLPDF

Abstract

We report a photon shot-noise-limited (SNL) optical magnetometer based on amplitude modulated optical rotation using a room-temperature (85)Rb vapor in a cell with anti-relaxation coating. The instrument achieves a room-temperature sensitivity of 70 fT / √Hz at 7.6 μT. Experimental scaling of noise with optical power, in agreement with theoretical predictions, confirms the SNL behaviour from 5 μT to 75 μT. The combination of best-in-class sensitivity and SNL operation makes the system a promising candidate for application of squeezed light to a state-of-the-art atomic sensor.

DOI
10.1063/1.4901588

Related papers

Vacuum-squeezing-enhanced micrometer-scale vapor-cell magnetometer

Shahar Monsa, Yair Chasid, Michael Shuldiner +2 more

We report on an optical magnetometer enhanced by vacuum-squeezed light, employing an Mx magnetometer based on $^{87}$Rb vapor in a micrometer-scale cell (~100 $μ$m). Using the well-established polarization self-rotation effect in a room-temperature $^{87}$Rb vapor cell, we achieve -3 dB of vacuum squeezing within the noise spectral window of 100 Hz to several MHz, corresponding to 3.5 dB squeezing when accounting for optical losses. Leveraging this level of squeezing, we demonstrate a magnetic field sensitivity of approx. 1 pT$/$$\sqrt{Hz}$. The combination of vacuum-squeezed light and micrometer-scale vapor cells paves the way for compact, low-power-consumption atomic sensors with enhanced performance.

arXiv:2507.07672•Physical Review Applied•Feb 17, 2026•3 citations

Single-Beam Room-Temperature Atomic Magnetometer with Large Bandwidth and Dynamic Range

K. K. George Kurian, Sushree S. Sahoo, Perunthiruthy K. Madhu +1 more

We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the nonlinear regime of magneto-optical rotation of ${}^{85}\mathrm{Rb}$ atomic vapor without any buffer gases. We demonstrate a sensitivity of approximately $0.9\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}$ at 2 kHz and a large bandwidth of 24 kHz. The dynamic range of measurement is ${10}^{6}$, making the sensor effective even in Earth's field. We present the signal-to-noise and bandwidth characteristics of the system for both shielded and unshielded modes of operation. Moreover, we perform theoretical analysis for the atom-light system for the single-laser-beam configuration. The effect of light intensity and detuning on the magnetometer is studied theoretically as well as experimentally to understand the strengths and limitations of the technique.

arXiv:2209.04249•Physical Review Applied•May 11, 2023•13 citations

Detection of radio-frequency magnetic fields using nonlinear magneto-optical rotation

M. P. Ledbetter, Víctor M. Acosta, Simon Rochester +3 more

We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high-frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. Based on experimentally measured signal-to-noise ratio, we demonstrate a sensitivity of $100\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}$ (rms) in a $3.5\text{\ensuremath{-}}\mathrm{cm}$-diameter paraffin coated cell. Assuming detection at the photon shot-noise limit, we project a sensitivity as low as $25\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}$ (rms).

arXiv:physics/0609196•Physical Review A•Feb 8, 2007•66 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Sub-picotesla widely tunable atomic magnetometer operating at room-temperature in unshielded environments

Cameron Deans, Luca Marmugi, Ferruccio Renzoni

We report on a single-channel rubidium radio-frequency atomic magnetometer operating in unshielded environments and near room temperature with a measured sensitivity of 130 fT/Hz. We demonstrate consistent, narrow-bandwidth operation across the kHz–MHz band, corresponding to three orders of magnitude of the magnetic field amplitude. A compensation coil system controlled by a feedback loop actively and automatically stabilizes the magnetic field around the sensor. We measure a reduction in the 50 Hz noise contribution by an order of magnitude. The small effective sensor volume, 57 mm3, increases the spatial resolution of the measurements. Low temperature operation, without any magnetic shielding, coupled with the broad tunability, and low beam power, dramatically extends the range of potential field applications for our device.

arXiv:1804.05124•Review of Scientific Instruments•Aug 1, 2018•46 citations

Light narrowing over broad temperature range with paraffin-coated vapor cells

Shuyuan Chen, Xingqing Jin, Wentian Xiang +4 more

This study reports light narrowing in paraffin-coated vapor cells from room temperature 27 to 59 °C, where spin-exchange relaxation is suppressed. By means of a coating lock and eliminating the reservoir effect, an ultra-narrow magnetic resonance linewidth of 0.36 Hz and an atomic coherence lifetime of T2=0.9 s are achieved. In cells free of buffer gas, the narrow linewidth over this broad temperature range is a result of enhanced spin polarization, which is facilitated by the effective suppression of radiation trapping benefiting from the stability of the vapor density. Using such cells in atomic magnetometers, the photon shot noise limit is estimated as 0.2 fT/Hz1/2 and the spin-projection noise limit is estimated as 1.1 fT/Hz1/2. Also, a magnetometer system with the stable coated cell is identified, which demonstrates the potential for achieving relatively stable magnetometer sensitivity without precisely controlling the cell temperature. The long coherence lifetime and the broad operating temperature range expand the potential applications of quantum memory and other quantum sensors such as atomic clocks.

Journal of Applied Physics•Sep 9, 2024•7 citations
We report a photon shot-noise-limited (SNL) optical magnetometer based on amplitude modulated optical rotation using a room-temperature (85)Rb vapor in a cell with anti-relaxation coating. The instrument achieves a room-temperature sensitivity of 70 fT / √Hz at 7.6 μT. Experimental scaling of noise with optical power, in agreement with theoretical predictions, confirms the SNL behaviour from 5 μT to 75 μT. The combination of best-in-class sensitivity and SNL operation makes the system a promising candidate for application of squeezed light to a state-of-the-art atomic sensor.
We report on an optical magnetometer enhanced by vacuum-squeezed light, employing an Mx magnetometer based on 87^{87}87Rb vapor in a micrometer-scale cell (~100 μμμm). Using the well-established polarization self-rotation effect in a room-temperature 87^{87}87Rb vapor cell, we achieve -3 dB of vacuum squeezing within the noise spectral window of 100 Hz to several MHz, corresponding to 3.5 dB squeezing when accounting for optical losses. Leveraging this level of squeezing, we demonstrate a magnetic field sensitivity of approx. 1 pT///Hz\sqrt{Hz}Hz​. The combination of vacuum-squeezed light and micrometer-scale vapor cells paves the way for compact, low-power-consumption atomic sensors with enhanced performance.
We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the nonlinear regime of magneto-optical rotation of 85Rb{}^{85}\mathrm{Rb}85Rb atomic vapor without any buffer gases. We demonstrate a sensitivity of approximately 0.9pT/Hz0.9\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}0.9pT/Hz​ at 2 kHz and a large bandwidth of 24 kHz. The dynamic range of measurement is 106{10}^{6}106, making the sensor effective even in Earth's field. We present the signal-to-noise and bandwidth characteristics of the system for both shielded and unshielded modes of operation. Moreover, we perform theoretical analysis for the atom-light system for the single-laser-beam configuration. The effect of light intensity and detuning on the magnetometer is studied theoretically as well as experimentally to understand the strengths and limitations of the technique.
We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high-frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. Based on experimentally measured signal-to-noise ratio, we demonstrate a sensitivity of 100pG∕Hz100\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}100pG∕Hz​ (rms) in a $3.5\text{\ensuremath{-}}\mathrm{cm}$-diameter paraffin coated cell. Assuming detection at the photon shot-noise limit, we project a sensitivity as low as 25pG∕Hz25\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}25pG∕Hz​ (rms).
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
We report on a single-channel rubidium radio-frequency atomic magnetometer operating in unshielded environments and near room temperature with a measured sensitivity of 130 fT/Hz. We demonstrate consistent, narrow-bandwidth operation across the kHz–MHz band, corresponding to three orders of magnitude of the magnetic field amplitude. A compensation coil system controlled by a feedback loop actively and automatically stabilizes the magnetic field around the sensor. We measure a reduction in the 50 Hz noise contribution by an order of magnitude. The small effective sensor volume, 57 mm3, increases the spatial resolution of the measurements. Low temperature operation, without any magnetic shielding, coupled with the broad tunability, and low beam power, dramatically extends the range of potential field applications for our device.
This study reports light narrowing in paraffin-coated vapor cells from room temperature 27 to 59 °C, where spin-exchange relaxation is suppressed. By means of a coating lock and eliminating the reservoir effect, an ultra-narrow magnetic resonance linewidth of 0.36 Hz and an atomic coherence lifetime of T2=0.9 s are achieved. In cells free of buffer gas, the narrow linewidth over this broad temperature range is a result of enhanced spin polarization, which is facilitated by the effective suppression of radiation trapping benefiting from the stability of the vapor density. Using such cells in atomic magnetometers, the photon shot noise limit is estimated as 0.2 fT/Hz1/2 and the spin-projection noise limit is estimated as 1.1 fT/Hz1/2. Also, a magnetometer system with the stable coated cell is identified, which demonstrates the potential for achieving relatively stable magnetometer sensitivity without precisely controlling the cell temperature. The long coherence lifetime and the broad operating temperature range expand the potential applications of quantum memory and other quantum sensors such as atomic clocks.