Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

Light narrowing over broad temperature range with paraffin-coated vapor cells

Shuyuan Chen, Xingqing Jin, Wentian Xiang, Wei Xiao, Changping Du, Xiang Peng, Hong Mei Guo

Published Sep 9, 2024• 7 citations
Publisher

Abstract

This study reports light narrowing in paraffin-coated vapor cells from room temperature 27 to 59 °C, where spin-exchange relaxation is suppressed. By means of a coating lock and eliminating the reservoir effect, an ultra-narrow magnetic resonance linewidth of 0.36 Hz and an atomic coherence lifetime of T2=0.9 s are achieved. In cells free of buffer gas, the narrow linewidth over this broad temperature range is a result of enhanced spin polarization, which is facilitated by the effective suppression of radiation trapping benefiting from the stability of the vapor density. Using such cells in atomic magnetometers, the photon shot noise limit is estimated as 0.2 fT/Hz1/2 and the spin-projection noise limit is estimated as 1.1 fT/Hz1/2. Also, a magnetometer system with the stable coated cell is identified, which demonstrates the potential for achieving relatively stable magnetometer sensitivity without precisely controlling the cell temperature. The long coherence lifetime and the broad operating temperature range expand the potential applications of quantum memory and other quantum sensors such as atomic clocks.

DOI
10.1063/5.0230602

Related papers

Is light narrowing possible with dense-vapor paraffin coated cells for atomic magnetometers?

Runqi Han, M. V. Balabas, Chris Hovde +7 more

We investigated the operation of an all-optical rubidium-87 atomic magnetometer with amplitude-modulated light. To study the suppression of spin-exchange relaxation, three schemes of pumping were implemented with room-temperature and heated paraffin coated vacuum cells. Efficient pumping and accumulation of atoms in the F=2 ground state were obtained. However, the sought-for narrowing of the resonance lines has not been achieved. A theoretical analysis of the polarization degree is presented to illustrate the absence of light narrowing due to radiation trapping at high temperature.

AIP Advances•Dec 1, 2017•11 citations

High-temperature alkali vapor cells with antirelaxation surface coatings

Scott J. Seltzer, Michael V. Romalis

Antirelaxation surface coatings allow long spin relaxation times in alkali-metal cells without buffer gas, enabling faster diffusion of the alkali atoms throughout the cell and giving larger signals due to narrower optical linewidths. Effective coatings were previously unavailable for operation at temperatures above 80 °C. We demonstrate that octadecyltrichlorosilane (OTS) can allow potassium or rubidium atoms to experience hundreds of collisions with the cell surface before depolarizing, and that an OTS coating remains effective up to about 170 °C for both potassium and rubidium. We consider the experimental concerns of operating without buffer gas and with minimal quenching gas at high vapor density, studying the stricter need for effective quenching of excited atoms and deriving the optical rotation signal shape for atoms with resolved hyperfine structure in the spin-temperature regime. As an example of a high-temperature application of antirelaxation coated alkali vapor cells, we operate a spin-exchange relaxation-free atomic magnetometer with sensitivity of 6 fT/Hz and magnetic linewidth as narrow as 2 Hz.

arXiv:0906.3054•Journal of Applied Physics•Dec 1, 2009•146 citations

SERF-like magnetometry in room-temperature environment

Guzhi Bao, Jun Chen, Ruiqi Wang +2 more

We demonstrate an atomic magnetometry using amplitude-modulated pumping and hyperfine repumping techniques in a paraffin-coated cell. By exploiting the constructive interference between spins polarized by the pump beam and an additional repump beam, we observe a three-fold increase in the amplitude of magnetic resonance, along with a reduction in linewidth by approximately two times. The implementation of the repump beam effectively narrows the linewidth, demonstrating successful suppression of spin-exchange relaxation. This reduction in relaxation rate, combined with the enhanced signal, significantly improves the sensitivity of the magnetometer. Consequently, our technique offers a promising approach for achieving SERF-like magnetometry with sub-fT-level sensitivity in Earth-field range and room-temperature environment.

Optics Express•Sep 19, 2023•6 citations

The Characterization of Atomic Vapor Cells for High-Sensitivity Magnetic Field Measurements in SERF Regime

Murat Salim Karabinaoğlu, Berfin Muhlise Caklı, Mehmet Hüseyin Sevim

Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.

IEEE Sensors Letters•Feb 24, 2025•5 citations

Spin-exchange-relaxation-free magnetometry with Cs vapor

M. P. Ledbetter, Igor Savukov, Víctor M. Acosta +2 more

We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\text{ }\text{pG}/\sqrt{\text{Hz}}$. Based on photon shot noise, we project a sensitivity of $40\text{ }\text{pG}/\sqrt{\text{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2\text{ }\text{pG}/\sqrt{\text{Hz}}$ should be achievable in a $1\text{ }{\text{cm}}^{3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

arXiv:0708.1012•Physical Review A•Mar 13, 2008•408 citations

Characterization of high-temperature performance of cesium vapor cells with anti-relaxation coating

Wenhao Li, M. V. Balabas, Xiang Peng +4 more

Vapor cells with antirelaxation coating are widely used in modern atomic physics experiments due to the coating's ability to maintain the atoms' spin polarization during wall collisions. We characterize the performance of vapor cells with different coating materials by measuring longitudinal spin relaxation and vapor density at temperatures up to 95 °C. We infer that the spin-projection-noise-limited sensitivity for atomic magnetometers with such cells improves with temperature, which demonstrates the potential of antirelaxation coated cells in applications of future high-sensitivity magnetometers.

arXiv:1609.04867•Journal of Applied Physics•Feb 13, 2017•46 citations
This study reports light narrowing in paraffin-coated vapor cells from room temperature 27 to 59 °C, where spin-exchange relaxation is suppressed. By means of a coating lock and eliminating the reservoir effect, an ultra-narrow magnetic resonance linewidth of 0.36 Hz and an atomic coherence lifetime of T2=0.9 s are achieved. In cells free of buffer gas, the narrow linewidth over this broad temperature range is a result of enhanced spin polarization, which is facilitated by the effective suppression of radiation trapping benefiting from the stability of the vapor density. Using such cells in atomic magnetometers, the photon shot noise limit is estimated as 0.2 fT/Hz1/2 and the spin-projection noise limit is estimated as 1.1 fT/Hz1/2. Also, a magnetometer system with the stable coated cell is identified, which demonstrates the potential for achieving relatively stable magnetometer sensitivity without precisely controlling the cell temperature. The long coherence lifetime and the broad operating temperature range expand the potential applications of quantum memory and other quantum sensors such as atomic clocks.
We investigated the operation of an all-optical rubidium-87 atomic magnetometer with amplitude-modulated light. To study the suppression of spin-exchange relaxation, three schemes of pumping were implemented with room-temperature and heated paraffin coated vacuum cells. Efficient pumping and accumulation of atoms in the F=2 ground state were obtained. However, the sought-for narrowing of the resonance lines has not been achieved. A theoretical analysis of the polarization degree is presented to illustrate the absence of light narrowing due to radiation trapping at high temperature.
Antirelaxation surface coatings allow long spin relaxation times in alkali-metal cells without buffer gas, enabling faster diffusion of the alkali atoms throughout the cell and giving larger signals due to narrower optical linewidths. Effective coatings were previously unavailable for operation at temperatures above 80 °C. We demonstrate that octadecyltrichlorosilane (OTS) can allow potassium or rubidium atoms to experience hundreds of collisions with the cell surface before depolarizing, and that an OTS coating remains effective up to about 170 °C for both potassium and rubidium. We consider the experimental concerns of operating without buffer gas and with minimal quenching gas at high vapor density, studying the stricter need for effective quenching of excited atoms and deriving the optical rotation signal shape for atoms with resolved hyperfine structure in the spin-temperature regime. As an example of a high-temperature application of antirelaxation coated alkali vapor cells, we operate a spin-exchange relaxation-free atomic magnetometer with sensitivity of 6 fT/Hz and magnetic linewidth as narrow as 2 Hz.
We demonstrate an atomic magnetometry using amplitude-modulated pumping and hyperfine repumping techniques in a paraffin-coated cell. By exploiting the constructive interference between spins polarized by the pump beam and an additional repump beam, we observe a three-fold increase in the amplitude of magnetic resonance, along with a reduction in linewidth by approximately two times. The implementation of the repump beam effectively narrows the linewidth, demonstrating successful suppression of spin-exchange relaxation. This reduction in relaxation rate, combined with the enhanced signal, significantly improves the sensitivity of the magnetometer. Consequently, our technique offers a promising approach for achieving SERF-like magnetometry with sub-fT-level sensitivity in Earth-field range and room-temperature environment.
Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.
We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about 400 pG/Hz400\text{ }\text{pG}/\sqrt{\text{Hz}}400 pG/Hz​. Based on photon shot noise, we project a sensitivity of 40 pG/Hz40\text{ }\text{pG}/\sqrt{\text{Hz}}40 pG/Hz​. A theoretical optimization of the magnetometer indicates sensitivities on the order of 2 pG/Hz2\text{ }\text{pG}/\sqrt{\text{Hz}}2 pG/Hz​ should be achievable in a 1 cm31\text{ }{\text{cm}}^{3}1 cm3 volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.
Vapor cells with antirelaxation coating are widely used in modern atomic physics experiments due to the coating's ability to maintain the atoms' spin polarization during wall collisions. We characterize the performance of vapor cells with different coating materials by measuring longitudinal spin relaxation and vapor density at temperatures up to 95 °C. We infer that the spin-projection-noise-limited sensitivity for atomic magnetometers with such cells improves with temperature, which demonstrates the potential of antirelaxation coated cells in applications of future high-sensitivity magnetometers.