Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1306.4768 · Physical Review Letters

Phase Estimation with Weak Measurement Using a White Light Source

Xiao-Ye Xu, Yaron Kedem, Kai Sun, Lev Vaidman A, Chuan-Feng Li, Guang‐Can Guo

Published Jul 17, 2013• 301 citations
arXivHTMLPDF

Abstract

We report results of a high precision phase estimation based on a weak measurement scheme using a commercial light-emitting diode. The method is based on a measurement of the imaginary part of the weak value of a polarization operator. The imaginary part of the weak value appeared due to the measurement interaction itself. The sensitivity of our method is equivalent to resolving light pulses of the order of a attosecond and it is robust against chromatic dispersion.

DOI
10.1103/physrevlett.111.033604

Related papers

Precision phase estimation based on weak-value amplification

Xiaodong Qiu, Linguo Xie, Xiong Liu +4 more

In this letter, we propose a precision method for phase estimation based on the weak-value amplification (WVA) technique using a monochromatic light source. The anomalous WVA significantly suppresses the technical noise with respect to the intensity difference signal induced by the phase delay when the post-selection procedure comes into play. The phase measured precision of this method is proportional to the weak-value of a polarization operator in the experimental range. Our results compete well with the wide spectrum light phase weak measurements and outperform the standard homodyne phase detection technique.

Applied Physics Letters•Feb 13, 2017•101 citations

Simultaneously precise estimations of phase and amplitude variations based on weak-value amplification

Lan E Luo, Linguo Xie, Jiangdong Qiu +6 more

In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.

Applied Physics Letters•Mar 18, 2019•27 citations

Precision estimation of time delay based on weak measurement with real weak value

Weining Liu, Yisen Wang, Hailu Luo

In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.

Physical Review A•Nov 13, 2023•5 citations

Phase estimation based on inverse weak-value using a monochromatic light source

Shiwei Xie, Zhaoxue Li, Yan Liu +1 more

Weak-value measurement (WVM) technique, especially the linear WVM technique, has been proved to be useful in high precision metrology. However, the phase shift to be measured is strictly dominated by the input meter, such as the light wavelength and the space position, which are the basic elements of the linear WVM regime. In this work, an inverse WVM technique using a monochromatic light source is presented to achieve precise estimation of the wavelength-independent phase shift. The theoretical analysis in sensitivity and precision indicates that the inverse WVM technique is more applicable to wavelength-independent phase estimation, as compared to the typical linear WVM technique. Furthermore, two possible experimental designs based on the inverse WVM technique are proposed, which may promote the practical applications of this technique in precision metrology.

Applied Physics Express•Nov 14, 2019•4 citations

Noise mitigation for high-sensitivity phase estimation based on weak measurements

Xiaorui Tan, Hongjing Li, Qi Song +6 more

Phase estimation has attracted much attention in the field of sensing, where weak measurement has become an effective solution for the study of small physical quantities because of its anomalous amplification property. However, it is difficult for weak measurement to cope with large low-frequency noise signals in the environment due to its extremely narrow linear range, which makes the extension of weak measurement to practical applications a challenging task. In order to solve this issue, we propose and experimentally verify a phase demodulation scheme based on weak measurement, which solves the problem of working point offset caused by the noise through artificially introducing a high-frequency carrier and performing demodulation operations on the output light. The experimental results show that the scheme can improve the signal-to-noise ratio by 17 dB compared to standard weak measurement and ensures low distortion in phase demodulation. Moreover, the scheme is not limited to a specific modulation depth, which greatly improves the robustness of the scheme.

Physical Review A•May 8, 2024•3 citations

Ultrasensitive phase estimation with white light

Chuan‐Feng Li, Xiao-Ye Xu, Jian‐Shun Tang +2 more

An improvement of the scheme by Brunner and Simon [Phys. Rev. Lett. 105, 010405 (2010)] is proposed in order to show that quantum weak measurements can provide a method to detect ultrasmall longitudinal phase shifts, even with white light. By performing an analysis in the frequency domain, we find that the amplification effect will work as long as the spectrum is large enough, irrespective of the behavior in the time domain. As such, the previous scheme can be notably simplified for experimental implementations.

arXiv:1102.4902•Physical Review A•Apr 19, 2011•63 citations
We report results of a high precision phase estimation based on a weak measurement scheme using a commercial light-emitting diode. The method is based on a measurement of the imaginary part of the weak value of a polarization operator. The imaginary part of the weak value appeared due to the measurement interaction itself. The sensitivity of our method is equivalent to resolving light pulses of the order of a attosecond and it is robust against chromatic dispersion.
In this letter, we propose a precision method for phase estimation based on the weak-value amplification (WVA) technique using a monochromatic light source. The anomalous WVA significantly suppresses the technical noise with respect to the intensity difference signal induced by the phase delay when the post-selection procedure comes into play. The phase measured precision of this method is proportional to the weak-value of a polarization operator in the experimental range. Our results compete well with the wide spectrum light phase weak measurements and outperform the standard homodyne phase detection technique.
In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.
In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.
Weak-value measurement (WVM) technique, especially the linear WVM technique, has been proved to be useful in high precision metrology. However, the phase shift to be measured is strictly dominated by the input meter, such as the light wavelength and the space position, which are the basic elements of the linear WVM regime. In this work, an inverse WVM technique using a monochromatic light source is presented to achieve precise estimation of the wavelength-independent phase shift. The theoretical analysis in sensitivity and precision indicates that the inverse WVM technique is more applicable to wavelength-independent phase estimation, as compared to the typical linear WVM technique. Furthermore, two possible experimental designs based on the inverse WVM technique are proposed, which may promote the practical applications of this technique in precision metrology.
Phase estimation has attracted much attention in the field of sensing, where weak measurement has become an effective solution for the study of small physical quantities because of its anomalous amplification property. However, it is difficult for weak measurement to cope with large low-frequency noise signals in the environment due to its extremely narrow linear range, which makes the extension of weak measurement to practical applications a challenging task. In order to solve this issue, we propose and experimentally verify a phase demodulation scheme based on weak measurement, which solves the problem of working point offset caused by the noise through artificially introducing a high-frequency carrier and performing demodulation operations on the output light. The experimental results show that the scheme can improve the signal-to-noise ratio by 17 dB compared to standard weak measurement and ensures low distortion in phase demodulation. Moreover, the scheme is not limited to a specific modulation depth, which greatly improves the robustness of the scheme.
An improvement of the scheme by Brunner and Simon [Phys. Rev. Lett. 105, 010405 (2010)] is proposed in order to show that quantum weak measurements can provide a method to detect ultrasmall longitudinal phase shifts, even with white light. By performing an analysis in the frequency domain, we find that the amplification effect will work as long as the spectrum is large enough, irrespective of the behavior in the time domain. As such, the previous scheme can be notably simplified for experimental implementations.