Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1102.4902 · Physical Review A

Ultrasensitive phase estimation with white light

Chuan‐Feng Li, Xiao-Ye Xu, Jian‐Shun Tang, Jin‐Shi Xu, Guang‐Can Guo

Published Apr 19, 2011• 63 citations
arXivHTMLPDF

Abstract

An improvement of the scheme by Brunner and Simon [Phys. Rev. Lett. 105, 010405 (2010)] is proposed in order to show that quantum weak measurements can provide a method to detect ultrasmall longitudinal phase shifts, even with white light. By performing an analysis in the frequency domain, we find that the amplification effect will work as long as the spectrum is large enough, irrespective of the behavior in the time domain. As such, the previous scheme can be notably simplified for experimental implementations.

DOI
10.1103/physreva.83.044102

Related papers

Ultrasensitive biased weak measurement for longitudinal phase estimation

Zi-Huai Zhang, Geng Chen, Xiao-Ye Xu +5 more

Standard weak measurement (SWM) has been proved to be a useful ingredient for measuring small longitudinal phase change (LPC) [X. Y. Xu, Y. Kedem, K. Sun, L. Vaidman, C. F. Li, and Guang-Can Guo, Phys. Rev. Lett. 111, 033604 (2013)]. In these SWM proposals, the working regime is selected where the relative phase between orthogonal components is zero, and the LPC can be detected by measuring the shift of the meter state, i.e., the time and frequency domain, which are conjugated observables. Here, we show that an extra bias phase can significantly improve the sensitivity of measuring LPC. This bias phase can be introduced by a precoupling process. Together with a special postselection, a destructive interference can be observed in both the time and frequency domain. Using a broadband source, this conjugated destructive interference occurs in a regime less than 1 as, while the related spectral shift reaches hundreds of THz, resulting in sensitivity outperforming SWM by two orders of magnitude.

Physical Review A•Nov 22, 2016•40 citations

Measuring Small Longitudinal Phase Shifts: Weak Measurements or Standard Interferometry?

Nicolas Brunner, Christoph Simon

Recently, weak measurements were used to measure small effects that are transverse to the propagation direction of a light beam. Here we address the question of whether weak measurements are also useful for measuring small longitudinal phase shifts. We show that standard interferometry greatly outperforms weak measurements in a scenario involving a purely real weak value. However, we also present an interferometric scheme based on a purely imaginary weak value, combined with a frequency-domain analysis, which may have the potential to outperform standard interferometry by several orders of magnitude.

arXiv:0911.5139•Physical Review Letters•Jul 2, 2010•395 citations

Measuring Ultrasmall Time Delays of Light by Joint Weak Measurements

Grégory Strübi, Christoph Bruder

We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.

arXiv:1301.5846•Physical Review Letters•Feb 22, 2013•135 citations

Toward ultrahigh sensitivity in weak-value amplification

Jingzheng Huang, Yanjia Li, Chen Fang +2 more

Achieving higher sensitivity is an earnest purpose for precision metrology. As a response to this goal, the weak-value amplification approach has been developed for measuring ultrasmall physical effects, realizing sensitivity that had never been reached before. Encouraged by the successes, many efforts have been devoted to obtain ultimate sensitivity of weak-value amplification. However, the benefit would be easily compromised in practice, because the cost of significant reduction on signal intensity leads to an ultralow signal-to-noise ratio. In this work, we bridge this gap by proposing an alternative weak-value amplification approach, which provides sensitivity several orders of magnitude higher than the standard approach while being compatible with practical imperfections. In the proof-of-principle experiment of measuring longitudinal phase change in time domain, sensitivity up to $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ attosecond is exemplified. Our approach can be applied to measure other small parameters with extremely high sensitivity, providing a method for future precision metrology.

arXiv:1907.02168•Physical Review A•Jul 11, 2019•40 citations

Phase Estimation with Weak Measurement Using a White Light Source

Xiao-Ye Xu, Yaron Kedem, Kai Sun +3 more

We report results of a high precision phase estimation based on a weak measurement scheme using a commercial light-emitting diode. The method is based on a measurement of the imaginary part of the weak value of a polarization operator. The imaginary part of the weak value appeared due to the measurement interaction itself. The sensitivity of our method is equivalent to resolving light pulses of the order of a attosecond and it is robust against chromatic dispersion.

arXiv:1306.4768•Physical Review Letters•Jul 17, 2013•301 citations

Experimental Ultra-small Longitudinal Phase Estimation via Weak Measurement Amplification

Mengjun Hu, Xiao‐Min Hu, Bi‐Heng Liu +4 more

Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.

•Jan 1, 2018•2 citations
An improvement of the scheme by Brunner and Simon [Phys. Rev. Lett. 105, 010405 (2010)] is proposed in order to show that quantum weak measurements can provide a method to detect ultrasmall longitudinal phase shifts, even with white light. By performing an analysis in the frequency domain, we find that the amplification effect will work as long as the spectrum is large enough, irrespective of the behavior in the time domain. As such, the previous scheme can be notably simplified for experimental implementations.
Standard weak measurement (SWM) has been proved to be a useful ingredient for measuring small longitudinal phase change (LPC) [X. Y. Xu, Y. Kedem, K. Sun, L. Vaidman, C. F. Li, and Guang-Can Guo, Phys. Rev. Lett. 111, 033604 (2013)]. In these SWM proposals, the working regime is selected where the relative phase between orthogonal components is zero, and the LPC can be detected by measuring the shift of the meter state, i.e., the time and frequency domain, which are conjugated observables. Here, we show that an extra bias phase can significantly improve the sensitivity of measuring LPC. This bias phase can be introduced by a precoupling process. Together with a special postselection, a destructive interference can be observed in both the time and frequency domain. Using a broadband source, this conjugated destructive interference occurs in a regime less than 1 as, while the related spectral shift reaches hundreds of THz, resulting in sensitivity outperforming SWM by two orders of magnitude.
Recently, weak measurements were used to measure small effects that are transverse to the propagation direction of a light beam. Here we address the question of whether weak measurements are also useful for measuring small longitudinal phase shifts. We show that standard interferometry greatly outperforms weak measurements in a scenario involving a purely real weak value. However, we also present an interferometric scheme based on a purely imaginary weak value, combined with a frequency-domain analysis, which may have the potential to outperform standard interferometry by several orders of magnitude.
We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.
Achieving higher sensitivity is an earnest purpose for precision metrology. As a response to this goal, the weak-value amplification approach has been developed for measuring ultrasmall physical effects, realizing sensitivity that had never been reached before. Encouraged by the successes, many efforts have been devoted to obtain ultimate sensitivity of weak-value amplification. However, the benefit would be easily compromised in practice, because the cost of significant reduction on signal intensity leads to an ultralow signal-to-noise ratio. In this work, we bridge this gap by proposing an alternative weak-value amplification approach, which provides sensitivity several orders of magnitude higher than the standard approach while being compatible with practical imperfections. In the proof-of-principle experiment of measuring longitudinal phase change in time domain, sensitivity up to $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ attosecond is exemplified. Our approach can be applied to measure other small parameters with extremely high sensitivity, providing a method for future precision metrology.
Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.