Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1112.2766 · Physical Review Letters

High-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock

Jeff A. Sherman, N. Lemke, N. Hinkley, Marco Pizzocaro, Richard W. Fox, Andrew D. Ludlow, Chris W. Oates

Published Apr 13, 2012• 137 citations
arXivHTMLPDF

Abstract

Presently, the Stark effect contributes the largest source of uncertainty in a ytterbium optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels ${\ensuremath{\alpha}}_{\mathrm{clock}}=36.2612(7)\text{ }\text{ }\mathrm{kHz}\text{ }(\mathrm{kV}/\mathrm{cm}{)}^{\ensuremath{-}2}$. The clock's uncertainty due to room temperature blackbody radiation is reduced by an order of magnitude to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$.

DOI
10.1103/physrevlett.108.153002

Related papers

Polarizability of an optical lattice clock at 20 ppm

Jeff A. Sherman, N. Lemke, N. Hinkley +3 more

Optical lattice clocks, which are based on highly-forbidden1S0↔3P0transitions of ultracold alkaline-earth atoms confined in standing-wave optical potentials [1], offer exquisite frequency stability and uncertainty. We leverage these advantages to determine the sensitivity of a ytterbium optical lattice clock to external electric fields at 20 part-per-million (ppm) accuracy [2]. We describe an electrode design compatible with various neutral optical atomic clocks and capable of absolute electric field generation at the ppm level. Importantly, the result bounds the uncertainty of the ytterbium clock frequency due to room-temperature blackbody radiation at the level of 3×10-17.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations

Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty

K. Beloy, N. Hinkley, Nate Phillips +7 more

The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.

arXiv:1412.1029•Physical Review Letters•Dec 24, 2014•145 citations

Determination of the 5d6s 3D1 state lifetime and blackbody-radiation clock shift in Yb

K. Beloy, Jeff A. Sherman, N. Lemke +3 more

The Stark shift of the ytterbium (Yb) optical clock transition due to room-temperature blackbody radiation is dominated by a static Stark effect, which was recently measured to high accuracy [J. A. Sherman et al., Phys. Rev. Lett. 108, 153002 (2012)]. However, room-temperature realization of the clock at ${10}^{\ensuremath{-}18}$ uncertainty requires a dynamic contribution to this static approximation. This dynamic term largely depends on a single electric dipole matrix element for which theoretically and experimentally derived values disagree significantly. We determine this important matrix element by two independent methods, which yield consistent values. Along with precise radiative lifetimes of $6s6p\phantom{\rule{0.16em}{0ex}}{}^{3}\phantom{\rule{-0.16em}{0ex}}{P}_{1}^{}$ and $5d6s\phantom{\rule{0.16em}{0ex}}{}^{3}\phantom{\rule{-0.16em}{0ex}}{D}_{1}^{}$, we report the clock shift due to an ideal 300 K blackbody environment to 0.05$%$ precision.

arXiv:1208.0552•Physical Review A•Nov 29, 2012•71 citations

Measurement of the differential polarizability of the 698 nm clock transition of strontium for evaluation of optical lattice clocks

Thomas Middelmann, Stephan Falke, Christian Lisdat +1 more

A modification to a successfull technique to measure static differential polarizabilities of ultracold atoms and molecules is presented. Ultracold atoms are trapped in a magic wavelength optical lattice and transported into the field of a precision capacitor. The change of the transition frequency induced by the applied field, which is controlled to better than 10-4, is measured. For atomic clocks, the difference of the static polarizabilies of ground and excited state is closely related to their response to a blackbody radiation field, which is a significant contribution to the uncertainty budget of many atomic clocks.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations

Measurement of radiative decay and cold collision trap losses in laser-cooled Ytterbium

Marco Zoppi, Giovanni Antonio Costanzo, Marco Pizzocaro +5 more

Ytterbium lattice frequency standard is an outstanding optical clock with a demonstrated relative frequency accuracy of 3.4·10-16, presently limited by the uncertainty on the blackbody radiation (BBR), lattice polarizabilities and cold collisions shifts. In particular the BBR shift is looming as a major component in the uncertainty budget of many optical frequency standards. In fact the uncertainty on BBR systematic shift in Ytterbium atoms is due both to experimental and theoretical limits in the knowledge of the atomic system: presently Ytterbium has the largest theoretical uncertainty on the BBR shift. Then, both for atomic physics and metrology, new measurements of the Ytterbium atomic properties are strongly demanded, such as the determination of transition matrix elements, lifetimes, branching ratios, polarizabilities and hyperfine constants. In this work we present a set of new measurements for the radiative decay and for the cold collisions trap losses in laser-cooled Ytterbium atoms. These data are relevant to the blackbody radiation shift evaluation and to the cold collisions shift theory.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•0 citations

Optical Lattice Clock with Spin-1/2 Ytterbium Atoms

N. Lemke

An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.

•Jan 1, 2012•7 citations
Presently, the Stark effect contributes the largest source of uncertainty in a ytterbium optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels \ensuremathαclock=36.2612(7)  kHz (kV/cm)\ensuremath−2{\ensuremath{\alpha}}_{\mathrm{clock}}=36.2612(7)\text{ }\text{ }\mathrm{kHz}\text{ }(\mathrm{kV}/\mathrm{cm}{)}^{\ensuremath{-}2}\ensuremathαclock​=36.2612(7)  kHz (kV/cm)\ensuremath−2. The clock's uncertainty due to room temperature blackbody radiation is reduced by an order of magnitude to 3\ifmmode×\else\texttimes\fi10\ensuremath−173\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}3\ifmmode×\else\texttimes\fi10\ensuremath−17.
Optical lattice clocks, which are based on highly-forbidden1S0↔3P0transitions of ultracold alkaline-earth atoms confined in standing-wave optical potentials [1], offer exquisite frequency stability and uncertainty. We leverage these advantages to determine the sensitivity of a ytterbium optical lattice clock to external electric fields at 20 part-per-million (ppm) accuracy [2]. We describe an electrode design compatible with various neutral optical atomic clocks and capable of absolute electric field generation at the ppm level. Importantly, the result bounds the uncertainty of the ytterbium clock frequency due to room-temperature blackbody radiation at the level of 3×10-17.
The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.
The Stark shift of the ytterbium (Yb) optical clock transition due to room-temperature blackbody radiation is dominated by a static Stark effect, which was recently measured to high accuracy [J. A. Sherman et al., Phys. Rev. Lett. 108, 153002 (2012)]. However, room-temperature realization of the clock at ${10}^{\ensuremath{-}18}$ uncertainty requires a dynamic contribution to this static approximation. This dynamic term largely depends on a single electric dipole matrix element for which theoretically and experimentally derived values disagree significantly. We determine this important matrix element by two independent methods, which yield consistent values. Along with precise radiative lifetimes of 6s6p3P16s6p\phantom{\rule{0.16em}{0ex}}{}^{3}\phantom{\rule{-0.16em}{0ex}}{P}_{1}^{}6s6p3P1​ and 5d6s3D15d6s\phantom{\rule{0.16em}{0ex}}{}^{3}\phantom{\rule{-0.16em}{0ex}}{D}_{1}^{}5d6s3D1​, we report the clock shift due to an ideal 300 K blackbody environment to 0.05% precision.
A modification to a successfull technique to measure static differential polarizabilities of ultracold atoms and molecules is presented. Ultracold atoms are trapped in a magic wavelength optical lattice and transported into the field of a precision capacitor. The change of the transition frequency induced by the applied field, which is controlled to better than 10-4, is measured. For atomic clocks, the difference of the static polarizabilies of ground and excited state is closely related to their response to a blackbody radiation field, which is a significant contribution to the uncertainty budget of many atomic clocks.
Ytterbium lattice frequency standard is an outstanding optical clock with a demonstrated relative frequency accuracy of 3.4·10-16, presently limited by the uncertainty on the blackbody radiation (BBR), lattice polarizabilities and cold collisions shifts. In particular the BBR shift is looming as a major component in the uncertainty budget of many optical frequency standards. In fact the uncertainty on BBR systematic shift in Ytterbium atoms is due both to experimental and theoretical limits in the knowledge of the atomic system: presently Ytterbium has the largest theoretical uncertainty on the BBR shift. Then, both for atomic physics and metrology, new measurements of the Ytterbium atomic properties are strongly demanded, such as the determination of transition matrix elements, lifetimes, branching ratios, polarizabilities and hyperfine constants. In this work we present a set of new measurements for the radiative decay and for the cold collisions trap losses in laser-cooled Ytterbium atoms. These data are relevant to the blackbody radiation shift evaluation and to the cold collisions shift theory.
An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.