Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0804.4589 · Applied Physics B

Loading of large ion Coulomb crystals into a linear Paul trap incorporating an optical cavity

Peter F. Herskind, Aurélien Dantan, M. B. Langkilde-Lauesen, A. Mortensen, Jens Lykke Sørensen, Michael Drewsen

Published Sep 12, 2008• 37 citations
arXivHTMLPDF
DOI
10.1007/s00340-008-3199-8

Related papers

Single- and Multispecies ion coulomb crystals in linear Paul traps

Michael Drewsen

•Jan 1, 2003•0 citations

Linear Paul trap design for an optical clock with Coulomb crystals

N. Herschbach, K. Pyka, J. Keller +1 more

arXiv:1109.6152•Applied Physics B•Nov 16, 2011•81 citations

Laser-assisted phase transitions in ion Coulomb crystals in Paul traps

Anna Romanova, Yuri Rozhdestvensky

Optical and Quantum Electronics•Apr 17, 2026•0 citations

Optical Rotation of Few-Ion Crystals in a Linear Paul Trap

Arpita Pal, Viet Le Duc, Akira Ozawa +2 more

Bulletin of the American Physical Society•Jun 3, 2021•0 citations

Realization of collective strong coupling with ion Coulomb crystals in an optical cavity

Peter F. Herskind, Aurélien Dantan, Joan P. Marler +2 more

Nature Physics•Jun 7, 2009•165 citations

Positioning of the rf potential minimum line of a linear Paul trap with micrometer precision

Peter F. Herskind, Aurélien Dantan, Magnus Albert +2 more

We demonstrate a general technique to achieve a precise radial displacement of the nodal line of the radiofrequency (rf) field in a linear Paul trap. The technique relies on selective adjustment of the load capacitance of the trap electrodes, achieved through the addition of capacitors to the basic resonant rf-circuit used to drive the trap. Displacements of up to 100 micrometer with micrometer precision are measured using a combination of fluorescence images of ion Coulomb crystals and coherent coupling of such crystals to a mode of an optical cavity. The displacements are made without measurable distortion of the shape or structure of the Coulomb crystals, as well as without introducing excess heating commonly associated with the radial displacement of crystals by adjustment through static potentials. We expect this technique to be of importance for future developments of microtrap architectures and ion-based cavity QED.

arXiv:0905.3147•Journal of Physics B Atomic Molecular and Optical Physics•Jul 15, 2009•39 citations
We demonstrate a general technique to achieve a precise radial displacement of the nodal line of the radiofrequency (rf) field in a linear Paul trap. The technique relies on selective adjustment of the load capacitance of the trap electrodes, achieved through the addition of capacitors to the basic resonant rf-circuit used to drive the trap. Displacements of up to 100 micrometer with micrometer precision are measured using a combination of fluorescence images of ion Coulomb crystals and coherent coupling of such crystals to a mode of an optical cavity. The displacements are made without measurable distortion of the shape or structure of the Coulomb crystals, as well as without introducing excess heating commonly associated with the radial displacement of crystals by adjustment through static potentials. We expect this technique to be of importance for future developments of microtrap architectures and ion-based cavity QED.