Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0603248 · Physical Review Letters

Benchmarking Quantum Control Methods on a 12-Qubit System

C. Negrevergne, T. S. Mahesh, Colm A. Ryan, Michael J. T. Ditty, Francis-Yan Cyr-Racine, William P. Power, Nicolas Boulant, Timothy F. Havel, David G. Cory, Raymond Laflamme

Published May 1, 2006• 206 citations
arXivHTMLPDF

Abstract

In this Letter, we present an experimental benchmark of operational control methods in quantum information processors extended up to 12 qubits. We implement universal control of this large Hilbert space using two complementary approaches and discuss their accuracy and scalability. Despite decoherence, we were able to reach a 12-coherence state (or a 12-qubit pseudopure cat state) and decode it into an 11 qubit plus one qutrit pseudopure state using liquid state nuclear magnetic resonance quantum information processors.

DOI
10.1103/physrevlett.96.170501

Related papers

Liquid-state nuclear magnetic resonance as a testbed for developing quantum control methods

Colm A. Ryan, C. Negrevergne, Martin Laforest +2 more

In building a quantum-information processor (QIP), the challenge is to coherently control a large quantum system well enough to perform an arbitrary quantum algorithm and to be able to correct errors induced by decoherence. Nuclear magnetic resonance (NMR) QIPs offer an excellent testbed on which to develop and benchmark tools and techniques to control quantum systems. Two main issues to consider when designing control methods are accuracy and efficiency, for which two complementary approaches have been developed so far to control qubit registers with liquid-state NMR methods. The first applies optimal control theory to numerically optimize the control fields to implement unitary operations on low-dimensional systems with high fidelity. The second technique is based on the efficient optimization of a sequence of imperfect control elements so that implementation of a full quantum algorithm is possible while minimizing error accumulation. This paper summarizes our work in implementing both of these methods. Furthermore, we show that taken together, they form a basis to design quantum control methods for a block-architecture QIP so that large system size is not a barrier to implementing optimal control techniques.

arXiv:0803.1982•Physical Review A•Jul 15, 2008•143 citations

A Cat-State Benchmark on a Seven Bit Quantum Computer

Emanuel H. Knill, Raymond Laflamme, R. M. Martinez +1 more

We propose and experimentally realize an algorithmic benchmark that demonstrates coherent control with a sequence of quantum operations that first generates and then decodes the cat state (|000...>+|111...>)/sqrt(2) to the standard initial state |000...>. This is the first high fidelity experimental quantum algorithm on the currently largest physical quantum register, which has seven quantum bits (qubits) provided by the nuclei of crotonic acid. The experiment has the additional benefit of verifying a seven coherence in a generic system of coupled spins. Our implementation combines numerous nuclear magnetic resonance (NMR) techniques in one experiment and introduces practical methods for translating quantum networks to control operations. The experimental procedure can be used as a reliable and efficient method for creating a standard pseudo-pure state, the first step for implementing traditional quantum algorithms in liquid state NMR. The benchmark and the techniques can be adapted for use on other proposed quantum devices.

arXiv:quant-ph/9908051•Aug 15, 1999•25 citations

Randomized benchmarking of single- and multi-qubit control in liquid-state NMR quantum information processing

Colm A. Ryan, M Laforest, R Laflamme

Being able to quantify the level of coherent control in a proposed device implementing a quantum information processor (QIP) is an important task for both comparing different devices and assessing a device's prospects with regards to achieving fault-tolerant quantum control. We implement in a liquid-state nuclear magnetic resonance QIP the randomized benchmarking protocol presented by Knill et al (2008 Phys. Rev. A 77 012307). We report an error per randomized π/2 pulse of 1.3±0.1 × 10 −4 with a single-qubit QIP and show an experimentally relevant error model where the randomized benchmarking gives a signature fidelity decay which is not possible to interpret as a single error per gate. We explore and experimentally investigate multi-qubit extensions of this protocol and report an average error rate for one- and two-qubit gates of 4.7±0.3 × 10 −3 for a three-qubit QIP. We estimate that these error rates are still not decoherence limited and thus can be improved with modifications to the control hardware and software.

arXiv:0808.3973•New Journal of Physics•Jan 23, 2009•125 citations

Entanglement transfer experiment in NMR quantum information processing

Nicolas Boulant, Evan M. Fortunato, Marco A. Pravia +3 more

We report the implementation of an entanglement transfer on a four-qubit liquid-state nuclear-magnetic resonance quantum information processor. This consists of creating an (pseudopure) entangled state among two directly coupled spins, and then transferring this two-spin state to another pair of spins whose direct interactions are negligible. Such transfers are expected to be an essential operation in scalable quantum computer architectures, and provide a useful benchmark for the coherent control available in specific implementations.

Physical Review A•Jan 10, 2002•27 citations

Experimental demonstration of an entanglement swapping operation and improved control in NMR quantum-information processing

Nicolas Boulant, Karina Montilla Edmonds, Jerry Zhijian Yang +2 more

We demonstrate the implementation of an entanglement swapping operation on a four-qubit liquid-state nuclear-magnetic-resonance (NMR) quantum-information processor. We use this experiment as a benchmark to illustrate the progress made in the field of quantum control using strongly modulating pulses and a correction scheme for removing distortions introduced by the nonlinearities in the transmitter and probe circuits. The advances include compensating for incoherent errors caused by the spatial variation of the system Hamiltonian in the NMR sample. The goal of these control sequences is to cause the collapse of the Kraus operator-sum representation of the superoperator into one unitary operator so that the ensemble appears to evolve as one coherent whole.

Physical Review A•Sep 11, 2003•36 citations

Using Nuclear Magnetic Resonance to Assess and Optimize the Precision of Methods for Controlling Quantum Dynamics

David G. Cory, Timothy F. Havel

The most significant achievements of this project were: (1) Development and validation of the hardware and software needed to implement "strongly modulating pulses", by which high precision quantum gates can be obtain in realistic systems of up to 12 qubits; (2) A detailed analysis and evaluation of a 3-qubit quantum Fourier transform via full quantum process tomography; (3) An extensive set of mathematical and computational techniques to accomplish these goals, including Hadamard products, the real density matrix, and methods of fitting superoperators to experimental data; (4) Creation of a 3-qubit "noiseless subsystem", of a Bell state on two 2-qubit decoherence-free subspaces (DFS), and the invention of "partial" pseudopure states which will enable us to demonstrate robust methods for controlling multi-DFS-qubit systems by NMR; (5) Implementation of several quantum chaotic maps, and the discovery that these provide a scalable approach to determining the magnitude and kind of errors present in complex quantum computations; (6) The invention of a "spin amplifier", by which entanglement can be used to enable single spin measurement, and a small-scale demonstration by NMR; (7) Experiments demonstrating that the foregoing advances enable implementation of complex entangling unitary and decoherent operations, culminating in creation of a 12-qubit CAT state.

•Jul 31, 2005•0 citations
In this Letter, we present an experimental benchmark of operational control methods in quantum information processors extended up to 12 qubits. We implement universal control of this large Hilbert space using two complementary approaches and discuss their accuracy and scalability. Despite decoherence, we were able to reach a 12-coherence state (or a 12-qubit pseudopure cat state) and decode it into an 11 qubit plus one qutrit pseudopure state using liquid state nuclear magnetic resonance quantum information processors.
In building a quantum-information processor (QIP), the challenge is to coherently control a large quantum system well enough to perform an arbitrary quantum algorithm and to be able to correct errors induced by decoherence. Nuclear magnetic resonance (NMR) QIPs offer an excellent testbed on which to develop and benchmark tools and techniques to control quantum systems. Two main issues to consider when designing control methods are accuracy and efficiency, for which two complementary approaches have been developed so far to control qubit registers with liquid-state NMR methods. The first applies optimal control theory to numerically optimize the control fields to implement unitary operations on low-dimensional systems with high fidelity. The second technique is based on the efficient optimization of a sequence of imperfect control elements so that implementation of a full quantum algorithm is possible while minimizing error accumulation. This paper summarizes our work in implementing both of these methods. Furthermore, we show that taken together, they form a basis to design quantum control methods for a block-architecture QIP so that large system size is not a barrier to implementing optimal control techniques.
We propose and experimentally realize an algorithmic benchmark that demonstrates coherent control with a sequence of quantum operations that first generates and then decodes the cat state (|000...>+|111...>)/sqrt(2) to the standard initial state |000...>. This is the first high fidelity experimental quantum algorithm on the currently largest physical quantum register, which has seven quantum bits (qubits) provided by the nuclei of crotonic acid. The experiment has the additional benefit of verifying a seven coherence in a generic system of coupled spins. Our implementation combines numerous nuclear magnetic resonance (NMR) techniques in one experiment and introduces practical methods for translating quantum networks to control operations. The experimental procedure can be used as a reliable and efficient method for creating a standard pseudo-pure state, the first step for implementing traditional quantum algorithms in liquid state NMR. The benchmark and the techniques can be adapted for use on other proposed quantum devices.
Being able to quantify the level of coherent control in a proposed device implementing a quantum information processor (QIP) is an important task for both comparing different devices and assessing a device's prospects with regards to achieving fault-tolerant quantum control. We implement in a liquid-state nuclear magnetic resonance QIP the randomized benchmarking protocol presented by Knill et al (2008 Phys. Rev. A 77 012307). We report an error per randomized π/2 pulse of 1.3±0.1 × 10 −4 with a single-qubit QIP and show an experimentally relevant error model where the randomized benchmarking gives a signature fidelity decay which is not possible to interpret as a single error per gate. We explore and experimentally investigate multi-qubit extensions of this protocol and report an average error rate for one- and two-qubit gates of 4.7±0.3 × 10 −3 for a three-qubit QIP. We estimate that these error rates are still not decoherence limited and thus can be improved with modifications to the control hardware and software.
We report the implementation of an entanglement transfer on a four-qubit liquid-state nuclear-magnetic resonance quantum information processor. This consists of creating an (pseudopure) entangled state among two directly coupled spins, and then transferring this two-spin state to another pair of spins whose direct interactions are negligible. Such transfers are expected to be an essential operation in scalable quantum computer architectures, and provide a useful benchmark for the coherent control available in specific implementations.
We demonstrate the implementation of an entanglement swapping operation on a four-qubit liquid-state nuclear-magnetic-resonance (NMR) quantum-information processor. We use this experiment as a benchmark to illustrate the progress made in the field of quantum control using strongly modulating pulses and a correction scheme for removing distortions introduced by the nonlinearities in the transmitter and probe circuits. The advances include compensating for incoherent errors caused by the spatial variation of the system Hamiltonian in the NMR sample. The goal of these control sequences is to cause the collapse of the Kraus operator-sum representation of the superoperator into one unitary operator so that the ensemble appears to evolve as one coherent whole.
The most significant achievements of this project were: (1) Development and validation of the hardware and software needed to implement "strongly modulating pulses", by which high precision quantum gates can be obtain in realistic systems of up to 12 qubits; (2) A detailed analysis and evaluation of a 3-qubit quantum Fourier transform via full quantum process tomography; (3) An extensive set of mathematical and computational techniques to accomplish these goals, including Hadamard products, the real density matrix, and methods of fitting superoperators to experimental data; (4) Creation of a 3-qubit "noiseless subsystem", of a Bell state on two 2-qubit decoherence-free subspaces (DFS), and the invention of "partial" pseudopure states which will enable us to demonstrate robust methods for controlling multi-DFS-qubit systems by NMR; (5) Implementation of several quantum chaotic maps, and the discovery that these provide a scalable approach to determining the magnitude and kind of errors present in complex quantum computations; (6) The invention of a "spin amplifier", by which entanglement can be used to enable single spin measurement, and a small-scale demonstration by NMR; (7) Experiments demonstrating that the foregoing advances enable implementation of complex entangling unitary and decoherent operations, culminating in creation of a 12-qubit CAT state.