Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0508148

Precision frequency measurements with entangled states

Christian F. Roos

Published Aug 19, 2005• 10 citations
arXivHTMLPDF

Abstract

We demonstrate how quantum entanglement can be used for precision frequency measurements with trapped ions. In particular, we show how to suppress linear Zeeman shifts in optical frequency measurements by using maximally entangled states of two ions even if the individual ions do not have any field-independent transition. In addition, this technique allows for an accurate measurement of small external field frequency shifts such as the electric quadrupole shift which are important for ion clock experiments.

DOI
10.48550/arxiv.quant-ph/0508148

Related papers

Precision frequency measurements with entangled ions

Christian F. Roos, Michael Chwalla, Mark Riebe +6 more

Summary form only given. The use of entangled states can provide an increased sensitivity in quantum-limited spectroscopic measurements, leading to an uncertainty that is inversely proportional to the number of particles instead of the usual square-law dependence. In this contribution, we show that spectroscopy with maximally entangled states of atoms also offers significant advantages over experiments done with single atoms. As a first example, we demonstrate that entanglement can be used to effectively eliminate first-order Zeeman shifts in spectroscopy with 40Ca+ even though there are no m=0 -> m=0 transitions. Secondly, we discuss how maximally correlated states of two 40Ca+ could be used for measuring tiny frequency shifts of the S1/2 - D5/2 transition arising from second-order Zeeman shifts and electric quadrupole shifts due to the trapping potential.

European Frequency and Time Forum•Jan 1, 2004•0 citations

The mercury-ion optical clock: towards a measurement of the quadrupole shift

Windell H. Oskay, A. Bartels, Scott A. Diddams +6 more

An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1

European Frequency and Time Forum•Jan 1, 2004•2 citations

Electric Quadrupole Shift Cancellation in Single-Ion Optical Frequency Standards

P. Dubé, Alan A. Madej, J. E. Bernard +3 more

The electric quadrupole shift is presently the most significant source of uncertainty on the systematic shifts for several single-ion optical frequency standards. We present a simple method for cancelling this shift based on measurements of the Zeeman spectrum of the clock transition. This method is easy to implement and yields very high cancellation levels. A fractional uncertainty of 5 x 10(-18) for the canceled quadrupole shift is estimated for a measurement of the absolute frequency of the 5s (2)S(1/2)-4d (2)D(5/2) clock transition of 88Sr+.

Physical Review Letters•Jul 12, 2005•152 citations

Atomic combination clocks

Nitzan Akerman, Roee Ozeri

Atomic clocks use atomic transitions as frequency references. The susceptibility of the atomic transition to external fields limits clock stability and introduces systematic frequency shifts. Here, we propose to realize an atomic clock that utilizes an entangled superposition of states of multiple atomic species, where the reference frequency is a sum of the individual transition frequencies. The superposition is selected such that the susceptibilities of the respective transitions, in individual species, partially cancel leading to improved stability and a reduction in the corresponding systematic shifts. We present and analyze two examples of such combinations. The first uses the optical quadrupole transitions in a Ca + – Yb + two-ion system. The second is a superposition of optical quadrupole transitions in one Sr + ion and three Hg + ions. These combinations have reduced susceptibility to external magnetic fields and blackbody radiation.

arXiv:1709.01247•New Journal of Physics•Nov 29, 2018•7 citations

Single Ca + Ion Trapping toward Precise Frequency Measurement of the 4 2 S 1/2 - 3 2 D 5/2 Transition

Kouki Matsubara, Y. Li, Masatoshi Kajita +3 more

Abstract —We are proceeding with a development of an optical frequency standard using a 2 S 1/2 – 2 D 5/2 electric quadrupole transition of Ca + ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of <1 x 10 -15 is attainable in measurement of the 2 S 1/2 – 2 D 5/2 transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single 40 Ca + ions to the 2 D 5/2 state. I. I NTRODUCTION The uncertainty of primary frequency standards using Cs atoms reaches around 10 -15 and the inherent limits involved in them are discussed. On the other hand, frequency standards using new materials and methods are proposed for developing more accurate frequency standards. Recently, several groups have measured frequencies of the ionic forbidden transitions in the optical region to apply them to the clock transitions of optical frequency standards [1]. We now proceeds with study on an optical frequency standard using single Ca

•Aug 31, 2005•2 citations

Frequency measurement of the40Ca+clock transition using a LD-based clock laser and UTC(NICT)

K. Matsubara, Y. Li, Shigeo Nagano +6 more

We developed an optical frequency standard with the 4 2S1/2-3 2D5/2 electric quadrupole transition of 40Ca+ ions. Its absolute transition frequency is 411 042 129 776 390(±7) Hz. The accuracy is limited by the electric quadrupole shift and the ambient magnetic field fluctuation. To determine the absolute transition frequency with a better accuracy, we have observed two pairs of the symmetrically-splitting Zeeman components and measured the transition frequency corrected for the electric quadrupole shift. In addition, we are developing a magnetic-shielded ion-trap chamber to suppress the transition-line broadening caused by the magnetic field fluctuation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 20, 2009•0 citations
We demonstrate how quantum entanglement can be used for precision frequency measurements with trapped ions. In particular, we show how to suppress linear Zeeman shifts in optical frequency measurements by using maximally entangled states of two ions even if the individual ions do not have any field-independent transition. In addition, this technique allows for an accurate measurement of small external field frequency shifts such as the electric quadrupole shift which are important for ion clock experiments.
Summary form only given. The use of entangled states can provide an increased sensitivity in quantum-limited spectroscopic measurements, leading to an uncertainty that is inversely proportional to the number of particles instead of the usual square-law dependence. In this contribution, we show that spectroscopy with maximally entangled states of atoms also offers significant advantages over experiments done with single atoms. As a first example, we demonstrate that entanglement can be used to effectively eliminate first-order Zeeman shifts in spectroscopy with 40Ca+ even though there are no m=0 -> m=0 transitions. Secondly, we discuss how maximally correlated states of two 40Ca+ could be used for measuring tiny frequency shifts of the S1/2 - D5/2 transition arising from second-order Zeeman shifts and electric quadrupole shifts due to the trapping potential.
An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1
The electric quadrupole shift is presently the most significant source of uncertainty on the systematic shifts for several single-ion optical frequency standards. We present a simple method for cancelling this shift based on measurements of the Zeeman spectrum of the clock transition. This method is easy to implement and yields very high cancellation levels. A fractional uncertainty of 5 x 10(-18) for the canceled quadrupole shift is estimated for a measurement of the absolute frequency of the 5s (2)S(1/2)-4d (2)D(5/2) clock transition of 88Sr+.
Atomic clocks use atomic transitions as frequency references. The susceptibility of the atomic transition to external fields limits clock stability and introduces systematic frequency shifts. Here, we propose to realize an atomic clock that utilizes an entangled superposition of states of multiple atomic species, where the reference frequency is a sum of the individual transition frequencies. The superposition is selected such that the susceptibilities of the respective transitions, in individual species, partially cancel leading to improved stability and a reduction in the corresponding systematic shifts. We present and analyze two examples of such combinations. The first uses the optical quadrupole transitions in a Ca + – Yb + two-ion system. The second is a superposition of optical quadrupole transitions in one Sr + ion and three Hg + ions. These combinations have reduced susceptibility to external magnetic fields and blackbody radiation.
Abstract —We are proceeding with a development of an optical frequency standard using a 2 S 1/2 – 2 D 5/2 electric quadrupole transition of Ca + ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of <1 x 10 -15 is attainable in measurement of the 2 S 1/2 – 2 D 5/2 transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single 40 Ca + ions to the 2 D 5/2 state. I. I NTRODUCTION The uncertainty of primary frequency standards using Cs atoms reaches around 10 -15 and the inherent limits involved in them are discussed. On the other hand, frequency standards using new materials and methods are proposed for developing more accurate frequency standards. Recently, several groups have measured frequencies of the ionic forbidden transitions in the optical region to apply them to the clock transitions of optical frequency standards [1]. We now proceeds with study on an optical frequency standard using single Ca
We developed an optical frequency standard with the 4 2S1/2-3 2D5/2 electric quadrupole transition of 40Ca+ ions. Its absolute transition frequency is 411 042 129 776 390(±7) Hz. The accuracy is limited by the electric quadrupole shift and the ambient magnetic field fluctuation. To determine the absolute transition frequency with a better accuracy, we have observed two pairs of the symmetrically-splitting Zeeman components and measured the transition frequency corrected for the electric quadrupole shift. In addition, we are developing a magnetic-shielded ion-trap chamber to suppress the transition-line broadening caused by the magnetic field fluctuation.