The three-wave mixing processes in a second-order nonlinear medium can be used for imaging protocols, in which an object field is injected into the nonlinear medium together with a reference field and an image field is generated. When the reference field is chaotic, the image field is also chaotic and does not carry any information about the object. We show that a clear image of the object can be extracted from the chaotic image field by measuring the spatial intensity correlations between this field and one Fourier component of the reference. We experimentally verify this imaging protocol in the case of difference-frequency generation.
The three-wave mixing processes in a second-order nonlinear medium can be used for imaging protocols, in which an object field is injected into the nonlinear medium together with a reference field and an image field is generated. When the reference field is chaotic, the image field is also chaotic and does not carry any information about the object. We show that a clear image of the object can be extracted from the chaotic image field by measuring the spatial intensity correlations between this field and one Fourier component of the reference. We experimentally verify this imaging protocol in the case of difference-frequency generation.
We analyze and recover, by means of spatial intensity correlations, the image obtained by a seeded frequency-downconversion process in which the seed field is chaotic and an intensity modulation is encoded in the pump field. Although the field generated is as chaotic as the seed field and does not carry any information about the modulation of the pump, one can extract an image of the pump by measuring the spatial intensity correlations between the generated field and one Fourier component of the seed.
We record frequency-downconverted images that are chaotic, as they are obtained in a χ(2) crystal from the interaction of two pulsed pseudo-thermal fields of which the one at the higher frequency encountered the imaged object. Spatial correlations of the intensity fluctuations in these chaotic images with the intensity of a single spatial Fourier component of the low-frequency input field, allow image retrieval if the number of records on which the ensemble-averages are calculated is suitably large. When it is too small to achieve a satisfactory result, we show that computing the correlations in parallel with different components of the low-frequency input field, shifting the correlation maps according to a rule suggested by 3D phase-matching, and averaging them, leads to the recovery of the downconverted image. The method can be used for secure and fast image transmission.
We present experiments of χ (2) difference-frequency processes at frequency degeneracy in regime of high intensity. In the first experiment, we exploit ghost-imaging in the context of quantum cryptography in an attempt to overcome the limitation of the quantum key distribution of keys as long as the image. The code to be encrypted is the string of the power values measured by Alice in the test arm. In the second experiment, we generate frequency down-converted images that are chaotic as, at each laser shot, both the field at 2ω illuminating the object to be imaged and the seed-field at ω are made pseudo-thermal in space. The images are recovered from the recorded chaotic ones by correlating the local intensity fluctuations with those of the seed-field Fourier components. Calculating the correlations in parallel with many Fourier components allows image retrieval by averaging on ensembles of fewer recorded images.
The interaction of light waves in crystals with a quadratic nonlinearity is considered. It is shown that when one of the interacting waves carries information on the image of an object, such information can be transferred to a different wavelength, providing the basis for a parametric image converter. The results are given of experimental measurements of the noise and sensitivity of parametric-conversion detectors. It is shown that when both interacting waves carry information on an object, the interaction in a nonlinear crystal allows us to obtain correlation functions of the initial images of the objects. Suitable systems make it possible to determine experimentally the correlation function of the images of simple objects. By way of example, a description is given of a system which makes it possible to remove phase distortions introduced by an optical system in the far-field zone.
The dynamics of optical nonlinearity in the presence of gain and feedback can be complex leading to chaos in certain regimes. Temporal, spectral, spatial, or polarization instability of optical fields can emerge from chaotic response of an optical [Formula: see text] or [Formula: see text] nonlinear medium placed between two cavity mirrors or before a single feedback mirror. The complex mode dynamics, high-order correlations, and transition to instability in these systems are not well known. We consider a [Formula: see text] medium with amplified four-wave mixing process and study noise and correlation between multiple optical modes. Although individual modes show intensity instability, we observe relative intensity noise reduction close to the standard quantum noise, limited by the camera speed. We observe a relative noise reduction of more than 20 dB and fourth-order intensity correlation between four spatial modes. More than 100 distinct correlated quadruple modes can be generated using this process.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.