arXiv:quant-ph/0406113 · Optics Letters

Generation of twin beams from an optical parametric oscillator pumped by a frequency-doubled diode laser

Kazuhiro Hayasaka, Yun Zhang, Katsuyuki Kasai

Published Jul 15, 2004• 32 citations
arXivHTMLPDF

Abstract

Quantum-correlated twin beams were generated from a triply resonant optical parametric oscillator with an a-cut KTP crystal pumped by a frequency-doubled diode laser. A total output of 5.1 mW was obtained in the classical-nonclassical light-conversion system driven by a 50-mW diode laser at 1080 nm. A quantum-noise reduction of 4.3 dB (63%) in the intensity difference between the twin beams was successfully observed at the detection frequency of 3 MHz.

DOI
10.1364/ol.29.001665

Related papers

Nonclassical light generation from an optical parametric oscillator pumped by a frequency-doubled diode laser

Kazuhiro Hayasaka, Yun Zhang, Katsuyuki Kasai

Quantum-correlated twin beams were successfully generated from an optical parametric oscillator (OPO) pumped by a frequency-doubled diode laser. The 50-mW diode laser output at 1080 nm was first converted to 22.5-mW green light, and then was used to pump an OPO to yield signal and idler beams with a total power of 5 mW. Noise reduction of 4.3 dB below the shot-noise level was observed in the intensity-difference spectrum. The setup opens a simple way to a compact and low-cost source of diverse nonclassical states of light.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 11, 2005•0 citations

Generation and application of twin beams from an optical parametric oscillator including an ?-cut KTP crystal

Jiangrui Gao, Fuyun Cui, Chenyang Xue +2 more

Measurement slight amounts of absorption of light with accuracy beyond the standard quantum limit has been experimentally demonstrated. The quantum-correlated twin beams used in the measurement were generated from a nondegenerate optical parametric oscillator including an alpha-cut KTiOPO(4) crystal pumped by an intracavity frequency-doubled Nd:YAG laser. The noise in the intensity difference between the twin beams was reduced by 88% below the standard quantum limit (SQL). The signal-to-noise ratio was improved by 7 dB with respect to the SQL of the total light employed in the experiment and by 4 dB with respect to that of the signal light.

Optics Letters•Jun 1, 1998•83 citations

Application of an all-solid-state, frequency-doubled Nd:YAP laser to the generation of twin beams at 1080 nm

Ruixiang Guo, Julien Laurat, Jiangrui Gao +2 more

A laser-diode-pumped intracavity frequency-doubled Nd:YAP/KTP laser is presented. Over 110 mw of TEM00 single-frequency output power at 540-nm wavelength was obtained. The output green laser was employed to pump a semimonolithic nondegenerate optical parametric oscillator to produce intensity quantum correlated twin beams at 1080 nm, and the maximum quantum noise squeezing of 74% (5.9dB) on the intensity difference fluctuation between the twin beams is observed. The threshold was reduced and the stability was increased significantly when compared with similar lamp-pumped systems.

arXiv:quant-ph/0512033•Applied Optics•Apr 20, 2002•7 citations

Quantum correlated twin beams in cascaded optical parametric oscillator

Salvatore Castrignano, Iolanda Ricciardi, P. Maddaloni +3 more

We experimentally generate twin beams through cascaded quadratic processes in a nonlinear χ(2) crystal, leading to an internally pumped optical parametric oscillation, in a doubly resonant second-harmonic generation system. The exploration of the non-classical properties of these beams enabled the observation of up to 5 dB of noise reduction in their intensity difference below the standard quantum limit.

SPIE Conference on Nonlinear Optics and its Applications•Jun 20, 2024•0 citations

Twin-beam generation in a triply resonant dual-cavity optical parametric oscillator

Joseph Teja, N. C. Wong

We demonstrate a low-threshold twin-beam generator using a cw triply resonant optical parametric oscillator consisting of two coupled cavities: one that resonates the signal and idler waves and the other the pump field. An intensity correlation of 5.5 dB was observed at 3 MHz for a type-II phase-matched KTP optical parametric oscillator.

Optics Express•Feb 2, 1998•23 citations

Experimental investigation of intensity difference squeezing using Nd:YAP laser as pump source

Qing Pan, Yun Zhang, Tiancai Zhang +2 more

A strong quantum correlation between twin-beams at wavelength was observed. The intensity difference noise of twin-beams, which is generated by a semimonolithic OPO cavity pumped by a frequency-doubled and stabilized Nd:YAP laser, is about 80% (7 dB) below the short noise limit at the measurement frequency of 1.5 MHz. The threshold of the optical parametric oscillator is about 20 mW. The parametric dependence of the quantum correlation is experimentally investigated. The experimental results agree with the theory well.

Journal of Physics D Applied Physics•Jun 7, 1997•12 citations
Quantum-correlated twin beams were generated from a triply resonant optical parametric oscillator with an a-cut KTP crystal pumped by a frequency-doubled diode laser. A total output of 5.1 mW was obtained in the classical-nonclassical light-conversion system driven by a 50-mW diode laser at 1080 nm. A quantum-noise reduction of 4.3 dB (63%) in the intensity difference between the twin beams was successfully observed at the detection frequency of 3 MHz.
Quantum-correlated twin beams were successfully generated from an optical parametric oscillator (OPO) pumped by a frequency-doubled diode laser. The 50-mW diode laser output at 1080 nm was first converted to 22.5-mW green light, and then was used to pump an OPO to yield signal and idler beams with a total power of 5 mW. Noise reduction of 4.3 dB below the shot-noise level was observed in the intensity-difference spectrum. The setup opens a simple way to a compact and low-cost source of diverse nonclassical states of light.
Measurement slight amounts of absorption of light with accuracy beyond the standard quantum limit has been experimentally demonstrated. The quantum-correlated twin beams used in the measurement were generated from a nondegenerate optical parametric oscillator including an alpha-cut KTiOPO(4) crystal pumped by an intracavity frequency-doubled Nd:YAG laser. The noise in the intensity difference between the twin beams was reduced by 88% below the standard quantum limit (SQL). The signal-to-noise ratio was improved by 7 dB with respect to the SQL of the total light employed in the experiment and by 4 dB with respect to that of the signal light.
A laser-diode-pumped intracavity frequency-doubled Nd:YAP/KTP laser is presented. Over 110 mw of TEM00 single-frequency output power at 540-nm wavelength was obtained. The output green laser was employed to pump a semimonolithic nondegenerate optical parametric oscillator to produce intensity quantum correlated twin beams at 1080 nm, and the maximum quantum noise squeezing of 74% (5.9dB) on the intensity difference fluctuation between the twin beams is observed. The threshold was reduced and the stability was increased significantly when compared with similar lamp-pumped systems.
A strong quantum correlation between twin-beams at wavelength was observed. The intensity difference noise of twin-beams, which is generated by a semimonolithic OPO cavity pumped by a frequency-doubled and stabilized Nd:YAP laser, is about 80% (7 dB) below the short noise limit at the measurement frequency of 1.5 MHz. The threshold of the optical parametric oscillator is about 20 mW. The parametric dependence of the quantum correlation is experimentally investigated. The experimental results agree with the theory well.