Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0405056

Ghost imaging, quantum and classical aspects

A. Gatti, E. Brambilla, Morten Bache, L. A. Lugiato

Published May 11, 2004• 5 citations
arXivHTMLPDF

Abstract

We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near-field and in the far-field. Using realistic numerical simulations the performances of a quasi-thermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a new scenario for the discussion of what role the entanglement plays in correlated imaging.

DOI
10.48550/arxiv.quant-ph/0405056

Related papers

Correlated imaging, quantum and classical

A. Gatti, E. Brambilla, Morten Bache +1 more

We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near field and in the far field. Using realistic numerical simulations the performances of a quasithermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a scenario for the discussion of what role the entanglement plays in correlated imaging.

Physical Review A•Jul 6, 2004•414 citations

Ghost Imaging with Thermal Light: Comparing Entanglement and ClassicalCorrelation

A. Gatti, E. Brambilla, Morten Bache +1 more

We consider a scheme for coherent imaging that exploits the classical correlation of two beams obtained by splitting incoherent thermal radiation. This case is analyzed in parallel with the configuration based on two entangled beams produced by parametric down-conversion, and a precise formal analogy is pointed out. This analogy opens the possibility of using classical beams from thermal radiation for ghost imaging schemes in the same way as entangled beams.

arXiv:quant-ph/0307187•Physical Review Letters•Aug 26, 2004•944 citations

Correlated imaging: classical noise vs. quantum entanglement

Luigi A. Lugiato, A. Gatti, E. Brambilla +1 more

We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. The case of such two classically correlated beams is treated in parallel with the configuration based on two entangled beams produced by parametric down-conversion, and a basic analogy is pointed out. The results are compared in a specific numerical example.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 25, 2004•3 citations

Correlated imaging with macroscopic fields

E. Brambilla, A. Gatti, Morten Bache +1 more

Abstract We demonstrate analytically that correlated imaging in the regime of large photon number can be implemented using both a classical and an entangled source. The classically correlated beams are obtained by dividing thermal radiation by a beam splitter while entangled beams are obtained through parametric down‐conversion. By treating the two system in parallel, a formal analogy is outlined between the two cases showing that classical beams can mimic qualitatively all the imaging features of the entangled beams. We also propose a method to improve substantially the imaging performances of correlated imaging which is based on homodyne detection combined with spatial averages.

Fortschritte der Physik•Oct 11, 2004•5 citations

Quantum and Classical Coincidence Imaging

Ryan S. Bennink, Sean J. Bentley, Robert W. Boyd +1 more

Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.

Physical Review Letters•Jan 22, 2004•417 citations

Theoretic approach to ghost imaging in the frequency domain performed by means of a high brilliance coherent monochromatic source

Marco Chiarini, Alberto Parini, Francesca Braglia +6 more

Ghost imaging is a novel non-conventional technique allowing to generate high resolution images by correlating the intensity of two light beams, neither of which independently contains sufficient information about the spatial distribution and shape of the object. The first demonstration of ghost imaging used light in double photon state, obtained from spontaneous parametric down-conversion. Owing to the entanglement of the source photons, the proposed theory required quantum descriptions for both the optical source and its photo-detection statistics1. However, subsequent experimental and theoretical considerations2,3 demonstrated that ghost imaging can be performed also with thermalized light, utilizing either CCD detector arrays or photon-counting detectors, thus admitting to a semi-classical description, employing classical fields and shot-noise limited detectors. This has generated increasing interest4-6 in establishing a unifying theory that characterizes the fundamental physics of ghost imaging and defines the boundary between classical and quantum domains. In this view, we exploited recent progress obtained through the application of Fourier Transform Techniques to demonstrate ghost imaging in the frequency domain, in order to measure a continuous spectrum by using a highly brilliant and coherent monochromatic source. In particular, we demonstrate the application of this ghost imaging technique to broadband spectroscopic measurements by means of interaction free photon detection. The experimental apparatus and the collected data are described in a dedicated work7. In this paper, we consider the theoretical aspects underlying the proposed Spectroscopic technique. In particular, two alternative theoretical models are presented. In one case, a statistical approach (semi-classical) is applied, where the states of the sampling beam are considered, whereas in the other case a pure quantum treatment is carried on, by describing the interaction of vacuum states generated by photon conversion processes. Both theoretical models, though carried on by means of a complementary formalism, lead to equivalent results and offer a physical interpretation of the collected experimental data. The application of these results offer novel perspectives for remote sensing in low light conditions, or in spectral regions where sensitive detectors are lacking.

Electro-Optical and Infrared Systems: Technology and Applications•Oct 9, 2019•1 citation
We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near-field and in the far-field. Using realistic numerical simulations the performances of a quasi-thermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a new scenario for the discussion of what role the entanglement plays in correlated imaging.
We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near field and in the far field. Using realistic numerical simulations the performances of a quasithermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a scenario for the discussion of what role the entanglement plays in correlated imaging.
Abstract We demonstrate analytically that correlated imaging in the regime of large photon number can be implemented using both a classical and an entangled source. The classically correlated beams are obtained by dividing thermal radiation by a beam splitter while entangled beams are obtained through parametric down‐conversion. By treating the two system in parallel, a formal analogy is outlined between the two cases showing that classical beams can mimic qualitatively all the imaging features of the entangled beams. We also propose a method to improve substantially the imaging performances of correlated imaging which is based on homodyne detection combined with spatial averages.
Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.
Ghost imaging is a novel non-conventional technique allowing to generate high resolution images by correlating the intensity of two light beams, neither of which independently contains sufficient information about the spatial distribution and shape of the object. The first demonstration of ghost imaging used light in double photon state, obtained from spontaneous parametric down-conversion. Owing to the entanglement of the source photons, the proposed theory required quantum descriptions for both the optical source and its photo-detection statistics1. However, subsequent experimental and theoretical considerations2,3 demonstrated that ghost imaging can be performed also with thermalized light, utilizing either CCD detector arrays or photon-counting detectors, thus admitting to a semi-classical description, employing classical fields and shot-noise limited detectors. This has generated increasing interest4-6 in establishing a unifying theory that characterizes the fundamental physics of ghost imaging and defines the boundary between classical and quantum domains. In this view, we exploited recent progress obtained through the application of Fourier Transform Techniques to demonstrate ghost imaging in the frequency domain, in order to measure a continuous spectrum by using a highly brilliant and coherent monochromatic source. In particular, we demonstrate the application of this ghost imaging technique to broadband spectroscopic measurements by means of interaction free photon detection. The experimental apparatus and the collected data are described in a dedicated work7. In this paper, we consider the theoretical aspects underlying the proposed Spectroscopic technique. In particular, two alternative theoretical models are presented. In one case, a statistical approach (semi-classical) is applied, where the states of the sampling beam are considered, whereas in the other case a pure quantum treatment is carried on, by describing the interaction of vacuum states generated by photon conversion processes. Both theoretical models, though carried on by means of a complementary formalism, lead to equivalent results and offer a physical interpretation of the collected experimental data. The application of these results offer novel perspectives for remote sensing in low light conditions, or in spectral regions where sensitive detectors are lacking.