arXiv:quant-ph/0401107 · Physical Review Letters

Suppression of Spin Projection Noise in Broadband Atomic Magnetometry

J. M. Geremia, John K. Stockton, Hideo Mabuchi

Published May 24, 2005• 65 citations
arXivHTMLPDF

Abstract

We demonstrate that quantum nondemolition measurement, combined with a suitable parameter estimation procedure, can improve the sensitivity of a broadband atomic magnetometer by reducing uncertainty due to spin projection noise. Furthermore, we provide evidence that real-time quantum feedback control offers robustness to classical uncertainties, including shot-to-shot atom number fluctuations, that would otherwise prevent quantum-limited performance.

DOI
10.1103/physrevlett.94.203002

Related papers

Sub-Projection-Noise Sensitivity in Broadband Atomic Magnetometry

Marco Koschorreck, M. Napolitano, B. Dubost +1 more

We demonstrate sub-projection-noise sensitivity of a broadband atomic magnetometer using quantum nondemolition spin measurements. A cold, dipole-trapped sample of rubidium atoms provides a long-lived spin system in a nonmagnetic environment, and is probed nondestructively by paramagnetic Faraday rotation. The calibration procedure employs as known reference state, the maximum-entropy or "thermal" spin state, and quantitative imaging-based atom counting to identify electronic, quantum, and technical noise in both the probe and spin system. The measurement achieves a sensitivity 1.6 dB (2.8 dB) better than projection-noise (thermal state quantum noise) and will enable squeezing-enhanced broadband magnetometry.

arXiv:0911.4491•Physical Review Letters•Mar 3, 2010•168 citations

Can a Quantum Nondemolition Measurement Improve the Sensitivity of an Atomic Magnetometer?

Marcis P. Auzinsh, Dmitry Budker, Derek F. Jackson Kimball +4 more

We consider the limitations due to noise (e.g., quantum projection noise and photon shot-noise) on the sensitivity of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of $N$ atomic spins by detecting optical rotation of far-detuned light. We show that for very short measurement times, the optimal sensitivity scales as ${N}^{\ensuremath{-}3/4}$; if strongly squeezed probe light is used, the Heisenberg limit of ${N}^{\ensuremath{-}1}$ scaling can be achieved. However, if the measurement time exceeds ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/{N}^{1/2}$ in the former case, or ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/N$ in the latter, where ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}$ is the spin relaxation time, the scaling becomes ${N}^{\ensuremath{-}1/2}$, as for a standard shot-noise-limited magnetometer.

arXiv:physics/0403097•Physical Review Letters•Oct 19, 2004•153 citations

Real-time optimal quantum control for atomic magnetometers with decoherence

Julia Amoros-Binefa

Quantum entanglement, in the form of spin squeezing, is known to improve the sensitivity of atomic sensors to static or slowly varying fields. Sensing transient events presents a distinct challenge, requires different analysis tools, and has not been shown to benefit from entanglement in practically important scenarios such as spin-precession magnetometry. To address this, we apply concepts from continuous quantum measurements and estimation theory to optical atomic magnetometers, aiming to accurately model these devices, interpret their measurement data, control their dynamics, and achieve optimal sensitivity. Quantifying this optimal performance requires determining a fundamental quantum limit on sensitivity. We derive this limit, imposed by noise, and show that it scales at best linearly with sensing time and atom number N, ruling out any super-classical scaling. This limit is independent of the initial state, measurement, estimator, and measurement-based feedback, and depends only on the decoherence model and the strength of field fluctuations. Thus, finding an estimator that attains this bound proves the sensing strategy optimal. To approach this limit, we develop a quantum dynamical model scalable with N, based on a co-moving Gaussian approximation of the stochastic master equation, which includes measurement backaction and decoherence. This enables a real-time estimation and control architecture integrating an extended Kalman filter with a linear quadratic regulator. Simulating the magnetometer with our model and EKF+LQR strategy shows that quantum-limited tracking of constant and fluctuating fields is within reach of current atomic magnetometers. Our sensing strategy can also track biologically relevant signals, such as heartbeat-like waveforms, and drive the atomic ensemble into an entangled state, even when the measurement record is used for feedback but later discarded.

quant-pharXiv:2512.05265•Dec 8, 2025•0 citations

Noisy Atomic Magnetometry with Kalman Filtering and Measurement-Based Feedback

Júlia Amorós-Binefa, Jan Kołodyński

Sensing a magnetic field with an atomic magnetometer operated in real time presents significant challenges, primarily due to sensor nonlinearity, the presence of noise, and the need for one-shot estimation. To address these challenges, we propose a comprehensive approach that integrates measurement, estimation, and control strategies. Specifically, this involves implementing a quantum nondemolition measurement based on continuous light probing of the atomic ensemble. The resulting photocurrent is then directed into an extended Kalman filter to produce instantaneous estimates of the system’s dynamical parameters. These estimates, in turn, are utilized by a linear quadratic regulator, whose output is applied back to the system through a feedback loop. This procedure automatically steers the atomic ensemble into a spin-squeezed state, yielding a quantum enhancement in precision. Furthermore, thanks to the feedback proposed, the atoms exhibit entanglement even when the measurement data are discarded. To prove that our approach constitutes the optimal strategy in realistic scenarios, we derive ultimate bounds on the estimation error applicable in the presence of both local and collective decoherence, and show that these are indeed attained. Additionally, we demonstrate that, for large ensembles, the extended Kalman filter not only reliably predicts its own estimation error in real time, but also accurately estimates spin squeezing at short timescales.

arXiv:2403.14764•PRX Quantum•Jul 2, 2025•16 citations

Closed-loop Quantum Parameter Estimation: Spins in a Magnetic Field

J. M. Geremia, John K. Stockton, Hideo Mabuchi

We present an experimental demonstration of closed-loop quantum parameter estimation in which real-time feedback is used to achieve robustness to modeling uncertainty. By performing broadband estimation of a magnetic field acting on hyperfine spins in a cold atom ensemble, we show that accuracy is not compromised by fluctuations in total atom number even though the measured signal in our canonical configuration depends only on the product of the field and atom number. This methodology could be essential for efforts to utilize conditional squeezing in spin-resonance measurements.

arXiv:quant-ph/0309034•Sep 3, 2003•4 citations

Spin damping in an rf atomic magnetometer

Orang Alem, Karen L. Sauer, M. V. Romalis

Under negative feedback, the quality factor $Q$ of a radio-frequency atomic magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the magnetometer for detection of the desired signal. We find that noise is also suppressed under such spin damping, with a characteristic spectral response corresponding to the type of noise; therefore magnetic, photon shot, and spin-projection noise can be measured distinctly. While the suppression of resonant photon shot noise implies the closed-loop production of polarization-squeezed light, the suppression of resonant spin-projection noise does not imply spin squeezing, rather simply the broadening of the noise spectrum with $Q$. Furthermore, the application of spin damping during phase-sensitive detection suppresses both signal and noise in such a way as to increase the sensitivity bandwidth. We demonstrate a threefold increase in the magnetometer's bandwidth while maintaining 0.3 fT/$\sqrt{\mathrm{Hz}}$ sensitivity.

arXiv:1207.2842•Physical Review A•Jan 16, 2013•22 citations
We demonstrate that quantum nondemolition measurement, combined with a suitable parameter estimation procedure, can improve the sensitivity of a broadband atomic magnetometer by reducing uncertainty due to spin projection noise. Furthermore, we provide evidence that real-time quantum feedback control offers robustness to classical uncertainties, including shot-to-shot atom number fluctuations, that would otherwise prevent quantum-limited performance.
We demonstrate sub-projection-noise sensitivity of a broadband atomic magnetometer using quantum nondemolition spin measurements. A cold, dipole-trapped sample of rubidium atoms provides a long-lived spin system in a nonmagnetic environment, and is probed nondestructively by paramagnetic Faraday rotation. The calibration procedure employs as known reference state, the maximum-entropy or "thermal" spin state, and quantitative imaging-based atom counting to identify electronic, quantum, and technical noise in both the probe and spin system. The measurement achieves a sensitivity 1.6 dB (2.8 dB) better than projection-noise (thermal state quantum noise) and will enable squeezing-enhanced broadband magnetometry.
We consider the limitations due to noise (e.g., quantum projection noise and photon shot-noise) on the sensitivity of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of NNN atomic spins by detecting optical rotation of far-detuned light. We show that for very short measurement times, the optimal sensitivity scales as ${N}^{\ensuremath{-}3/4}$; if strongly squeezed probe light is used, the Heisenberg limit of ${N}^{\ensuremath{-}1}$ scaling can be achieved. However, if the measurement time exceeds ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/{N}^{1/2}$ in the former case, or ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/N$ in the latter, where ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}$ is the spin relaxation time, the scaling becomes ${N}^{\ensuremath{-}1/2}$, as for a standard shot-noise-limited magnetometer.
Quantum entanglement, in the form of spin squeezing, is known to improve the sensitivity of atomic sensors to static or slowly varying fields. Sensing transient events presents a distinct challenge, requires different analysis tools, and has not been shown to benefit from entanglement in practically important scenarios such as spin-precession magnetometry. To address this, we apply concepts from continuous quantum measurements and estimation theory to optical atomic magnetometers, aiming to accurately model these devices, interpret their measurement data, control their dynamics, and achieve optimal sensitivity. Quantifying this optimal performance requires determining a fundamental quantum limit on sensitivity. We derive this limit, imposed by noise, and show that it scales at best linearly with sensing time and atom number N, ruling out any super-classical scaling. This limit is independent of the initial state, measurement, estimator, and measurement-based feedback, and depends only on the decoherence model and the strength of field fluctuations. Thus, finding an estimator that attains this bound proves the sensing strategy optimal. To approach this limit, we develop a quantum dynamical model scalable with N, based on a co-moving Gaussian approximation of the stochastic master equation, which includes measurement backaction and decoherence. This enables a real-time estimation and control architecture integrating an extended Kalman filter with a linear quadratic regulator. Simulating the magnetometer with our model and EKF+LQR strategy shows that quantum-limited tracking of constant and fluctuating fields is within reach of current atomic magnetometers. Our sensing strategy can also track biologically relevant signals, such as heartbeat-like waveforms, and drive the atomic ensemble into an entangled state, even when the measurement record is used for feedback but later discarded.
Sensing a magnetic field with an atomic magnetometer operated in real time presents significant challenges, primarily due to sensor nonlinearity, the presence of noise, and the need for one-shot estimation. To address these challenges, we propose a comprehensive approach that integrates measurement, estimation, and control strategies. Specifically, this involves implementing a quantum nondemolition measurement based on continuous light probing of the atomic ensemble. The resulting photocurrent is then directed into an extended Kalman filter to produce instantaneous estimates of the system’s dynamical parameters. These estimates, in turn, are utilized by a linear quadratic regulator, whose output is applied back to the system through a feedback loop. This procedure automatically steers the atomic ensemble into a spin-squeezed state, yielding a quantum enhancement in precision. Furthermore, thanks to the feedback proposed, the atoms exhibit entanglement even when the measurement data are discarded. To prove that our approach constitutes the optimal strategy in realistic scenarios, we derive ultimate bounds on the estimation error applicable in the presence of both local and collective decoherence, and show that these are indeed attained. Additionally, we demonstrate that, for large ensembles, the extended Kalman filter not only reliably predicts its own estimation error in real time, but also accurately estimates spin squeezing at short timescales.
We present an experimental demonstration of closed-loop quantum parameter estimation in which real-time feedback is used to achieve robustness to modeling uncertainty. By performing broadband estimation of a magnetic field acting on hyperfine spins in a cold atom ensemble, we show that accuracy is not compromised by fluctuations in total atom number even though the measured signal in our canonical configuration depends only on the product of the field and atom number. This methodology could be essential for efforts to utilize conditional squeezing in spin-resonance measurements.
Under negative feedback, the quality factor QQQ of a radio-frequency atomic magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the magnetometer for detection of the desired signal. We find that noise is also suppressed under such spin damping, with a characteristic spectral response corresponding to the type of noise; therefore magnetic, photon shot, and spin-projection noise can be measured distinctly. While the suppression of resonant photon shot noise implies the closed-loop production of polarization-squeezed light, the suppression of resonant spin-projection noise does not imply spin squeezing, rather simply the broadening of the noise spectrum with QQQ. Furthermore, the application of spin damping during phase-sensitive detection suppresses both signal and noise in such a way as to increase the sensitivity bandwidth. We demonstrate a threefold increase in the magnetometer's bandwidth while maintaining 0.3 fT/Hz\sqrt{\mathrm{Hz}}Hz​ sensitivity.