Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0304160 · Physical Review Letters

Demonstration of Dispersion-Canceled Quantum-Optical Coherence Tomography

Magued B. Nasr, Bahaa E. A. Saleh, Alexander V. Sergienko, Malvin Carl Teich

Published Aug 22, 2003• 335 citations
arXivHTMLPDF

Abstract

We present an experimental demonstration of quantum-optical coherence tomography. The technique makes use of an entangled twin-photon light source to carry out axial optical sectioning. It is compared to conventional optical coherence tomography. The immunity of the quantum version to dispersion, as well as a factor of 2 enhancement in resolution, is experimentally demonstrated.

DOI
10.1103/physrevlett.91.083601

Related papers

Dispersion-Cancelled and Dispersion-Sensitive Quantum Optical Coherence Tomography

Magued B. Nasr, Bahaa E. A. Saleh, Alexander V. Sergienko +1 more

Quantum optical coherence tomography (QOCT) makes use of an entangled twin-photon light source to carry out axial optical sectioning. We have probed the longitudinal structure of a sample comprising multiple surfaces in a dispersion-cancelled manner while simultaneously measuring the group-velocity dispersion of the interstitial media between the reflecting surfaces. The results of the QOCT experiments are compared with those obtained from conventional optical coherence tomography (OCT).

Optics Express•Jan 1, 2004•77 citations

Dispersion effects in quantum optical coherence tomography

Bahaa E. A. Saleh, Magued B. Nasr, Alexander V. Sergienko +1 more

Quantum optical coherence tomography makes use of a twin-photon light source and a HOM interferometer to carry out optical reflectometry. The axial structure of a sample comprising multiple surfaces can be probed in a dispersion-cancelled manner while simultaneously measuring the group-velocity dispersion of the interstitial media between the reflecting surfaces.

Frontiers in Optics•Jan 1, 2004•2 citations

Quantum-optical coherence tomography with dispersion cancellation

Ayman F. Abouraddy, Magued B. Nasr, Bahaa E. A. Saleh +2 more

We propose a technique, called quantum-optical coherence tomography (QOCT), for carrying out tomographic measurements with dispersion-cancelled resolution. The technique can also be used to extract the frequency-dependent refractive index of the medium. QOCT makes use of a two-photon interferometer in which a swept delay permits a coincidence interferogram to be traced. The technique bears a resemblance to classical optical coherence tomography (OCT). However, it makes use of a nonclassical entangled twin-photon light source that permits measurements to be made at depths greater than those accessible via OCT, which suffers from the deleterious effects of sample dispersion. Aside from the dispersion cancellation, QOCT offers higher sensitivity than OCT as well as an enhancement of resolution by a factor of two for the same source bandwidth. QOCT and OCT are compared using an idealized sample.

arXiv:quant-ph/0111140•Physical Review A•May 8, 2002•279 citations

Polarization-Sensitive Quantum-Optical Coherence Tomography with Entangled Photons

Zhi Gao Zhao, Kent A. Meyer, William B. Whitten +1 more

We present an experimental demonstration of polarization-sensitive quantum-optical coherence tomography that not only provides the advantages of dispersion cancellation and resolution doubling, but also the capability for determining information about the birefringence of the sample.

International Conference on Quantum Information•Jan 1, 2007•1 citation

Multi-reflection quantum-optical coherence tomography and experimental mimic with the classical optical field

Qian Li, Yifan Sun, Ling‐Jun Kong +1 more

Quantum optical coherence tomography (QOCT) is the non-classical counterpart of optical coherence tomography (OCT), by which quantum interference of entangled photon pairs is used to show some advantages over classical OCT. Currently, almost all research on the QOCT focuses on the case with two photons and a twofold improvement in axial resolution has been demonstrated. Here, we introduce the multiple reflections strategy into the QOCT scheme, referencing the multi-pass strategy of the sequential scheme in quantum metrology, and provide a theoretical framework for multi-reflection quantum-optical coherence tomography (MQOCT). According to such a scheme, when the incident light interacts with the sample N times, the axial resolution of MQOCT is theoretically enhanced by a factor of N compared to that of QOCT under the same spectral bandwidth while preserving the dispersion cancellation capability of QOCT. Furthermore, we present a classical optical analogy of MQOCT using P -beam correlated multi-mode broadband beams and experimentally validate it. The classical optical analogy of MQOCT theoretically has the same resolution enhancement capability and dispersion cancellation capability as MQOCT while avoiding the fragility issues associated with the quantum light source which is used in MQOCT.

Optics Express•Feb 13, 2025•0 citations

Demonstration of Fourier-domain Quantum Optical Coherence Tomography for a fast tomographic quantum imaging

Sylwia M. Kolenderska, de Brito, Crislane Vieira, Piotr Leszek Kolenderski

Using spectrally correlated photon pairs instead of classical laser light and coincidence detection instead of light intensity detection, Quantum Optical Coherence Tomography (Q-OCT) outperforms classical OCT in several experimental terms. It provides twice better axial resolution with the same spectral bandwidth and it is immune to even-order chromatic dispersion, including Group Velocity Dispersion responsible for the bulk of axial resolution degradation in the OCT images. Q-OCT has been performed in the time domain configuration, where one line of the two-dimensional image is acquired by axially translating the mirror in the interferometer's reference arm and measuring the coincidence rate of photons arriving at two single-photon-sensitive detectors. Although successful at producing resolution-doubled and dispersion-cancelled images, it is still relatively slow and cannot compete with its classical counterpart. Here, we experimentally demonstrate Q-OCT in a much faster Fourier-domain configuration, theoretically proposed in 2020, where the reference mirror is fixed and the joint spectrum is acquired by inserting long fibre spools in front of the detectors. We propose two joint spectrum pre-processing algorithms, aimed at compensating resolution-degrading effects within the setup. While the first one targets fibre spool dispersion, an effect specific to this configuration, the other one removes the effects leading to the weakening of even-order dispersion cancellation, the latter impossible to be mitigated in the time-domain alternative. Being additionally contrasted with both the time-domain approach and the conventional OCT in terms of axial resolution, imaging range and multilayer-object imaging, Fourier-domain Q-OCT is shown to be a significant step forward towards a practical and competitive solution in the OCT arena.

arXiv:2502.08372•Feb 12, 2025•3 citations
We present an experimental demonstration of quantum-optical coherence tomography. The technique makes use of an entangled twin-photon light source to carry out axial optical sectioning. It is compared to conventional optical coherence tomography. The immunity of the quantum version to dispersion, as well as a factor of 2 enhancement in resolution, is experimentally demonstrated.
We propose a technique, called quantum-optical coherence tomography (QOCT), for carrying out tomographic measurements with dispersion-cancelled resolution. The technique can also be used to extract the frequency-dependent refractive index of the medium. QOCT makes use of a two-photon interferometer in which a swept delay permits a coincidence interferogram to be traced. The technique bears a resemblance to classical optical coherence tomography (OCT). However, it makes use of a nonclassical entangled twin-photon light source that permits measurements to be made at depths greater than those accessible via OCT, which suffers from the deleterious effects of sample dispersion. Aside from the dispersion cancellation, QOCT offers higher sensitivity than OCT as well as an enhancement of resolution by a factor of two for the same source bandwidth. QOCT and OCT are compared using an idealized sample.
Quantum optical coherence tomography (QOCT) is the non-classical counterpart of optical coherence tomography (OCT), by which quantum interference of entangled photon pairs is used to show some advantages over classical OCT. Currently, almost all research on the QOCT focuses on the case with two photons and a twofold improvement in axial resolution has been demonstrated. Here, we introduce the multiple reflections strategy into the QOCT scheme, referencing the multi-pass strategy of the sequential scheme in quantum metrology, and provide a theoretical framework for multi-reflection quantum-optical coherence tomography (MQOCT). According to such a scheme, when the incident light interacts with the sample N times, the axial resolution of MQOCT is theoretically enhanced by a factor of N compared to that of QOCT under the same spectral bandwidth while preserving the dispersion cancellation capability of QOCT. Furthermore, we present a classical optical analogy of MQOCT using P -beam correlated multi-mode broadband beams and experimentally validate it. The classical optical analogy of MQOCT theoretically has the same resolution enhancement capability and dispersion cancellation capability as MQOCT while avoiding the fragility issues associated with the quantum light source which is used in MQOCT.
Using spectrally correlated photon pairs instead of classical laser light and coincidence detection instead of light intensity detection, Quantum Optical Coherence Tomography (Q-OCT) outperforms classical OCT in several experimental terms. It provides twice better axial resolution with the same spectral bandwidth and it is immune to even-order chromatic dispersion, including Group Velocity Dispersion responsible for the bulk of axial resolution degradation in the OCT images. Q-OCT has been performed in the time domain configuration, where one line of the two-dimensional image is acquired by axially translating the mirror in the interferometer's reference arm and measuring the coincidence rate of photons arriving at two single-photon-sensitive detectors. Although successful at producing resolution-doubled and dispersion-cancelled images, it is still relatively slow and cannot compete with its classical counterpart. Here, we experimentally demonstrate Q-OCT in a much faster Fourier-domain configuration, theoretically proposed in 2020, where the reference mirror is fixed and the joint spectrum is acquired by inserting long fibre spools in front of the detectors. We propose two joint spectrum pre-processing algorithms, aimed at compensating resolution-degrading effects within the setup. While the first one targets fibre spool dispersion, an effect specific to this configuration, the other one removes the effects leading to the weakening of even-order dispersion cancellation, the latter impossible to be mitigated in the time-domain alternative. Being additionally contrasted with both the time-domain approach and the conventional OCT in terms of axial resolution, imaging range and multilayer-object imaging, Fourier-domain Q-OCT is shown to be a significant step forward towards a practical and competitive solution in the OCT arena.