We present a general framework for sensitivity optimization in quantum parameter estimation schemes based on continuous (indirect) observation of a dynamical system. As an illustrative example, we analyze the canonical scenario of monitoring the position of a free mass or harmonic oscillator to detect weak classical forces. We show that our framework allows the consideration of sensitivity scheduling, as well as estimation strategies for nonstationary signals, leading us to propose corresponding generalizations of the standard quantum limit for force detection.
We present a general framework for sensitivity optimization in quantum parameter estimation schemes based on continuous (indirect) observation of a dynamical system. As an illustrative example, we analyze the canonical scenario of monitoring the position of a free mass or harmonic oscillator to detect weak classical forces. We show that our framework allows the consideration of sensitivity scheduling, as well as estimation strategies for nonstationary signals, leading us to propose corresponding generalizations of the standard quantum limit for force detection.
Quantum continuous measurement strategies are an essential element in many modern sensing technologies, leading to potentially enhanced estimation of unknown physical parameters. In such schemes, continuous monitoring of the quantum system, which encodes the parameters of interest, gives rise to different quantum trajectories conditioned on the measurement outcomes which carry information on the parameters themselves. Importantly, different trajectories carry different amounts of information, i.e., they are more or less sensitive to the unknown parameters of interest. In this work, we propose an approach on how to systematically engineer the quantum open-system dynamics in order to increase the probability of obtaining trajectories of high sensitivity. We focus on the simplest case scenario of a single two-level system interacting with ancillas, which are in turn measured using the discretized version of continuous monitoring. We analyze the performance of our protocol and demonstrate that it may lead to a substantial enhancement of sensitivity, as quantified by the classical Fisher information, even when applied to such small system sizes, holding the promise of direct implementation in state-of-the-art experimental platforms and large, complex many-body systems.
High-sensitivity accelerometers and gravimeters, achieving the ultimate limits of measurement sensitivity are key tools for advancing both fundamental and applied physics. While numerous platforms have been proposed to achieve this goal, from atom interferometers to optomechanical systems, all of these studies neglect the effects of intrinsic quantum uncertainty in time estimation. Starting from the Hamiltonian of a generic linear quantum sensor, we derive the two-parameter quantum Fisher information matrix and establish the corresponding Cram'er-Rao bound, treating time as an uncertain (nuisance) parameter. Our analysis reveals a fundamental coupling between time and signal estimation that inherently degrades measurement sensitivity, with the standard single-parameter quantum limit recovered only at specific interrogation times or under special decoupling conditions. We then apply these results to an optomechanical gravimeter and explicitly derive an optimal decoupling condition under which the effects of time uncertainty are averaged out in a continuous measurement scheme. Our approach is general and can be readily extended to a broad class of quantum sensors.
Quantum Parameter Estimation (QPE) is important from the perspective of both fundamental quantum research and various practical applications of quantum technologies such as for developing optimal quantum control strategies. Standard and traditional methods for QPE involve projective measurements on thousands of identically prepared quantum systems. However, these methods face limitations, particularly in terms of the required number of samples and the associated experimental resources. In this work, we present a novel method for precise QPE that diverges from conventional techniques, employs continuous measurements, and enables accurate QPE with a single quantum trajectory. In an application, we demonstrate the use of the method for the task of parameter estimation and force sensing of a levitated nanoparticle.
We derive a quantum Cramér-Rao bound (QCRB) on the error of estimating a time-changing signal. The QCRB provides a fundamental limit to the performance of general quantum sensors, such as gravitational-wave detectors, force sensors, and atomic magnetometers. We apply the QCRB to the problem of force estimation via continuous monitoring of the position of a harmonic oscillator, in which case the QCRB takes the form of a spectral uncertainty principle. The bound on the force-estimation error can be achieved by implementing quantum noise cancellation in the experimental setup and applying smoothing to the observations.
Abstract Quantum systems are promising candidates for sensing of weak signals as they can be highly sensitive to external perturbations, thus providing excellent performance when estimating parameters of external fields. However, when trying to detect weak signals that are hidden by background noise, the signal-to-noise ratio is a more relevant metric than raw sensitivity. We identify, under modest assumptions about the statistical properties of the signal and noise, the optimal quantum control to detect an external signal in the presence of background noise using a quantum sensor. Interestingly, for white background noise, the optimal solution is the simple and well-known spin-locking control scheme. Using numerical techniques, we further generalize these results to the case of background noise with a Lorentzian spectrum. We show that for increasing correlation time, pulse based sequences, such as CPMG, are also close to the optimal control for detecting the signal, with the crossover dependent on the signal frequency. These results show that an optimal detection scheme can be easily implemented in near-term quantum sensors without the need for complicated pulse shaping.
Quantum parameter estimation has been long pursued in various physics areas, such as quantum optics, quantum information processing, gravitational wave detection, and so on. Generally, the quantum system dynamics is usually assumed to be fixed and the system is closed, the highest precision can be achieved by preparing the optimal probe state and performing the quantum measurement based on ideal basis that saturates the quantum Cramer-Rao inequality. However, how to extend this problem to a more general open quantum system is still an open question. In this paper, we apply the optimal control theory, Pontrygin optimal principle, to enhance the parameter estimation precision in open quantum systems. The control laws and the control algorithm are exactly presented. Simulation results demonstrated the efficiency of the optimal control laws.