arXiv:physics/0611014 · Physical Review A

Synchronous optical pumping of quantum revival beats for atomic magnetometry

Scott J. Seltzer, Parker Meares, Michael V. Romalis

Published May 30, 2007• 77 citations
arXivHTMLPDF

Abstract

We observe quantum beats with periodic revivals due to nonlinear spacing of Zeeman levels in the ground state of potassium atoms, and demonstrate their synchronous optical pumping by double modulation of the pumping light at the Larmor frequency and the revival frequency. We show that synchronous pumping increases the degree of spin polarization by a factor of 4. As a practical example, we explore the application of this double-modulation technique to atomic magnetometers operating in the geomagnetic field range, and find that it can increase the sensitivity and reduce magnetic-field-orientation-dependent measurement errors endemic to alkali-metal magnetometers.

DOI
10.1103/physreva.75.051407

Related papers

Magneto-optic spectroscopy with linearly polarized modulated light: Theory and experiment

G. Bevilacqua, Evelina Breschi

We investigate the polarization modulation between two linear orthogonal states of the laser beam that synchronously pumps time-dependent atomic alignment in caesium atoms exposed to a static magnetic field. Because of the atomic alignment symmetry two independent groups of resonances can be distinguished in the transmitted light: when modulation frequency matches either the Larmor frequency or its second harmonics, ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$, respectively. We report on our experiments, and discuss a model that perfectly reproduces the observed spectra. We have observed that the amplitudes and linewidths of resonances at ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$ show magnetic-field direction dependence. This peculiar behavior makes our approach interesting for future application to atomic magnetometry, in view of a dead-zone free high-sensitivity magnetometer.

Physical Review A•Jun 18, 2014•16 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Simultaneous Observation of Nonlinear Magneto-Optical Rotation in the Temporal and Spectral Domains with an Electro-Optic Frequency Comb

Nathanial Wilson, Nicolas Bourbeau Hébert, Christopher Perrella +4 more

Highly sensitive magnetic field measurements are desirable for medical diagnoses and imaging, as well as research in geomagnetism and fundamental physics. Atomic magnetometers measure the Larmor frequency of an alkali vapor, and their sensitivity depends on generating a high degree of ground-state coherence in the atomic population via optical pumping. This study uses an electro-optic frequency comb to probe a broad spectral region, yielding measurements of the Larmor frequency that are both temporally and spectrally resolved. The techniques developed here allow real-time analysis of the degree of polarization of the atomic ensemble, and the avenues by which this polarization is probed.

Physical Review Applied•Sep 7, 2018•17 citations

Improving sensitivity of an amplitude-modulated magneto-optical atomic magnetometer using squeezed light

Jiahui Li, Irina V. Novikova

We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].

arXiv:2207.12962•Journal of the Optical Society of America B•Oct 5, 2022•15 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•12 citations

Optical magnetometer: Quantum resonances at pumping repetition rate of 1/n of the Larmor frequency

Andrei Ben-Amar Baranga, Alexander Gusarov, Gennady A. Koganov +2 more

The response of a spin exchange relaxation free atomic magnetometer to a repetitive short-pulsed pump was investigated. Quantum sub-resonances at a repetition rate of 1/n of the Larmor frequency of the magnetic field inside the shield are experimentally observed and theoretically explained. This is a type of synchronization phenomenon. Investigations in single alkali atom cells and mixed alkali atoms of K and Rb are presented. In the latter, one species is pumped while the probe is on the other species polarized by spin exchange. The effect of spin destruction, spin exchange, and collisions is studied in order to account for the width of the resonances. Quantum calculations of a three-level Λ model for this phenomenon exhibit a dip at the resonance frequency in the absorption spectrum for both cases of pulsed and cw pump modes and an evidence for electromagnetically induced transparency.

arXiv:2002.08631•Journal of Applied Physics•Nov 4, 2020•6 citations
We observe quantum beats with periodic revivals due to nonlinear spacing of Zeeman levels in the ground state of potassium atoms, and demonstrate their synchronous optical pumping by double modulation of the pumping light at the Larmor frequency and the revival frequency. We show that synchronous pumping increases the degree of spin polarization by a factor of 4. As a practical example, we explore the application of this double-modulation technique to atomic magnetometers operating in the geomagnetic field range, and find that it can increase the sensitivity and reduce magnetic-field-orientation-dependent measurement errors endemic to alkali-metal magnetometers.
We investigate the polarization modulation between two linear orthogonal states of the laser beam that synchronously pumps time-dependent atomic alignment in caesium atoms exposed to a static magnetic field. Because of the atomic alignment symmetry two independent groups of resonances can be distinguished in the transmitted light: when modulation frequency matches either the Larmor frequency or its second harmonics, ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$, respectively. We report on our experiments, and discuss a model that perfectly reproduces the observed spectra. We have observed that the amplitudes and linewidths of resonances at ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$ show magnetic-field direction dependence. This peculiar behavior makes our approach interesting for future application to atomic magnetometry, in view of a dead-zone free high-sensitivity magnetometer.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Highly sensitive magnetic field measurements are desirable for medical diagnoses and imaging, as well as research in geomagnetism and fundamental physics. Atomic magnetometers measure the Larmor frequency of an alkali vapor, and their sensitivity depends on generating a high degree of ground-state coherence in the atomic population via optical pumping. This study uses an electro-optic frequency comb to probe a broad spectral region, yielding measurements of the Larmor frequency that are both temporally and spectrally resolved. The techniques developed here allow real-time analysis of the degree of polarization of the atomic ensemble, and the avenues by which this polarization is probed.
We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
The response of a spin exchange relaxation free atomic magnetometer to a repetitive short-pulsed pump was investigated. Quantum sub-resonances at a repetition rate of 1/n of the Larmor frequency of the magnetic field inside the shield are experimentally observed and theoretically explained. This is a type of synchronization phenomenon. Investigations in single alkali atom cells and mixed alkali atoms of K and Rb are presented. In the latter, one species is pumped while the probe is on the other species polarized by spin exchange. The effect of spin destruction, spin exchange, and collisions is studied in order to account for the width of the resonances. Quantum calculations of a three-level Λ model for this phenomenon exhibit a dip at the resonance frequency in the absorption spectrum for both cases of pulsed and cw pump modes and an evidence for electromagnetically induced transparency.