Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0510166 · Optics Letters

Detecting magnetically guided atoms with an optical cavity

Albrecht Haase, Björn Hessmo, Jörg Schmiedmayer

Published Jan 15, 2006• 40 citations
arXivHTMLPDF

Abstract

We show that a low-finesse cavity can be efficient for detecting neutral atoms. The low finesse can be compensated for by decreasing the mode waist of the cavity. We have used a near-concentric resonator with a beam waist of 12 microm and a finesse of only 1100 to detect magnetically guided Rb atoms with a detection sensitivity of 0.1 atom in the mode volume. For future experiments on single-atom detection and cavity QED applications, it should be beneficial to use miniaturized optical resonators integrated on atom chips.

DOI
10.1364/ol.31.000268

Related papers

Detecting Neutral Atoms on an Atom Chip

Marco Wilzbach, Albrecht Haase, Michael Schwarz +8 more

This chapter contains sections titled: Introduction Detecting Single Atoms Measuring the Scattered Light: Fluorescence Detection Measuring the Driving Field Absorption on Resonance Refraction Cavities Absorption on Resonance Refraction Many Atoms in a Cavity Concentric Cavity Miniaturization Properties of Fiber Cavities Loss Mechanisms for a Cavity Losses due to the Gap Length Losses due to Transversal Misalignment Losses due to Angular Misalignment Fresnel Reflections Other Fiber Optical Components for the Atom Chip Fluorescence and Absorption Detectors A Single Mode Tapered Lensed Fiber Dipole Trap Integration of Fibers on the Atom Chip Building Fiber Cavities The SU-8 Resist Test of the SU-8 Structure Pilot Test for Atom Detection with Small Waists Dropping Atoms through a Concentric Cavity Detecting Magnetically Guided Atoms Conclusion References

Wiley eBooks•Jan 26, 2007•1 citation

Microcavities on atom chips for single-atom detection

Albrecht Haase, Michael Schwarz, Marco Wilzbach +5 more

To demonstrate the feasibility of detecting magnetically trapped neutral atoms with "bad" cavities, a macroscopic nearly concentric cavity is built. Using this cavity,atoms guided with a free-standing current-carrying wire are detected.

European Quantum Electronics Conference (EQEC)•Jan 18, 2006•0 citations

Single atoms coupled to a near-concentric cavity

Chi Huan Nguyen, Adrian Nugraha Utama, Nick Lewty +5 more

Concentric cavities can lead to strong photon-atom coupling without a need for high finesse or small physical-cavity volume. In this proof-of-principle experiment we demonstrate coupling of single Rb atoms to an 11-mm-long near-concentric cavity with a finesse $F=138(2)$. Operating the cavity $1.7(1)\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{m}$ shorter than the critical length, we observe an atom-cavity coupling constant ${g}_{0}=2\ensuremath{\pi}\ifmmode\times\else\texttimes\fi{}5.0(2)$ MHz which exceeds the natural dipole decay rate $\ensuremath{\gamma}$ by a factor of ${g}_{0}/\ensuremath{\gamma}=1.7(1)$.

arXiv:1706.01256•Physical Review A•Sep 13, 2017•12 citations

Real-time detection of individual atoms falling through a high-finesse optical cavity

Hideo Mabuchi, Q. A. Turchette, Michael Chapman +1 more

The enhanced coupling between atoms and photons inside a high-finesse optical cavity provides a novel basis for optical measurements that continuously monitor atomic degrees of freedom. We describe an experiment in which cavity quantum-electrodynamic effects are utilized for real-time detection of individual atoms falling through an optical cavity after being dropped from a magneto-optical trap. Our technique permits experiments that are triggered by the presence of a single optimally coupled atom within the cavity mode volume.

Optics Letters•Sep 1, 1996•182 citations

A single-atom detector integrated on an atom chip: fabrication, characterization and application

Dennis Heine, Wolfgang Rohringer, D Fischer +7 more

We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.

arXiv:1002.1573•New Journal of Physics•Sep 9, 2010•30 citations

Single atom detection on an atom chip with integrated optics

Marco Wilzbach

The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.

•Jan 1, 2007•0 citations
We show that a low-finesse cavity can be efficient for detecting neutral atoms. The low finesse can be compensated for by decreasing the mode waist of the cavity. We have used a near-concentric resonator with a beam waist of 12 microm and a finesse of only 1100 to detect magnetically guided Rb atoms with a detection sensitivity of 0.1 atom in the mode volume. For future experiments on single-atom detection and cavity QED applications, it should be beneficial to use miniaturized optical resonators integrated on atom chips.
This chapter contains sections titled: Introduction Detecting Single Atoms Measuring the Scattered Light: Fluorescence Detection Measuring the Driving Field Absorption on Resonance Refraction Cavities Absorption on Resonance Refraction Many Atoms in a Cavity Concentric Cavity Miniaturization Properties of Fiber Cavities Loss Mechanisms for a Cavity Losses due to the Gap Length Losses due to Transversal Misalignment Losses due to Angular Misalignment Fresnel Reflections Other Fiber Optical Components for the Atom Chip Fluorescence and Absorption Detectors A Single Mode Tapered Lensed Fiber Dipole Trap Integration of Fibers on the Atom Chip Building Fiber Cavities The SU-8 Resist Test of the SU-8 Structure Pilot Test for Atom Detection with Small Waists Dropping Atoms through a Concentric Cavity Detecting Magnetically Guided Atoms Conclusion References
Concentric cavities can lead to strong photon-atom coupling without a need for high finesse or small physical-cavity volume. In this proof-of-principle experiment we demonstrate coupling of single Rb atoms to an 11-mm-long near-concentric cavity with a finesse F=138(2)F=138(2)F=138(2). Operating the cavity $1.7(1)\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{m}$ shorter than the critical length, we observe an atom-cavity coupling constant ${g}_{0}=2\ensuremath{\pi}\ifmmode\times\else\texttimes\fi{}5.0(2)$ MHz which exceeds the natural dipole decay rate $\ensuremath{\gamma}$ by a factor of ${g}_{0}/\ensuremath{\gamma}=1.7(1)$.
The enhanced coupling between atoms and photons inside a high-finesse optical cavity provides a novel basis for optical measurements that continuously monitor atomic degrees of freedom. We describe an experiment in which cavity quantum-electrodynamic effects are utilized for real-time detection of individual atoms falling through an optical cavity after being dropped from a magneto-optical trap. Our technique permits experiments that are triggered by the presence of a single optimally coupled atom within the cavity mode volume.
We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.
The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.