Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0404076 · Journal of the Optical Society of America B

Modulation-induced frequency shifts in a coherent-population-trapping-based atomic clock

David F. Phillips, Irina V. Novikova, Christine Y.-T. Wang, Ronald Lee Walsworth, Michael Crescimanno

Published Feb 1, 2005• 26 citations
arXivHTMLPDF

Abstract

We investigate systematic errors associated with a common modulation technique used for phase-sensitive detection of a coherent-population-trapping (CPT) resonance. In particular, we show that modification of the CPT resonance line shape due to the presence of off-resonant fields leads to frequency shifts that may limit the stability of CPT-based atomic clocks. We also demonstrate that an alternative demodulation technique greatly reduces these effects.

DOI
10.1364/josab.22.000305

Related papers

Frequency shift caused by the line-shape asymmetry of the resonance of coherent population trapping

Valeriy I. Yudin, M. Yu. Basalaev, А. В. Тайченачев +5 more

We theoretically study the frequency shift in atomic clocks caused by the line-shape asymmetry of coherent population trapping (CPT) resonance in a bichromatic laser field. This asymmetry arises due to the inequality of the resonant spectral components and nonzero one-photon detuning. The line-shape-asymmetry-induced shift depends on the intensity of the resonant fields, which leads to a degradation in long-term stability due to fluctuations of the laser field parameters. A frequency stabilization based on the harmonic modulation of two-photon detuning is considered. It is shown that the use of a high-frequency modulation (compared to the CPT resonance width, i.e., the Pound-Drever-Hall regime) makes it possible to significantly suppress this shift (by one to two orders of magnitude).

Physical Review A•Jul 10, 2023•17 citations

Continuous light-shift correction in modulated coherent population trapping clocks

Vishal Shah, Vladislav P. Gerginov, Peter D. D. Schwindt +3 more

The authors demonstrate a simple technique to significantly improve the long-term frequency stability of atomic clocks based on coherent population trapping (CPT). In this technique, the CPT fields are created by a modulated diode laser and a slow servo is used to actively tune the laser modulation index to a value where the light shift vanishes. The observed clock frequency at this modulation index is given by the rubidium hyperfine frequency when no light fields are present, and this makes the clock frequency largely insensitive to variations in laser properties. In addition to reducing stringent requirements on the long-term stabilities of laser temperature, laser frequency, and rf modulation power, this technique may also significantly reduce frequency drifts related to laser aging. In the experiment, they demonstrate improvement by over one order of magnitude in the stability of a clock that is limited by light-shift-induced frequency drifts.

Applied Physics Letters•Oct 9, 2006•82 citations

Modulation-dependent frequency shifts in CPT-based atomic clocks

Irina V. Novikova, David F. Phillips, C. Waiig +2 more

When frequency modulation is used to detect coherent population trapping resonances, shifts proportional to the modulation parameters and the laser detuning from the excited state are observed. These shifts limit the stability of CPT-based atomic clocks.

Conference on Lasers and Electro-Optics•Jan 1, 2004•0 citations

Dynamic Continuous-Wave Spectroscopy of Coherent Population Trapping at Phase-Jump Modulation

M. Yu. Basalaev, V.I. Yudin, A.V. Taichenachev +5 more

A method of dynamic continuous-wave spectroscopy of coherent population trapping (CPT) resonances using phase modulation of the jump type is developed. The time evolution of the spectroscopic signal is investigated. A method for the formation of an error signal for frequency stabilization is proposed. We show that our approach has a reduced sensitivity to the line-shape asymmetry of the CPT resonance. The experimental results are in good qualitative agreement with theoretical predictions based on a mathematical model of a three-level $\mathrm{\ensuremath{\Lambda}}$ system in a bichromatic field. This method can be used in atomic frequency standards (including chip-scale atomic clocks).

arXiv:1911.00575•Physical Review Applied•Mar 24, 2020•19 citations

Active light shift stabilization in modulated CPT clocks.

Vishal Shah, Peter D. D. Schwindt, Vladislav P. Gerginov +3 more

We demonstrate a simple technique to significantly improve the long-term frequency stability in atomic clocks based on coherent population trapping (CPT). In this technique, a servo is used to control the local oscillator power level in such a way that the optical spectrum generates no net light shift. This ensures that the clock frequency is always given by the atomic resonance frequency that is not perturbed by the incident light fields.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•9 citations

Stabilization method for atomic clocks to detect the maximum coherent-population-trapping resonance signal

Yusuke Odagiri, Satoshi Hatano, Yuichiro Yano +3 more

Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.

Japanese Journal of Applied Physics•Jun 1, 2025•2 citations
We investigate systematic errors associated with a common modulation technique used for phase-sensitive detection of a coherent-population-trapping (CPT) resonance. In particular, we show that modification of the CPT resonance line shape due to the presence of off-resonant fields leads to frequency shifts that may limit the stability of CPT-based atomic clocks. We also demonstrate that an alternative demodulation technique greatly reduces these effects.
We theoretically study the frequency shift in atomic clocks caused by the line-shape asymmetry of coherent population trapping (CPT) resonance in a bichromatic laser field. This asymmetry arises due to the inequality of the resonant spectral components and nonzero one-photon detuning. The line-shape-asymmetry-induced shift depends on the intensity of the resonant fields, which leads to a degradation in long-term stability due to fluctuations of the laser field parameters. A frequency stabilization based on the harmonic modulation of two-photon detuning is considered. It is shown that the use of a high-frequency modulation (compared to the CPT resonance width, i.e., the Pound-Drever-Hall regime) makes it possible to significantly suppress this shift (by one to two orders of magnitude).
The authors demonstrate a simple technique to significantly improve the long-term frequency stability of atomic clocks based on coherent population trapping (CPT). In this technique, the CPT fields are created by a modulated diode laser and a slow servo is used to actively tune the laser modulation index to a value where the light shift vanishes. The observed clock frequency at this modulation index is given by the rubidium hyperfine frequency when no light fields are present, and this makes the clock frequency largely insensitive to variations in laser properties. In addition to reducing stringent requirements on the long-term stabilities of laser temperature, laser frequency, and rf modulation power, this technique may also significantly reduce frequency drifts related to laser aging. In the experiment, they demonstrate improvement by over one order of magnitude in the stability of a clock that is limited by light-shift-induced frequency drifts.
A method of dynamic continuous-wave spectroscopy of coherent population trapping (CPT) resonances using phase modulation of the jump type is developed. The time evolution of the spectroscopic signal is investigated. A method for the formation of an error signal for frequency stabilization is proposed. We show that our approach has a reduced sensitivity to the line-shape asymmetry of the CPT resonance. The experimental results are in good qualitative agreement with theoretical predictions based on a mathematical model of a three-level $\mathrm{\ensuremath{\Lambda}}$ system in a bichromatic field. This method can be used in atomic frequency standards (including chip-scale atomic clocks).
Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.