Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0606494 · IEEE Transactions on Applied Superconductivity

Niobium Hot Electron Bolometer Development for a Submillimeter Heterodyne Array Camera

Matthew O. Reese, Daniel F. Santavicca, Luigi Frunzio, D. E. Prober

Published Jun 1, 2007• 10 citations
arXivHTMLPDF

Abstract

We are developing a proof-of-concept for a diffusion cooled hot electron bolometer (HEB) array submillimeter camera. The ultimate objective is to create a working 64 pixel array with the University of Arizona for use on the Heinrich Hertz Telescope. We have fabricated Nb HEBs using a novel angle deposition process. We have characterized these devices using heterodyne mixing at 20 GHz. We also report on optimizations in the fabrication process that improve device performance and a dc screening test for device quality. Using this process, HEBs with a sharp resistive transition (<300 mK) can consistently be produced. These devices have good suppression of superconductivity in the contact pads, with a pad transition ~1 K below the main bridge transition. Furthermore, the bandwidth was investigated above and below the pad transition and found to be ~15% larger for 400 nm long bridges with non- superconducting contact pads.

DOI
10.1109/tasc.2007.898195

Related papers

Superconducting hot electron bolometers for terahertz sensing

Matthew O. Reese

Superconducting Hot Electron Bolometers (HEBs) are good candidates for detecting weak signals in the submillimeter or terahertz range. In this thesis work, a novel fabrication method was developed to make two types of niobium HEBs for different applications. HEBs were designed, fabricated, and then characterized at dc, microwave, and THz frequencies. The first type is a diffusion-cooled HEB, made with a short bridge that determines its cooling time. In this thesis, bridges were typically 400 nm long with bandwidths of about 1 GHz. These diffusion-cooled HEBs were developed as part of a collaboration with the University of Arizona (UA), to develop a proof-of-concept heterodyne array submillimeter camera. Devices were fabricated on thin fused quartz and silica substrates for waveguide coupling in the UA system for the astrophysically interesting 345 and 810 GHz atmospheric windows. The goal of this collaboration is to provide a basis of comparison between Nb diffusion-cooled HEB mixers and superconductorinsulator-superconductor mixers at these frequencies. The second type is a phonon-cooled HEB, made with a ∼3 µm long bridge. Its thermal response is dictated by the electron-phonon relaxation time. These devices were developed in collaboration with Prof. C. Schmuttenmaer’s lab in the Yale Chemistry department, Prof. G. Blake at Caltech,

•Jan 1, 2006•7 citations

Fabrication and Receiver Measurements of a Diffusion-cooled Hot-electron Bolometer at 800 GHz

J. Stodolka, Kristof J. P. Jacobs

We present a fabrication process for diffusion-cooled niobium hot-electron bolometers using a self-aligned process with gold as an initial protection layer and aluminum as an etch mask that is removed by a wet etch. This process proves to be reproducible and has a yield of ~70 % per batch. Great care has been taken to avoid processing temperatures above 120 °C to minimize degradation of the Nb film. We have performed heterodyne measurements of an HEB in a fixed tuned waveguide mixer at 804 GHz and at an IF-range from 1-2 GHz. The approximate dimensions of the bridge are 240 x 200 x 14 nm3. The Niobium bridge has a critical temperature of 6.0 K and a normal state resistance of 16.5 Ω. A standard Y-factor measurement leads to a minimum noise temperature of 1200 K at 1 GHz IF. The coupled LO-power is estimated by the isothermal method to be 21 nW. Introduction Superconducting Hot-Electron-Bolometers (HEB) utilizing thin superconducting films have become established as sensitive mixers in the THz region. The thermal response time τ can be very small if the superconductor is thin enough that only the electron gas is heated and the cooling is fast enough. The bolometers described in this paper are cooled by out-diffusion of the hot electrons in normal conducting heat sinks (diffusion-cooled HEB) rather than interactions with phonons of the lattice (phononcooled HEB) [1]. To meet the requirements for astronomical applications such as SOFIA, thermal response times down to several picoseconds are needed to get intermediate frequencies up to 10 GHz. Because of τ ~ L [1] the dimensions of the bolometer bridge have to be very small. We have fabricated diffusion-cooled HEBs with short (L<300 nm) and narrow (<200 nm) bridges consisting of thin (10-14 nm) Niobium (Nb) on z-cut quartz substrates. The normal conducting heat sinks consist of 70 nm Gold (Au). In the following paragraph 1 e-mail: stodolka@ph1.uni-koeln.de we discuss problems and merits of several approaches for the fabrication of diffusioncooled HEBs. Device Fabrication Aside from a good reproducibility, the essential requirement for the fabrication of a diffusion-cooled HEB is a good transparency of the interface between the heat sinks and the material of the bolometer bridge. A thermal resistance results in a slower out-diffusion of the hot electrons and thus increases the effective bridge length and thermal response time. Defining the bolometer bridge by lift-off with subsequent deposition of the heat sinks (Fig. 1) [2] has the major disadvantage of high requirements for the overlap accuracy of the Electron-Beam-Lithography (EBL) system to position the heat sinks on the contact areas of the bridge. A solution is offered by the self-aligned process (Fig. 2). Here, the substrate is covered with a blanket layer of Nb. The heat sinks and a metal strip of the width of the bolometer bridge are deposited in succession. The bridge is now etched out of the blanket layer by using reactive ion etching (RIE) where the heat sinks and the metal strip serve as etch masks: the spacing between the heat sinks determines the bridge length while the metal strip defines the width. The overlap between Nb and Au heat sinks is large. Fig. 1: Outline of HEB fabrication by lift off (top view) a) Bolometer bridge defined by liftoff. b) Deposition of the heat sinks. The contact area (shaded) to the heat sinks is small. bolometer bridge

•Dec 1, 2001•2 citations

Aluminum hot-electron bolometer mixers at submillimeter wavelengths

Anders J. Skalare, William R. McGrath, P. M. Echternach +4 more

Diffusion-cooled aluminum hot-electron bolometer (HEB) mixers are of interest for low-noise high resolution THz-frequency spectroscopy within astrophysics. Al HEB mixers offer operation with an order of magnitude less local oscillator power, higher intermediate frequency bandwidth and potentially lower noise than competing devices made from other materials. We report on mixer experiments at 618 GHz with devices fabricated from films with sheet resistances in the range from about 55 /spl Omega/ down to about 9 /spl Omega/ per square. Intermediate frequency bandwidths of up to 3 GHz were measured (1 /spl mu/m long device), with absorbed local oscillator power levels of 0.5 to 6 nW and mixer conversion up to -21.5 dB. High input coupling efficiency implies that the electrons in the device are able to thermalize before escaping from the device. It was found that the long coherence length complicates mixer operations due to the proximity of the contact pads. Also, saturation at the IF frequency may be a concern for this type of device, and warrants further studies.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•17 citations

Tantalum Hot-Electron Bolometers for Low-Noise Heterodyne Receivers

Anders J. Skalare, William R. McGrath, Bruce Bumble +1 more

We describe superconducting diffusion-cooled hot-electron bolometers that were fabricated fromtantalum films grown on a thin niobium seed layer. The seed layer promotes single-phase growth of the Ta films, resulting in high-quality bolometers with transition temperatures up to 2.35 K and transition widths of less than 0.2 K. An S-parameter measurement set-up in a He-3 cryostat was used to measure device impedance versus frequency of a 400 nm long device at a temperature of 400 mK. It is shown that a 3 dB roll-off frequency of about 1 GHz can be achieved when the device resistance matches the impedance of the embedding network (no electrothermal feedback). This would lead to a prediction of 16 GHz for a 100 nm device, and indicates that a heterodyne mixer using a Ta HEB should be able to operate at several GHz even with a significant amount of electrothermal feedback.

•Mar 26, 2002•1 citation

NbN FILM DEVELOPMENT FOR PHONON-COOLED HEB DEVICES

Eyal Gerecht, Ashok K. Bhupathiraju, Erich N. Grossman +4 more

Superconducting Hot-electron Bolometric (HE.B) mixers employing thin films ofNbN have become the devices of choice for heterodyne detection at tera,hertz frequen- cies. HEB mixers are inherently insensitive to the bandgap frequency of the superconducting material used in the device, in contrast to SIS mixers,. We have developed a fabrication pro- cess for thin NbN films at the National Institute of Standards and Technology in Boulder, CO. A two-fold approach can be taken. The first is to maximize the critical temperature of the superconducting device by growing thicker films at the expense of IF bandwidth, whereas the second approach focuses on maximizing the IF bandwidth at the expense of the critical tem- perature. So far, we have developed a film-deposition process utilizing our DC reactive mag- netron sputtering chamber. By current-biasing the RF plasma in a mixture of Ar and N2, while using a Nb target, we can control the film stoichiometry and produce films with thicknesses of 5 nm. The films are deposited on MgO substrates that are heated to about 800 °C during depo- sition. A typical critical temperature (TO is about 10 K and the transition width is very small (0.5 K). The films are evaluated by measuring their superconducting characteristics as well as their thickness and surface roughness by means of AFM analysis. Phonon-cooled HEB devices are fabricated from the films to study their performance as HEB mixers. The device fabrication process at UMass/Amherst involves lift-off lithography of the antenna (gold), and Reactive ion etching (R1E) or wet etching of the NbN. The I-V char- acteristics and noise temperatures of the devices were measured in order to determine their quality for PHEB applications.

•Mar 1, 2002•1 citation

Low-noise and wideband hot-electron superconductive mixers for THz frequencies

Boris S. Karasik, Anders J. Skalare, Rolf A. Wyss +5 more

Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range 1.1-2.5 THz. The mixer device is a 0.15-03 /spl mu/m microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be /spl les/3000 K at 2.5 THz and the mixer IF bandwidth is /spl ap/9-10 GHz for a 0.1 /spl mu/m long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20-100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated The HEB mixer Is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// (YBCO) HEB are also discussed. The expected LO power of 1-10 /spl mu/W and SSB noise temperature of /spl ap/2000 K may make this mixer attractive for various remote sensing applications.

IEEE International Conference on Terahertz Electronics (THz)•Nov 27, 2002•5 citations
We are developing a proof-of-concept for a diffusion cooled hot electron bolometer (HEB) array submillimeter camera. The ultimate objective is to create a working 64 pixel array with the University of Arizona for use on the Heinrich Hertz Telescope. We have fabricated Nb HEBs using a novel angle deposition process. We have characterized these devices using heterodyne mixing at 20 GHz. We also report on optimizations in the fabrication process that improve device performance and a dc screening test for device quality. Using this process, HEBs with a sharp resistive transition (<300 mK) can consistently be produced. These devices have good suppression of superconductivity in the contact pads, with a pad transition ~1 K below the main bridge transition. Furthermore, the bandwidth was investigated above and below the pad transition and found to be ~15% larger for 400 nm long bridges with non- superconducting contact pads.
Superconducting Hot Electron Bolometers (HEBs) are good candidates for detecting weak signals in the submillimeter or terahertz range. In this thesis work, a novel fabrication method was developed to make two types of niobium HEBs for different applications. HEBs were designed, fabricated, and then characterized at dc, microwave, and THz frequencies. The first type is a diffusion-cooled HEB, made with a short bridge that determines its cooling time. In this thesis, bridges were typically 400 nm long with bandwidths of about 1 GHz. These diffusion-cooled HEBs were developed as part of a collaboration with the University of Arizona (UA), to develop a proof-of-concept heterodyne array submillimeter camera. Devices were fabricated on thin fused quartz and silica substrates for waveguide coupling in the UA system for the astrophysically interesting 345 and 810 GHz atmospheric windows. The goal of this collaboration is to provide a basis of comparison between Nb diffusion-cooled HEB mixers and superconductorinsulator-superconductor mixers at these frequencies. The second type is a phonon-cooled HEB, made with a ∼3 µm long bridge. Its thermal response is dictated by the electron-phonon relaxation time. These devices were developed in collaboration with Prof. C. Schmuttenmaer’s lab in the Yale Chemistry department, Prof. G. Blake at Caltech,
We present a fabrication process for diffusion-cooled niobium hot-electron bolometers using a self-aligned process with gold as an initial protection layer and aluminum as an etch mask that is removed by a wet etch. This process proves to be reproducible and has a yield of ~70 % per batch. Great care has been taken to avoid processing temperatures above 120 °C to minimize degradation of the Nb film. We have performed heterodyne measurements of an HEB in a fixed tuned waveguide mixer at 804 GHz and at an IF-range from 1-2 GHz. The approximate dimensions of the bridge are 240 x 200 x 14 nm3. The Niobium bridge has a critical temperature of 6.0 K and a normal state resistance of 16.5 Ω. A standard Y-factor measurement leads to a minimum noise temperature of 1200 K at 1 GHz IF. The coupled LO-power is estimated by the isothermal method to be 21 nW. Introduction Superconducting Hot-Electron-Bolometers (HEB) utilizing thin superconducting films have become established as sensitive mixers in the THz region. The thermal response time τ can be very small if the superconductor is thin enough that only the electron gas is heated and the cooling is fast enough. The bolometers described in this paper are cooled by out-diffusion of the hot electrons in normal conducting heat sinks (diffusion-cooled HEB) rather than interactions with phonons of the lattice (phononcooled HEB) [1]. To meet the requirements for astronomical applications such as SOFIA, thermal response times down to several picoseconds are needed to get intermediate frequencies up to 10 GHz. Because of τ ~ L [1] the dimensions of the bolometer bridge have to be very small. We have fabricated diffusion-cooled HEBs with short (L<300 nm) and narrow (<200 nm) bridges consisting of thin (10-14 nm) Niobium (Nb) on z-cut quartz substrates. The normal conducting heat sinks consist of 70 nm Gold (Au). In the following paragraph 1 e-mail: stodolka@ph1.uni-koeln.de we discuss problems and merits of several approaches for the fabrication of diffusioncooled HEBs. Device Fabrication Aside from a good reproducibility, the essential requirement for the fabrication of a diffusion-cooled HEB is a good transparency of the interface between the heat sinks and the material of the bolometer bridge. A thermal resistance results in a slower out-diffusion of the hot electrons and thus increases the effective bridge length and thermal response time. Defining the bolometer bridge by lift-off with subsequent deposition of the heat sinks (Fig. 1) [2] has the major disadvantage of high requirements for the overlap accuracy of the Electron-Beam-Lithography (EBL) system to position the heat sinks on the contact areas of the bridge. A solution is offered by the self-aligned process (Fig. 2). Here, the substrate is covered with a blanket layer of Nb. The heat sinks and a metal strip of the width of the bolometer bridge are deposited in succession. The bridge is now etched out of the blanket layer by using reactive ion etching (RIE) where the heat sinks and the metal strip serve as etch masks: the spacing between the heat sinks determines the bridge length while the metal strip defines the width. The overlap between Nb and Au heat sinks is large. Fig. 1: Outline of HEB fabrication by lift off (top view) a) Bolometer bridge defined by liftoff. b) Deposition of the heat sinks. The contact area (shaded) to the heat sinks is small. bolometer bridge
Diffusion-cooled aluminum hot-electron bolometer (HEB) mixers are of interest for low-noise high resolution THz-frequency spectroscopy within astrophysics. Al HEB mixers offer operation with an order of magnitude less local oscillator power, higher intermediate frequency bandwidth and potentially lower noise than competing devices made from other materials. We report on mixer experiments at 618 GHz with devices fabricated from films with sheet resistances in the range from about 55 /spl Omega/ down to about 9 /spl Omega/ per square. Intermediate frequency bandwidths of up to 3 GHz were measured (1 /spl mu/m long device), with absorbed local oscillator power levels of 0.5 to 6 nW and mixer conversion up to -21.5 dB. High input coupling efficiency implies that the electrons in the device are able to thermalize before escaping from the device. It was found that the long coherence length complicates mixer operations due to the proximity of the contact pads. Also, saturation at the IF frequency may be a concern for this type of device, and warrants further studies.
We describe superconducting diffusion-cooled hot-electron bolometers that were fabricated fromtantalum films grown on a thin niobium seed layer. The seed layer promotes single-phase growth of the Ta films, resulting in high-quality bolometers with transition temperatures up to 2.35 K and transition widths of less than 0.2 K. An S-parameter measurement set-up in a He-3 cryostat was used to measure device impedance versus frequency of a 400 nm long device at a temperature of 400 mK. It is shown that a 3 dB roll-off frequency of about 1 GHz can be achieved when the device resistance matches the impedance of the embedding network (no electrothermal feedback). This would lead to a prediction of 16 GHz for a 100 nm device, and indicates that a heterodyne mixer using a Ta HEB should be able to operate at several GHz even with a significant amount of electrothermal feedback.
Superconducting Hot-electron Bolometric (HE.B) mixers employing thin films ofNbN have become the devices of choice for heterodyne detection at tera,hertz frequen- cies. HEB mixers are inherently insensitive to the bandgap frequency of the superconducting material used in the device, in contrast to SIS mixers,. We have developed a fabrication pro- cess for thin NbN films at the National Institute of Standards and Technology in Boulder, CO. A two-fold approach can be taken. The first is to maximize the critical temperature of the superconducting device by growing thicker films at the expense of IF bandwidth, whereas the second approach focuses on maximizing the IF bandwidth at the expense of the critical tem- perature. So far, we have developed a film-deposition process utilizing our DC reactive mag- netron sputtering chamber. By current-biasing the RF plasma in a mixture of Ar and N2, while using a Nb target, we can control the film stoichiometry and produce films with thicknesses of 5 nm. The films are deposited on MgO substrates that are heated to about 800 °C during depo- sition. A typical critical temperature (TO is about 10 K and the transition width is very small (0.5 K). The films are evaluated by measuring their superconducting characteristics as well as their thickness and surface roughness by means of AFM analysis. Phonon-cooled HEB devices are fabricated from the films to study their performance as HEB mixers. The device fabrication process at UMass/Amherst involves lift-off lithography of the antenna (gold), and Reactive ion etching (R1E) or wet etching of the NbN. The I-V char- acteristics and noise temperatures of the devices were measured in order to determine their quality for PHEB applications.
Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range 1.1-2.5 THz. The mixer device is a 0.15-03 /spl mu/m microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be /spl les/3000 K at 2.5 THz and the mixer IF bandwidth is /spl ap/9-10 GHz for a 0.1 /spl mu/m long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20-100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated The HEB mixer Is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// (YBCO) HEB are also discussed. The expected LO power of 1-10 /spl mu/W and SSB noise temperature of /spl ap/2000 K may make this mixer attractive for various remote sensing applications.