Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0505044 · Physical Review Letters

Continuous Quantum Measurement with Independent Detector Cross Correlations

Andrew N. Jordan, Μ. Büttiker

Published Nov 21, 2005• 70 citations
arXivHTMLPDF

Abstract

We investigate the advantages of using two independent, linear detectors for continuous quantum measurement. For single-shot measurement, the detection process may be quantum limited if the detectors are twins. For weak continuous measurement, cross correlations allow a violation of the Korotkov-Averin bound for the detector's signal-to-noise ratio. The joint weak measurement of noncommuting observables is also investigated, and we find the cross correlation changes sign as a function of frequency, reflecting a crossover from incoherent relaxation to coherent, out of phase oscillations. Our results are applied to a double quantum-dot charge qubit, simultaneously measured by two quantum point contacts.

DOI
10.1103/physrevlett.95.220401

Related papers

Qubit detection with a T-shaped double quantum dot detector

JunYan Luo, HuJun Jiao, Jing Hu +3 more

We propose to continuously monitor a charge qubit by utilizing a T-shaped double quantum dot detector, in which the qubit and double dot are arranged in such a unique way that the detector turns out to be particularly susceptible to the charge states of the qubit. Special attention is paid to the regime where acquisition of qubit information and backaction upon the measured system exhibit nontrivial correlation. The intrinsic dynamics of the qubit gives rise to dynamical blockade of tunneling events through the detector, resulting in a super-Poissonian noise. However, such a pronounced enhancement of the detector's shot noise does not necessarily produce a rising dephasing rate. In contrast, an inhibition of dephasing is entailed by the reduction of information acquisition in the dynamically blockaded regimes. We further reveal the important impact of the charge fluctuations on the measurement characteristics. Noticeably, under the condition of symmetric junction capacitances the noise pedestal of the circuit current is completely suppressed, leading to a divergent signal-to-noise ratio, and eventually to a violation of the Korotkov-Averin bound in quantum measurement. Our study offers the possibility for a double dot detector to reach the quantum limited effectiveness in a transparent manner.

arXiv:1501.00570•Physical Review B•Jul 7, 2015•5 citations

Weak measurement of qubit oscillations with strong response detectors: Violation of the fundamental bound imposed on linear detectors

HuJun Jiao, Feng Li, Shi-Kuan Wang +1 more

Qubit measurement by mesoscopic charge detectors has received great interest in the community of mesoscopic transport and solid-state quantum computation, and some controversial issues still remain unresolved. In this work, we revisit the continuous weak measurement of a solid-state qubit by single electron transistors (SETs) in nonlinear-response regime. For two SET models typically used in the literature, we find that the signal-to-noise ratio can violate the universal upper bound ``4,'' which is imposed quantum mechanically on linear-response detectors. This different result can be understood by means of the cross correlation of the detector currents by viewing the two junctions of the single SET as two detectors. Possible limitation of the potential-scattering approach to this result is also discussed.

arXiv:0806.2502•Physical Review B•Feb 24, 2009•9 citations

Continuous weak measurement of quantum coherent oscillations

Alexander N. Korotkov, D. V. Averin

We consider the problem of continuous quantum measurement of coherent oscillations between two quantum states of an individual two-state system. It is shown that the interplay between the information acquisition and the backaction dephasing of the oscillations by the detector imposes a fundamental limit, equal to four, on the signal-to-noise ratio of the measurement. The limit is universal, e.g., independent of the coupling strength between the detector and system, and results from the tendency of quantum measurement to localize the system in one of the measured eigenstates.

arXiv:cond-mat/0002203•Physical review. B, Condensed matter•Oct 5, 2001•210 citations

Continuous Weak Measurement of Qubit Oscillations with Strongly Responding Single Electron Transistors

HuJun Jiao, Shi-Kuan Wang, Feng Li +1 more

We investigate the continuous weak measurement of a solid-state qubit by single electron transistors in nonlinear response regime. It is found that the signal-to-noise ratio can violate the universal upper bound imposed quantum mechanically to any linear response detectors. We understand the violation by means of the cross-correlation of the detector currents.

•Jun 16, 2008•0 citations

Manipulation of double-dot spin qubit by continuous noisy measurement

Rusko Ruskov, V. V. Dobrovitski, Bruce N. Harmon

We consider evolution of a double quantum dot (DQD) two-electron spin qubit which is continuously weakly measured with a linear charge detector (quantum point contact). Since the interaction between the spins of two electrons depends on their charge state, the charge measurement affects the state of two spins, and induces non-trivial spin dynamics. We consider the regimes of strong and weak coupling to the detector, and investigate the measurement-induced spin dynamics both analytically and numerically. We observe emergence of the negative-result evolution and the system stabilization due to an analog of quantum Zeno effect. Moreover, unitary evolution between the triplet and a singlet state is induced by the negative-result measurement. We demonstrate that these effects exist for both strong and weak coupling between the detector and the DQD system.

arXiv:0906.0425•Jun 2, 2009•2 citations

Direct access to quantum fluctuations through cross-correlation measurements

Iurii Chernii, Eugene V. Sukhorukov

Detection of the quantum fluctuations by conventional methods meets certain obstacles, since it requires high-frequency measurements. Moreover, quantum fluctuations are normally dominated by classical noise and are usually further obstructed by various accompanying effects such as a detector backaction. In the present work, we demonstrate that these difficulties can be bypassed by performing the cross-correlation measurements. We propose to use a pair of two-level detectors, weakly coupled to a collective mode of an electric circuit. Fluctuations of the current source accumulated in the collective mode induce stochastic transitions in the detectors. These transitions are then read off by quantum-point contact (QPC) electrometers and translated into two telegraph processes in the QPC currents. Since both detectors interact with the same collective mode, this leads to a certain fraction of the correlated transitions. These correlated transitions are fingerprinted in the cross correlations of the telegraph processes, which can be detected at zero frequency, i.e., with long-time measurements. Concerning the dependance of the cross correlator on the detectors' energy splittings ${\ensuremath{\varepsilon}}_{1}$ and ${\ensuremath{\varepsilon}}_{2}$, the most interesting region is at the degeneracy points ${\ensuremath{\varepsilon}}_{1}=\ifmmode\pm\else\textpm\fi{}{\ensuremath{\varepsilon}}_{2}$, where it exhibits a sharp nonlocal resonance, that stems from higher-order processes. We find that at certain conditions, the main contribution to this resonance comes from the quantum noise. Namely, while the resonance line shape is weakly broadened by the classical noise, the height of the peak is directly proportional to the square of the quantum component of the noise spectral function.

arXiv:1112.2693•Physical Review B•May 22, 2012•2 citations
We investigate the advantages of using two independent, linear detectors for continuous quantum measurement. For single-shot measurement, the detection process may be quantum limited if the detectors are twins. For weak continuous measurement, cross correlations allow a violation of the Korotkov-Averin bound for the detector's signal-to-noise ratio. The joint weak measurement of noncommuting observables is also investigated, and we find the cross correlation changes sign as a function of frequency, reflecting a crossover from incoherent relaxation to coherent, out of phase oscillations. Our results are applied to a double quantum-dot charge qubit, simultaneously measured by two quantum point contacts.
We propose to continuously monitor a charge qubit by utilizing a T-shaped double quantum dot detector, in which the qubit and double dot are arranged in such a unique way that the detector turns out to be particularly susceptible to the charge states of the qubit. Special attention is paid to the regime where acquisition of qubit information and backaction upon the measured system exhibit nontrivial correlation. The intrinsic dynamics of the qubit gives rise to dynamical blockade of tunneling events through the detector, resulting in a super-Poissonian noise. However, such a pronounced enhancement of the detector's shot noise does not necessarily produce a rising dephasing rate. In contrast, an inhibition of dephasing is entailed by the reduction of information acquisition in the dynamically blockaded regimes. We further reveal the important impact of the charge fluctuations on the measurement characteristics. Noticeably, under the condition of symmetric junction capacitances the noise pedestal of the circuit current is completely suppressed, leading to a divergent signal-to-noise ratio, and eventually to a violation of the Korotkov-Averin bound in quantum measurement. Our study offers the possibility for a double dot detector to reach the quantum limited effectiveness in a transparent manner.
Qubit measurement by mesoscopic charge detectors has received great interest in the community of mesoscopic transport and solid-state quantum computation, and some controversial issues still remain unresolved. In this work, we revisit the continuous weak measurement of a solid-state qubit by single electron transistors (SETs) in nonlinear-response regime. For two SET models typically used in the literature, we find that the signal-to-noise ratio can violate the universal upper bound ``4,'' which is imposed quantum mechanically on linear-response detectors. This different result can be understood by means of the cross correlation of the detector currents by viewing the two junctions of the single SET as two detectors. Possible limitation of the potential-scattering approach to this result is also discussed.
We consider the problem of continuous quantum measurement of coherent oscillations between two quantum states of an individual two-state system. It is shown that the interplay between the information acquisition and the backaction dephasing of the oscillations by the detector imposes a fundamental limit, equal to four, on the signal-to-noise ratio of the measurement. The limit is universal, e.g., independent of the coupling strength between the detector and system, and results from the tendency of quantum measurement to localize the system in one of the measured eigenstates.
We consider evolution of a double quantum dot (DQD) two-electron spin qubit which is continuously weakly measured with a linear charge detector (quantum point contact). Since the interaction between the spins of two electrons depends on their charge state, the charge measurement affects the state of two spins, and induces non-trivial spin dynamics. We consider the regimes of strong and weak coupling to the detector, and investigate the measurement-induced spin dynamics both analytically and numerically. We observe emergence of the negative-result evolution and the system stabilization due to an analog of quantum Zeno effect. Moreover, unitary evolution between the triplet and a singlet state is induced by the negative-result measurement. We demonstrate that these effects exist for both strong and weak coupling between the detector and the DQD system.
Detection of the quantum fluctuations by conventional methods meets certain obstacles, since it requires high-frequency measurements. Moreover, quantum fluctuations are normally dominated by classical noise and are usually further obstructed by various accompanying effects such as a detector backaction. In the present work, we demonstrate that these difficulties can be bypassed by performing the cross-correlation measurements. We propose to use a pair of two-level detectors, weakly coupled to a collective mode of an electric circuit. Fluctuations of the current source accumulated in the collective mode induce stochastic transitions in the detectors. These transitions are then read off by quantum-point contact (QPC) electrometers and translated into two telegraph processes in the QPC currents. Since both detectors interact with the same collective mode, this leads to a certain fraction of the correlated transitions. These correlated transitions are fingerprinted in the cross correlations of the telegraph processes, which can be detected at zero frequency, i.e., with long-time measurements. Concerning the dependance of the cross correlator on the detectors' energy splittings ${\ensuremath{\varepsilon}}_{1}$ and ${\ensuremath{\varepsilon}}_{2}$, the most interesting region is at the degeneracy points ${\ensuremath{\varepsilon}}_{1}=\ifmmode\pm\else\textpm\fi{}{\ensuremath{\varepsilon}}_{2}$, where it exhibits a sharp nonlocal resonance, that stems from higher-order processes. We find that at certain conditions, the main contribution to this resonance comes from the quantum noise. Namely, while the resonance line shape is weakly broadened by the classical noise, the height of the peak is directly proportional to the square of the quantum component of the noise spectral function.