arXiv:cond-mat/0405024 · Physical Review B

Detection of a persistent-current qubit by resonant activation

Patrice Bertet, I. Chiorescu, Kouichi Semba, C. J. P. M. Harmans, Johan E. Mooij

Published Sep 20, 2004• 23 citations
arXivHTMLPDF

Abstract

We present the implementation of a scheme to detect the quantum state of a persistent-current qubit. It relies on the dependency of the measuring superconducting quantum interference device plasma frequency on the qubit state, which we detect by resonant activation. With a measurement pulse of only $5\phantom{\rule{0.3em}{0ex}}\mathrm{ns}$, we observed Rabi oscillations with high visibility (65%).

DOI
10.1103/physrevb.70.100501

Related papers

Method for direct observation of coherent quantum oscillations in a superconducting phase qubit

Ya. S. Greenberg, A. Izmalkov, M. Grajcar +3 more

Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop induce the voltage oscillations across the coil of a high quality resonant tank circuit, inductively coupled to the phase qubit. It is the presence of these voltage oscillations in the detected signal which reveals the existence of Rabi oscillations in the qubit. A detailed calculation for zero and nonzero temperatures are made for the case of persistent current qubit. According to the estimates for decoherence and relaxation times, the effect can be detected using conventional rf circuitry, with Rabi frequency in the MHz range.

arXiv:cond-mat/0208143•Physical review. B, Condensed matter•Dec 31, 2002•24 citations

Resonant readout of a superconducting persistent current qubit

Janice C. Lee

Superconducting Josephson junction devices rank among the best candidates for realizing a quantum computer. While the coherent control of quantum dynamics has been demonstrated in these solid-state, macroscopic quantum systems, a major challenge has been to increase the coherence times for these qubits. With an objective to reduce the level of readout-induced decoherence, this thesis work focuses on a resonant readout scheme developed for a niobium persistent-current (PC) qubit. This non-dissipative readout approach detects the flux state of the qubit by sensing a change in the Josephson inductance of a SQUID magnetometer. By incorporating the SQUID inductor in a high-Q resonant circuit, we distinguished the flux states of the qubit as a shift in the resonant frequency at 300 mK. The nonlinearity due to the Josephson inductance has characteristic effects on the resonant behavior of the readout circuit. We observed novel manifestation of this nonlinearity given the high quality factor of the resonance. The readout circuit was characterized in the linear as well as the nonlinear regime for its potential use as a bifurcation amplifier. Numerical simulations based on Josephson-junction circuits were also performed to understand the observed nonlinearity in the resonant behavior.

•Jan 1, 2006•0 citations

Coherent Quantum Dynamics of a Superconducting Flux Qubit

I. Chiorescu, Yasunobu Nakamura, C. J. P. M. Harmans +1 more

We have observed coherent time evolution between two quantum states of a superconducting flux qubit comprising three Josephson junctions in a loop. The superposition of the two states carrying opposite macroscopic persistent currents is manipulated by resonant microwave pulses. Readout by means of switching-event measurement with an attached superconducting quantum interference device revealed quantum-state oscillations with high fidelity. Under strong microwave driving, it was possible to induce hundreds of coherent oscillations. Pulsed operations on this first sample yielded a relaxation time of 900 nanoseconds and a free-induction dephasing time of 20 nanoseconds. These results are promising for future solid-state quantum computing.

arXiv:cond-mat/0305461•Science•Mar 20, 2003•1,220 citations

Method for direct observation of coherent quantum oscillations in a superconducting phase qubit: Computer simulations

Ya. S. Greenberg

Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in the GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop are detected by a high-quality resonant tank circuit, inductively coupled to the phase qubit. Here we present the results of detailed computer simulations of the interaction of a classical object (resonant tank circuit) with a quantum object (phase qubit), which explicitly account for the back action of a tank circuit. According to the results of our simulations the Rabi oscillations in the MHz range can be detected using the conventional NMR pulse Fourier technique.

arXiv:cond-mat/0303049•Physical review. B, Condensed matter•Dec 30, 2003•7 citations

Qubit state detection using the quantum Duffing oscillator

Vicente Leyton‐Ortega, Michael Thorwart, Vittorio Peano

We introduce a detection scheme for the state of a qubit that is based on resonant few-photon transitions in a driven nonlinear resonator. The latter is parametrically coupled to the qubit and is used as its detector. Close to the fundamental resonator frequency, the nonlinear resonator shows sharp resonant few-photon transitions. Depending on the qubit state, these few-photon resonances are shifted to different driving frequencies. We show that this detection scheme offers the advantage of small back action, a large discrimination power with an enhanced readout fidelity, and a sufficiently large measurement efficiency. A realization of this scheme in the form of a persistent current qubit inductively coupled to a driven SQUID detector in its nonlinear regime is discussed.

arXiv:1109.5562•Physical Review B•Oct 3, 2011•7 citations

Dispersive readout of a flux qubit at the single-photon level

Jedediah E Johnson, Emile Hoskinson, Chris Macklin +3 more

A superconducting flux qubit is inductively coupled to a superconducting quantum interference device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed with a microwave signal and detected with a microstrip SQUID amplifier. At a mean resonator occupation $\overline{n}=1.5$ photons, the readout visibility is increased by a factor of 4.5 over that using a cryogenic semiconductor amplifier. As $\overline{n}$ is increased from 0.008 to 0.1, no reduction in ${T}_{1}$ is observed, potentially enabling continuous monitoring of the qubit state.

arXiv:1109.2858•Physical Review B•Dec 15, 2011•20 citations
We present the implementation of a scheme to detect the quantum state of a persistent-current qubit. It relies on the dependency of the measuring superconducting quantum interference device plasma frequency on the qubit state, which we detect by resonant activation. With a measurement pulse of only 5ns5\phantom{\rule{0.3em}{0ex}}\mathrm{ns}5ns, we observed Rabi oscillations with high visibility (65%).
Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop induce the voltage oscillations across the coil of a high quality resonant tank circuit, inductively coupled to the phase qubit. It is the presence of these voltage oscillations in the detected signal which reveals the existence of Rabi oscillations in the qubit. A detailed calculation for zero and nonzero temperatures are made for the case of persistent current qubit. According to the estimates for decoherence and relaxation times, the effect can be detected using conventional rf circuitry, with Rabi frequency in the MHz range.
Superconducting Josephson junction devices rank among the best candidates for realizing a quantum computer. While the coherent control of quantum dynamics has been demonstrated in these solid-state, macroscopic quantum systems, a major challenge has been to increase the coherence times for these qubits. With an objective to reduce the level of readout-induced decoherence, this thesis work focuses on a resonant readout scheme developed for a niobium persistent-current (PC) qubit. This non-dissipative readout approach detects the flux state of the qubit by sensing a change in the Josephson inductance of a SQUID magnetometer. By incorporating the SQUID inductor in a high-Q resonant circuit, we distinguished the flux states of the qubit as a shift in the resonant frequency at 300 mK. The nonlinearity due to the Josephson inductance has characteristic effects on the resonant behavior of the readout circuit. We observed novel manifestation of this nonlinearity given the high quality factor of the resonance. The readout circuit was characterized in the linear as well as the nonlinear regime for its potential use as a bifurcation amplifier. Numerical simulations based on Josephson-junction circuits were also performed to understand the observed nonlinearity in the resonant behavior.
We have observed coherent time evolution between two quantum states of a superconducting flux qubit comprising three Josephson junctions in a loop. The superposition of the two states carrying opposite macroscopic persistent currents is manipulated by resonant microwave pulses. Readout by means of switching-event measurement with an attached superconducting quantum interference device revealed quantum-state oscillations with high fidelity. Under strong microwave driving, it was possible to induce hundreds of coherent oscillations. Pulsed operations on this first sample yielded a relaxation time of 900 nanoseconds and a free-induction dephasing time of 20 nanoseconds. These results are promising for future solid-state quantum computing.
Time-domain observations of coherent oscillations between quantum states in mesoscopic superconducting systems have so far been restricted to restoring the time-dependent probability distribution from the readout statistics. We propose a method for direct observation of Rabi oscillations in a phase qubit. The external source, typically in the GHz range, induces transitions between the qubit levels. The resulting Rabi oscillations of supercurrent in the qubit loop are detected by a high-quality resonant tank circuit, inductively coupled to the phase qubit. Here we present the results of detailed computer simulations of the interaction of a classical object (resonant tank circuit) with a quantum object (phase qubit), which explicitly account for the back action of a tank circuit. According to the results of our simulations the Rabi oscillations in the MHz range can be detected using the conventional NMR pulse Fourier technique.
We introduce a detection scheme for the state of a qubit that is based on resonant few-photon transitions in a driven nonlinear resonator. The latter is parametrically coupled to the qubit and is used as its detector. Close to the fundamental resonator frequency, the nonlinear resonator shows sharp resonant few-photon transitions. Depending on the qubit state, these few-photon resonances are shifted to different driving frequencies. We show that this detection scheme offers the advantage of small back action, a large discrimination power with an enhanced readout fidelity, and a sufficiently large measurement efficiency. A realization of this scheme in the form of a persistent current qubit inductively coupled to a driven SQUID detector in its nonlinear regime is discussed.
A superconducting flux qubit is inductively coupled to a superconducting quantum interference device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed with a microwave signal and detected with a microstrip SQUID amplifier. At a mean resonator occupation n‾=1.5\overline{n}=1.5n=1.5 photons, the readout visibility is increased by a factor of 4.5 over that using a cryogenic semiconductor amplifier. As n‾\overline{n}n is increased from 0.008 to 0.1, no reduction in T1{T}_{1}T1​ is observed, potentially enabling continuous monitoring of the qubit state.