Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0203340 · Physical Review Letters

Efficiency of Mesoscopic Detectors

S. Pilgram, Μ. Büttiker

Published Oct 24, 2002• 121 citations
arXivHTMLPDF

Abstract

We consider a mesoscopic measuring device whose conductance is sensitive to the state of a two-level system. The detector is described with the help of its scattering matrix. Its elements can be used to calculate the relaxation and decoherence times of the system, and determine the characteristic time for a reliable measurement. We derive conditions needed for an efficient ratio of decoherence and measurement times. To illustrate the theory we discuss the distribution function of the efficiency of an ensemble of open chaotic cavities.

DOI
10.1103/physrevlett.89.200401

Related papers

Controlled Dephasing and Measurement Efficiency via Quantum Dot Detector

Gyong Luck Khym, Youngnae Lee, Kicheon Kang

We study charge detection and controlled dephasing of a mesoscopic system via a quantum dot detector (QDD), where the mesoscopic system and the QDD are capacitively coupled. The QDD is considered to have coherent resonant tunnelling via a single level. It is found that the dephasing rate is proportional to the square of the conductance of the QDD for the Breit-Wigner model, showing that the dephasing is completely different from the shot noise of the detector. The measurement rate, on the other hand, shows a dip near the resonance. Our findings are peculiar especially for a symmetric detector in the following aspect: The dephasing rate is maximum at resonance of the QDD where the detector conductance is insensitive to the charge state of the mesoscopic system. As a result, the efficiency of the detector shows a dip and vanishes at resonance, in contrast to the single-channel symmetric non-resonant detector that has always a maximum efficiency. We find that this difference originates from a very general property of the scattering matrix: The abrupt phase change exists in the scattering amplitudes in the presence of the symmetry, which is insensitive to the detector current but {\em stores} the information of the quantum state of the mesoscopic system.

arXiv:cond-mat/0601535•Journal of the Physical Society of Japan•Jun 8, 2006•10 citations

Quantum-limited measurement and information in mesoscopic detectors

Aashish A. Clerk, S. M. Girvin, A. Douglas Stone

We formulate general conditions necessary for a linear-response detector to reach the quantum limit of measurement efficiency, where the measurement-induced dephasing rate takes its minimum possible value. These conditions are applicable to both noninteracting and interacting systems. We assess the status of these requirements in an arbitrary noninteracting scattering-based detector, identifying the symmetries of the scattering matrix needed to reach the quantum limit. We show that these conditions are necessary to prevent the existence of information in the detector that is not extracted in the measurement process.

arXiv:cond-mat/0211001•Physical review. B, Condensed matter•Apr 28, 2003•131 citations

Transporte quântico decoerente em sistemas mesoscópicos

Elenilda Josefa de Oliveira

The scientific advances we have experienced in recent decades have enabled us to produce systems in the mesoscopic scale. These systems have become very useful as research tools in various areas of science. In mesoscopic physics the ondulatory characteristic of electrons is more evident than in classical physics and the electron conduction process is better represented by the wave function that describes it. Examples of application of mesoscopic systems are quantum dots which are open cavities where electrons are limited to flow through. Thus, the objective of this work is to study the effects of decoherence in the transport of electrons in two systems: i) quantum dot with a fictitious guide and ii) quantum dot with stub, where we take into account ondulatory properties of electrons. The formalism that we use is the scattering matrix, which relates the incoming and outgoing amplitudes in the scattering of waves coming in and out of the scattering region. Since the studied systems are chaotic, the scattering matrices can be treated as random. These matrices were generated by computational simulation and then the conductance values were computed. The conductance distribution was obtained by means of probabilistic analysis.

•Jul 30, 2015•0 citations

Interaction-Free Measurement in mesoscopic systems and the reduction postulate

S. A. Gurvitz

We show that a noninvasive,``negative-result measurement'' can be realized in quantum dot systems. The measurement process is studied by applying the Schrödinger equation to the whole system (including the detector). We demonstrate that the possibility of observing a particular state out of coherent superposition leads to collapse of the corresponding nondiagonal density-matrix elements of the measured system. No additional reduction postulate is needed. Experimental consequences of the collapse time and the relativistic requirement are discussed for mesoscopic and optical systems.

arXiv:quant-ph/9607029•Jul 31, 1996•13 citations

Decoherence of mesoscopic states of cavity fields

K. M. Fonseca-Romero, Maria Carolina Nemes, J. G. Peixoto de Faria +2 more

We show that two-atom correlation measurements of the type involved in a recent experimental study of the evolution of a mesoscopic superposition state prepared in a definite mode of a high-$Q$ cavity can be used to determine the eigenvalues of the reduced density matrix of the field, provided the assumed dynamical conditions are actually fulfilled to experimental accuracy. These conditions involve (i) a purely dispersive coupling of the field to the Rydberg atoms used to manipulate and to monitor the cavity field, and (ii) the effective absence of correlations in the ground state of the system consisting of the cavity coupled to the ``reservoir'' which accounts for the decoherence and damping processes. A microscopic calculation at zero temperature is performed and compared to master equation results.

arXiv:quant-ph/9804033•Physical Review A•Oct 1, 1998•17 citations

Quantum Measurement and Stochastic Processes in Mesoscopic Conductors

Gerard J Milburn

In quantum measurement theory it is necessary to show how a quantum source conditions a classical stochastic record of measured results. We discuss mesoscopic conductance using quantum stochastic calculus to elucidate the quantum nature of the measurement taking place in these systems. To illustrate the method we derive the current fluctuations in a two terminal mesoscopic circuit with two tunnel barriers containing a single quasi bound state on the well. The method enables us to focus on either the incoming/ outgoing Fermi fields in the leads, or on the irreversible dynamics of the well state itself. We show an equivalence between the approach of BÜttiker and the Fermi quantum stochastic calculus for mesoscopic systems.

Australian Journal of Physics•Feb 23, 2001•9 citations
We consider a mesoscopic measuring device whose conductance is sensitive to the state of a two-level system. The detector is described with the help of its scattering matrix. Its elements can be used to calculate the relaxation and decoherence times of the system, and determine the characteristic time for a reliable measurement. We derive conditions needed for an efficient ratio of decoherence and measurement times. To illustrate the theory we discuss the distribution function of the efficiency of an ensemble of open chaotic cavities.
We study charge detection and controlled dephasing of a mesoscopic system via a quantum dot detector (QDD), where the mesoscopic system and the QDD are capacitively coupled. The QDD is considered to have coherent resonant tunnelling via a single level. It is found that the dephasing rate is proportional to the square of the conductance of the QDD for the Breit-Wigner model, showing that the dephasing is completely different from the shot noise of the detector. The measurement rate, on the other hand, shows a dip near the resonance. Our findings are peculiar especially for a symmetric detector in the following aspect: The dephasing rate is maximum at resonance of the QDD where the detector conductance is insensitive to the charge state of the mesoscopic system. As a result, the efficiency of the detector shows a dip and vanishes at resonance, in contrast to the single-channel symmetric non-resonant detector that has always a maximum efficiency. We find that this difference originates from a very general property of the scattering matrix: The abrupt phase change exists in the scattering amplitudes in the presence of the symmetry, which is insensitive to the detector current but {\em stores} the information of the quantum state of the mesoscopic system.
We formulate general conditions necessary for a linear-response detector to reach the quantum limit of measurement efficiency, where the measurement-induced dephasing rate takes its minimum possible value. These conditions are applicable to both noninteracting and interacting systems. We assess the status of these requirements in an arbitrary noninteracting scattering-based detector, identifying the symmetries of the scattering matrix needed to reach the quantum limit. We show that these conditions are necessary to prevent the existence of information in the detector that is not extracted in the measurement process.
The scientific advances we have experienced in recent decades have enabled us to produce systems in the mesoscopic scale. These systems have become very useful as research tools in various areas of science. In mesoscopic physics the ondulatory characteristic of electrons is more evident than in classical physics and the electron conduction process is better represented by the wave function that describes it. Examples of application of mesoscopic systems are quantum dots which are open cavities where electrons are limited to flow through. Thus, the objective of this work is to study the effects of decoherence in the transport of electrons in two systems: i) quantum dot with a fictitious guide and ii) quantum dot with stub, where we take into account ondulatory properties of electrons. The formalism that we use is the scattering matrix, which relates the incoming and outgoing amplitudes in the scattering of waves coming in and out of the scattering region. Since the studied systems are chaotic, the scattering matrices can be treated as random. These matrices were generated by computational simulation and then the conductance values were computed. The conductance distribution was obtained by means of probabilistic analysis.
We show that a noninvasive,``negative-result measurement'' can be realized in quantum dot systems. The measurement process is studied by applying the Schrödinger equation to the whole system (including the detector). We demonstrate that the possibility of observing a particular state out of coherent superposition leads to collapse of the corresponding nondiagonal density-matrix elements of the measured system. No additional reduction postulate is needed. Experimental consequences of the collapse time and the relativistic requirement are discussed for mesoscopic and optical systems.
We show that two-atom correlation measurements of the type involved in a recent experimental study of the evolution of a mesoscopic superposition state prepared in a definite mode of a high-QQQ cavity can be used to determine the eigenvalues of the reduced density matrix of the field, provided the assumed dynamical conditions are actually fulfilled to experimental accuracy. These conditions involve (i) a purely dispersive coupling of the field to the Rydberg atoms used to manipulate and to monitor the cavity field, and (ii) the effective absence of correlations in the ground state of the system consisting of the cavity coupled to the ``reservoir'' which accounts for the decoherence and damping processes. A microscopic calculation at zero temperature is performed and compared to master equation results.
In quantum measurement theory it is necessary to show how a quantum source conditions a classical stochastic record of measured results. We discuss mesoscopic conductance using quantum stochastic calculus to elucidate the quantum nature of the measurement taking place in these systems. To illustrate the method we derive the current fluctuations in a two terminal mesoscopic circuit with two tunnel barriers containing a single quasi bound state on the well. The method enables us to focus on either the incoming/ outgoing Fermi fields in the leads, or on the irreversible dynamics of the well state itself. We show an equivalence between the approach of BÜttiker and the Fermi quantum stochastic calculus for mesoscopic systems.