Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Attenuated total reflection spectroscopy on alkali-metal atoms

賢 東條

Published Sep 24, 2003• 0 citations
OpenAlex

Related papers

Attenuated total reflection spectroscopy on alkali-metal atoms

賢 東條

•Jan 1, 2003•0 citations

Glory interference spectroscopy in alkali-metal atoms: Atom-dependent effects

K. Ferentinou, E. Tzalla, S. Danakas +2 more

APS Open Science•Nov 10, 2026•0 citations

Analytical theory of dual-freqency sub-Doppler spectroscopy of alkali metal atoms

Mikhailov, A, Denis V. Brazhnikov, Rodolphe Boudot

•Aug 22, 2021•0 citations

Quantum infrared attenuated total reflection spectroscopy

Torataro Kurita, Yu Mukai, Ryo Okamoto +5 more

Quantum infrared spectroscopy (QIRS), which harnesses the quantum interference between entangled visible and infrared photon-pair-generation processes in a nonlinear quantum interferometer, has attracted considerable attention for realizing infrared spectroscopy with high-performance visible detectors and light sources. However, a shortcoming of QIRS is its vulnerability to wave-front distortion caused by the sample structure, which can degrade the quantum interference. To address this problem, we propose employing the attenuated total-reflection (ATR) method, which utilizes close contact between the sample and a prism. The ATR method is one of the most utilized methods in infrared spectroscopy since it can be used to measure various types of materials, such as liquid, film, and powder samples, and is therefore useful for real-world applications. Here, we report wavelength-tunable ATR-QIRS measurements. We constructed a Michelson-type nonlinear quantum interferometer with a ${\mathrm{Ca}\mathrm{F}}_{2}$ prism, and measured the absorption of water OH-stretching (approximately $3\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\mathrm{m}$). The transmission spectrum obtained by our ATR-QIRS system shows good agreement with a numerically calculated transmission spectrum using the Fresnel equation.

Physical Review Applied•Jan 28, 2025•7 citations

Ramsey Spectroscopy of CPT Resonances on the D1 Line of Alkali Metal Atoms in Miniature Cells in the Field of Counterpropagating Waves with Opposite Circular Polarizations

Valeriy I. Yudin, M. Yu. Basalaev, Daba A. Radnatarov +4 more

In this study, the Ramsey spectroscopy of coherent population trapping resonances excited on the D1 line of alkali metal atoms in miniature vapor cells has been studied theoretically and experimentally. The configuration of the field produced by two counterpropagating waves with opposite circular polarizations has been considered. A counterpropagating wave is formed as a result of reflection from a partially transmitting output mirror, while the signal from the initial wave transmitted through the mirror is detected. It is shown that such a scheme is characterized by the optimal mirror reflection coefficient, for which the short-term stability can be substantially improved relative to the standard scheme without the counterpropagating wave. The three-fold improvement of the short-term stability of the atomic clock based on the coherent population trapping resonance in a vapor cell with 87Rb atoms has been demonstrated experimentally.

Journal of Experimental and Theoretical Physics Letters•Oct 1, 2024•0 citations

The interaction of strong laser light with alkali-metal atoms

Janusz Czub, W. Miklaszewski

Zeitschrift für Physik D Atoms Molecules and Clusters•Mar 1, 1988•4 citations
Quantum infrared spectroscopy (QIRS), which harnesses the quantum interference between entangled visible and infrared photon-pair-generation processes in a nonlinear quantum interferometer, has attracted considerable attention for realizing infrared spectroscopy with high-performance visible detectors and light sources. However, a shortcoming of QIRS is its vulnerability to wave-front distortion caused by the sample structure, which can degrade the quantum interference. To address this problem, we propose employing the attenuated total-reflection (ATR) method, which utilizes close contact between the sample and a prism. The ATR method is one of the most utilized methods in infrared spectroscopy since it can be used to measure various types of materials, such as liquid, film, and powder samples, and is therefore useful for real-world applications. Here, we report wavelength-tunable ATR-QIRS measurements. We constructed a Michelson-type nonlinear quantum interferometer with a CaF2{\mathrm{Ca}\mathrm{F}}_{2}CaF2​ prism, and measured the absorption of water OH-stretching (approximately $3\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\mathrm{m}$). The transmission spectrum obtained by our ATR-QIRS system shows good agreement with a numerically calculated transmission spectrum using the Fresnel equation.
In this study, the Ramsey spectroscopy of coherent population trapping resonances excited on the D1 line of alkali metal atoms in miniature vapor cells has been studied theoretically and experimentally. The configuration of the field produced by two counterpropagating waves with opposite circular polarizations has been considered. A counterpropagating wave is formed as a result of reflection from a partially transmitting output mirror, while the signal from the initial wave transmitted through the mirror is detected. It is shown that such a scheme is characterized by the optimal mirror reflection coefficient, for which the short-term stability can be substantially improved relative to the standard scheme without the counterpropagating wave. The three-fold improvement of the short-term stability of the atomic clock based on the coherent population trapping resonance in a vapor cell with 87Rb atoms has been demonstrated experimentally.