Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Hot-electron superconducting detectors for high-background sub-mm wave applications

Boris S. Karasik, Andrei V. Sergeev

Published Jun 19, 2003• 0 citations
OpenAlex

Related papers

Submillimeter Wave Superconducting Hot-Electron Direct Detectors

Boris S. Karasik, Bertrand Delaet, William R. McGrath +3 more

•Jan 1, 2002•0 citations

Experimental study of SubMM wave superconducting hot-electron direct detectors

Boris S. Karasik, Bertrand Delaet, William R. McGrath +3 more

•Aug 4, 2002•0 citations

Superconducting mm-Wave Detector

Antti Hakola, Timo T. Kajava, M. Kiviranta +2 more

•Jan 1, 2001•0 citations

Development of superconducting mixers at sub-millimeter wavelengths

Sheng-Cai Shi

The MM and SubMM Lab of Purple Mountain Observatory has made major efforts in the development of high-sensitivity detectors for radio astronomy. The paper mainly introduces the development of a 500-GHz superconducting SIS (superconductor-insulator-superconductor) mixer and an 850-GHz HEB (hot-electron-bolometer) mixer.

URSI Asia-Pacific Radio Science Conference•Apr 25, 2005•0 citations

Fabrication of high-T/sub c/ hot-electron bolometric mixers for terahertz applications

Michael J. Burns, Alan W. Kleinsasser, K. A. Delin +4 more

Superconducting hot-electron bolometers (HEB) represent a promising candidate for heterodyne mixing at frequencies exceeding 1 THz. Nb HEB mixers offer performance competitive with tunnel junctions without the frequency limit imposed by the superconducting energy gap. Although the performance of YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// HEB mixers is not projected to be superior to that of Nb devices, which operate at low temperatures, they introduce the possibility of sensitive, low power heterodyne detectors operating at temperatures approaching 90 K for applications requiring portability and closed-cycle refrigeration. We report on the fabrication and characterization, both DC and RF, of high-T/sub c/ mixers based on ultra-thin (/spl les/20 nm) YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// films patterned to micrometer dimensions and incorporated into 2.5 THz planar mixer circuits.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•12 citations

Capacitively Coupled Hot-Electron Microbolometer as a Perspective IR and Sub-mm Wave Sensor

L. S. Kuzmin

normal metal strip at low temperatures (so called electron effect) to produce a large A novel concept of the normal-metal hotelectron bolometer using capacitive coupling of the absorber to antenna (NHEB-CC) has been proposed. The concept is based on the normal metal hot-electron microbolometer with Andreev mirrors (NHEB-A) using a SIN junction as a temperature sensor [1-3]. The NHEB-A technology brings a possibility to fabricate the sub-mm wave receiver for space applications with a noise equivalent power NEP about 3x1 0' 8 W/Hz at 100 mK. However, the Andreev mirrors could give certain frequency limitations for using this bolometer for higher frequencies with the energy quantum hf higher than the energy of a superconducting gap A. The NHEB-CC technology with capacitive coupling of the absorber to antenna avoids these problems. The effective high frequency coupling of the external signal in NHEB-CC is achieved by a low impedance of the coupling capacitances. At the same time, the capacitance gives reliable protection against escaping the hot electrons from the absorber. Usual tunnel junctions with proper thickness of the barrier can be used as capacitors. In such realization, we keep the main advantage of the NHEB technology very small thermal conductance between electrons and phonons due to small volume of an absorber (typical value of G is 2x10 W/K for T=100 mK) in combination with frequency independent protection of the absorber against thermal leak to the antenna.

•Mar 1, 1998•1 citation
Superconducting hot-electron bolometers (HEB) represent a promising candidate for heterodyne mixing at frequencies exceeding 1 THz. Nb HEB mixers offer performance competitive with tunnel junctions without the frequency limit imposed by the superconducting energy gap. Although the performance of YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// HEB mixers is not projected to be superior to that of Nb devices, which operate at low temperatures, they introduce the possibility of sensitive, low power heterodyne detectors operating at temperatures approaching 90 K for applications requiring portability and closed-cycle refrigeration. We report on the fabrication and characterization, both DC and RF, of high-T/sub c/ mixers based on ultra-thin (/spl les/20 nm) YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// films patterned to micrometer dimensions and incorporated into 2.5 THz planar mixer circuits.
normal metal strip at low temperatures (so called electron effect) to produce a large A novel concept of the normal-metal hotelectron bolometer using capacitive coupling of the absorber to antenna (NHEB-CC) has been proposed. The concept is based on the normal metal hot-electron microbolometer with Andreev mirrors (NHEB-A) using a SIN junction as a temperature sensor [1-3]. The NHEB-A technology brings a possibility to fabricate the sub-mm wave receiver for space applications with a noise equivalent power NEP about 3x1 0' 8 W/Hz at 100 mK. However, the Andreev mirrors could give certain frequency limitations for using this bolometer for higher frequencies with the energy quantum hf higher than the energy of a superconducting gap A. The NHEB-CC technology with capacitive coupling of the absorber to antenna avoids these problems. The effective high frequency coupling of the external signal in NHEB-CC is achieved by a low impedance of the coupling capacitances. At the same time, the capacitance gives reliable protection against escaping the hot electrons from the absorber. Usual tunnel junctions with proper thickness of the barrier can be used as capacitors. In such realization, we keep the main advantage of the NHEB technology very small thermal conductance between electrons and phonons due to small volume of an absorber (typical value of G is 2x10 W/K for T=100 mK) in combination with frequency independent protection of the absorber against thermal leak to the antenna.