Physical Review A

Quantum-calibrated vector magnetic-field imaging and magnetization reconstruction with a fiber-coupled diamond magnetometer

Jinxu Wang, Kunpeng Zhang, Heli Chen, Na Li, Yong Wang, Zijian Wang, Yang Wang, Zhiqiang Zhang, Wentao Lu, Guobin Chen, Yibao Wang, Fengxiang Guo, Shiheng Liang, Liangcai Xu, Xun Yang, Zhigang Gai, Guanxiang Du

Published Nov 12, 2026• 0 citations
Publisher
DOI
10.1103/dcz6-xgwk

Related papers

Optimized Diamond Development for Quantum Vector Magnetometry

John F. Barry, Xingyu Zhang, Linh Pham +3 more

IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)•Apr 1, 2019•0 citations

Micron-resolved quantum precision measurement of magnetic field at the Tesla level

Si-Han An, Shi-Yu Ge, Wentao Lu +10 more

Abstract We develop a quantum precision measurement method for magnetic field at the Tesla level by utilizing a fiber diamond magnetometer. Central to our system is a micron-sized fiber diamond probe positioned on the surface of a coplanar waveguide made of nonmagnetic materials. Calibrated with a nuclear magnetic resonance magnetometer, this probe demonstrates a broad magnetic field range from 10 mT to 1.5 T with a nonlinear error better than 0.0028% under a standard magnetic field generator and stability better than 0.0012% at a 1.5 T magnetic field. Finally, we demonstrate quantitative mapping of the vector magnetic field on the surface of a permanent magnet using the diamond magnetometer.

Chinese Physics B•Sep 24, 2024•5 citations

Sensitive endoscopic diamond magnetometer for non-contact sensing in confined environments

Johannes Wesseler, Roland Nagy

Transitioning quantum magnetometry from laboratory environments to real-world applications has been limited by a persistent trade-off between sensor miniaturization and magnetic sensitivity. While bulky systems can achieve high sensitivity, endoscopic probes commonly suffer from inefficient fluorescence collection and reduced performance. Here we resolve this trade-off and present a miniaturized diamond quantum magnetometer with a 6 mm diameter endoscopic sensor head, achieving a magnetic-field sensitivity of 91 pT/sqrt(Hz) with a 2 kHz measurement bandwidth in a magnetically unshielded environment. The fluorescence collection bottleneck is overcome by separating excitation and collection into different cores of a fused multi-core fiber bundle, coupled to the diamond through a custom high-numerical-aperture micro-objective. A compact FPGA-based backend performs microwave control, lock-in detection and real-time resonance tracking, enabling robust operation during magnetic-field imaging. To demonstrate the practical utility of the miniaturized sensor, we image the magnetic field of a commercial lithium-ion pouch cell during charge and discharge and reconstruct depth-integrated current-density maps of the current flow. These results show that endoscopic diamond magnetometers can combine high sensitivity with a probe geometry suitable for confined, unshielded measurements, opening new avenues in battery technology and beyond.

quant-pharXiv:2606.18871•Jun 18, 2026

High Sensitivity Fiber-Coupled Vector Magnetometry using NV Centers in a Femtosecond Laser-Written Diamond Waveguide

Demininggus Pekei, Giulio Coccia, Argyri Giakoumaki +4 more

Optics Express•Oct 29, 2026•0 citations

Scalar and Vector Airborne Platform Calibration Using Quantum and Classical Magnetometers and Inertial Sensors

Antonia Hager, Torleiv H. Bryne, Mia Jukić

Airborne magnetometry requires rigorous calibration to isolate geomagnetic signals from sensor errors and platform magnetic fields. This magnetic compensation is needed for applications like geophysical exploration and magnetic anomaly navigation. The standard approach utilizes a quantum scalar Optically Pumped Magnetometer (OPM) and a less sensitive fluxgate vector sensor for attitude information. This configuration typically results in a scalar approximation of the platform field. Advancements in high-sensitivity Diamond Nitrogen-Vacancy (NV) vector magnetometers now enable a re-evaluation of the standard hardware configuration and full vector calibration models. We show through rigorous theoretical analysis that scalar calibration models are robust to misalignment. Vector calibration models, however, are intrinsically first-order sensitive to attitude errors, irrespective of the accuracy of the magnetic field measurements. These errors arise from inaccurate representation of the background field direction in the body frame, and can amplify small orientation errors into noticeable calibration residuals. Using realistic sensor models and flight trajectories, we evaluate different sensor configurations for magnetic calibration and assess the use of onboard Inertial Navigation Systems (INS) as an independent attitude reference to enable stable compensation. Our results suggest that quantum vector magnetometers like NV sensors are not sufficient to solve the attitude bottleneck for airborne vector magnetic calibration. However, as a single sensor capable of providing both absolute field and directional measurements, they may offer benefits regarding sensor placement, synchronization, and scalar calibration accuracy.

quant-pharXiv:2605.04951•May 7, 2026

Simultaneous amplitude and phase wide-field imaging of AC magnetic signal using diamond quantum magnetometry

皓介 水野, Kosuke Mizuno, 整 石綿 +7 more

•Dec 1, 2019•0 citations
Abstract We develop a quantum precision measurement method for magnetic field at the Tesla level by utilizing a fiber diamond magnetometer. Central to our system is a micron-sized fiber diamond probe positioned on the surface of a coplanar waveguide made of nonmagnetic materials. Calibrated with a nuclear magnetic resonance magnetometer, this probe demonstrates a broad magnetic field range from 10 mT to 1.5 T with a nonlinear error better than 0.0028% under a standard magnetic field generator and stability better than 0.0012% at a 1.5 T magnetic field. Finally, we demonstrate quantitative mapping of the vector magnetic field on the surface of a permanent magnet using the diamond magnetometer.
Transitioning quantum magnetometry from laboratory environments to real-world applications has been limited by a persistent trade-off between sensor miniaturization and magnetic sensitivity. While bulky systems can achieve high sensitivity, endoscopic probes commonly suffer from inefficient fluorescence collection and reduced performance. Here we resolve this trade-off and present a miniaturized diamond quantum magnetometer with a 6 mm diameter endoscopic sensor head, achieving a magnetic-field sensitivity of 91 pT/sqrt(Hz) with a 2 kHz measurement bandwidth in a magnetically unshielded environment. The fluorescence collection bottleneck is overcome by separating excitation and collection into different cores of a fused multi-core fiber bundle, coupled to the diamond through a custom high-numerical-aperture micro-objective. A compact FPGA-based backend performs microwave control, lock-in detection and real-time resonance tracking, enabling robust operation during magnetic-field imaging. To demonstrate the practical utility of the miniaturized sensor, we image the magnetic field of a commercial lithium-ion pouch cell during charge and discharge and reconstruct depth-integrated current-density maps of the current flow. These results show that endoscopic diamond magnetometers can combine high sensitivity with a probe geometry suitable for confined, unshielded measurements, opening new avenues in battery technology and beyond.
Airborne magnetometry requires rigorous calibration to isolate geomagnetic signals from sensor errors and platform magnetic fields. This magnetic compensation is needed for applications like geophysical exploration and magnetic anomaly navigation. The standard approach utilizes a quantum scalar Optically Pumped Magnetometer (OPM) and a less sensitive fluxgate vector sensor for attitude information. This configuration typically results in a scalar approximation of the platform field. Advancements in high-sensitivity Diamond Nitrogen-Vacancy (NV) vector magnetometers now enable a re-evaluation of the standard hardware configuration and full vector calibration models. We show through rigorous theoretical analysis that scalar calibration models are robust to misalignment. Vector calibration models, however, are intrinsically first-order sensitive to attitude errors, irrespective of the accuracy of the magnetic field measurements. These errors arise from inaccurate representation of the background field direction in the body frame, and can amplify small orientation errors into noticeable calibration residuals. Using realistic sensor models and flight trajectories, we evaluate different sensor configurations for magnetic calibration and assess the use of onboard Inertial Navigation Systems (INS) as an independent attitude reference to enable stable compensation. Our results suggest that quantum vector magnetometers like NV sensors are not sufficient to solve the attitude bottleneck for airborne vector magnetic calibration. However, as a single sensor capable of providing both absolute field and directional measurements, they may offer benefits regarding sensor placement, synchronization, and scalar calibration accuracy.