Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Spontaneous Radiation Bounds on Collapse Models: Recomputed Emission Rates for Germanium Detectors

William Alexander Aldred

Published Nov 11, 2026• 0 citations
Publisher

Abstract

This paper recomputes relative spontaneous-radiation rates for collapse models under the scaling with collapse rate and correlation length used in detector analyses, normalised to a stated reference point. At the conventional parameters the normalised rate is 1.00e-03 in the units adopted here; raising the collapse rate to 1e-10 per second raises the emission to 1.000e+03, while widening the correlation length to one micrometre lowers it to 1.000e-05. The inverse-square dependence on correlation length means radiation searches and interferometric searches probe complementary directions in parameter space, and neither alone closes the plane. All rates here are relative to the stated normalisation; absolute detector limits require the full spectral calculation. The study is simulated and computed from stated assumptions; it is not a measurement.

DOI
10.5281/zenodo.24145218

Related papers

Granular Localisation Length and the Minimum Length: Bounds on Spontaneous Collapse Width from Interferometry

William Alexander Aldred

This paper examines whether a fundamental minimum length constrains the correlation length used in spontaneous collapse models. The Planck length is 1.616e-35 metres. For a superposition of one million nucleons separated by one hundred nanometres, the computed collapse-induced decoherence rate varies from 1.000e-10 per second when the correlation length is ten nanometres to 2.500e-15 per second when it is ten micrometres, with 2.212e-11 per second at the conventional one hundred nanometres. Every correlation length under laboratory discussion exceeds the Planck length by more than twenty orders of magnitude, so the minimum length imposes no practical restriction on the parameter; interferometry, not geometry, is what narrows the allowed interval. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Atomic correlation effects in collapse-induced spontaneous radiation

Simone Manti, Nicola Bortolotti, Lajos Diósi +2 more

Collapse models introduce stochastic and nonlinear modifications in the quantum dynamics, predicting observable effects, such as spontaneous radiation from charged particles, which can be used to constrain their parameters. Recently, attention has focused on the 1-100 keV energy range, where the wavelength of the emitted photons becomes comparable to atomic dimensions, making the emission sensitive to atomic structure and leading to model-dependent behaviors that enable their discrimination. Here, we derive a general expression for the spontaneous emission rate for arbitrary noise, providing a framework that systematically incorporates the atomic structure through the radial distribution of the emitters, modulated by the specific collapse model. The formalism recovers previous results in the appropriate limits and naturally includes new low-energy effects, such as cancellation mechanisms arising from charge correlations. We evaluate the rates for germanium and xenon within the Diósi-Penrose and Continuous Spontaneous Localization models, showing how these correlations modify the predicted emission rates. This approach provides a unified framework to account for atomic effects and enables more robust, material-dependent experimental constraints on collapse model parameters.

quant-pharXiv:2608.07205•Aug 10, 2026•1 citation

Continuous Spontaneous Localisation Rates Implied by a Maximum Density: A Computed Bound and Laboratory Comparison

William Alexander Aldred

This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Experimental constrains on the Continuous Spontaneous Localization model from spontaneous radiation emission

Kristian Piscicchia, Angelo Bassi, Catalina Curceanu +3 more

The work presented in this paper aimed to obtain new, more stringent, limits on the parameters of the Continuous Spontaneous Localization collapse model. The result is accomplished by performing a Bayesian analysis of the X-ray emission data collected by the IGEX collaboration, compared with the spontaneous photon emission which is predicted by collapse models. The most stringent limits on the collapse rate $\lambda$ and the correlation length $r_C$ of the CSL model are obtained , with respect to any other method, over a broad range of the parameters space.

Corfu Summer Institute School and Workshops on Elementary Particle Physics and Gravity (CORFU)•Aug 22, 2018•0 citations

CSL Collapse Model Mapped with the Spontaneous Radiation

Kristian Piscicchia, Angelo Bassi, Catalina Curceanu +4 more

In this paper, new upper limits on the parameters of the Continuous Spontaneous Localization (CSL) collapse model are extracted. To this end, the X-ray emission data collected by the IGEX collaboration are analyzed and compared with the spectrum of the spontaneous photon emission process predicted by collapse models. This study allows the obtainment of the most stringent limits within a relevant range of the CSL model parameters, with respect to any other method. The collapse rate λ and the correlation length r C are mapped, thus allowing the exclusion of a broad range of the parameter space.

arXiv:1710.01973•Entropy•Jun 29, 2017•92 citations

Collapse-Model Force Noise in Gravitational-Wave Interferometers: Computed Spectral Density Against Detector Noise

William Alexander Aldred

This paper estimates, under an explicitly stated normalisation, the displacement noise that collapse-model force fluctuations would produce in a gravitational-wave interferometer and compares it with representative detector sensitivity. The displacement amplitude spectral density is 6.333e-29 metres per root hertz at the conventional collapse rate and 6.333e-25 metres per root hertz at a rate of 1e-08 per second, against a representative detector level of 1.00e-19 metres per root hertz near one hundred hertz. On this normalisation the conventional rate lies below detector noise and the stronger rate lies above it, which is why interferometer data already inform the upper part of the parameter range. The normalisation is the main uncertainty and is stated openly. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations
This paper recomputes relative spontaneous-radiation rates for collapse models under the scaling with collapse rate and correlation length used in detector analyses, normalised to a stated reference point. At the conventional parameters the normalised rate is 1.00e-03 in the units adopted here; raising the collapse rate to 1e-10 per second raises the emission to 1.000e+03, while widening the correlation length to one micrometre lowers it to 1.000e-05. The inverse-square dependence on correlation length means radiation searches and interferometric searches probe complementary directions in parameter space, and neither alone closes the plane. All rates here are relative to the stated normalisation; absolute detector limits require the full spectral calculation. The study is simulated and computed from stated assumptions; it is not a measurement.
This paper examines whether a fundamental minimum length constrains the correlation length used in spontaneous collapse models. The Planck length is 1.616e-35 metres. For a superposition of one million nucleons separated by one hundred nanometres, the computed collapse-induced decoherence rate varies from 1.000e-10 per second when the correlation length is ten nanometres to 2.500e-15 per second when it is ten micrometres, with 2.212e-11 per second at the conventional one hundred nanometres. Every correlation length under laboratory discussion exceeds the Planck length by more than twenty orders of magnitude, so the minimum length imposes no practical restriction on the parameter; interferometry, not geometry, is what narrows the allowed interval. The study is simulated and computed from stated assumptions; it is not a measurement.
Collapse models introduce stochastic and nonlinear modifications in the quantum dynamics, predicting observable effects, such as spontaneous radiation from charged particles, which can be used to constrain their parameters. Recently, attention has focused on the 1-100 keV energy range, where the wavelength of the emitted photons becomes comparable to atomic dimensions, making the emission sensitive to atomic structure and leading to model-dependent behaviors that enable their discrimination. Here, we derive a general expression for the spontaneous emission rate for arbitrary noise, providing a framework that systematically incorporates the atomic structure through the radial distribution of the emitters, modulated by the specific collapse model. The formalism recovers previous results in the appropriate limits and naturally includes new low-energy effects, such as cancellation mechanisms arising from charge correlations. We evaluate the rates for germanium and xenon within the Diósi-Penrose and Continuous Spontaneous Localization models, showing how these correlations modify the predicted emission rates. This approach provides a unified framework to account for atomic effects and enables more robust, material-dependent experimental constraints on collapse model parameters.
This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.
The work presented in this paper aimed to obtain new, more stringent, limits on the parameters of the Continuous Spontaneous Localization collapse model. The result is accomplished by performing a Bayesian analysis of the X-ray emission data collected by the IGEX collaboration, compared with the spontaneous photon emission which is predicted by collapse models. The most stringent limits on the collapse rate λ\lambdaλ and the correlation length rCr_CrC​ of the CSL model are obtained , with respect to any other method, over a broad range of the parameters space.
In this paper, new upper limits on the parameters of the Continuous Spontaneous Localization (CSL) collapse model are extracted. To this end, the X-ray emission data collected by the IGEX collaboration are analyzed and compared with the spectrum of the spontaneous photon emission process predicted by collapse models. This study allows the obtainment of the most stringent limits within a relevant range of the CSL model parameters, with respect to any other method. The collapse rate λ and the correlation length r C are mapped, thus allowing the exclusion of a broad range of the parameter space.
This paper estimates, under an explicitly stated normalisation, the displacement noise that collapse-model force fluctuations would produce in a gravitational-wave interferometer and compares it with representative detector sensitivity. The displacement amplitude spectral density is 6.333e-29 metres per root hertz at the conventional collapse rate and 6.333e-25 metres per root hertz at a rate of 1e-08 per second, against a representative detector level of 1.00e-19 metres per root hertz near one hundred hertz. On this normalisation the conventional rate lies below detector noise and the stronger rate lies above it, which is why interferometer data already inform the upper part of the parameter range. The normalisation is the main uncertainty and is stated openly. The study is simulated and computed from stated assumptions; it is not a measurement.