Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Single Ion Addressing for Long Ion Strings

GIORGIO CIOCCA

Published Oct 14, 2026• 0 citations
OpenAlex

Abstract

This Master’s thesis was dedicated to the design, assembly, and experimental characterisation of a novel single-ion addressing system for the linear Paul trap of the QSim experiment at IQOQI Innsbruck. The recently upgraded linear trap in the experiment, which is capable of confining chains of 100 or more Calcium-40 ions, made it necessary to build a suitable single-site addressing apparatus. Said new addressing system should be capable of handling an expected chain length of at least 460 µm and an inter-ion spacing as small as 2.6 µm, all while maintaining a resonant crosstalk level below 0.3. To overcome the limitations of addressing such extended strings with a single beam, a novel structural geometry was implemented: the system utilizes two independent Acousto-Optic Deflectors (AODs), each responsible for steering a laser beam over one half of the ion chain, the outputs of which are combined via a beam splitter onto a common path. The optical design was guided by geometrical and practical constraints, together with ray and physical optics principles, relying on Zemax OpticStudio simulations to verify the performance of the design. A Keplerian beam expander, featuring a Hastings triplet and a composite collimation stage, was chosen to achieve the desired beam size right before the final focusing onto the ions. Such a design was chosen in order to reduce aberrations of the beam to a minimum. Furthermore, custom mechanical mounts were designed in Solidworks to ensure maximum control and modularity of the resulting setup within the tight constraints of the main experiment. Following its construction, the system was thoroughly characterised on a test bench, using a substitute objective for preliminary tests. The output beam was reconstructed using sub-pixel resolution using the Drizzle algorithm, yielding focused waist radii ranging between 1.1 µm and 1.5 µm. Such beam radii were within the design tolerances required to maintain acceptable levels of crosstalk. Extrapolation of the beam steering demonstrated an addressable length of 549(5) µm, comfortably exceeding the 460 µm requirement. Finally, the setup was integrated into the main experiment and validated through a series of proof-of-concept operations on actual ion chains. The measured crosstalk across a 100-ion chain remained below the 0.3 threshold, peaking at 0.186(2) for one AOD and 0.206(3) for the other. The setup successfully allows for the preparation of benchmark states such as Néel states with roughly 90% fidelity. Furthermore, the ability of the system to create arbitrary product states and to reconstruct them via quantum state tomography across the whole crystal was tested by preparing |xyzxyz . . . ⟩ states and performing both single-site and pairwise state tomography on them.

Related papers

AOD-based Individual Addressing of a Long Linear Trapped-Ion Chain

Jiyong Yu, Kavyashree Ranawat, Andrew Van Horn +4 more

We present the design and characterization of a beam-steering system based on acousto-optic deflectors (AODs) and experimentally demonstrate individual addressing of a 30-qubit linear trapped-ion chain.

Conference on Lasers and Electro-Optics•Jan 1, 2026•0 citations

Design and Characterization of Compact Acousto-Optic-Deflector Individual Addressing System for Trapped-Ion Quantum Computing

Jiyong Yu, Kavyashree Ranawat, Andrew Van Horn +4 more

We present a compact design for a beam-steering system based on acousto-optic-deflectors (AODs) used as an individual addressing system for trapped-ion quantum computing. The design targets to minimize the optomechanical degrees of freedom and the optical beam paths to improve optical stability, and we successfully implemented a solution with a compact footprint of less than 1 square foot. The system characterization results show that we achieve clean Gaussian beams at 355nm wavelength with a beam steering range of $\sim$50 times the beam diameter, and an intensity crosstalk of $< 9 \times 10^{-4}$ at all neighboring ions in a five-ion chain. Based on these capabilities, we experimentally demonstrate individual addressing of a 30-ion chain. We estimate the beam switching time of the AOD to be $\sim$240 ns. The compact system design is expected to provide high optical stability, providing the potential for high-fidelity trapped-ion quantum computing with long ion chains.

quant-pharXiv:2601.01647•Jan 6, 2026•2 citations

Low cross-talk optical addressing of trapped-ion qubits using a novel integrated photonic chip

Ana Sotirova, Bangshan Sun, Jamie Leppard +10 more

Abstract Individual optical addressing in chains of trapped atomic ions requires the generation of many small, closely spaced beams with low cross-talk. Furthermore, implementing parallel operations necessitates phase, frequency, and amplitude control of each individual beam. Here, we present a scalable method for achieving all of these capabilities using a high-performance integrated photonic chip coupled to a network of optical fibre components. The chip design results in very low cross-talk between neighbouring channels even at the micrometre-scale spacing by implementing a very high refractive index contrast between the channel core and cladding. Furthermore, the photonic chip manufacturing procedure is highly flexible, allowing for the creation of devices with an arbitrary number of channels as well as non-uniform channel spacing at the chip output. We present the system used to integrate the chip within our ion trap apparatus and characterise the performance of the full individual addressing setup using a single trapped ion as a light-field sensor. Our measurements showed intensity cross-talk below ~10 –3 across the chip, with minimum observed cross-talk as low as ~10 –5 .

arXiv:2310.13419•Light Science & Applications•Aug 20, 2024•30 citations

Stabilization and control in a linear ion trap

J.-P. Stacey

This thesis describes experimental work towards developing a trapped ion quantum information processor. An existing ion trap apparatus was capable of trapping and laser-cooling single ions or small ion strings of 40 Ca+, and had been used for studies of quantum jumps and natural lifetime measurements in Ca. This thesis describes improvements in this apparatus, which have allowed the stability and the flexibility of experimental control of the ions to be greatly increased. This enabled experiments to read out the spin state of a single trapped ion, and to load ions with isotope selectivity through photoionization. The optical systems were improved by installation of new lasers, optical reference cavities, and a system of acousto-optic modulators for laser intensity switching and frequency control. The photon counting for fluorescence detection was improved, and a new photon time-of-arrival correlation circuit developed. This has permitted rapid and more sensitive detection of micromotion, and hence cancellation of stray fields in the trap. A study of resonant circuits in the low RF, high voltage (10 MHz, 1 kV) regime was carried out with a view to developing a new RF supply for the Paul trap with reduced noise and increased power. A new supply based on a helical resonator was built and used to trap ions. This technique has reduced noise and will permit higher secular frequencies to be attained in the future. A magnetic field B in the ion trap is used to define a quantization axis, and in one series of experiments was required to be of order 100 G to provide a substantial Zeeman splitting. A set of magnetic field coils to control the size and direction of B is described. The design of these posed some problems owing to an unforseen issue with the vacuum chamber. In short, it is magnetizable and acts to first approximation like a magnetic shield. The field coils had to be sufficiently substantial to produce the desired field at the ion even in the presence of this shielding effect, and dark resonance (and other) spectra with Zeeman splitting were obtained to calibrate the field using the ion as a probe. Finally, the thesis describes the successful loading of the ion trap by laser photoionization from a weak atomic beam. This involved two new lasers at 423 nm and 389 nm. Saturated absorption spectroscopy of neutral calcium is first described, then transverse excitation of an atomic beam in our vacuum chamber is used to identify all the main isotopes of calcium and confirm their abundances in our source (a heated sample of natural calcium). Finally, photoionization is used to load the trap. This has three advantages over electron-impact ionization. By avoiding an electron gun, we avoid charging of insulating patches and subsequent electric field drift as they discharge; the flux in the atomic beam and hence calcium (and other) deposits on the electrodes can be greatly reduced; and most importantly, the photoionization is isotope selective. Evidence is presented which suggests that even with an non-enriched source, the rare isotope 43 Ca can be loaded with reasonable efficiency. This isotope is advantageous for quantum information experiments for several reasons, but chiefly because its ground state hyperfine structure can act as a stable qubit.

•Jan 1, 2003•6 citations

UV laser-based addressing unit for trapped-ion quantum computers

Marcus Babin, Erik Beckert, Peter Schreiber +2 more

Laser-based addressing units are core components for trapped-ion quantum computers, in which ions are held in defined, separate, micron-scale position fields and are brought into different qubit states via an addressing beam with an ion-specific wavelength. The spin of the valence electrons of the atomic ions represents the qubits states. An addressing action causes a stimulated Raman transition, which in turn causes a change in electron spin and thus a qubit rotation. Our unit is designed for 10 40Ca+ ions kept in a linear microchip ion trap. The hardware platform utilizes waveguides with integrated collimating micro lenses, followed by a cascaded 4f optical setup, consisting of a focusing and a beam expander unit. An aspherical lens realizes a lateral shift tolerant focus inside the trap. The addressing unit achieves minimal foci beam waists of 1.1 μm, with a minimal ion separation of 5.31 μm. The operating addressing wavelength ranges from 395 nm to 405 nm. Fault relevant ion crosstalk ratio is less than 10−4. Addressing operations can be conducted in parallel on all captured ions. The specified laser-based addressing unit provides a stable and low-error solution for qubit operations with coherence times of several seconds. Further adaptions of the waveguide structures and the implementation of micro optical lenses offer the potential of fully integrating the system into the microchip ion trap. Such a quasi-monolithic trap integration constitutes a compact, and highly scalable addressing and detection system with the ability to address as many qubit registers as the ion trap capacity allows.

Quantum Technology: Driving Commercialisation of an Enabling Science•Jan 11, 2023•1 citation

Laser addressing of individual ions in a linear ion trap

Hanns‐Christoph Nägerl, Dietrich G. Leibfried, H. J. Rohde +4 more

Single ions in a linear string have been addressed with a tightly focused laser beam and an acousto-optic deflector. The excitation into a long-lived metastable level is detected with a quantum jump technique. Single-quantum bit operations for quantum information processing with trapped ions are shown to be feasible.

Physical Review A•Jul 1, 1999•191 citations
This Master’s thesis was dedicated to the design, assembly, and experimental characterisation of a novel single-ion addressing system for the linear Paul trap of the QSim experiment at IQOQI Innsbruck. The recently upgraded linear trap in the experiment, which is capable of confining chains of 100 or more Calcium-40 ions, made it necessary to build a suitable single-site addressing apparatus. Said new addressing system should be capable of handling an expected chain length of at least 460 µm and an inter-ion spacing as small as 2.6 µm, all while maintaining a resonant crosstalk level below 0.3. To overcome the limitations of addressing such extended strings with a single beam, a novel structural geometry was implemented: the system utilizes two independent Acousto-Optic Deflectors (AODs), each responsible for steering a laser beam over one half of the ion chain, the outputs of which are combined via a beam splitter onto a common path. The optical design was guided by geometrical and practical constraints, together with ray and physical optics principles, relying on Zemax OpticStudio simulations to verify the performance of the design. A Keplerian beam expander, featuring a Hastings triplet and a composite collimation stage, was chosen to achieve the desired beam size right before the final focusing onto the ions. Such a design was chosen in order to reduce aberrations of the beam to a minimum. Furthermore, custom mechanical mounts were designed in Solidworks to ensure maximum control and modularity of the resulting setup within the tight constraints of the main experiment. Following its construction, the system was thoroughly characterised on a test bench, using a substitute objective for preliminary tests. The output beam was reconstructed using sub-pixel resolution using the Drizzle algorithm, yielding focused waist radii ranging between 1.1 µm and 1.5 µm. Such beam radii were within the design tolerances required to maintain acceptable levels of crosstalk. Extrapolation of the beam steering demonstrated an addressable length of 549(5) µm, comfortably exceeding the 460 µm requirement. Finally, the setup was integrated into the main experiment and validated through a series of proof-of-concept operations on actual ion chains. The measured crosstalk across a 100-ion chain remained below the 0.3 threshold, peaking at 0.186(2) for one AOD and 0.206(3) for the other. The setup successfully allows for the preparation of benchmark states such as Néel states with roughly 90% fidelity. Furthermore, the ability of the system to create arbitrary product states and to reconstruct them via quantum state tomography across the whole crystal was tested by preparing |xyzxyz . . . ⟩ states and performing both single-site and pairwise state tomography on them.
We present a compact design for a beam-steering system based on acousto-optic-deflectors (AODs) used as an individual addressing system for trapped-ion quantum computing. The design targets to minimize the optomechanical degrees of freedom and the optical beam paths to improve optical stability, and we successfully implemented a solution with a compact footprint of less than 1 square foot. The system characterization results show that we achieve clean Gaussian beams at 355nm wavelength with a beam steering range of $\sim$50 times the beam diameter, and an intensity crosstalk of <9×10−4< 9 \times 10^{-4}<9×10−4 at all neighboring ions in a five-ion chain. Based on these capabilities, we experimentally demonstrate individual addressing of a 30-ion chain. We estimate the beam switching time of the AOD to be $\sim$240 ns. The compact system design is expected to provide high optical stability, providing the potential for high-fidelity trapped-ion quantum computing with long ion chains.
Abstract Individual optical addressing in chains of trapped atomic ions requires the generation of many small, closely spaced beams with low cross-talk. Furthermore, implementing parallel operations necessitates phase, frequency, and amplitude control of each individual beam. Here, we present a scalable method for achieving all of these capabilities using a high-performance integrated photonic chip coupled to a network of optical fibre components. The chip design results in very low cross-talk between neighbouring channels even at the micrometre-scale spacing by implementing a very high refractive index contrast between the channel core and cladding. Furthermore, the photonic chip manufacturing procedure is highly flexible, allowing for the creation of devices with an arbitrary number of channels as well as non-uniform channel spacing at the chip output. We present the system used to integrate the chip within our ion trap apparatus and characterise the performance of the full individual addressing setup using a single trapped ion as a light-field sensor. Our measurements showed intensity cross-talk below ~10 –3 across the chip, with minimum observed cross-talk as low as ~10 –5 .
This thesis describes experimental work towards developing a trapped ion quantum information processor. An existing ion trap apparatus was capable of trapping and laser-cooling single ions or small ion strings of 40 Ca+, and had been used for studies of quantum jumps and natural lifetime measurements in Ca. This thesis describes improvements in this apparatus, which have allowed the stability and the flexibility of experimental control of the ions to be greatly increased. This enabled experiments to read out the spin state of a single trapped ion, and to load ions with isotope selectivity through photoionization. The optical systems were improved by installation of new lasers, optical reference cavities, and a system of acousto-optic modulators for laser intensity switching and frequency control. The photon counting for fluorescence detection was improved, and a new photon time-of-arrival correlation circuit developed. This has permitted rapid and more sensitive detection of micromotion, and hence cancellation of stray fields in the trap. A study of resonant circuits in the low RF, high voltage (10 MHz, 1 kV) regime was carried out with a view to developing a new RF supply for the Paul trap with reduced noise and increased power. A new supply based on a helical resonator was built and used to trap ions. This technique has reduced noise and will permit higher secular frequencies to be attained in the future. A magnetic field B in the ion trap is used to define a quantization axis, and in one series of experiments was required to be of order 100 G to provide a substantial Zeeman splitting. A set of magnetic field coils to control the size and direction of B is described. The design of these posed some problems owing to an unforseen issue with the vacuum chamber. In short, it is magnetizable and acts to first approximation like a magnetic shield. The field coils had to be sufficiently substantial to produce the desired field at the ion even in the presence of this shielding effect, and dark resonance (and other) spectra with Zeeman splitting were obtained to calibrate the field using the ion as a probe. Finally, the thesis describes the successful loading of the ion trap by laser photoionization from a weak atomic beam. This involved two new lasers at 423 nm and 389 nm. Saturated absorption spectroscopy of neutral calcium is first described, then transverse excitation of an atomic beam in our vacuum chamber is used to identify all the main isotopes of calcium and confirm their abundances in our source (a heated sample of natural calcium). Finally, photoionization is used to load the trap. This has three advantages over electron-impact ionization. By avoiding an electron gun, we avoid charging of insulating patches and subsequent electric field drift as they discharge; the flux in the atomic beam and hence calcium (and other) deposits on the electrodes can be greatly reduced; and most importantly, the photoionization is isotope selective. Evidence is presented which suggests that even with an non-enriched source, the rare isotope 43 Ca can be loaded with reasonable efficiency. This isotope is advantageous for quantum information experiments for several reasons, but chiefly because its ground state hyperfine structure can act as a stable qubit.
Laser-based addressing units are core components for trapped-ion quantum computers, in which ions are held in defined, separate, micron-scale position fields and are brought into different qubit states via an addressing beam with an ion-specific wavelength. The spin of the valence electrons of the atomic ions represents the qubits states. An addressing action causes a stimulated Raman transition, which in turn causes a change in electron spin and thus a qubit rotation. Our unit is designed for 10 40Ca+ ions kept in a linear microchip ion trap. The hardware platform utilizes waveguides with integrated collimating micro lenses, followed by a cascaded 4f optical setup, consisting of a focusing and a beam expander unit. An aspherical lens realizes a lateral shift tolerant focus inside the trap. The addressing unit achieves minimal foci beam waists of 1.1 μm, with a minimal ion separation of 5.31 μm. The operating addressing wavelength ranges from 395 nm to 405 nm. Fault relevant ion crosstalk ratio is less than 10−4. Addressing operations can be conducted in parallel on all captured ions. The specified laser-based addressing unit provides a stable and low-error solution for qubit operations with coherence times of several seconds. Further adaptions of the waveguide structures and the implementation of micro optical lenses offer the potential of fully integrating the system into the microchip ion trap. Such a quasi-monolithic trap integration constitutes a compact, and highly scalable addressing and detection system with the ability to address as many qubit registers as the ion trap capacity allows.