An exact operational selector specifies which candidate maps are nonnegative on declared preparation and effect resources. This paper studies finite-count calibration of that resource-dependent question for a qubit apparatus with an inert qubit reference, an arbitrary complex physical preparation, and an arbitrary physical binary detector, relative to a trusted common calibration frame. Two preparation-stabilizer settings and six separable detector probes control the statistic of the affine family (1 − θ)id + θT, 0 ≤ θ ≤ 1, uniformly over all compatible state–effect pairs. The explicit radius is 3h + √(2s), where h is a simultaneous detector calibration width and s is a one-sided bound on Bell infidelity. It yields simultaneous inner and outer confidence sets for a one-parameter slice of the declared safe-map class. A fixed allocation of 200,000 trials per calibration setting, totaling 1,600,000 calibration trials, gives false-implication probability at most 0.005 and transpose-exclusion power at least 0.996 at the specified physical alternative. The calibration confidence budgets are 0.001 for preparation and 0.004 for the detector. This exclusion calculation uses no target stream; the acquired calibration circuits can use identity wiring. Coverage and prospective power remain separate statements. The acquisition contract uses fixed-length iid Bernoulli streams with their stated physical means and permits coupling between whole streams. The numerical example sets external-reference systematic errors to zero, and its trial budget excludes establishing reference trust and accuracy. If the preparation and detector references are not linked, the paper constructs two physical identity-wired apparatus worlds with identical complete record laws under the specified independent acquisition construction but different safety conclusions on the fixed target cone pair. A secondary nearest-center theorem supplies unconditional error control for the joint event of a wrong and nonabstaining candidate label under an additional finite-context target-law contract. Its nonidentity candidates are not completely positive maps, and their ideal probabilities lie below the nominal detector’s ordinary positive-output floor. That target law is an explicit model assumption; the label theorem is not a conditional-correctness or posterior statement. The results are analytic and prospective. The number of settings and trial allocations are sufficient constructions, with no empirical success-rate, minimality, optimal sample-complexity, or general certified count-to-feasibility implementation claim. The scope is one declared qubit apparatus, target preparation ray and binary effect cone, and affine map slice. The common complex operator description, trusted reference relationship and physical calibration probability law are assumptions. Exact finite checks and an assessed supporting Lean subset accompany the manuscript. That subset covers 326 audited named declarations: 240 theorems and 86 definition/type interfaces. Analytic binomial coverage, concentration and acquisition bridges, independent-product-law construction and normalization, and the complete noisy-power chain remain outside the accepted Lean subset. That subset does not establish a certified numerical feasibility evaluator, a complete physical two-sector implementation, or an ordinary-channel realization. AI assistance and the dated review/correction provenance are disclosed in the manuscript and companion records. No experimental dataset, external human peer review, or end-to-end formal verification is claimed.
An exact operational selector specifies which candidate maps are nonnegative on declared preparation and effect resources. This paper studies finite-count calibration of that resource-dependent question for a qubit apparatus with an inert qubit reference, an arbitrary complex physical preparation, and an arbitrary physical binary detector, relative to a trusted common calibration frame. Two preparation-stabilizer settings and six separable detector probes control the statistic of the affine family (1 − θ)id + θT, 0 ≤ θ ≤ 1, uniformly over all compatible state–effect pairs. The explicit radius is 3h + √(2s), where h is a simultaneous detector calibration width and s is a one-sided bound on Bell infidelity. It yields simultaneous inner and outer confidence sets for a one-parameter slice of the declared safe-map class. A fixed allocation of 200,000 trials per calibration setting, totaling 1,600,000 calibration trials, gives false-implication probability at most 0.005 and transpose-exclusion power at least 0.996 at the specified physical alternative. The calibration confidence budgets are 0.001 for preparation and 0.004 for the detector. This exclusion calculation uses no target stream; the acquired calibration circuits can use identity wiring. Coverage and prospective power remain separate statements. The acquisition contract uses fixed-length iid Bernoulli streams with their stated physical means and permits coupling between whole streams. The numerical example sets external-reference systematic errors to zero, and its trial budget excludes establishing reference trust and accuracy. If the preparation and detector references are not linked, the paper constructs two physical identity-wired apparatus worlds with identical complete record laws under the specified independent acquisition construction but different safety conclusions on the fixed target cone pair. A secondary nearest-center theorem supplies unconditional error control for the joint event of a wrong and nonabstaining candidate label under an additional finite-context target-law contract. Its nonidentity candidates are not completely positive maps, and their ideal probabilities lie below the nominal detector’s ordinary positive-output floor. That target law is an explicit model assumption; the label theorem is not a conditional-correctness or posterior statement. The results are analytic and prospective. The number of settings and trial allocations are sufficient constructions, with no empirical success-rate, minimality, optimal sample-complexity, or general certified count-to-feasibility implementation claim. The scope is one declared qubit apparatus, target preparation ray and binary effect cone, and affine map slice. The common complex operator description, trusted reference relationship and physical calibration probability law are assumptions. Exact finite checks and an assessed supporting Lean subset accompany the manuscript. That subset covers 326 audited named declarations: 240 theorems and 86 definition/type interfaces. Analytic binomial coverage, concentration and acquisition bridges, independent-product-law construction and normalization, and the complete noisy-power chain remain outside the accepted Lean subset. That subset does not establish a certified numerical feasibility evaluator, a complete physical two-sector implementation, or an ordinary-channel realization. AI assistance and the dated review/correction provenance are disclosed in the manuscript and companion records. No experimental dataset, external human peer review, or end-to-end formal verification is claimed.
Finite local calibration does not by itself determine how a preparation and a detector are related through a joint physical transport. We study the ancilla-orientation family A_theta(rho) = (1-theta)rho + theta rho^Gamma for an arbitrary two-qubit state rho and binary effect E, followed by an unknown joint completely positive trace-preserving channel. Eight jointly transmitted product inputs, comprising the complete X tensor X and Z tensor Z bases, give a complementary-basis bound on the channel's Choi infidelity. A channel-distance estimate and the retained local calibration bound then yield the uniform selector enclosure b_E + sqrt(2 s_rho) + (1+theta)epsilon, including the generally nonpositive candidate. One physical compatibility set gives simultaneous inner and outer confidence intervals for the restricted safe class. A sufficient fixed allocation of 21,600,000 trials has coverage at least 0.99; an explicit integer rule has transpose-exclusion power at least 0.996 at a stated alternative and an accepted upper endpoint at most -0.000620. The construction consumes 43,200,000 prepared qubit instances. Conversely, an exact joint channel can fix every isolated-leg input with the other leg held in |0>, remain at maximal half diamond distance from identity, and change the safe interval while preserving the complete permitted record law. A one-basis phase-channel obstruction provides a second control. The result combines established process-verification methods with a finite-count safety certificate and precisely specified weaker-record obstructions. Compatible complex types, bounded controls, a common transport context, and declared drift remain explicit premises. The source-and-evidence companion preserves the paper-specific Lean sources and historical execution, exact numerical programs and receipts, the separate AI-assisted review return, and the release source/build/validation records. Formal support remains conditional on eleven analytic-law inputs and three acquisition contracts. No end-to-end formal verification, experimental validation, or external human peer review is claimed. Release rights are scoped by component: CC BY 4.0 for the article and author-owned documentation/data; a newly prepared MIT grant for original author-owned software and Lean sources; and the original licenses and notices for third-party or inherited material. The companion rights notice specifies the scope and exclusions.
RTCG-P5, version 1.0, establishes finite-count passing guarantees for a target-centered certificate of a prescribed quantum instrument on a specified family of imperfect preparations. Six rank-two states share one signed, support-preserving parameter epsilon in [-10^(-6),10^(-6)]. The diagnostic instrument is fixed; actual readouts and trusted references remain nominal. Both the new rule and the old scalar rule use the same acquired preparation allowances. An explicit doubled fixed allocation of 636776064000000000000 attempted trials yields the upward-reported sufficient upper 0.000098454319447, strictly below 10^(-4). For every fixed parameter in the family and every allowed coupling between settings, the new rule passes with probability at least 1 - 873 exp(-12), approximately 0.994636102615544. Trials are iid within each setting; independence across settings is not assumed. The original allocation's sufficient envelope is 0.000108332505187 and does not close. This does not establish failure of the actual rule or a necessary acquisition cost. A separate single-analyzer argument proves an actual-output obstruction for the unchanged scalar preparation-penalty rule. At either signed endpoint, its reported upper is at least 0.00672 except on an event of probability at most 2 exp(-12), for every fixed valid allocation retaining that conversion. The obstruction is specific to this rule. It is not an information-theoretic lower bound or a lower bound on the physical instrument error. The universal false-certification bound, 889 exp(-12), remains a separate inherited guarantee for complete complex CP competitors under the stated trusted-reference and shared-world contract. The family-specific power guarantee does not restrict that competitor class, and the two probability statements are not combined into one 99-percent event or a posterior correctness assertion. The manuscript and mathematical supplement provide the physical construction, concentration proofs, all signed response coefficients, whole-interval argument and exact arithmetic. The companion provides editable sources, byte-preserved numerical programs and data, supporting Lean sources, actual execution/type/axiom evidence and reader instructions. The retained Lean 4.19.0 execution supports the stated deterministic and conditional probability implications. Physical-source realization, concentration/Holder arguments, inherited unrestricted physical coverage, complete raw-count linkage and general Python refinement retain their explicit formal boundaries. Packaging the public release is not a new Lean execution. This is a new finite-count extension of RTCG-P4, Target-Centered Preparation Calibration for Outcome-Resolved Instrument Certification (10.5281/zenodo.23789860). No experimental acquisition, practical sample efficiency, fewer-shot result or optimal acquisition cost is claimed. Manuscript, supplement, documentation and author-owned mathematical data use CC BY 4.0; original numerical, checking, build and Lean code use MIT. Inherited and third-party notices remain authoritative for their material.
We construct a source-matched reference calibration for distinguishing the coherent law h = 0 from the specified added generator h = J/25 in a finite quantum-record model. A complete-carrier transfer bound connects an accessible reference contrast to a delayed target contrast while retaining the original drift and actual law. On reference coverage and measured admission, restricting both hypotheses by the same observed reference band yields a directed target-set separation of at least 0.0071230619 whenever both compatible classes are nonempty. Rival worlds may have different admitted nuisance parameters. The constants are uniform over independently known finite lengths m >= 65, with tag 65, access prefix 1:32 and target deadline 25.02/J. Finite reference preparation and work/source reset satisfy the declared response budgets. Reset acts on the actual joint input and consumed supply, with the retained reference R exactly inert. It does not assign a universal reduced channel to correlated supplies. Under almost-sure conditional resource and supply bounds, the comparison extends to history-dependent acquisition. A prespecified rule, including abstention below the calibration threshold, has each-law unconditional wrong-declaration probability at most 2 exp(-6) + exp(-85/16) < 0.01. This is neither a posterior probability nor an error bound conditional on admission. The statistical step uses standard bounded-martingale concentration. Global target states and specified auxiliary supplies remain resources. Reset requires additional globally conditioned controls and has very large finite costs. The result is a conditional theorem for the two declared laws; it does not establish practical implementation or a unique diagnosis of fundamental collapse. A supporting Lean 4 companion contains 85 theorem declarations and 30 supporting definitions across Calibration, Operations and Risk. It provides checked scalar, sufficient-bound, resource-arithmetic and finite-history risk consequences under explicit premises. The companion has an executed Linux preflight and accepted returned macOS compilation, named-type and transitive-axiom evidence. The quantum constructions and conditional moment, filtration, tower and tail derivations remain written proofs or external premises; this is not an end-to-end formalization of the physical theorem chain. The original checked companion targeted author v0.4 and is carried forward unchanged, with its scope and execution chronology preserved.
Calibrated support observations can constrain a complete quantum instrument without identifying its action by unrestricted tomography. We study what those observations guarantee when the noise law is not supplied. On a fixed four-dimensional incidence-record experiment, we define the set of all complete two-outcome completely positive instruments compatible with the exact raw rejection and outcome probabilities, retaining the classical flags. Exact ideal data identify the target, but an explicit family of complete instruments reproduces the nonzero-data category laws of a low-error contamination device while admitting coherent error of square-root order. A target-ray mass certificate and a common complete-dilation comparison give a universal upper, while an exactly feasible rational instrument supplies a stronger lower witness. At the diagnostic parameter r = 1/300000000, the unhalved target-relative worst-case radius lies between 0.000258065115532250 and 0.000951566242566. The result separates avoidable inequality conservatism from information absent from the measured data. Fixed-functional and fixed-map optimizations have separately certified scopes; they do not solve the global radius. The conclusions are conditional on the supplied carrier, calibration and common-device model. They do not establish an apparatus, device-independent certification, a finite-sample power guarantee or complete formal verification. Selected supporting declarations have one recorded successful Lean 4.19.0 macOS execution and declaration-specific source, type and axiom review; this is not an end-to-end formalization.
Exact identification of a target instrument need not imply a linear stability bound for nearby observations. We study fixed finite-dimensional complete instruments with rank-one target Choi blocks, all outcomes retained, a fixed diagnostic contamination path with strictly positive branch noise, and an all-device bound on Choi mass outside the target rays. Under these hypotheses, linear prescribed-target certification is equivalent to injectivity of the joint observation and completeness map on the physical target-tangent space. An invisible nonzero tangent yields an exactly feasible positive instrument pair with square-root separation; a separate target-ray condition distinguishes sharp square-root behavior from constant-order ambiguity. For two prescribed three-basis readouts on a four-dimensional incidence-record benchmark, we obtain linear and square-root compatible-instrument radii, respectively. We then distinguish arbitrary probability residuals from simultaneous physical preparation and readout errors. Positivity and normalization give a support-amplitude estimate under which both protocols have linear calibration-only sensitivity, although their responses to contamination and unrestricted probability error differ. A fixed-sample application uses additional exactly trusted references to acquire operator-error bounds and obtain a simultaneous full-instrument confidence statement. A separate named-source power calculation reaches the prescribed error threshold with a conservative sufficient allocation of approximately 6.12 × 10^21 trials. The results concern a fixed laboratory-frame target and supplied common-device and sampling assumptions; they establish neither practical efficiency nor device-independent calibration. Written proofs are supported by exact finite certificates and a returned kernel-checked Lean subset; the full argument is not formalized end to end.
Physical Sources, Finite Detectors, Persistent Records, and Actual Events This paper develops a unified account of quantum measurement under the Admissibility and Standing Constraint (AASC) framework, connecting constructed physical sources, quantum instruments, material amplification, finite record retention, event probabilities, and the actuality of measurement outcomes. The paper distinguishes three separate objects: a complete quantum instrument containing all outcome operations, including unresolved and failed outcomes; a material record carried by a physical system whose acquisition and retention can be analyzed; an actual history describing which occurrences belong to one original experimental run. A complete instrument and a persistent material record can be constructed without assuming that linear quantum dynamics alone selects one globally definite original-run history. Conversely, the admission of an actual event does not by itself determine its probability law or conditional quantum state. The physical construction contains two complementary measurement targets: a regulated interacting gauge–Higgs–fermion source with its full source Hamiltonian retained during finite receiver pulses; an explicitly parameterized six-mode cosine circuit with source and pump interfaces, losses, distinguishable outputs, a two-polarization intrinsic-spin receiver, and a finite energy-resolving thermal amplifier. The material-registration chain includes source-code loading, driven conversion, output registration, pump-displacement removal, transfer to an intrinsic material spin, finite Gibbs-collision amplification, endpoint reading, and quiet record retention. Electronic display labels, material flags, missed counts, dark displays, blanks, and unreadable outcomes remain distinct and are retained in the joint error ledger. The paper establishes: informative bounded receivers on an interacting quantum source; finite-pulse calibration with the complete source Hamiltonian retained; a complete monitored detector model; finite preparation and amplification bounds; coherent composition of instruments and records; adaptive record composition; local-instrument compatibility; calibrated affine probability uniqueness; sharp coherent calibration limits; sequential probability laws and compatible conditional states; explicit actual-history requirements. A finite Fourier residual certificate bounds the complete monitored detector instrument over its full 35.587ms interval by 0.063241 in restricted diamond norm. Exact interval arithmetic gives seeded amplifier endpoint fidelity greater than 0.9999235242 after 1,024 finite collisions, together with an explicit conditional survival bound for a subsequent 100ms quiet hold. The probability analysis shows that positivity, density-operator dependence, affinity under classical mixtures, and calibration fix the trace probability rule for the declared readout. Approximate sector calibration alone permits coherent deviations of order the square root of the calibration error; stronger linear bounds require additional structure. The paper’s central measurement-theoretic conclusion is deliberately separated from its successful detector construction. A complete instrument admits an exclusive-history completion, but linear quantum dynamics alone does not select one such history. Source-specific preparation, reader analysis, and a bounded counting-law completion supply the additional physical input required to select an actual history. The resulting framework substantially develops the material and probabilistic parts of quantum measurement while isolating apparatus errors, actual-history law, and event-selection assumptions as explicit obligations. The work does not claim to solve every interpretation of the measurement problem, derive a universal collapse law, establish unrestricted detector accuracy, or identify a finite calibration certificate with an experimental calibration. Principal contributions A unified source-to-detector account of quantum measurement. Constructed interacting quantum sources with finite receivers. Six-mode cosine-circuit detector realization. Material registration and finite amplification chain. Two-polarization intrinsic-spin receiver. Finite thermal collision and endpoint-reading model. Full-duration restricted diamond-norm detector bound. Interval-certified amplifier fidelity. Conditional quiet-hold survival bound. Retention of blanks, wrong, unreadable, and missed outcomes. Calibrated affine probability uniqueness. Sequential instruments and compatible conditional states. Explicit separation of complete instruments, material records, and actual histories. Source-specific conditions for actual-event selection. Complete physical error and assumption ledger.