Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Procedia Computer Science

Hybrid Quantum Vision Transformer for Lung Cancer Detection from CT Scans

Bissen Abbassi, Amor Gueddana, Haythem Ghazouani, Khaoula Bedoui, Imen Ayari

Published Jan 1, 2026• 0 citations
Publisher

Abstract

Early detection of lung cancer via computed tomography (CT) scans is critical for clinical outcomes, yet the computational cost of state-of-the-art Vision Transformers limits their applicability to high-resolution volumetric data. We propose the Recurrent Quantum Self-Attention Network (RQSAN), a hybrid model combining a gated recurrent unit (GRU) contextual encoder with a measurement-free quantum self-attention module, designed to operate within the qubit and circuit-depth limits of current quantum simulators. The original QSAN evaluation [5] is restricted to the binary MNIST 0-vs-1 task at 4 × 4 resolution and includes no classical baselines. We extend this evaluation to, first, harder MNIST pairs at 8 × 8, second, the LIDC-IDRI lung nodule classification task at the same resolution, and third, matched-resolution classical baselines (logistic regression, parameter-matched MLPs).On 0-vs-1, RQSAN reproduces the published near-ceiling performance with accuracy 0.995. On the harder 4-vs-9 pair, RQSAN’s ranking ability matches the parameter-matched MLP at AUROC 0.907, while threshold accuracy collapses, revealing a readout-bandwidth bottleneck. On LIDC-IDRI at 8 × 8, all model families reach only near-chance AUROC of 0.45–0.49, revealing a second bottleneck in input resolution. We provide a fair evaluation protocol and identify the higher-resolution input-encoding problem as the central challenge for quantum-enhanced medical imaging.

DOI
10.1016/j.procs.2026.10.369

Related papers

A novel noise-resilient quantum-classical vision transformer with quantum state tomography for high-precision lung cancer classification

Sumaya Mustofa, Yousuf Rayhan Emon, Md․Zahid Hasan +1 more

Lung cancer remains the leading cause of cancer-related mortality worldwide, with accurate subtype classification being critical for improving patient outcomes. Vision Transformers (ViTs) have recently advanced medical image analysis, but their integration with quantum computing remains underexplored, leaving a gap in leveraging quantum advantages for clinical applications. This study proposes a quantum-enhanced Vision Transformer (QViT) that embeds variational quantum circuits (VQCs) within attention and feed-forward layers to enrich feature learning. To assess robustness, two circuit families, Basic VQC and Quantum Approximate Optimization Algorithm (QAOA) based VQC, were evaluated across two depths, yielding four QViT configurations. The models were analyzed through cancer classification tasks, systematic quantum state tomography (QST) to examine quantum state properties, and noise resilience testing under realistic Noisy Intermediate-Scale Quantum (NISQ) conditions, reflecting current hardware limitations. On 3150 CT (Computed Tomography) images, the QViT-QAOA-D1 configuration achieved 98.52% accuracy with a training time of 674 s, outperforming other configurations. Quantum analyses further showed that Basic VQC provides stronger entanglement but requires deeper, less NISQ-friendly circuits, whereas QAOA maintains high-purity states at shallower depths. These results suggest that QViT provides a practical and scalable framework, where quantum-enhanced representations can improve diagnostic performance while remaining compatible with current hardware constraints. Future work will focus on validation using patient-level datasets and deployment on real quantum hardware to further assess clinical applicability and scalability.

Computers & Electrical Engineering•Jun 8, 2026•0 citations

Vision transformer embeddings and quantum pyramidal circuits for biomedical image analysis

Xavier Font-Aragonès, Miguel Á. González Ballester

Abstract This work presents a novel quantum-hybrid pipeline for lung nodule classification in computed tomography (CT) scans, combining vision transformer (ViT) embeddings with quantum orthogonal pyramidal circuits (QOPCs). The approach was evaluated on 681 lung nodule CT scans across axial, coronal, and sagittal planes. Two ViT configurations were tested: ViT 1 (1 head, 4 layers) and a Bayesian-optimized ViT 2 (4 heads, 8 layers). Features extracted from ViT embedding layers were reduced via principal component analysis to 2–16 dimensions and classified using the QOPC with reconfigurable beam splitter (RBS) gates. The proposed approach achieved unprecedented compression, up to 1,470 $$\times $$ × (from 10,290 to 7 parameters) while preserving over 99% of baseline accuracy. The approach reached 83.7% accuracy (ViT 2 , $$k{=}8$$ k = 8 , $$h{=}8$$ h = 8 ) with only 46 trainable parameters and achieved computational efficiency (CE) up to 92.0. Training was accelerated up to 28 $$\times $$ × (0.030 vs. 0.833 min) while maintaining robust diagnostic performance (F1: 0.77−0.82, receiver operating characteristic area under the curve (ROC-AUC): 0.87−0.90). Ablation studies confirmed that the quantum layer outperforms conventional MLPs by +3.4% accuracy with 35% fewer parameters, while late fusion of multi-view predictions further improved performance to 85.4% accuracy and 0.92 ROC-AUC. These results establish hybrid ViT-QOPC architectures as a practical and resource-efficient framework for medical image analysis, demonstrating their ability to dramatically reduce computational cost without compromising clinical accuracy.

International Journal of Computer Assisted Radiology and Surgery•May 25, 2026•0 citations

MedQViT: A Lightweight Hybrid Quantum Vision Transformer for Medical Image Analysis

Amandeep Singh Bhatia, Mandeep Kaur Saggi

Classical Vision Transformers (CViTs) have demonstrated strong performance in medical image analysis, supporting a wide range of digital health applications. However, their self-attention mechanisms can require substantial computational resources and model parameters. In parallel, quantum machine learning (QML) has attracted increasing interest in healthcare and other scientific domains, particularly because quantum-enhanced models may provide expressive representations for small datasets. In this paper, we propose MedQViT, a robust and parameter-efficient Quantum Vision Transformer for medical image classification. To reduce the computational cost of global self-attention, MedQViT combines a shared four-qubit parameterized quantum circuit with a quantum-feature state memory and trainable landmark tokens. This hybrid architecture encodes image patches into compact quantum-enhanced representations while using classical layers for feature aggregation and classification. Experiments on established medical image datasets evaluate the effectiveness and feasibility of MedQViT against classical and quantum baselines. MedQViT achieves competitive performance with substantially fewer parameters than conventional vision models and outperforms several classical and quantum methods in terms of test accuracy (ACC) and area under the receiver operating characteristic curve (AUC).

Proceedings of the AAAI Symposium Series•Nov 6, 2026•0 citations

A hybrid quantum–classical convolutional neural network with a quantum attention mechanism for skin cancer

Pradyumn Pandey, Shrabanti Mandal

Skin cancer is the most common and fatal illness globally, and therefore, proper early detection is essential for successful treatment and enhanced patient outcomes. Classic deep learning models, especially Convolutional Neural Networks (CNNs), have greatly succeeded in medical image classification. However, classic CNNs also suffer from severe limitations such as computational inefficiency, overfitting on small datasets, and redundant feature extraction, which restrict their utility in clinical settings. To overcome these drawbacks, we introduce QAttn-CNN as a quantum–classical deep learning model combining a Quantum Attention Mechanism (QAttn) to improve feature selection and classification accuracy. Our method utilizes Quantum Convolutional Layers (QConv) and Quantum Image Representation (QIR) with Novel Enhanced Quantum Representation (NEQR) encoding to draw upon quantum parallelism and improve computational efficiency and complexity from O(N 2 ) to O(log N). The model is tested on three benchmark datasets: MNIST (70,000 grey-scale handwritten digit images), CIFAR-10 (60,000 RGB object images), and the Kaggle Skin Cancer: Malignant versus Benign dataset (3297 dermoscopic images: 1800 benign and 1497 malignant cases, from the International Skin Imaging Collaboration (ISIC) Archive). The dataset images were processed by converting them to grayscale, resizing them bilinearly to 150 × 150 pixels, and normalizing to [0–1] for quantum encoding. QAttn-CNN is contrasted with standard CNNs, QAttn-ViT (Quantum Attention Vision Transformer), and QAttn-ResNet18. Results indicate that QAttn-CNN attains state-of-the-art accuracy of 91% on the Skin Cancer dataset with a precision of 89%, a recall of 89%, and an F1-score of 91%, surpassing Baseline CNN (89% accuracy), QAttn-ViT (87%), and QAttn-ResNet18 (83%). On CIFAR-10, QAttn-CNN exhibits 10% accuracy enhancement over Baseline CNN with accuracy of 82% and 90% precision. On MNIST, QAttn-CNN performs at the peak of 99% accuracy, comparable to classical benchmarks but with greatly diminished computational overhead due to quantum parallelism. This study demonstrates the revolutionary potential of quantum-assisted deep learning in healthcare applications, especially for real-world binary medical image classification problems that identify malignant vs. benign skin lesions.

Scientific Reports•Dec 29, 2025•19 citations

Unlocking the power of quantum computing in biomedical NLP for lung cancer diagnosis

Cyrille YetuYetu Kesiku, Begonya García-Zapirain, Adel Said Elmaghraby

Lung cancer remains the leading cause of cancer-related mortality worldwide, underscoring the urgent need for accurate, efficient, and interpretable early detection methods. Existing benchmark large language models (LLMs) like ClinicalBERT and BioBERT, despite their advancements in biomedical text analysis, face critical limitations including high computational costs, limited interpretability, and reliance on extensive annotated datasets hindering their clinical integration. To address these challenges, we propose the Hybrid Attention Quantum Long Short-Term Memory-Attention (A-QLSTM-A) model, a novel quantum-classical framework that combines quantum variational circuits with LSTM networks and dual attention mechanisms. This design enhances feature extraction, improves interpretability, and offers a more efficient architectural pathway. Evaluated on MIMIC-III discharge summaries and MIMIC-IV chest radiography reports, A-QLSTM-A achieved 98.32% and 83.67% accuracy, respectively, surpassing existing models. This study establishes a new benchmark for scalable, interpretable AI in precision medicine, offering a promising tool for early lung cancer detection and clinical decision support.

Quantum Machine Intelligence•Apr 15, 2026•2 citations

HQCNN: a hybrid quantum-classical neural network with Fourier-inspired quantum attention for medical image classification

Shahjalal Khan, Jahid Karim Fahim, Pintu Chandra Paul +5 more

Medical image classification is a critical component of modern healthcare; however, accurate diagnosis remains challenging due to limited annotated datasets, class imbalance, and the high dimensionality of medical imaging data. To address these challenges, a hybrid quantum-classical neural network (HQCNN) is proposed, integrating classical deep learning with variational quantum learning for medical image classification. The proposed architecture combines a five-layer convolutional neural network (CNN) for hierarchical feature extraction with a lightweight 4-qubit variational quantum circuit (VQC) incorporating quantum state encoding, superposition and entanglement mechanisms, and a quantum attention-Fourier (QAF) module. This hybrid design aims to improve nonlinear feature representation and quantum parameter efficiency while maintaining a shallow quantum circuit suitable for noisy intermediate-scale quantum (NISQ)-era constraints. Experimental evaluation on six MedMNIST benchmark datasets demonstrated competitive performance across both binary and multi-class classification tasks. HQCNN achieved 98.88% accuracy on the binary subset of PathMNIST (classes 0 vs. 1), 97.61% accuracy on the multi-class OrganAMNIST dataset, and 86.29% accuracy on BreastMNIST. Comparative experiments and statistical analyses demonstrated consistent improvements over the controlled BHQNN baseline, while component-wise ablation studies showed that the QAF module, superposition and entanglement mechanisms, and expressive parameterized rotations contributed to classification performance in a complementary and dataset-dependent manner. Moreover, HQCNN reduced the number of trainable quantum parameters by approximately 55.6% compared with the baseline hybrid quantum neural network (BHQNN). Noise-aware simulations further showed that the model retained relatively stable predictive performance under moderate depolarizing noise, supporting further evaluation under near-term quantum computing conditions. Overall, the results demonstrate that HQCNN provides a parameter-efficient hybrid quantum-classical framework for medical image classification and offers a promising foundation for further investigation of quantum-enhanced medical image analysis.

International Journal of Advanced Technology and Engineering Exploration•Aug 31, 2026•0 citations
Early detection of lung cancer via computed tomography (CT) scans is critical for clinical outcomes, yet the computational cost of state-of-the-art Vision Transformers limits their applicability to high-resolution volumetric data. We propose the Recurrent Quantum Self-Attention Network (RQSAN), a hybrid model combining a gated recurrent unit (GRU) contextual encoder with a measurement-free quantum self-attention module, designed to operate within the qubit and circuit-depth limits of current quantum simulators. The original QSAN evaluation [5] is restricted to the binary MNIST 0-vs-1 task at 4 × 4 resolution and includes no classical baselines. We extend this evaluation to, first, harder MNIST pairs at 8 × 8, second, the LIDC-IDRI lung nodule classification task at the same resolution, and third, matched-resolution classical baselines (logistic regression, parameter-matched MLPs).On 0-vs-1, RQSAN reproduces the published near-ceiling performance with accuracy 0.995. On the harder 4-vs-9 pair, RQSAN’s ranking ability matches the parameter-matched MLP at AUROC 0.907, while threshold accuracy collapses, revealing a readout-bandwidth bottleneck. On LIDC-IDRI at 8 × 8, all model families reach only near-chance AUROC of 0.45–0.49, revealing a second bottleneck in input resolution. We provide a fair evaluation protocol and identify the higher-resolution input-encoding problem as the central challenge for quantum-enhanced medical imaging.
Lung cancer remains the leading cause of cancer-related mortality worldwide, with accurate subtype classification being critical for improving patient outcomes. Vision Transformers (ViTs) have recently advanced medical image analysis, but their integration with quantum computing remains underexplored, leaving a gap in leveraging quantum advantages for clinical applications. This study proposes a quantum-enhanced Vision Transformer (QViT) that embeds variational quantum circuits (VQCs) within attention and feed-forward layers to enrich feature learning. To assess robustness, two circuit families, Basic VQC and Quantum Approximate Optimization Algorithm (QAOA) based VQC, were evaluated across two depths, yielding four QViT configurations. The models were analyzed through cancer classification tasks, systematic quantum state tomography (QST) to examine quantum state properties, and noise resilience testing under realistic Noisy Intermediate-Scale Quantum (NISQ) conditions, reflecting current hardware limitations. On 3150 CT (Computed Tomography) images, the QViT-QAOA-D1 configuration achieved 98.52% accuracy with a training time of 674 s, outperforming other configurations. Quantum analyses further showed that Basic VQC provides stronger entanglement but requires deeper, less NISQ-friendly circuits, whereas QAOA maintains high-purity states at shallower depths. These results suggest that QViT provides a practical and scalable framework, where quantum-enhanced representations can improve diagnostic performance while remaining compatible with current hardware constraints. Future work will focus on validation using patient-level datasets and deployment on real quantum hardware to further assess clinical applicability and scalability.
Abstract This work presents a novel quantum-hybrid pipeline for lung nodule classification in computed tomography (CT) scans, combining vision transformer (ViT) embeddings with quantum orthogonal pyramidal circuits (QOPCs). The approach was evaluated on 681 lung nodule CT scans across axial, coronal, and sagittal planes. Two ViT configurations were tested: ViT 1 (1 head, 4 layers) and a Bayesian-optimized ViT 2 (4 heads, 8 layers). Features extracted from ViT embedding layers were reduced via principal component analysis to 2–16 dimensions and classified using the QOPC with reconfigurable beam splitter (RBS) gates. The proposed approach achieved unprecedented compression, up to 1,470 ×\times × × (from 10,290 to 7 parameters) while preserving over 99% of baseline accuracy. The approach reached 83.7% accuracy (ViT 2 , k=8k{=}8k=8 k = 8 , h=8h{=}8h=8 h = 8 ) with only 46 trainable parameters and achieved computational efficiency (CE) up to 92.0. Training was accelerated up to 28 ×\times × × (0.030 vs. 0.833 min) while maintaining robust diagnostic performance (F1: 0.77−0.82, receiver operating characteristic area under the curve (ROC-AUC): 0.87−0.90). Ablation studies confirmed that the quantum layer outperforms conventional MLPs by +3.4% accuracy with 35% fewer parameters, while late fusion of multi-view predictions further improved performance to 85.4% accuracy and 0.92 ROC-AUC. These results establish hybrid ViT-QOPC architectures as a practical and resource-efficient framework for medical image analysis, demonstrating their ability to dramatically reduce computational cost without compromising clinical accuracy.
Classical Vision Transformers (CViTs) have demonstrated strong performance in medical image analysis, supporting a wide range of digital health applications. However, their self-attention mechanisms can require substantial computational resources and model parameters. In parallel, quantum machine learning (QML) has attracted increasing interest in healthcare and other scientific domains, particularly because quantum-enhanced models may provide expressive representations for small datasets. In this paper, we propose MedQViT, a robust and parameter-efficient Quantum Vision Transformer for medical image classification. To reduce the computational cost of global self-attention, MedQViT combines a shared four-qubit parameterized quantum circuit with a quantum-feature state memory and trainable landmark tokens. This hybrid architecture encodes image patches into compact quantum-enhanced representations while using classical layers for feature aggregation and classification. Experiments on established medical image datasets evaluate the effectiveness and feasibility of MedQViT against classical and quantum baselines. MedQViT achieves competitive performance with substantially fewer parameters than conventional vision models and outperforms several classical and quantum methods in terms of test accuracy (ACC) and area under the receiver operating characteristic curve (AUC).
Skin cancer is the most common and fatal illness globally, and therefore, proper early detection is essential for successful treatment and enhanced patient outcomes. Classic deep learning models, especially Convolutional Neural Networks (CNNs), have greatly succeeded in medical image classification. However, classic CNNs also suffer from severe limitations such as computational inefficiency, overfitting on small datasets, and redundant feature extraction, which restrict their utility in clinical settings. To overcome these drawbacks, we introduce QAttn-CNN as a quantum–classical deep learning model combining a Quantum Attention Mechanism (QAttn) to improve feature selection and classification accuracy. Our method utilizes Quantum Convolutional Layers (QConv) and Quantum Image Representation (QIR) with Novel Enhanced Quantum Representation (NEQR) encoding to draw upon quantum parallelism and improve computational efficiency and complexity from O(N 2 ) to O(log N). The model is tested on three benchmark datasets: MNIST (70,000 grey-scale handwritten digit images), CIFAR-10 (60,000 RGB object images), and the Kaggle Skin Cancer: Malignant versus Benign dataset (3297 dermoscopic images: 1800 benign and 1497 malignant cases, from the International Skin Imaging Collaboration (ISIC) Archive). The dataset images were processed by converting them to grayscale, resizing them bilinearly to 150 × 150 pixels, and normalizing to [0–1] for quantum encoding. QAttn-CNN is contrasted with standard CNNs, QAttn-ViT (Quantum Attention Vision Transformer), and QAttn-ResNet18. Results indicate that QAttn-CNN attains state-of-the-art accuracy of 91% on the Skin Cancer dataset with a precision of 89%, a recall of 89%, and an F1-score of 91%, surpassing Baseline CNN (89% accuracy), QAttn-ViT (87%), and QAttn-ResNet18 (83%). On CIFAR-10, QAttn-CNN exhibits 10% accuracy enhancement over Baseline CNN with accuracy of 82% and 90% precision. On MNIST, QAttn-CNN performs at the peak of 99% accuracy, comparable to classical benchmarks but with greatly diminished computational overhead due to quantum parallelism. This study demonstrates the revolutionary potential of quantum-assisted deep learning in healthcare applications, especially for real-world binary medical image classification problems that identify malignant vs. benign skin lesions.
Lung cancer remains the leading cause of cancer-related mortality worldwide, underscoring the urgent need for accurate, efficient, and interpretable early detection methods. Existing benchmark large language models (LLMs) like ClinicalBERT and BioBERT, despite their advancements in biomedical text analysis, face critical limitations including high computational costs, limited interpretability, and reliance on extensive annotated datasets hindering their clinical integration. To address these challenges, we propose the Hybrid Attention Quantum Long Short-Term Memory-Attention (A-QLSTM-A) model, a novel quantum-classical framework that combines quantum variational circuits with LSTM networks and dual attention mechanisms. This design enhances feature extraction, improves interpretability, and offers a more efficient architectural pathway. Evaluated on MIMIC-III discharge summaries and MIMIC-IV chest radiography reports, A-QLSTM-A achieved 98.32% and 83.67% accuracy, respectively, surpassing existing models. This study establishes a new benchmark for scalable, interpretable AI in precision medicine, offering a promising tool for early lung cancer detection and clinical decision support.
Medical image classification is a critical component of modern healthcare; however, accurate diagnosis remains challenging due to limited annotated datasets, class imbalance, and the high dimensionality of medical imaging data. To address these challenges, a hybrid quantum-classical neural network (HQCNN) is proposed, integrating classical deep learning with variational quantum learning for medical image classification. The proposed architecture combines a five-layer convolutional neural network (CNN) for hierarchical feature extraction with a lightweight 4-qubit variational quantum circuit (VQC) incorporating quantum state encoding, superposition and entanglement mechanisms, and a quantum attention-Fourier (QAF) module. This hybrid design aims to improve nonlinear feature representation and quantum parameter efficiency while maintaining a shallow quantum circuit suitable for noisy intermediate-scale quantum (NISQ)-era constraints. Experimental evaluation on six MedMNIST benchmark datasets demonstrated competitive performance across both binary and multi-class classification tasks. HQCNN achieved 98.88% accuracy on the binary subset of PathMNIST (classes 0 vs. 1), 97.61% accuracy on the multi-class OrganAMNIST dataset, and 86.29% accuracy on BreastMNIST. Comparative experiments and statistical analyses demonstrated consistent improvements over the controlled BHQNN baseline, while component-wise ablation studies showed that the QAF module, superposition and entanglement mechanisms, and expressive parameterized rotations contributed to classification performance in a complementary and dataset-dependent manner. Moreover, HQCNN reduced the number of trainable quantum parameters by approximately 55.6% compared with the baseline hybrid quantum neural network (BHQNN). Noise-aware simulations further showed that the model retained relatively stable predictive performance under moderate depolarizing noise, supporting further evaluation under near-term quantum computing conditions. Overall, the results demonstrate that HQCNN provides a parameter-efficient hybrid quantum-classical framework for medical image classification and offers a promising foundation for further investigation of quantum-enhanced medical image analysis.