Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Mode-spectrum reconstruction from multicopy optical interference

Zixuan He

Published Oct 31, 2026• 0 citations
Publisher

Abstract

Can a measurement that records only one global vacuum event recover an optical mode spectrum? This article identifies when increasing the number of simultaneously interfering copies supplies exactly the spectral information lost by a two-copy test. It provides a finite algebraic reconstruction without first determining the generating mode basis. Source and measurement. Consider a pure source with known total photon number \(N\ge2\) and at most \(m\) occupied orthogonal modes: \[|\Psi\rangle=\sum_{j=1}^{m}\sqrt{w_j}e^{i\theta_j}|N_j\rangle,\qquad w_j\ge0,\qquad\sum_jw_j=1.\] Here \(|N_j\rangle\) has all photons in mode \(j\), and the target is the unordered spectrum \(\{w_j\}\) of the normalized one-particle reduced state. The source phases and a common passive mode basis may be unknown. This source class includes every pure two-photon state; for \(N\ge3\), the generalized NOON/GHZ form is an explicit preparation promise. Interfere \(\ell\) complete, independent, identically prepared copies in a Fourier multiport, acting identically on every physical signal mode. The probability that all relative output modes are vacuum is \[M_\ell=\ell^d\int Q_\Psi(z)^\ell\,d\mu_d(z),\qquad Q_\Psi(z)=|\langle z|\Psi\rangle|^2,\qquad d\mu_d=\pi^{-d}d^{2d}z,\] where \(d\) is the physical mode number. Spectator vacuum modes do not change this probability. Exact reconstruction and its mechanism. The probabilities \(M_2,\ldots,M_m\), together with normalization, determine every mode weight, including zero and repeated weights. The new connection is from these optical probabilities to spectral power sums. A formal logarithm separates connected photon pairings; their strictly positive coefficients make the map triangular and invertible at every order. Standard Newton identities then recover the spectrum. For generic positive, distinct weights, the lower prefix through \(M_{m-1}\) leaves even the largest weight undetermined. A concrete pair of three-photon sources has spectra \((1/2,1/2,0)\) and \((2/3,1/6,1/6)\). Both give \(M_2=11/64\), while their three-copy probabilities are \(155/6561\) and \(183/6561\). The reconstructed largest weight also determines the coherent peak and full trace-norm distance to a pure coherent state: \[q=\frac{N^Ne^{-N}}{N!}\max_jw_j,\qquad D_{\mathcal C}^{\,2}=4(1-q).\] Physical resource accounting. Highest interference order is distinct from total sample consumption. With \(n_\ell\) independent trials at order \(\ell\), the total number of input copies is \(C_{\rm in}=\sum_{\ell=2}^{m}\ell n_\ell\), and the incident photon count is \(NC_{\rm in}\). A finite two-hypothesis counting example is included. The exact inverse is not a uniform noisy-spectrum confidence theorem, and the order-necessity result concerns this specified vacuum-event hierarchy rather than arbitrary optical measurements. Mode-resolved one-particle measurements provide a different route to the spectrum. The integrated 13-page article contains two figure groups, complete proofs and references. It distinguishes the all-order optical-to-spectral connection from established replica-moment formulas and classical power-sum inversion.

DOI
10.5281/zenodo.23828768

Related papers

Brightness limits in quantum channel certification with coherent light

Zixuan He

How many uses of an optical device are needed to certify that it preserves quantum information? This article determines the optimal asymptotic number of coherent-light probes under an average photon budget. Matching upper and lower bounds show that a single optical mode carries an unavoidable logarithmic cost, while every fixed higher mode number follows a different power law. Certification task and resource accounting. The device is an arbitrary normal, memoryless bosonic quantum channel. The task distinguishes the identity from channels at least \(\varepsilon\) away in the energy-constrained diamond norm, defined using the full trace norm and a signal-energy budget \(E_s\). This guarantee includes inputs entangled with an unrestricted reference system. The physical probes are fresh coherent states with classically chosen amplitudes. Adaptive choices, retained quantum outputs and a final joint measurement are allowed. Every device call, including a vacuum pulse, is counted, and the actual illumination obeys \[\sum_{t=1}^{T}\mathbb E_{\mathcal K}\|\alpha_t\|^2\le T E_p\] under every channel in the testing promise. The probe budget \(E_p\) is distinct from the signal budget \(E_s\) defining the certification guarantee. Optimal mean-energy query laws. For fixed positive \(E_s,E_p\), fixed finite mode number \(m\), and both testing errors at most \(\delta\), the minimax number of calls satisfies \[T_{\mathrm{mean}}^{(1)}(\varepsilon,\delta)=\Theta_{E_s,E_p}\!\left(\varepsilon^{-4}\log\frac1\varepsilon\log\frac1\delta\right),\] \[T_{\mathrm{mean}}^{(m)}(\varepsilon,\delta)=\Theta_{m,E_s,E_p}\!\left(\varepsilon^{-(2m+2)}\log\frac1\delta\right),\qquad m\ge2.\] The bounds hold for sufficiently small \(\varepsilon\), uniformly over \(0<\delta\le1/4\). Independent probes drawn from a physical positive multiscale source, followed by individual binary target tests, attain these orders. The matching converse covers adaptive coherent-probe protocols with quantum output memory. Thus those additional processing capabilities do not improve the asymptotic order within the stated preparation model. The result specifies matching scaling laws, rather than exact finite-query counts or optimal numerical constants. Why one mode has an extra logarithm. Rare high-photon coherences can strongly affect an energy-bounded quantum input while leaving only a weak signature on coherent probes. The proof retains this interference through a positive coherent-frame Green kernel. Its spectral sum grows as \(t\log t\) for one mode and as \(t^m\) for fixed \(m\ge2\). A complementary family of physical channels shows that the single-mode logarithm is necessary, rather than an artifact of the reconstruction bound. What source brightness changes. The optimal mean-only laws contrast with prescribed independent Gaussian modulation, for which \(\log T_{\mathrm G}=\Theta(\varepsilon^{-2})\) at fixed confidence. A fixed brightness cap gives \(\log T_{\mathrm{cap}}=\Theta(\varepsilon^{-2}\log(1/\varepsilon))\). The article also establishes matching logarithmic orders under stretched-exponential brightness constraints and develops the conversion from average coherent-probe error to thermal Choi-state and energy-constrained worst-input guarantees. These are worst-case certification limits for the specified coherent-probe access model. The channel class retains infinite photon tails and imposes no output-energy bound. This updated, integrated 37-page article contains the main results, two figure groups, complete proofs and references.

•Oct 25, 2026•0 citations

Mode reconstruction by multi-photon statistics

Elizabeth A. Goldschmidt, Sergey V. Polyakov, Alan L. Migdall +7 more

Knowing the mode structure of light aids in minimizing loss and decoherence of quantum information. We present and experimentally implement reconstruction of the mode distributions of classical and non-classical light using measured photon number distributions.

Conference on Lasers and Electro-Optics•Jan 1, 2013•0 citations

Optimal Passive Masks for Thermal Source Reconstruction

K. Fathi

How much detected thermal light is needed to identify several emitting sites? This working paper studies binary sources on a known grid of addressable source-image modes, using one fixed passive optical mask, photon counting, and a predetermined observation length. It distinguishes the original one-reference apparatus, complete Fourier reference collection, and a separate apparatus with one added vacuum input. All recorded photons count toward the measurement cost. The central result establishes the optimal quadratic detected-photon order at unit brightness for every fixed support limit on every grid, without geometric restrictions or primality assumptions. A reciprocal transmission mask attains this order using target counts alone, while recorded reference photons remain included in the cost. The proof reconstructs short cyclic arcs from two rational-probe values, then uses contour integration to isolate entire clusters of poles. This gives uniform quantitative separation without requiring a fixed minimum distance between individual poles. A bounded candidate list removes the grid-size logarithm from the final comparisons. On prime grids, a shorter finite-field argument recovers the support from two integer edge profiles. The quadratic law also holds uniformly over every nonempty reference subset when known brightness remains in a fixed interval bounded away from zero. The contour argument extends to a general stability theorem for rational interaction observables: under explicit locality and conditioning assumptions, quantitative distinguishability within clusters yields quantitative separation of the global polynomial data. For irregular registered dictionaries, this gives a separation margin proportional to the minimum site spacing, with an optimal spacing exponent. This extension assumes exactly resolved distance channels; their optical acquisition and robustness to unknown position errors require further analysis. Explicit dependence on the support limit also yields a growing-support regime: the photon cost remains \(n^{2+o(1)}\log(1/\delta)\) whenever \(s^{2}\log(2s)=o(\log n)\). The accompanying computational bound is stated in real arithmetic, and the dependence on sparsity is deliberately conservative. The manuscript retains explicit ramp-mask constructions for every configuration of at most four emitters, for short-span sources, and for sources with distinct cyclic pair distances. The last class has no span restriction and contains an asymptotically overwhelming fraction of fixed-size supports. For four emitters, ordinary-correlation rigidity and cyclic separation together distinguish reflected configurations. An explicit passive mask also attains the exact optimal Fourier-intensity separation under a prescribed transmission floor. In both the original and complete-reference experiments, sufficiently faint light produces a different law: at fixed sparsity, the optimal photon order grows as the grid size raised to twice the support limit. For at most two emitters, the paper determines the optimal detected-photon order throughout the known-brightness range, from arbitrarily faint light through unit brightness, on odd grids in the original apparatus and on every grid with complete reference collection. The result includes the dependence on grid size, brightness, and error probability, including an additional logarithmic information cost between the faint and bright limits. At fixed confidence, the quadratic regime begins at brightness of order \((\log n)/n^{2}\). A mask combining an index ramp with a quadratic-residue code attains the sharp order. On even physical grids, one known vacuum input and odd-dimensional Fourier optics give the same law; omitting one target output preserves the detector count. This is a distinct apparatus. For the specified two-scale transmissions on an infinite even-grid family, an exact lower bound using the complete count record proves that changing phases or decoders alone cannot remove their intermediate-brightness limitation. A collected-light model makes the physical scope explicit. For a known collection operator, binary-source identifiability is equivalent to injectivity of the induced thermal covariance map. Covariance collisions give identical quantum states and therefore prevent discrimination by any subsequent receiver. A passive multiport establishes population identifiability when the map is injective. The paper also derives the exact throughput for uniform passive mode separation from the smallest Gram eigenvalue and accounts separately for detected and incident photons. These results connect the assumed mode access to a specified collection model; they do not establish a general quantum-optimal receiver or a complete astronomical implementation. Reference excess variance supplies a normalization that identifies the spatial source despite an unknown finite common-profile thermal-mode spectrum and independent unknown Poisson backgrounds. The finite-sampling guarantee includes the empty source under explicit mean and nonzero-signal bounds. Population identifiability of the mode spectrum is distinguished from stable estimation. When background means are known, the arm means recover source mass and improve a guaranteed scale-free precision radius. Further results include exact thermal count variances, confidence exponents, calibration bounds, a photon penalty for discarding detector labels, and an exact target-only localization obstruction when singleton brightness is unrestricted and unknown. The results have analytical proofs, supported by 34 reproducible finite and symbolic verification suites. These checks provide corroboration, not experimental validation or external peer review. The unrestricted fixed-sparsity unit-brightness problem is resolved on all grids. Remaining questions include the optimized even-grid intermediate-brightness transition in the original apparatus, transitions for three or more emitters, sharp growing-support rates, sharp reference-coverage dependence at vanishing brightness, and optimal covariance-only scale-free precision. Continuous off-grid recovery requires a tolerance-based criterion and additional stability analysis. The work makes no literature-priority claim.

•Oct 27, 2026•0 citations

Quantum noise revisited: complete measurement of spectral field modes

Alessandro S. Villar, A. S. Coelho, F. A. S. Barbosa +3 more

We show that quantum noise in the spectral domain usually corresponds to a mixed quantum measurement, and cannot attain complete information about the quantum state of spectral modes [PRL 111, 200402 (2013).]

Latin America Optics and Photonics Conference•Jan 1, 2014•0 citations

Distinct stability laws for Wigner entropy and non-Gaussian structure

Zixuan He

Loss can restore the vacuum entropy bound without erasing non-Gaussian structure. This paper determines when an entropy statement justifies a coherent-state approximation, when non-Gaussian structure survives optical loss, and what mode and source-request budgets are needed to use that structure. The results give quantum-optics researchers separate criteria for entropy recovery, state approximation, Gaussian concentration and conversion to a specified output. Version 1.5 — revised 10 October 2026. The 96-page PDF contains the main article, Methods, Supplementary Information and references. This revision connects the exact loss boundary to a mode-uniform near-equality certificate, finite-data validation, a conversion-cost lower bound for the same thermally repaired source, and an exact equal-entropy comparison of sources with different conversion-cost exponents. The central figures are updated accordingly. 1. Near-vacuum states can have an unbounded entropy deficit Write $\nu_m$ for the $m$-mode vacuum and define $\Delta_{\alpha,m}(\rho)=H_\alpha(W_{\nu_m})-H_\alpha(W_\rho)$, using natural logarithms; $H_1$ is Shannon entropy. Positive deficit means entropy below vacuum. We construct physical Wigner-positive states satisfying, simultaneously, $$E_m=\operatorname{Tr}(N_m\rho_m)\to0,\qquad \tfrac12\|\rho_m-\nu_m\|_1\to0,\qquad d_{\mathcal F_m}(\rho_m)\to0,\qquad \Delta_{1,m}(\rho_m)\to+\infty.$$ Here $\mathcal F_m$ is the trace-norm-closed convex hull of Gaussian states and $d_{\mathcal F_m}$ uses half the trace norm. Thus proximity to the entire Gaussian model does not control Wigner entropy uniformly in mode number. Independent weak modes amplify a one-mode entropy effect while their total excitation vanishes. For the same sequence, half loss instead gives $-E_m\le\Delta_{1,m}(\mathcal L_{1/2}^{\otimes m}\rho_m)\le0$, so the entropy difference from vacuum tends to zero. 2. The exact pure-loss recovery boundary For Wigner-positive inputs, intensity transmissivity $\eta$ and any fixed positive total input-energy budget $E$, the sharp threshold is $$\eta_c(\alpha)=\begin{cases}1/2,&0<\alpha\le1,\\ \alpha/2,&1<\alpha<2.\end{cases}$$ With $\mathcal P_{m,E}=\{\rho:W_\rho\ge0,\ \operatorname{Tr}(N_m\rho)\le E\}$, $$\sup_{m\ge1}\sup_{\rho\in\mathcal P_{m,E}}\Delta_{\alpha,m}(\mathcal L_\eta^{\otimes m}\rho)=\begin{cases}0,&\eta\le\eta_c(\alpha),\\+\infty,&\eta>\eta_c(\alpha).\end{cases}$$ The recovery statement includes the boundary itself and is independent of mode number. Half loss also restores vacuum majorization for arbitrary density operators. For $\alpha\ge2$, established Wigner-norm bounds give the vacuum entropy bound at every transmissivity for Wigner-positive outputs. These statements distinguish a universal guarantee from the earlier sign crossing that a particular source may exhibit. 3. Near equality gives a certificate for the entire input For an arbitrary input $\rho$, define the half-loss output Shannon excess $$s(\rho)=h(W_{\mathcal L_{1/2}^{\otimes m}\rho})-m(1+\ln\pi)\ge0.$$ The half-loss identity identifies this quantity with the input's total Wehrl entropy excess. Applying mode-uniform Wehrl stability yields $$\inf_a\|\rho-|a\rangle\langle a|\|_1^2\le\frac{64}{\ln2}\,s(\rho).$$ The bound controls the full input state, with no energy or photon-support restriction. One coherent reference then controls every subsequent quantum channel and every unconditional measurement event. In particular, an event-probability error at most $\epsilon$ is guaranteed by $s\le(\ln2)\epsilon^2/16$. Conversely, a surviving output Gaussian-hull gap enforces $$s(\rho)\ge\frac{\ln2}{16}\,d_{\mathcal F_m}(\mathcal L_{1/2}^{\otimes m}\rho)^2.$$ Recovery of the inequality and proximity to equality therefore support different physical inferences: the former permits residual non-Gaussian structure, while the latter certifies a coherent-state approximation. 4. Surviving structure has mode and conversion costs A thermally repaired vacuum–three-photon source with per-mode occupation $c/m$ has total input energy tending to $3c$. Along the recovery boundary, its attenuated state obeys $$\liminf_{m\to\infty}d_{\mathcal F_m}(\widetilde\rho_{m,\eta_c})\ge c\eta_c^3\exp\{-c[1-(1-\eta_c)^3]\}>0.$$ At half transmission this lower bound is $g(c)=(c/8)e^{-7c/8}$. Starting from one complete block, Gaussian processing requires $\Theta(m)$ output modes to retain any fixed positive gap below this bound at success probability at least a fixed $p_0>0$. Gaussian ancillary states, adaptive Gaussian measurements, feedback, discarding and postselection are included. A distinct task requests fresh independent blocks of this same half-loss source to produce the one-mode target $\tau_*=(18|0\rangle\langle0|+6|1\rangle\langle1|+|2\rangle\langle2|)/25$ within half trace distance $10^{-6}$. Let $C_m$ be the infimum of expected complete-block requests divided by success probability, including all failed requests. For fixed $0<c\le1$, every achieving Gaussian protocol obeys the asymptotic lower bound $$\log C_m\ge\frac1{128}(m/c)^{1/3}-\log m-O(1).$$ This is a source-request lower bound; the optimal achievable cost for this source remains undetermined. The proof evaluates a curvature-controlled input certificate for the actual thermally repaired state and applies the Gaussian conversion theorem of the companion paper cited below. 5. Exactly equal entropy does not fix conversion cost For two separate two-mode quartic source families, their mixture probabilities can be adjusted so that their half-loss Shannon entropies are exactly equal. Under a common target, tolerance and failure-inclusive accounting, the inherited matching conversion laws become $$h(W_{\omega_A})=h(W_{\omega_B})=2(1+\ln\pi)+s,\qquad \log C_A(s)=\Theta(s^{-1/3}),\qquad \log C_B(s)=\Theta(s^{-1/2}).$$ The target tolerance is held fixed in these asymptotics. The delivered energies after entropy matching satisfy $E_A,E_B\sim s/2$. At exactly equal energy, the two excesses instead share $s_i(E)=2E-(35/8)E^2+O(E^3)$ and differ by $s_A(E)-s_B(E)=15E^3+O(E^4)$. Entropy alone therefore cannot select the cheaper source for a fixed output task. 6. Finite data and finite mode budgets Under a declared displaced-input photon-tail bound $\operatorname{Tr}[N\mathbf1_{N>K}\sigma_a]\le\tau_K$, trusted half loss and all-mode on/off detection with efficiency at least $\xi_{\min}$, the click probability $q$ gives $$s(\sigma)\le A_Kq+\tau_K,\qquad A_K=\frac{K}{1-(1-\xi_{\min}/2)^K}.$$ A one-sided binomial bound turns this into an entropy confidence certificate. An explicit undisplaced four-photon-cutoff example uses $K=4$, $\tau_K=0$, $\xi=0.8$ and $N=3{,}517{,}336$ independent validation blocks, accepting at most 41 clicks, to certify unconditional event error at most $0.05$ with false-acceptance probability at most $0.001$ and missed acceptance at most $0.001$ on the stated low-click alternative class. All vacuum results count; training, calibration and source heralding are separate costs. When coherent-state approximation alone is the task, the same click measurement supplies a stronger direct fidelity test. The paper also gives all-input finite-budget exclusions above the loss-recovery line. For example, at $E=1$, $\alpha=1.9$, $\eta=0.9505$ and $m=10^5$, the certified bound $\Delta_\alpha<0.06942$ rules out a target deficit of $0.1$ nat. A separate finite single-mode preparation model predicts positive Shannon deficit near $\eta=0.97$, negative deficit near $\eta=0.85$, and a Gaussian-hull witness above $4.4\times10^{-3}$ at half transmission, with explicit preparation, measurement-error and raw-trial budgets in the PDF. 7. Dimensional scales, a strict entropy floor and ORCS Near order two, put $\alpha=2-\delta$ and $L=\ln(1/\delta)$. For the maximum deficit $D_{m,E}$ at fixed total energy, $$D_{m,E}(2-\delta)=\Theta_{m,E}(\delta/L)\quad\text{for fixed }m,\qquad T_h(\delta,E)=\Theta_{E,h}(L/\delta),$$ where $T_h$ is the first mode number allowing a fixed positive deficit $h$. Beyond a sufficiently large fixed multiple of $L/\delta$, $D_{m,E}(2-\delta)=\Theta_E(m\delta)$. The manuscript separates proved sufficient fronts from necessary exit bounds; the sharp first-crossing coefficient remains open. At every fixed mode number, an energy-unrestricted strict Shannon floor also holds: $h(W_\rho)\ge m\ln(2\pi)+\varepsilon_m$ with $\varepsilon_m>0$ for all Wigner-positive states. The ordering-resolved coherence spectrum (ORCS) supplies an exact single-mode loss coordinate. With $\mathcal C_{r,k}$ denoting the ordering-weighted norm of photon-number-difference block $k$, $$\mathcal C_{r,k}(\mathcal L_\eta\rho)=\mathcal C_{T_\eta(r),k}(\rho),\qquad T_\eta(r)=1-\frac{1-r}{\eta}.$$ For vacuum–$n$-photon coherence and $1<\alpha<2$, $$\mathcal C_{1-\alpha/2}(\mathcal L_\eta|n\rangle\langle0|)=\left(\frac{2\eta}{\alpha}\right)^n.$$ This formula exposes the high-order coherence mechanism at the loss threshold; the universal recovery result is proved through the full nonlinear Wigner-norm inequality. Related papers and history The counterexample paper Wigner entropy below vacuum: physical counterexamples and stability limits expands arXiv:2609.13312v1, submitted on 10 September 2026. This stability paper develops the dimensional, loss-dependent and operational consequences. Its state-approximation and conversion interfaces use the companion results From phase-space entropy to coherent-state error: mode-uniform Rényi–Wehrl stability and Phase records control the conversion cost of non-Gaussian light. The mode-retention comparison connects to Limits to Gaussian concentration of non-Gaussian light.

•Sep 23, 2026•0 citations

Measurement of Incompatible Observables via the Cloning of Quantum States

Rebecca Y. Saaltink, Lambert Giner, Jeff S. Lundeen

We experimentally measure a complementary pair of observables, one on each of two optimally cloned photons. Just as in a classical version of this procedure, the results give the original state of the photon.

Frontiers in Optics•Jan 1, 2016•0 citations
Can a measurement that records only one global vacuum event recover an optical mode spectrum? This article identifies when increasing the number of simultaneously interfering copies supplies exactly the spectral information lost by a two-copy test. It provides a finite algebraic reconstruction without first determining the generating mode basis. Source and measurement. Consider a pure source with known total photon number (N\ge2) and at most (m) occupied orthogonal modes: [|\Psi\rangle=\sum_{j=1}^{m}\sqrt{w_j}e^{i\theta_j}|N_j\rangle,\qquad w_j\ge0,\qquad\sum_jw_j=1.] Here (|N_j\rangle) has all photons in mode (j), and the target is the unordered spectrum ({w_j}) of the normalized one-particle reduced state. The source phases and a common passive mode basis may be unknown. This source class includes every pure two-photon state; for (N\ge3), the generalized NOON/GHZ form is an explicit preparation promise. Interfere (\ell) complete, independent, identically prepared copies in a Fourier multiport, acting identically on every physical signal mode. The probability that all relative output modes are vacuum is [M_\ell=\ell^d\int Q_\Psi(z)^\ell,d\mu_d(z),\qquad Q_\Psi(z)=|\langle z|\Psi\rangle|^2,\qquad d\mu_d=\pi^{-d}d^{2d}z,] where (d) is the physical mode number. Spectator vacuum modes do not change this probability. Exact reconstruction and its mechanism. The probabilities (M_2,\ldots,M_m), together with normalization, determine every mode weight, including zero and repeated weights. The new connection is from these optical probabilities to spectral power sums. A formal logarithm separates connected photon pairings; their strictly positive coefficients make the map triangular and invertible at every order. Standard Newton identities then recover the spectrum. For generic positive, distinct weights, the lower prefix through (M_{m-1}) leaves even the largest weight undetermined. A concrete pair of three-photon sources has spectra ((1/2,1/2,0)) and ((2/3,1/6,1/6)). Both give (M_2=11/64), while their three-copy probabilities are (155/6561) and (183/6561). The reconstructed largest weight also determines the coherent peak and full trace-norm distance to a pure coherent state: [q=\frac{N^Ne^{-N}}{N!}\max_jw_j,\qquad D_{\mathcal C}^{,2}=4(1-q).] Physical resource accounting. Highest interference order is distinct from total sample consumption. With (n_\ell) independent trials at order (\ell), the total number of input copies is (C_{\rm in}=\sum_{\ell=2}^{m}\ell n_\ell), and the incident photon count is (NC_{\rm in}). A finite two-hypothesis counting example is included. The exact inverse is not a uniform noisy-spectrum confidence theorem, and the order-necessity result concerns this specified vacuum-event hierarchy rather than arbitrary optical measurements. Mode-resolved one-particle measurements provide a different route to the spectrum. The integrated 13-page article contains two figure groups, complete proofs and references. It distinguishes the all-order optical-to-spectral connection from established replica-moment formulas and classical power-sum inversion.
How many uses of an optical device are needed to certify that it preserves quantum information? This article determines the optimal asymptotic number of coherent-light probes under an average photon budget. Matching upper and lower bounds show that a single optical mode carries an unavoidable logarithmic cost, while every fixed higher mode number follows a different power law. Certification task and resource accounting. The device is an arbitrary normal, memoryless bosonic quantum channel. The task distinguishes the identity from channels at least ε\varepsilonε away in the energy-constrained diamond norm, defined using the full trace norm and a signal-energy budget EsE_sEs​. This guarantee includes inputs entangled with an unrestricted reference system. The physical probes are fresh coherent states with classically chosen amplitudes. Adaptive choices, retained quantum outputs and a final joint measurement are allowed. Every device call, including a vacuum pulse, is counted, and the actual illumination obeys ∑t=1TEK∥αt∥2≤TEp\sum_{t=1}^{T}\mathbb E_{\mathcal K}\|\alpha_t\|^2\le T E_p∑t=1T​EK​∥αt​∥2≤TEp​ under every channel in the testing promise. The probe budget EpE_pEp​ is distinct from the signal budget EsE_sEs​ defining the certification guarantee. Optimal mean-energy query laws. For fixed positive Es,EpE_s,E_pEs​,Ep​, fixed finite mode number mmm, and both testing errors at most δ\deltaδ, the minimax number of calls satisfies Tmean(1)(ε,δ)=ΘEs,Ep ⁣(ε−4log⁡1εlog⁡1δ),T_{\mathrm{mean}}^{(1)}(\varepsilon,\delta)=\Theta_{E_s,E_p}\!\left(\varepsilon^{-4}\log\frac1\varepsilon\log\frac1\delta\right),Tmean(1)​(ε,δ)=ΘEs​,Ep​​(ε−4logε1​logδ1​), Tmean(m)(ε,δ)=Θm,Es,Ep ⁣(ε−(2m+2)log⁡1δ),m≥2.T_{\mathrm{mean}}^{(m)}(\varepsilon,\delta)=\Theta_{m,E_s,E_p}\!\left(\varepsilon^{-(2m+2)}\log\frac1\delta\right),\qquad m\ge2.Tmean(m)​(ε,δ)=Θm,Es​,Ep​​(ε−(2m+2)logδ1​),m≥2. The bounds hold for sufficiently small ε\varepsilonε, uniformly over 0<δ≤1/40<\delta\le1/40<δ≤1/4. Independent probes drawn from a physical positive multiscale source, followed by individual binary target tests, attain these orders. The matching converse covers adaptive coherent-probe protocols with quantum output memory. Thus those additional processing capabilities do not improve the asymptotic order within the stated preparation model. The result specifies matching scaling laws, rather than exact finite-query counts or optimal numerical constants. Why one mode has an extra logarithm. Rare high-photon coherences can strongly affect an energy-bounded quantum input while leaving only a weak signature on coherent probes. The proof retains this interference through a positive coherent-frame Green kernel. Its spectral sum grows as tlog⁡tt\log ttlogt for one mode and as tmt^mtm for fixed m≥2m\ge2m≥2. A complementary family of physical channels shows that the single-mode logarithm is necessary, rather than an artifact of the reconstruction bound. What source brightness changes. The optimal mean-only laws contrast with prescribed independent Gaussian modulation, for which log⁡TG=Θ(ε−2)\log T_{\mathrm G}=\Theta(\varepsilon^{-2})logTG​=Θ(ε−2) at fixed confidence. A fixed brightness cap gives log⁡Tcap=Θ(ε−2log⁡(1/ε))\log T_{\mathrm{cap}}=\Theta(\varepsilon^{-2}\log(1/\varepsilon))logTcap​=Θ(ε−2log(1/ε)). The article also establishes matching logarithmic orders under stretched-exponential brightness constraints and develops the conversion from average coherent-probe error to thermal Choi-state and energy-constrained worst-input guarantees. These are worst-case certification limits for the specified coherent-probe access model. The channel class retains infinite photon tails and imposes no output-energy bound. This updated, integrated 37-page article contains the main results, two figure groups, complete proofs and references.
How much detected thermal light is needed to identify several emitting sites? This working paper studies binary sources on a known grid of addressable source-image modes, using one fixed passive optical mask, photon counting, and a predetermined observation length. It distinguishes the original one-reference apparatus, complete Fourier reference collection, and a separate apparatus with one added vacuum input. All recorded photons count toward the measurement cost. The central result establishes the optimal quadratic detected-photon order at unit brightness for every fixed support limit on every grid, without geometric restrictions or primality assumptions. A reciprocal transmission mask attains this order using target counts alone, while recorded reference photons remain included in the cost. The proof reconstructs short cyclic arcs from two rational-probe values, then uses contour integration to isolate entire clusters of poles. This gives uniform quantitative separation without requiring a fixed minimum distance between individual poles. A bounded candidate list removes the grid-size logarithm from the final comparisons. On prime grids, a shorter finite-field argument recovers the support from two integer edge profiles. The quadratic law also holds uniformly over every nonempty reference subset when known brightness remains in a fixed interval bounded away from zero. The contour argument extends to a general stability theorem for rational interaction observables: under explicit locality and conditioning assumptions, quantitative distinguishability within clusters yields quantitative separation of the global polynomial data. For irregular registered dictionaries, this gives a separation margin proportional to the minimum site spacing, with an optimal spacing exponent. This extension assumes exactly resolved distance channels; their optical acquisition and robustness to unknown position errors require further analysis. Explicit dependence on the support limit also yields a growing-support regime: the photon cost remains n2+o(1)log⁡(1/δ)n^{2+o(1)}\log(1/\delta)n2+o(1)log(1/δ) whenever s2log⁡(2s)=o(log⁡n)s^{2}\log(2s)=o(\log n)s2log(2s)=o(logn). The accompanying computational bound is stated in real arithmetic, and the dependence on sparsity is deliberately conservative. The manuscript retains explicit ramp-mask constructions for every configuration of at most four emitters, for short-span sources, and for sources with distinct cyclic pair distances. The last class has no span restriction and contains an asymptotically overwhelming fraction of fixed-size supports. For four emitters, ordinary-correlation rigidity and cyclic separation together distinguish reflected configurations. An explicit passive mask also attains the exact optimal Fourier-intensity separation under a prescribed transmission floor. In both the original and complete-reference experiments, sufficiently faint light produces a different law: at fixed sparsity, the optimal photon order grows as the grid size raised to twice the support limit. For at most two emitters, the paper determines the optimal detected-photon order throughout the known-brightness range, from arbitrarily faint light through unit brightness, on odd grids in the original apparatus and on every grid with complete reference collection. The result includes the dependence on grid size, brightness, and error probability, including an additional logarithmic information cost between the faint and bright limits. At fixed confidence, the quadratic regime begins at brightness of order (log⁡n)/n2(\log n)/n^{2}(logn)/n2. A mask combining an index ramp with a quadratic-residue code attains the sharp order. On even physical grids, one known vacuum input and odd-dimensional Fourier optics give the same law; omitting one target output preserves the detector count. This is a distinct apparatus. For the specified two-scale transmissions on an infinite even-grid family, an exact lower bound using the complete count record proves that changing phases or decoders alone cannot remove their intermediate-brightness limitation. A collected-light model makes the physical scope explicit. For a known collection operator, binary-source identifiability is equivalent to injectivity of the induced thermal covariance map. Covariance collisions give identical quantum states and therefore prevent discrimination by any subsequent receiver. A passive multiport establishes population identifiability when the map is injective. The paper also derives the exact throughput for uniform passive mode separation from the smallest Gram eigenvalue and accounts separately for detected and incident photons. These results connect the assumed mode access to a specified collection model; they do not establish a general quantum-optimal receiver or a complete astronomical implementation. Reference excess variance supplies a normalization that identifies the spatial source despite an unknown finite common-profile thermal-mode spectrum and independent unknown Poisson backgrounds. The finite-sampling guarantee includes the empty source under explicit mean and nonzero-signal bounds. Population identifiability of the mode spectrum is distinguished from stable estimation. When background means are known, the arm means recover source mass and improve a guaranteed scale-free precision radius. Further results include exact thermal count variances, confidence exponents, calibration bounds, a photon penalty for discarding detector labels, and an exact target-only localization obstruction when singleton brightness is unrestricted and unknown. The results have analytical proofs, supported by 34 reproducible finite and symbolic verification suites. These checks provide corroboration, not experimental validation or external peer review. The unrestricted fixed-sparsity unit-brightness problem is resolved on all grids. Remaining questions include the optimized even-grid intermediate-brightness transition in the original apparatus, transitions for three or more emitters, sharp growing-support rates, sharp reference-coverage dependence at vanishing brightness, and optimal covariance-only scale-free precision. Continuous off-grid recovery requires a tolerance-based criterion and additional stability analysis. The work makes no literature-priority claim.
Loss can restore the vacuum entropy bound without erasing non-Gaussian structure. This paper determines when an entropy statement justifies a coherent-state approximation, when non-Gaussian structure survives optical loss, and what mode and source-request budgets are needed to use that structure. The results give quantum-optics researchers separate criteria for entropy recovery, state approximation, Gaussian concentration and conversion to a specified output. Version 1.5 — revised 10 October 2026. The 96-page PDF contains the main article, Methods, Supplementary Information and references. This revision connects the exact loss boundary to a mode-uniform near-equality certificate, finite-data validation, a conversion-cost lower bound for the same thermally repaired source, and an exact equal-entropy comparison of sources with different conversion-cost exponents. The central figures are updated accordingly. 1. Near-vacuum states can have an unbounded entropy deficit Write νm\nu_mνm​ for the mmm-mode vacuum and define Δα,m(ρ)=Hα(Wνm)−Hα(Wρ)\Delta_{\alpha,m}(\rho)=H_\alpha(W_{\nu_m})-H_\alpha(W_\rho)Δα,m​(ρ)=Hα​(Wνm​​)−Hα​(Wρ​), using natural logarithms; H1H_1H1​ is Shannon entropy. Positive deficit means entropy below vacuum. We construct physical Wigner-positive states satisfying, simultaneously, Em=Tr⁡(Nmρm)→0,12∥ρm−νm∥1→0,dFm(ρm)→0,Δ1,m(ρm)→+∞.E_m=\operatorname{Tr}(N_m\rho_m)\to0,\qquad \tfrac12\|\rho_m-\nu_m\|_1\to0,\qquad d_{\mathcal F_m}(\rho_m)\to0,\qquad \Delta_{1,m}(\rho_m)\to+\infty.Em​=Tr(Nm​ρm​)→0,21​∥ρm​−νm​∥1​→0,dFm​​(ρm​)→0,Δ1,m​(ρm​)→+∞. Here Fm\mathcal F_mFm​ is the trace-norm-closed convex hull of Gaussian states and dFmd_{\mathcal F_m}dFm​​ uses half the trace norm. Thus proximity to the entire Gaussian model does not control Wigner entropy uniformly in mode number. Independent weak modes amplify a one-mode entropy effect while their total excitation vanishes. For the same sequence, half loss instead gives −Em≤Δ1,m(L1/2⊗mρm)≤0-E_m\le\Delta_{1,m}(\mathcal L_{1/2}^{\otimes m}\rho_m)\le0−Em​≤Δ1,m​(L1/2⊗m​ρm​)≤0, so the entropy difference from vacuum tends to zero. 2. The exact pure-loss recovery boundary For Wigner-positive inputs, intensity transmissivity η\etaη and any fixed positive total input-energy budget EEE, the sharp threshold is ηc(α)={1/2,0<α≤1,α/2,1<α<2.\eta_c(\alpha)=\begin{cases}1/2,&0<\alpha\le1,\\ \alpha/2,&1<\alpha<2.\end{cases}ηc​(α)={1/2,α/2,​0<α≤1,1<α<2.​ With Pm,E={ρ:Wρ≥0, Tr⁡(Nmρ)≤E}\mathcal P_{m,E}=\{\rho:W_\rho\ge0,\ \operatorname{Tr}(N_m\rho)\le E\}Pm,E​={ρ:Wρ​≥0, Tr(Nm​ρ)≤E}, sup⁡m≥1sup⁡ρ∈Pm,EΔα,m(Lη⊗mρ)={0,η≤ηc(α),+∞,η>ηc(α).\sup_{m\ge1}\sup_{\rho\in\mathcal P_{m,E}}\Delta_{\alpha,m}(\mathcal L_\eta^{\otimes m}\rho)=\begin{cases}0,&\eta\le\eta_c(\alpha),\\+\infty,&\eta>\eta_c(\alpha).\end{cases}supm≥1​supρ∈Pm,E​​Δα,m​(Lη⊗m​ρ)={0,+∞,​η≤ηc​(α),η>ηc​(α).​ The recovery statement includes the boundary itself and is independent of mode number. Half loss also restores vacuum majorization for arbitrary density operators. For α≥2\alpha\ge2α≥2, established Wigner-norm bounds give the vacuum entropy bound at every transmissivity for Wigner-positive outputs. These statements distinguish a universal guarantee from the earlier sign crossing that a particular source may exhibit. 3. Near equality gives a certificate for the entire input For an arbitrary input ρ\rhoρ, define the half-loss output Shannon excess s(ρ)=h(WL1/2⊗mρ)−m(1+ln⁡π)≥0.s(\rho)=h(W_{\mathcal L_{1/2}^{\otimes m}\rho})-m(1+\ln\pi)\ge0.s(ρ)=h(WL1/2⊗m​ρ​)−m(1+lnπ)≥0. The half-loss identity identifies this quantity with the input's total Wehrl entropy excess. Applying mode-uniform Wehrl stability yields inf⁡a∥ρ−∣a⟩⟨a∣∥12≤64ln⁡2 s(ρ).\inf_a\|\rho-|a\rangle\langle a|\|_1^2\le\frac{64}{\ln2}\,s(\rho).infa​∥ρ−∣a⟩⟨a∣∥12​≤ln264​s(ρ). The bound controls the full input state, with no energy or photon-support restriction. One coherent reference then controls every subsequent quantum channel and every unconditional measurement event. In particular, an event-probability error at most ϵ\epsilonϵ is guaranteed by s≤(ln⁡2)ϵ2/16s\le(\ln2)\epsilon^2/16s≤(ln2)ϵ2/16. Conversely, a surviving output Gaussian-hull gap enforces s(ρ)≥ln⁡216 dFm(L1/2⊗mρ)2.s(\rho)\ge\frac{\ln2}{16}\,d_{\mathcal F_m}(\mathcal L_{1/2}^{\otimes m}\rho)^2.s(ρ)≥16ln2​dFm​​(L1/2⊗m​ρ)2. Recovery of the inequality and proximity to equality therefore support different physical inferences: the former permits residual non-Gaussian structure, while the latter certifies a coherent-state approximation. 4. Surviving structure has mode and conversion costs A thermally repaired vacuum–three-photon source with per-mode occupation c/mc/mc/m has total input energy tending to 3c3c3c. Along the recovery boundary, its attenuated state obeys lim inf⁡m→∞dFm(ρ~m,ηc)≥cηc3exp⁡{−c[1−(1−ηc)3]}>0.\liminf_{m\to\infty}d_{\mathcal F_m}(\widetilde\rho_{m,\eta_c})\ge c\eta_c^3\exp\{-c[1-(1-\eta_c)^3]\}>0.liminfm→∞​dFm​​(ρ​m,ηc​​)≥cηc3​exp{−c[1−(1−ηc​)3]}>0. At half transmission this lower bound is g(c)=(c/8)e−7c/8g(c)=(c/8)e^{-7c/8}g(c)=(c/8)e−7c/8. Starting from one complete block, Gaussian processing requires Θ(m)\Theta(m)Θ(m) output modes to retain any fixed positive gap below this bound at success probability at least a fixed p0>0p_0>0p0​>0. Gaussian ancillary states, adaptive Gaussian measurements, feedback, discarding and postselection are included. A distinct task requests fresh independent blocks of this same half-loss source to produce the one-mode target τ∗=(18∣0⟩⟨0∣+6∣1⟩⟨1∣+∣2⟩⟨2∣)/25\tau_*=(18|0\rangle\langle0|+6|1\rangle\langle1|+|2\rangle\langle2|)/25τ∗​=(18∣0⟩⟨0∣+6∣1⟩⟨1∣+∣2⟩⟨2∣)/25 within half trace distance 10−610^{-6}10−6. Let CmC_mCm​ be the infimum of expected complete-block requests divided by success probability, including all failed requests. For fixed 0<c≤10<c\le10<c≤1, every achieving Gaussian protocol obeys the asymptotic lower bound log⁡Cm≥1128(m/c)1/3−log⁡m−O(1).\log C_m\ge\frac1{128}(m/c)^{1/3}-\log m-O(1).logCm​≥1281​(m/c)1/3−logm−O(1). This is a source-request lower bound; the optimal achievable cost for this source remains undetermined. The proof evaluates a curvature-controlled input certificate for the actual thermally repaired state and applies the Gaussian conversion theorem of the companion paper cited below. 5. Exactly equal entropy does not fix conversion cost For two separate two-mode quartic source families, their mixture probabilities can be adjusted so that their half-loss Shannon entropies are exactly equal. Under a common target, tolerance and failure-inclusive accounting, the inherited matching conversion laws become h(WωA)=h(WωB)=2(1+ln⁡π)+s,log⁡CA(s)=Θ(s−1/3),log⁡CB(s)=Θ(s−1/2).h(W_{\omega_A})=h(W_{\omega_B})=2(1+\ln\pi)+s,\qquad \log C_A(s)=\Theta(s^{-1/3}),\qquad \log C_B(s)=\Theta(s^{-1/2}).h(WωA​​)=h(WωB​​)=2(1+lnπ)+s,logCA​(s)=Θ(s−1/3),logCB​(s)=Θ(s−1/2). The target tolerance is held fixed in these asymptotics. The delivered energies after entropy matching satisfy EA,EB∼s/2E_A,E_B\sim s/2EA​,EB​∼s/2. At exactly equal energy, the two excesses instead share si(E)=2E−(35/8)E2+O(E3)s_i(E)=2E-(35/8)E^2+O(E^3)si​(E)=2E−(35/8)E2+O(E3) and differ by sA(E)−sB(E)=15E3+O(E4)s_A(E)-s_B(E)=15E^3+O(E^4)sA​(E)−sB​(E)=15E3+O(E4). Entropy alone therefore cannot select the cheaper source for a fixed output task. 6. Finite data and finite mode budgets Under a declared displaced-input photon-tail bound Tr⁡[N1N>Kσa]≤τK\operatorname{Tr}[N\mathbf1_{N>K}\sigma_a]\le\tau_KTr[N1N>K​σa​]≤τK​, trusted half loss and all-mode on/off detection with efficiency at least ξmin⁡\xi_{\min}ξmin​, the click probability qqq gives s(σ)≤AKq+τK,AK=K1−(1−ξmin⁡/2)K.s(\sigma)\le A_Kq+\tau_K,\qquad A_K=\frac{K}{1-(1-\xi_{\min}/2)^K}.s(σ)≤AK​q+τK​,AK​=1−(1−ξmin​/2)KK​. A one-sided binomial bound turns this into an entropy confidence certificate. An explicit undisplaced four-photon-cutoff example uses K=4K=4K=4, τK=0\tau_K=0τK​=0, ξ=0.8\xi=0.8ξ=0.8 and N=3,517,336N=3{,}517{,}336N=3,517,336 independent validation blocks, accepting at most 41 clicks, to certify unconditional event error at most 0.050.050.05 with false-acceptance probability at most 0.0010.0010.001 and missed acceptance at most 0.0010.0010.001 on the stated low-click alternative class. All vacuum results count; training, calibration and source heralding are separate costs. When coherent-state approximation alone is the task, the same click measurement supplies a stronger direct fidelity test. The paper also gives all-input finite-budget exclusions above the loss-recovery line. For example, at E=1E=1E=1, α=1.9\alpha=1.9α=1.9, η=0.9505\eta=0.9505η=0.9505 and m=105m=10^5m=105, the certified bound Δα<0.06942\Delta_\alpha<0.06942Δα​<0.06942 rules out a target deficit of 0.10.10.1 nat. A separate finite single-mode preparation model predicts positive Shannon deficit near η=0.97\eta=0.97η=0.97, negative deficit near η=0.85\eta=0.85η=0.85, and a Gaussian-hull witness above 4.4×10−34.4\times10^{-3}4.4×10−3 at half transmission, with explicit preparation, measurement-error and raw-trial budgets in the PDF. 7. Dimensional scales, a strict entropy floor and ORCS Near order two, put α=2−δ\alpha=2-\deltaα=2−δ and L=ln⁡(1/δ)L=\ln(1/\delta)L=ln(1/δ). For the maximum deficit Dm,ED_{m,E}Dm,E​ at fixed total energy, Dm,E(2−δ)=Θm,E(δ/L)for fixed m,Th(δ,E)=ΘE,h(L/δ),D_{m,E}(2-\delta)=\Theta_{m,E}(\delta/L)\quad\text{for fixed }m,\qquad T_h(\delta,E)=\Theta_{E,h}(L/\delta),Dm,E​(2−δ)=Θm,E​(δ/L)for fixed m,Th​(δ,E)=ΘE,h​(L/δ), where ThT_hTh​ is the first mode number allowing a fixed positive deficit hhh. Beyond a sufficiently large fixed multiple of L/δL/\deltaL/δ, Dm,E(2−δ)=ΘE(mδ)D_{m,E}(2-\delta)=\Theta_E(m\delta)Dm,E​(2−δ)=ΘE​(mδ). The manuscript separates proved sufficient fronts from necessary exit bounds; the sharp first-crossing coefficient remains open. At every fixed mode number, an energy-unrestricted strict Shannon floor also holds: h(Wρ)≥mln⁡(2π)+εmh(W_\rho)\ge m\ln(2\pi)+\varepsilon_mh(Wρ​)≥mln(2π)+εm​ with εm>0\varepsilon_m>0εm​>0 for all Wigner-positive states. The ordering-resolved coherence spectrum (ORCS) supplies an exact single-mode loss coordinate. With Cr,k\mathcal C_{r,k}Cr,k​ denoting the ordering-weighted norm of photon-number-difference block kkk, Cr,k(Lηρ)=CTη(r),k(ρ),Tη(r)=1−1−rη.\mathcal C_{r,k}(\mathcal L_\eta\rho)=\mathcal C_{T_\eta(r),k}(\rho),\qquad T_\eta(r)=1-\frac{1-r}{\eta}.Cr,k​(Lη​ρ)=CTη​(r),k​(ρ),Tη​(r)=1−η1−r​. For vacuum–nnn-photon coherence and 1<α<21<\alpha<21<α<2, C1−α/2(Lη∣n⟩⟨0∣)=(2ηα)n.\mathcal C_{1-\alpha/2}(\mathcal L_\eta|n\rangle\langle0|)=\left(\frac{2\eta}{\alpha}\right)^n.C1−α/2​(Lη​∣n⟩⟨0∣)=(α2η​)n. This formula exposes the high-order coherence mechanism at the loss threshold; the universal recovery result is proved through the full nonlinear Wigner-norm inequality. Related papers and history The counterexample paper Wigner entropy below vacuum: physical counterexamples and stability limits expands arXiv:2609.13312v1, submitted on 10 September 2026. This stability paper develops the dimensional, loss-dependent and operational consequences. Its state-approximation and conversion interfaces use the companion results From phase-space entropy to coherent-state error: mode-uniform Rényi–Wehrl stability and Phase records control the conversion cost of non-Gaussian light. The mode-retention comparison connects to Limits to Gaussian concentration of non-Gaussian light.