Abstract We investigate Floquet modulation for measuring the probe-induced AC Stark shift coefficient in optical lattice clocks. Periodic frequency modulation allows a high probe intensity to enlarge the measured frequency difference between the settings at low and high probe power while Bessel function dressing maintains a narrow excitation spectrum. This combination improves sensitivity to the coefficient without sacrificing frequency discrimination. We identify modulation conditions that suppress additional frequency shifts while avoiding strong motional resonances. At the same probe intensities and total measurement time, numerical simulations including preparation time show a lower coefficient uncertainty than conventional Rabi inter-rogation with a single π pulse. At high probe intensities, the Floquet coefficient uncertainty approaches a plateau dominated by Rabi frequency calibration.
Abstract We investigate Floquet modulation for measuring the probe-induced AC Stark shift coefficient in optical lattice clocks. Periodic frequency modulation allows a high probe intensity to enlarge the measured frequency difference between the settings at low and high probe power while Bessel function dressing maintains a narrow excitation spectrum. This combination improves sensitivity to the coefficient without sacrificing frequency discrimination. We identify modulation conditions that suppress additional frequency shifts while avoiding strong motional resonances. At the same probe intensities and total measurement time, numerical simulations including preparation time show a lower coefficient uncertainty than conventional Rabi inter-rogation with a single π pulse. At high probe intensities, the Floquet coefficient uncertainty approaches a plateau dominated by Rabi frequency calibration.
In this paper, we demonstrate a frequency modulation technique to accurately measure the probe Stark shift of optical clocks. The effective coupling strength of the probe laser to the clock transition is precisely controlled by this frequency modulation technique, which is different from the traditional method by controlling the effective coupling strength via changing the probe light power. In an 87Sr optical lattice clock, the probe Stark shifts are measured as a function of the square of the bare state coupling strength. The probe Stark shift coefficient of 87Sr is experimentally determined as −6.0(5)×10−7/Hz using this frequency modulation technique. With the help of frequency modulation, the probe light power can be as large as possible without decreasing the measurement precision and the achieved measurement lever arm is improved by more than one order of magnitude compared with previous results.
Beyond hardware improvements, Floquet Engineering (FE), as a widely used Hamiltonian engineering method, offers new levels of control and promising opportunities for enhancing optical lattice clock performance. However, while FE shapes novel Hamiltonians, its time-periodic nature introduces micromotion, leading to periodic disturbances in the system, such as frequency shifts. In this work, we introduce a dual-modulation (DM) FE method, simultaneously driving the lattice and probing lasers, allowing independent control of atomic motional and electronic degrees of freedom. Using this framework, we theoretically predict and experimentally observe the micromotion shifts. Additionally, by tuning the DM modulation parameters appropriately, we can fully eliminate the Doppler shift caused by the lattice laser modulation. Building on this Doppler-free synchronization modulation, we observe the dynamic localization of atoms in a shallow lattice while eliminating the periodic interference from Doppler shifts. This study proposes a dual-modulation method for optical lattice clocks that synchronously modulates the lattice laser and probing laser to control atomic motion and light-atom interactions independently. The authors derive theoretically and verify experimentally the laws of micromotion shift, and achieving its effective suppression by optimizing modulation parameters.
In this paper, the magic wavelength of the 87Sr optical lattice clock is determined by a method that bypasses the need for lattice trap depth modulation. Instead, it relies on an additional AC Stark shift generated by a dipole beam operating near the frequency of the lattice light and oriented perpendicular to the optical lattice. The magic wavelength is inferred by measuring the AC Stark shift induced by the dipole beam as a function of its power under various frequency detunings. The effect of the dipole beam on the external states of the cold ensemble is evaluated through comparative analysis of the radial and axial sideband spectra, both with and without the dipole beam. Variations in density shift resulting from changes in external states are evaluated using comprehensive numerical calculations. By avoiding trap depth modulation, this method effectively suppresses the influence of the density shift, thereby offering a promising avenue for accurately determining the magic wavelength.
Quantum metrology with ultrahigh precision usually requires atoms prepared in an ultrastable environment with well-defined quantum states. Thus, in optical lattice clock systems deep lattice potentials are used to trap ultracold atoms. However, decoherence, induced by Raman scattering and higher order light shifts, can significantly be reduced if atomic clocks are realized in shallow optical lattices. On the other hand, in such lattices, tunneling among different sites can cause additional dephasing and strongly broadening of the Rabi spectrum. Here, in our experiment, we periodically drive a shallow ^{87}Sr optical lattice clock. Counterintuitively, shaking the system can deform the wide broad spectral line into a sharp peak with 5.4 Hz linewidth. With careful comparison between the theory and experiment, we demonstrate that the Rabi frequency and the Bloch bands can be tuned, simultaneously and independently. Our work not only provides a different idea for quantum metrology, such as building shallow optical lattice clock in outer space, but also paves the way for quantum simulation of new phases of matter by engineering exotic spin orbit couplings.
We periodically modulate the lattice trapping potential of a 87 Sr optical clock to Floquet engineer the clock transition. In the context of atomic gases in lattices, Floquet engineering has been used to shape the dispersion and topology of Bloch quasi-energy bands. Differently from these previous works manipulating the external (spatial) quasi-energies, we target the internal atomic degrees of freedom. We shape Floquet spin quasi-energies and measure their resonance profiles with Rabi spectroscopy. We provide the spectroscopic sensitivity of each band by measuring the Fisher information and show that this is not depleted by the Floquet dynamical modulation. The demonstration that the internal degrees of freedom can be selectively engineered by manipulating the external degrees of freedom inaugurates a novel device with potential applications in metrology, sensing and quantum simulations.
State-of-the-art optical clocks based on neutral atoms have already surpassed the world's best microwave atomic clocks in both accuracy and stability, paving the way to high-precision measurements of elementary aspects of nature, like the search for the drift of fundamental constants or the application of relativistic geodesy.These clocks operate with ensembles trapped in an optical lattice.Normally, high-power trapping laser fields induce a large AC Stark shift on the clock's transition frequency, as the clock states have different polarizabilities.A key feature of lattice clocks is the magic wavelength, for which the atomic polarizabilities of the clock states are equal, therefore compensating a differential frequency shift on the clock transition.In the periodic potential of the optical lattice, the energy spectrum of motional states features a band structure, analogous to electrons in a crystalline structure well-known from solid state physics.Within this band structure, atoms can tunnel between adjacent lattice sites.As a consequence from tunneling motion, the clock transition experiences a frequency shift and a broadening, which becomes pronounced in the shallow lattice regime.This work presents the first demonstration of a 24 Mg optical lattice clock including the precise determination of the frequency of the clock transition, its magic wavelength and its second-order Zeeman shift.Furthermore, the effect of tunneling in an optical lattice for magnesium has been extensively studied via optical spectroscopy of Bloch bands and substantiated with theoretical models, that were initially developed for a strontium optical lattice clock.Measuring lattice light induced frequency shifts of the clock transition for various lattice wavelengths and intensities, yielded a value of the magic wavelength of the 1 S 0 → 3 P 0 clock transition in 24 Mg of 468.463(207) nm.This value is in well agreement with a recent theoretical calculation of 468.45(23) nm, using a refined atomic structure model.The experimental value for the magic wavelength was independently verified with optical spectroscopy of Bloch bands carried out on the clock transition.Here, the AC Stark modified band structure is directly probed by a single frequency scan of the carrier resonance, featuring an asymmetric line shape, that is strongly dependent on the lattice wavelength.This technique demonstrates a novel method for the determination of the magic wavelength and could also be applied to other atomic species.In bosonic isotopes of alkaline earth(-like) elements, like 24 Mg, optical dipole excitation of the spin-forbidden 1 S 0 → 3 P 0 clock transition can be enhanced, e.g. by applying an external magnetic field.While these bosons are insensitive to first-order Zeeman shifts, the second-order Zeeman effect displays a dominant contribution to the clock's error budget.In this thesis, the magnetic polarizability β is measured to be -206.6(2.0)MHz/T 2 , consistent with a theoretical calculation, and the clock transition frequency was found to be 655 058 646 691(101) kHz.