Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Efficient Spatial Photon Coincidence Imaging with a Time-Correlated Single-Photon Counting SPAD Camera

Ruotong Feng, Malo Joly, Edoardo Charbon A, Hugo Defienne

Published Jan 1, 2026• 0 citations
OpenAlex

Abstract

We demonstrate spatial photon coincidence measurements using a TCSPC SPAD camera. We measure the momentum correlation width of type-I SPDC photon pairs generated in a BBO crystal in a far-field configuration.

Related papers

Full field measurement of spatial correlated photon pairs with an EMCCD camera

M. Edgar, D. S. Tasca, Frauke Izdebski +5 more

The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.

•Jan 1, 2012•0 citations

Real-time entangled photon-pair imaging towards field deployment

Robin Camphausen, Álvaro Cuevas, Alexander Demuth +8 more

Quantum technology promises improvements in imaging, computing, and communication, for example using the resource of entanglement between photons with spatial correlations. Detecting spatial correlations, or coincidences, between entangled photons scalably, efficiently, and affordably is therefore an essential capability. However, this task is non-trivial for existing camera technologies, which require low illumination intensities or low detection duty cycles to count coincidences at high signal-to-noise ratios, resulting in long acquisition time, or use expensive custom electronic components. Here, we present an entanglement imaging system based around a novel Single-Photon Avalanche Diode (SPAD) array camera, optimized for sparse illumination with correlated photon pairs. The system is capable of maintaining a duty cycle close to 100%, while simultaneously detecting spatially resolved coincidences with high SNR, enabling the acquisition of real-time entanglement videos at a ~Hz frame rate. We use our system to demonstrate real-time monitoring of entanglement interference visibility, optical system point spread function, as well as real-time widefield entanglement-enhanced phase imaging. Our results show that SPAD array cameras represent a natural choice for scalable entanglement detection and imaging applications.

•Nov 30, 2023•1 citation

Imaging high-dimensional entanglement correlations with a SPAD camera

Bienvenu I. Ndagano, Hugo Defienne, Ashley Lyons +4 more

Here we present the reconstruction of hvo-photon spatial entanglement correlations using a single-photon avalanche diode (SPAD) camera. Owing to its high frame rate, our SPAD camera provides a 1000x speed-up in the data acquisition time compared to CCD-based single-photon cameras, effectively reducing measurement time from many hours to just a few minutes.

Imaging and Applied Optics•Jan 1, 2020•0 citations

Analysis of a quantum imaging system based on SPAD detection

Fabio Severini, Francesca Madonini, Federica Villa

The ability to generate and handle quantum correlations in twin-beam states is the foundation to overcome the imaging limitations imposed by classical light [1], relying on efficient detectors able to select temporal correlations among photons with maximized signal-to-noise ratio. Indeed, quantum information is contained in the interaction with the sample of just two photons, thus losing even one of them or mixing them up with background can completely compromise the experiment. To this end, assessing and evaluating the expected probability of measurement errors is of utmost importance to optimize the detector design. A typical experimental setup of a quantum imaging system based on Spontaneous Parametric Down Conversion (SPDC), the most effective way of producing temporally and spatially correlated entangled photons [2], involves a pump laser hitting a non-linear birefringent crystal producing a down-converted signal, some passive optical components to generate polarization-entangled photons and a pixelated photon detector that eventually reveals the position of coincident entangled photons. The overall detection efficiency of the measurement setup (i.e. heralding efficiency ηH) gathers all its possible losses and non-idealities of the mentioned setup components, namely the crystal conversion efficiency, the optical losses, the detector Photon Detection Efficiency (PDE) and fill-factor. In this study, we consider a detection based on a Single Photon Avalanche Diode (SPAD) array, able to detect coincidences on-chip and with event-driven architecture, which provides fast readout, low power consumption and optimized data throughput. However, related to every on-chip coincidence detection and event-driven based architecture, some operations require a certain amount of time to be performed that, combined with the generation of undesired single photons (both due to limited heralding efficiency and SPAD Dark Count Rate, DCR), yield to three measurement errors, here described with their related probabilities. Firstly, due to the finite duration of the coincidence window ∆tCOINC, there exist a probability Pfalseof wrongly detecting as coincident photons two single photons, and can be expressed as:\begin{equation*}{P_{false}} = \frac{{\left[ {2{\mu _{SOURCE{\text{ }}}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}{{{\mu _{SOURCE}}\eta _H^2 + \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + DCR} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}\tag{1}\end{equation*}where µSOURCEis the number of photon pairs generated by an ideal non-linear crystal. Secondly, in the time needed for the array to "freeze" the pixels state after a coincidence event (∆tFREEZE) so that they can be readout, there is the probability Pspuriousof detecting a third spurious event after a coincidence has been detected, which is expressed as:\begin{equation*}{P_{spurious}} = 1 - {e^{ - \left[ {2{\mu _{SOURCE\eta }}_H\left( {1 - {\eta _H}} \right) + DCR} \right]\Delta {t_{FREEZE}}}}\tag{2}\end{equation*}

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations

Imaging the Joint Probability Distribution of Spatially Entangled Photon Pairs with a Camera

Matthew C. Reichert, Hugo Defienne, Jason W. Fleischer

We present massively parallel coincidence counting of entangled photon pairs by measuring coincidences between all pairs of pixels in a single-photon-sensitive camera, including the case where both entangled photons arrive in the same pixel.

Imaging and Applied Optics•Jan 1, 2018•0 citations

Quantum imaging with a photon counting camera

Osian Wolley, Thomas Gregory, Sebastian M. J. Beer +2 more

Classical light sources emit a randomly-timed stream of individual photons, the spatial distribution of which can be detected with a camera to form an image. Quantum light sources, based on parametric down conversion, emit photons as correlated photon-pairs. The spatial correlations between the photons enables imaging systems where the preferential selection of photon-pairs allows for enhancements in the noise performance over what is possible using classical light sources. However, until now the technical challenge of measuring, and correlating both photons has led to system complexity. Here we show that a camera capable of resolving the number of individual photons in each pixel of the detector array can be used to record an image formed from these photon-pair events and hence achieve a greater contrast than possible using a classical light source. We achieve an enhancement in the ratio of two-photon events compared to one-photon events using spatially correlated SPDC light compared to uncorrelated illumination by a LED. These results indicate the potential advantages of using photon counting cameras in quantum imaging schemes and these advantages will further increase as the technology is developed. Operating in photon sparse regimes such systems have potential applications in low-light microscopy and covert imaging.

Scientific Reports•May 18, 2022•49 citations
The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.
Quantum technology promises improvements in imaging, computing, and communication, for example using the resource of entanglement between photons with spatial correlations. Detecting spatial correlations, or coincidences, between entangled photons scalably, efficiently, and affordably is therefore an essential capability. However, this task is non-trivial for existing camera technologies, which require low illumination intensities or low detection duty cycles to count coincidences at high signal-to-noise ratios, resulting in long acquisition time, or use expensive custom electronic components. Here, we present an entanglement imaging system based around a novel Single-Photon Avalanche Diode (SPAD) array camera, optimized for sparse illumination with correlated photon pairs. The system is capable of maintaining a duty cycle close to 100%, while simultaneously detecting spatially resolved coincidences with high SNR, enabling the acquisition of real-time entanglement videos at a ~Hz frame rate. We use our system to demonstrate real-time monitoring of entanglement interference visibility, optical system point spread function, as well as real-time widefield entanglement-enhanced phase imaging. Our results show that SPAD array cameras represent a natural choice for scalable entanglement detection and imaging applications.
The ability to generate and handle quantum correlations in twin-beam states is the foundation to overcome the imaging limitations imposed by classical light [1], relying on efficient detectors able to select temporal correlations among photons with maximized signal-to-noise ratio. Indeed, quantum information is contained in the interaction with the sample of just two photons, thus losing even one of them or mixing them up with background can completely compromise the experiment. To this end, assessing and evaluating the expected probability of measurement errors is of utmost importance to optimize the detector design. A typical experimental setup of a quantum imaging system based on Spontaneous Parametric Down Conversion (SPDC), the most effective way of producing temporally and spatially correlated entangled photons [2], involves a pump laser hitting a non-linear birefringent crystal producing a down-converted signal, some passive optical components to generate polarization-entangled photons and a pixelated photon detector that eventually reveals the position of coincident entangled photons. The overall detection efficiency of the measurement setup (i.e. heralding efficiency ηH) gathers all its possible losses and non-idealities of the mentioned setup components, namely the crystal conversion efficiency, the optical losses, the detector Photon Detection Efficiency (PDE) and fill-factor. In this study, we consider a detection based on a Single Photon Avalanche Diode (SPAD) array, able to detect coincidences on-chip and with event-driven architecture, which provides fast readout, low power consumption and optimized data throughput. However, related to every on-chip coincidence detection and event-driven based architecture, some operations require a certain amount of time to be performed that, combined with the generation of undesired single photons (both due to limited heralding efficiency and SPAD Dark Count Rate, DCR), yield to three measurement errors, here described with their related probabilities. Firstly, due to the finite duration of the coincidence window ∆tCOINC, there exist a probability Pfalseof wrongly detecting as coincident photons two single photons, and can be expressed as:\begin{equation*}{P_{false}} = \frac{{\left[ {2{\mu _{SOURCE{\text{ }}}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}{{{\mu _{SOURCE}}\eta _H^2 + \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + DCR} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}\tag{1}\end{equation*}where µSOURCEis the number of photon pairs generated by an ideal non-linear crystal. Secondly, in the time needed for the array to "freeze" the pixels state after a coincidence event (∆tFREEZE) so that they can be readout, there is the probability Pspuriousof detecting a third spurious event after a coincidence has been detected, which is expressed as:\begin{equation*}{P_{spurious}} = 1 - {e^{ - \left[ {2{\mu _{SOURCE\eta }}_H\left( {1 - {\eta _H}} \right) + DCR} \right]\Delta {t_{FREEZE}}}}\tag{2}\end{equation*}
Classical light sources emit a randomly-timed stream of individual photons, the spatial distribution of which can be detected with a camera to form an image. Quantum light sources, based on parametric down conversion, emit photons as correlated photon-pairs. The spatial correlations between the photons enables imaging systems where the preferential selection of photon-pairs allows for enhancements in the noise performance over what is possible using classical light sources. However, until now the technical challenge of measuring, and correlating both photons has led to system complexity. Here we show that a camera capable of resolving the number of individual photons in each pixel of the detector array can be used to record an image formed from these photon-pair events and hence achieve a greater contrast than possible using a classical light source. We achieve an enhancement in the ratio of two-photon events compared to one-photon events using spatially correlated SPDC light compared to uncorrelated illumination by a LED. These results indicate the potential advantages of using photon counting cameras in quantum imaging schemes and these advantages will further increase as the technology is developed. Operating in photon sparse regimes such systems have potential applications in low-light microscopy and covert imaging.