Scaling Digital-Analog Quantum Kernels for Medical Image Classification

Lorenzo Marcoccia, Carlos Flores-Garrigós, Yolanda Vives‐Gilabert, José D. Martín-Guerrero, Marco Chessari, Ermanno Cordelli

Published Jun 1, 2026• 0 citations
Publisher

Abstract

Medical image classification often struggles with data scarcity and high-dimensional features, yet quantum kernels offer untapped potential for efficient feature extraction in such tasks. This study addresses these challenges by integrating digitalanalog quantum kernels, rooted in the Digital-Analog Quantum Computing paradigm, into classical machine learning pipelines as non-parameterized feature extractors paired with lightweight classifiers. Using two binary benchmarks from the MedMNIST collection, we systematically vary quantum circuit architectures through iterative block repetitions and quantum pooling techniques to evaluate their influence on performance. Our analysis quantifies trade-offs between circuit depth and classification accuracy, alongside robustness to simulated bit-flip noise. Results reveal that moderate circuit depths enhance accuracy on larger datasets, although data scarcity limits gains on smaller cohorts, while quantum pooling effectively reduces dimensionality and cuts classical training costs without sacrificing pattern integrity. Despite the datasets' limited scale, which tempers generalizability claims, these findings strongly encourage further exploration of hybrid quantum-classical approaches for medical imaging.

DOI
10.1109/cbms69103.2026.00181

Related papers

A Hybrid Quantum-Enhanced Sandwich Convolutional Neural Network for Medical Image Classification

Changzhou Long, Shuaiyu Li, Meng Huang +2 more

Introduction: Medical image classification is a crucial task in cancer diagnosis, relying on the accurate analysis of high-dimensional imaging data. While Convolutional Neural Networks (CNNs) have shown great success in this domain, their performance is often limited by the shallow feature expressiveness and overfitting, particularly in small or heterogeneous datasets. Methods: Quantum machine learning offers new opportunities through high-dimensional representations and nonlinear transformations. In this work, we propose a Quantum-Enhanced Sandwich Convolutional Neural Network (QSCNN), a layered hybrid architecture that integrates quantum and classical modules. The model employs a quanvolutional layer for localized quantum feature extraction, followed by conventional convolution and pooling for hierarchical representation learning, and a variational quantum classifier for nonlinear decision-making. Results: QSCNN achieved higher accuracy and training stability than classical CNNs and QCCNN baselines across three medical imaging tasks.: brain tumor MRI, skin cancer dermoscopy, and lung cancer CT. Circuit depth analysis revealed a trade-off between expressiveness and robustness, and additional experiments with depolarizing noise confirmed the model’s resilience under realistic quantum error conditions. Discussion: This suggests that circuit design choices influence hybrid model behavior and generalization, supporting the feasibility of quantum-enhanced methods for small-sample medical imaging. However, the current evaluation is limited to relatively small benchmark datasets, and broader validation on large-scale data will be essential to confirm clinical applicability. Conclusion: In summary, QSCNN presents a feasible hybrid framework for enhancing medical image classification with quantum features. While preliminary, our results suggest potential advantages in accuracy and stability under NISQ conditions.

Current Bioinformatics•Jan 9, 2026•2 citations

Quantum enhanced machine learning for medical image analysis: a hybrid approach

Soha Rawas, Duaa AlSaeed

Purpose This study investigates the integration of quantum-enhanced machine learning (QML) into medical image analysis, focusing on classification and feature extraction tasks. It aims to evaluate whether hybrid quantum-classical models can overcome the limitations of traditional machine learning in handling high-dimensional, clinically relevant imaging data. Design/methodology/approach Hybrid architectures combining classical preprocessing with quantum components, specifically variational quantum circuits (VQCs) and quantum kernel methods, were developed and implemented in simulated quantum environments using Qiskit and PennyLane on Google Colab. Publicly available datasets (ChestX-ray14, Brain Tumor MRI and CT Hemorrhage) were preprocessed and encoded into quantum states. Model performance was evaluated against classical baselines (MLP and CNN) using accuracy, precision, recall, F1-score, convergence speed and trainable parameters. Findings Quantum-enhanced models achieved competitive or superior performance compared to classical models with significantly fewer trainable parameters and faster convergence. The Quantum Kernel SVM demonstrated the highest precision (89.1%) and F1-score (88.5%) using only 8 parameters, while VQC models converged up to 2× faster than classical baselines. These results highlight the potential of QML to improve efficiency, robustness and scalability in diagnostic imaging workflows, particularly in resource-constrained or data-limited settings. Research limitations/implications The study relies on simulated quantum environments, which do not capture hardware noise or qubit limitations. Future work will extend to real quantum devices, multimodal data integration and interpretability strategies. Practical implications Quantum kernel methods and lightweight VQC architectures enable faster, resource-efficient diagnostic modeling, making them suitable for clinical environments with limited computational capacity or time-sensitive decision-making needs. Social implications Improving the efficiency and accessibility of medical image analysis has the potential to support faster diagnosis and enhance healthcare delivery, particularly in underserved or resource-limited regions. Originality/value This study provides a practical evaluation of hybrid quantum-classical models applied to multiple real medical imaging datasets in a reproducible simulated environment. It offers an early-stage framework demonstrating how QML techniques can be integrated into existing machine learning pipelines for medical image analysis.

Applied Computing and Informatics•Jan 27, 2026•5 citations

A hybrid classical-quantum approach for medical image classification

Trilok Nath Pandey, Shrishti Singh, Smriti Verma +1 more

With millions of medical data being produced daily, it is important to leverage current technology to improve the healthcare system. As traditional deep learning models are unable to effectively handle high-dimensional data, a hybrid classical-quantum approach is used to enhance traditional deep learning algorithms. The hybrid classical-quantum models are built upon the classical deep learning framework with quantum techniques. The classical layers are utilized for feature extraction while the quantum layer is used for computational tasks. This addresses computational limitations and data imbalance challenges in medical image analysis. Transfer learning models, such as ResNet18 and InceptionV3, are used in conjunction with a quantum variational circuit to perform the task. The model is trained on a chest X-ray dataset, which consists of two sets of data: binary and multiclass. The binary dataset consists of Normal and COVID-19 images, while the multiclass dataset has COVID-19, Normal, and Tuberculosis images for classification. PennyLane, as a simulator, has been used to perform quantum computing. The dataset has also been used to train the traditional transfer learning models, pre-trained ResNet18, and their results have been compared. Out of all the models tested, the hybrid classical-quantum model, namely Hybrid ResNet18, performed the best. It achieved an accuracy of 93.22% for the binary classification task and 93.91% for the multiclass classification. The results show that there is a statistically significant improvement in classification accuracy and F1-score of the hybrid approach over the classical transfer learning baselines under a simulation-based environment. This sets the stage for further research on real-world physical quantum hardware. Class imbalance and overlapping predictions have been addressed using methods such as data augmentation and confusion matrix analysis. Thus, quantum machine learning could be used as a vital tool to analyze medical data for better diagnostic results.

Scientific Reports•Sep 17, 2026•0 citations

HQCNN: a hybrid quantum-classical neural network with Fourier-inspired quantum attention for medical image classification

Shahjalal Khan, Jahid Karim Fahim, Pintu Chandra Paul +5 more

Medical image classification is a critical component of modern healthcare; however, accurate diagnosis remains challenging due to limited annotated datasets, class imbalance, and the high dimensionality of medical imaging data. To address these challenges, a hybrid quantum-classical neural network (HQCNN) is proposed, integrating classical deep learning with variational quantum learning for medical image classification. The proposed architecture combines a five-layer convolutional neural network (CNN) for hierarchical feature extraction with a lightweight 4-qubit variational quantum circuit (VQC) incorporating quantum state encoding, superposition and entanglement mechanisms, and a quantum attention-Fourier (QAF) module. This hybrid design aims to improve nonlinear feature representation and quantum parameter efficiency while maintaining a shallow quantum circuit suitable for noisy intermediate-scale quantum (NISQ)-era constraints. Experimental evaluation on six MedMNIST benchmark datasets demonstrated competitive performance across both binary and multi-class classification tasks. HQCNN achieved 98.88% accuracy on the binary subset of PathMNIST (classes 0 vs. 1), 97.61% accuracy on the multi-class OrganAMNIST dataset, and 86.29% accuracy on BreastMNIST. Comparative experiments and statistical analyses demonstrated consistent improvements over the controlled BHQNN baseline, while component-wise ablation studies showed that the QAF module, superposition and entanglement mechanisms, and expressive parameterized rotations contributed to classification performance in a complementary and dataset-dependent manner. Moreover, HQCNN reduced the number of trainable quantum parameters by approximately 55.6% compared with the baseline hybrid quantum neural network (BHQNN). Noise-aware simulations further showed that the model retained relatively stable predictive performance under moderate depolarizing noise, supporting further evaluation under near-term quantum computing conditions. Overall, the results demonstrate that HQCNN provides a parameter-efficient hybrid quantum-classical framework for medical image classification and offers a promising foundation for further investigation of quantum-enhanced medical image analysis.

International Journal of Advanced Technology and Engineering Exploration•Aug 31, 2026•0 citations

Hybrid Quantum-Classical Feature Extraction approach for Image Classification using Autoencoders and Quantum SVMs

Donovan Slabbert, Francesco Petruccione

In order to leverage quantum computers for machine learning tasks such as image classification, careful consideration is required: NISQ-era quantum computers have limitations, which include noise, scalability, read-in and read-out times, and gate operation times. Therefore, strategies should be devised to mitigate the impact that complex datasets can have on the overall efficiency of a quantum machine learning pipeline. This may otherwise lead to excessive resource demands or increased noise. We apply a classical feature extraction method using a ResNet10-inspired convolutional autoencoder to both reduce the dimensionality of the dataset and extract abstract and meaningful features before feeding them into a quantum machine learning block. The quantum block of choice is a quantum-enhanced support vector machine (QSVM), as support vector machines typically do not require large sample sizes to identify patterns in data and have short-depth quantum circuits, which limits the impact of noise. The autoencoder is trained to extract meaningful features through image reconstruction, aiming to minimize the mean squared error across a training set. Three image datasets are used to illustrate the pipeline: HTRU-1, MNIST, and CIFAR-10. We also include a quantum-enhanced one-class support vector machine (QOCSVM) for the highly unbalanced HTRU-1 set, as well as classical machine learning results to serve as a benchmark. Finally, the HTRU-2 dataset is also included to serve as a benchmark for a dataset with well-correlated features. The autoencoder achieved near-perfect reconstruction and high classification accuracy for MNIST, while CIFAR-10 showed poorer performance due to image complexity, and HTRU-1 struggled because of dataset imbalance. This highlights the need for a balance between dimensionality reduction through classical feature extraction and prediction performance using quantum methods.

arXiv:2410.18814•Oct 24, 2024•9 citations

Benchmarking MedMNIST dataset on real quantum hardware

Gurinder Singh, Hongni Jin, Kenneth M. Merz

Quantum machine learning (QML) has emerged as a promising domain to leverage the computational capabilities of quantum systems to solve complex classification tasks. In this work, we present the first comprehensive QML study by benchmarking the MedMNIST-a diverse collection of medical imaging datasets on a 127-qubit real IBM quantum hardware, to evaluate the feasibility and performance of quantum models (without any classical neural networks) in practical applications. This study explores recent advancements in quantum computing such as device-aware quantum circuits, error suppression, and mitigation for medical image classification. The proposed methodology is comprised of three stages: preprocessing, generation of noise-resilient and hardware-efficient quantum circuits, optimizing/training of quantum circuits on classical hardware, and inference on real IBM quantum hardware. Firstly, we process all input images in the preprocessing stage to reduce the spatial dimension due to quantum hardware limitations. We generate hardware-efficient quantum circuits using backend properties expressible to learn complex patterns for medical image classification. After classical optimization of QML models, we perform inference on real quantum hardware. We also incorporate advanced error suppression and mitigation techniques in our QML workflow, including dynamical decoupling (DD), gate twirling (Twir), and matrix-free measurement mitigation (M3) to mitigate the effects of noise and improve classification performance. The experimental results showcase the potential of quantum computing for medical imaging and establish a benchmark for future advancements in QML applied to healthcare.

arXiv:2502.13056•Scientific Reports•Feb 14, 2026•20 citations
Medical image classification often struggles with data scarcity and high-dimensional features, yet quantum kernels offer untapped potential for efficient feature extraction in such tasks. This study addresses these challenges by integrating digitalanalog quantum kernels, rooted in the Digital-Analog Quantum Computing paradigm, into classical machine learning pipelines as non-parameterized feature extractors paired with lightweight classifiers. Using two binary benchmarks from the MedMNIST collection, we systematically vary quantum circuit architectures through iterative block repetitions and quantum pooling techniques to evaluate their influence on performance. Our analysis quantifies trade-offs between circuit depth and classification accuracy, alongside robustness to simulated bit-flip noise. Results reveal that moderate circuit depths enhance accuracy on larger datasets, although data scarcity limits gains on smaller cohorts, while quantum pooling effectively reduces dimensionality and cuts classical training costs without sacrificing pattern integrity. Despite the datasets' limited scale, which tempers generalizability claims, these findings strongly encourage further exploration of hybrid quantum-classical approaches for medical imaging.
Introduction: Medical image classification is a crucial task in cancer diagnosis, relying on the accurate analysis of high-dimensional imaging data. While Convolutional Neural Networks (CNNs) have shown great success in this domain, their performance is often limited by the shallow feature expressiveness and overfitting, particularly in small or heterogeneous datasets. Methods: Quantum machine learning offers new opportunities through high-dimensional representations and nonlinear transformations. In this work, we propose a Quantum-Enhanced Sandwich Convolutional Neural Network (QSCNN), a layered hybrid architecture that integrates quantum and classical modules. The model employs a quanvolutional layer for localized quantum feature extraction, followed by conventional convolution and pooling for hierarchical representation learning, and a variational quantum classifier for nonlinear decision-making. Results: QSCNN achieved higher accuracy and training stability than classical CNNs and QCCNN baselines across three medical imaging tasks.: brain tumor MRI, skin cancer dermoscopy, and lung cancer CT. Circuit depth analysis revealed a trade-off between expressiveness and robustness, and additional experiments with depolarizing noise confirmed the model’s resilience under realistic quantum error conditions. Discussion: This suggests that circuit design choices influence hybrid model behavior and generalization, supporting the feasibility of quantum-enhanced methods for small-sample medical imaging. However, the current evaluation is limited to relatively small benchmark datasets, and broader validation on large-scale data will be essential to confirm clinical applicability. Conclusion: In summary, QSCNN presents a feasible hybrid framework for enhancing medical image classification with quantum features. While preliminary, our results suggest potential advantages in accuracy and stability under NISQ conditions.
Purpose This study investigates the integration of quantum-enhanced machine learning (QML) into medical image analysis, focusing on classification and feature extraction tasks. It aims to evaluate whether hybrid quantum-classical models can overcome the limitations of traditional machine learning in handling high-dimensional, clinically relevant imaging data. Design/methodology/approach Hybrid architectures combining classical preprocessing with quantum components, specifically variational quantum circuits (VQCs) and quantum kernel methods, were developed and implemented in simulated quantum environments using Qiskit and PennyLane on Google Colab. Publicly available datasets (ChestX-ray14, Brain Tumor MRI and CT Hemorrhage) were preprocessed and encoded into quantum states. Model performance was evaluated against classical baselines (MLP and CNN) using accuracy, precision, recall, F1-score, convergence speed and trainable parameters. Findings Quantum-enhanced models achieved competitive or superior performance compared to classical models with significantly fewer trainable parameters and faster convergence. The Quantum Kernel SVM demonstrated the highest precision (89.1%) and F1-score (88.5%) using only 8 parameters, while VQC models converged up to 2× faster than classical baselines. These results highlight the potential of QML to improve efficiency, robustness and scalability in diagnostic imaging workflows, particularly in resource-constrained or data-limited settings. Research limitations/implications The study relies on simulated quantum environments, which do not capture hardware noise or qubit limitations. Future work will extend to real quantum devices, multimodal data integration and interpretability strategies. Practical implications Quantum kernel methods and lightweight VQC architectures enable faster, resource-efficient diagnostic modeling, making them suitable for clinical environments with limited computational capacity or time-sensitive decision-making needs. Social implications Improving the efficiency and accessibility of medical image analysis has the potential to support faster diagnosis and enhance healthcare delivery, particularly in underserved or resource-limited regions. Originality/value This study provides a practical evaluation of hybrid quantum-classical models applied to multiple real medical imaging datasets in a reproducible simulated environment. It offers an early-stage framework demonstrating how QML techniques can be integrated into existing machine learning pipelines for medical image analysis.
With millions of medical data being produced daily, it is important to leverage current technology to improve the healthcare system. As traditional deep learning models are unable to effectively handle high-dimensional data, a hybrid classical-quantum approach is used to enhance traditional deep learning algorithms. The hybrid classical-quantum models are built upon the classical deep learning framework with quantum techniques. The classical layers are utilized for feature extraction while the quantum layer is used for computational tasks. This addresses computational limitations and data imbalance challenges in medical image analysis. Transfer learning models, such as ResNet18 and InceptionV3, are used in conjunction with a quantum variational circuit to perform the task. The model is trained on a chest X-ray dataset, which consists of two sets of data: binary and multiclass. The binary dataset consists of Normal and COVID-19 images, while the multiclass dataset has COVID-19, Normal, and Tuberculosis images for classification. PennyLane, as a simulator, has been used to perform quantum computing. The dataset has also been used to train the traditional transfer learning models, pre-trained ResNet18, and their results have been compared. Out of all the models tested, the hybrid classical-quantum model, namely Hybrid ResNet18, performed the best. It achieved an accuracy of 93.22% for the binary classification task and 93.91% for the multiclass classification. The results show that there is a statistically significant improvement in classification accuracy and F1-score of the hybrid approach over the classical transfer learning baselines under a simulation-based environment. This sets the stage for further research on real-world physical quantum hardware. Class imbalance and overlapping predictions have been addressed using methods such as data augmentation and confusion matrix analysis. Thus, quantum machine learning could be used as a vital tool to analyze medical data for better diagnostic results.
Medical image classification is a critical component of modern healthcare; however, accurate diagnosis remains challenging due to limited annotated datasets, class imbalance, and the high dimensionality of medical imaging data. To address these challenges, a hybrid quantum-classical neural network (HQCNN) is proposed, integrating classical deep learning with variational quantum learning for medical image classification. The proposed architecture combines a five-layer convolutional neural network (CNN) for hierarchical feature extraction with a lightweight 4-qubit variational quantum circuit (VQC) incorporating quantum state encoding, superposition and entanglement mechanisms, and a quantum attention-Fourier (QAF) module. This hybrid design aims to improve nonlinear feature representation and quantum parameter efficiency while maintaining a shallow quantum circuit suitable for noisy intermediate-scale quantum (NISQ)-era constraints. Experimental evaluation on six MedMNIST benchmark datasets demonstrated competitive performance across both binary and multi-class classification tasks. HQCNN achieved 98.88% accuracy on the binary subset of PathMNIST (classes 0 vs. 1), 97.61% accuracy on the multi-class OrganAMNIST dataset, and 86.29% accuracy on BreastMNIST. Comparative experiments and statistical analyses demonstrated consistent improvements over the controlled BHQNN baseline, while component-wise ablation studies showed that the QAF module, superposition and entanglement mechanisms, and expressive parameterized rotations contributed to classification performance in a complementary and dataset-dependent manner. Moreover, HQCNN reduced the number of trainable quantum parameters by approximately 55.6% compared with the baseline hybrid quantum neural network (BHQNN). Noise-aware simulations further showed that the model retained relatively stable predictive performance under moderate depolarizing noise, supporting further evaluation under near-term quantum computing conditions. Overall, the results demonstrate that HQCNN provides a parameter-efficient hybrid quantum-classical framework for medical image classification and offers a promising foundation for further investigation of quantum-enhanced medical image analysis.
In order to leverage quantum computers for machine learning tasks such as image classification, careful consideration is required: NISQ-era quantum computers have limitations, which include noise, scalability, read-in and read-out times, and gate operation times. Therefore, strategies should be devised to mitigate the impact that complex datasets can have on the overall efficiency of a quantum machine learning pipeline. This may otherwise lead to excessive resource demands or increased noise. We apply a classical feature extraction method using a ResNet10-inspired convolutional autoencoder to both reduce the dimensionality of the dataset and extract abstract and meaningful features before feeding them into a quantum machine learning block. The quantum block of choice is a quantum-enhanced support vector machine (QSVM), as support vector machines typically do not require large sample sizes to identify patterns in data and have short-depth quantum circuits, which limits the impact of noise. The autoencoder is trained to extract meaningful features through image reconstruction, aiming to minimize the mean squared error across a training set. Three image datasets are used to illustrate the pipeline: HTRU-1, MNIST, and CIFAR-10. We also include a quantum-enhanced one-class support vector machine (QOCSVM) for the highly unbalanced HTRU-1 set, as well as classical machine learning results to serve as a benchmark. Finally, the HTRU-2 dataset is also included to serve as a benchmark for a dataset with well-correlated features. The autoencoder achieved near-perfect reconstruction and high classification accuracy for MNIST, while CIFAR-10 showed poorer performance due to image complexity, and HTRU-1 struggled because of dataset imbalance. This highlights the need for a balance between dimensionality reduction through classical feature extraction and prediction performance using quantum methods.
Quantum machine learning (QML) has emerged as a promising domain to leverage the computational capabilities of quantum systems to solve complex classification tasks. In this work, we present the first comprehensive QML study by benchmarking the MedMNIST-a diverse collection of medical imaging datasets on a 127-qubit real IBM quantum hardware, to evaluate the feasibility and performance of quantum models (without any classical neural networks) in practical applications. This study explores recent advancements in quantum computing such as device-aware quantum circuits, error suppression, and mitigation for medical image classification. The proposed methodology is comprised of three stages: preprocessing, generation of noise-resilient and hardware-efficient quantum circuits, optimizing/training of quantum circuits on classical hardware, and inference on real IBM quantum hardware. Firstly, we process all input images in the preprocessing stage to reduce the spatial dimension due to quantum hardware limitations. We generate hardware-efficient quantum circuits using backend properties expressible to learn complex patterns for medical image classification. After classical optimization of QML models, we perform inference on real quantum hardware. We also incorporate advanced error suppression and mitigation techniques in our QML workflow, including dynamical decoupling (DD), gate twirling (Twir), and matrix-free measurement mitigation (M3) to mitigate the effects of noise and improve classification performance. The experimental results showcase the potential of quantum computing for medical imaging and establish a benchmark for future advancements in QML applied to healthcare.