Journal of Infrared Millimeter and Terahertz Waves

Continuous-Wave Noise Equivalent Power and Minimum Pulse Power Detectable by a Superconducting Terahertz Bolometer

T. I. Novikova, K. Shein, Sergey V. Seliverstov, G. N. Gol'Tsman, G. Kh. Kitaeva

Published Oct 1, 2026• 0 citations
Publisher
DOI
10.1007/s10762-026-01183-8

Related papers

A Superconducting Bolometer Antenna-Coupled to Terahertz Waves

Sara Cibella, P. Carelli, Maria Gabriella Castellano +4 more

Journal of Low Temperature Physics•Jan 13, 2009•9 citations

Low Noise Terahertz Receivers Based on Superconducting NbN Hot Electron Bolometers

J. Chen, Le Kang, Min Liang +2 more

Softwaretechnik-Trends•Apr 1, 2009•0 citations

Superconducting noise bolometer as a direct detector

Andrew G. Semenov, Heinz‐Wilhelm Hübers, K. Ilin +2 more

•Jan 1, 2005•0 citations

Microwave probing of relaxation oscillations related to terahertz power detection in superconducting hot electron bolometers

Runfeng Su, Y D Zhang, Xuecou Tu +8 more

Abstract Relaxation oscillations related to terahertz (THz) power detection in superconducting niobium nitride hot electron bolometers (HEBs) have been studied using microwaves as a probe. The reflected microwave signal, which is related to the impedance changes of the HEB irradiated by an incident THz signal, can be used to characterize relaxation oscillations. The frequency of relaxation oscillation switching between the superconducting and resistive states increases linearly with incident THz power but nonlinearly with bias voltage or bath temperature. The observed strong periodic pulse trains of relaxation oscillations have a maximum duty cycle of ∼50%. These strong switching pulses indicate that DC Joule heating, THz radiation or thermal energy is absorbed in the bi-stable region of the HEB intermittently. In addition to relaxation oscillations, we also see weaker oscillations when the device is in the resistive state, which we call intrinsic oscillations. These have a constant frequency at the order of 10 kHz which is independent of external stimuli. The weak periodic pulse trains at a constant frequency can be divided into mainly two types—one is the pulse train with a small duty cycle and the other is the quasi-square wave. Measurement of these oscillations in HEBs has some practical applications. Digital THz power measurement with frequencies below and above the gap frequency can be made based on the linearity between relaxation oscillation frequency and incident THz power. The relaxation oscillation frequency can be used to estimate the maximum speed of a THz direct detection system especially for a multi-pixel HEB array. In particular, extra noise induced by relaxation oscillations and intrinsic oscillations can be determined for the HEB operating as a THz direct detector.

Superconductor Science and Technology•Jul 9, 2019•7 citations

Terahertz Direct Detection Behavior of a Superconducting NbN bolometer by Noise Thermometry

Hao Gao, Wei Miao, Kangmin Zhou +1 more

In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2019•0 citations

Terahertz Direct Detection Characteristics of a Superconducting NbN Bolometer

Yuan Ren, Wei Miao, Qijun Yao +2 more

We report the terahertz direct detection characteristics of a spiral antenna coupled NbN superconducting hot-electron bolometer (HEB) at a bath temperature of 4.2 K. Thermal conductance determined from resistance transition curves with different bias currents is found to be 3 × 10 −7 W/K. The device shows a read-out circuit limited noise equivalent power (NEP) of 4.5 × 10 −12 W/Hz 1/2 at 4.2 K with a home-made transimpedance amplifier operating at room temperature.

Chinese Physics Letters•Jan 1, 2011•14 citations
Abstract Relaxation oscillations related to terahertz (THz) power detection in superconducting niobium nitride hot electron bolometers (HEBs) have been studied using microwaves as a probe. The reflected microwave signal, which is related to the impedance changes of the HEB irradiated by an incident THz signal, can be used to characterize relaxation oscillations. The frequency of relaxation oscillation switching between the superconducting and resistive states increases linearly with incident THz power but nonlinearly with bias voltage or bath temperature. The observed strong periodic pulse trains of relaxation oscillations have a maximum duty cycle of ∼50%. These strong switching pulses indicate that DC Joule heating, THz radiation or thermal energy is absorbed in the bi-stable region of the HEB intermittently. In addition to relaxation oscillations, we also see weaker oscillations when the device is in the resistive state, which we call intrinsic oscillations. These have a constant frequency at the order of 10 kHz which is independent of external stimuli. The weak periodic pulse trains at a constant frequency can be divided into mainly two types—one is the pulse train with a small duty cycle and the other is the quasi-square wave. Measurement of these oscillations in HEBs has some practical applications. Digital THz power measurement with frequencies below and above the gap frequency can be made based on the linearity between relaxation oscillation frequency and incident THz power. The relaxation oscillation frequency can be used to estimate the maximum speed of a THz direct detection system especially for a multi-pixel HEB array. In particular, extra noise induced by relaxation oscillations and intrinsic oscillations can be determined for the HEB operating as a THz direct detector.
In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.