An ac-Josephson-effect determination of
he with significantly improved accuracy is reported. The precision of the measurement is determined by uncertainties associated with the comparison of a Josephson-device voltage with the emf of an electrochemical-standard-cell voltage reference and is about 3 parts in
108. This precision was made possible by use of Josephson devices at voltages above 10 mV and design and construction of two special voltage-comparator instruments. The fabrication and operation of the Josephson devices and the design and performance of the voltage comparators are discussed. The 3/
108 precision represents the precision with which a drift-free and readily reproducible Josephson voltage standard can be realized in practice using the techniques developed for these experiments. The accuracy of the final result is about 12 parts in
108 and is determined primarily by uncertainties associated with the stability of the local electrochemical voltage standard and with establishment of the relationship between the local volt and the volt maintained by the U. S. National Bureau of Standards. Significant improvements in the maintenance of the local-voltage standard which contributed to reduction of the final uncertainty to this value are discussed. During the course of the experiments, the Josephson frequency-voltage relation was shown experimentally to be independent of magnetic field, temperature, and Josephson-device bias voltage or induced step number to within the accuracy of the final result. The final experimental result and its one-standard-deviation uncertainty are $\frac{2e}{h}=(483.593718\ifmmode\pm\else\textpm\fi{}0.000060)\frac{\mathrm{MHz}}{\ensuremath{\mu}{V}_{\mathrm{NBS}69}}$ (0.12 ppm) referred to the volt as maintained by the U. S. National Bureau of Standards after January 1, 1969. This result is in excellent agreement with the earlier, less accurate result of Parker, Langenberg, Denenstein, and Taylor, which played an important role in the 1969 adjustment of the fundamental physical constants by Taylor, Parker, and Langenberg. It is in reasonable agreement with values recently reported by several other groups. The significantly improved accuracy of the present result makes possible a small improvement in the accuracy of the derived value of the fine structure constant and clears the way for a larger improvement through more accurate determination of the proton gyromagnetic ratio.
We have synthesized and measured ac and dc voltages using a Josephson arbitrary waveform synthesizer. On-chip filtering has enabled the first practical operating margins for ac and arbitrary waveforms. Using a digital voltmeter, we demonstrate the operating margins and linearity of 101 synthesized dc voltages and confirm the flatness of a single voltage step. We present the first ac-dc and ac-ac voltage measurements of the synthesizer at 3.65 mV using an ac-dc thermal transfer standard. This quantum-based standard source can be used to measure the ac-dc difference of thermal transfer standards at small voltages.