Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Josephson devices for ac quantum voltage standard

Paolo Durandetto

Published Jul 1, 2019• 0 citations
OpenAlex

Related papers

Perspective of Realization of a Quantum AC Voltage Standard

Chiharu Urano, Nobu‐Hisa Kaneko, Kiryu Shogo +2 more

IEICE Technical Report; IEICE Tech. Rep.•Jan 20, 2006•0 citations

Pulse-Driven High- TC Josephson Junctions for Quantum Voltage Devices

Adam C. Weis, Nathan E. Flowers-Jacobs, E.Y. Cho +6 more

Josephson junction arrays are the basis for quantum-accurate dc and ac voltage standards, including artificial voltage-noise references used in noise thermometry. I will describe our recent progress towards voltage synthesis using high-transition-temperature YBCO junctions.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2019•0 citations

Josephson Junctions for Programmable and AC Quantum Voltmeters

V. Lacquaniti, Domenico Andreone, Sabino Maggi +4 more

•Jan 1, 2007•0 citations

ac-Josephson-Effect Determination of e h : A Standard of Electrochemical Potential Based on Macroscopic Quantum Phase Coherence in Superconductors

Thomas F. Finnegan, Arnold M. Denenstein, D. N. Langenberg

An ac-Josephson-effect determination of $\frac{e}{h}$ with significantly improved accuracy is reported. The precision of the measurement is determined by uncertainties associated with the comparison of a Josephson-device voltage with the emf of an electrochemical-standard-cell voltage reference and is about 3 parts in ${10}^{8}$. This precision was made possible by use of Josephson devices at voltages above 10 mV and design and construction of two special voltage-comparator instruments. The fabrication and operation of the Josephson devices and the design and performance of the voltage comparators are discussed. The 3/${10}^{8}$ precision represents the precision with which a drift-free and readily reproducible Josephson voltage standard can be realized in practice using the techniques developed for these experiments. The accuracy of the final result is about 12 parts in ${10}^{8}$ and is determined primarily by uncertainties associated with the stability of the local electrochemical voltage standard and with establishment of the relationship between the local volt and the volt maintained by the U. S. National Bureau of Standards. Significant improvements in the maintenance of the local-voltage standard which contributed to reduction of the final uncertainty to this value are discussed. During the course of the experiments, the Josephson frequency-voltage relation was shown experimentally to be independent of magnetic field, temperature, and Josephson-device bias voltage or induced step number to within the accuracy of the final result. The final experimental result and its one-standard-deviation uncertainty are $\frac{2e}{h}=(483.593718\ifmmode\pm\else\textpm\fi{}0.000060)\frac{\mathrm{MHz}}{\ensuremath{\mu}{V}_{\mathrm{NBS}69}}$ (0.12 ppm) referred to the volt as maintained by the U. S. National Bureau of Standards after January 1, 1969. This result is in excellent agreement with the earlier, less accurate result of Parker, Langenberg, Denenstein, and Taylor, which played an important role in the 1969 adjustment of the fundamental physical constants by Taylor, Parker, and Langenberg. It is in reasonable agreement with values recently reported by several other groups. The significantly improved accuracy of the present result makes possible a small improvement in the accuracy of the derived value of the fine structure constant and clears the way for a larger improvement through more accurate determination of the proton gyromagnetic ratio.

Physical review. B, Solid state•Sep 1, 1971•66 citations

Establishing Programmable Josephson Voltage Standard and Maintaining Its Quantum Accuracy

TÜBİTAK Ulusal Metroloji Enstitüsü, P.K. 54, 41470, Gebze-Kocaeli, Turkey, Tezgül Coşkun Öztürk, Sarp Ertürk +4 more

International Journal of Electrical and Electronic Engineering & Telecommunications•Jan 1, 2019•6 citations

AC and DC voltages from a Josephson arbitrary waveform synthesizer

Samuel P. Benz, Charles J. Burroughs, Paul D. Dresselhaus +1 more

We have synthesized and measured ac and dc voltages using a Josephson arbitrary waveform synthesizer. On-chip filtering has enabled the first practical operating margins for ac and arbitrary waveforms. Using a digital voltmeter, we demonstrate the operating margins and linearity of 101 synthesized dc voltages and confirm the flatness of a single voltage step. We present the first ac-dc and ac-ac voltage measurements of the synthesizer at 3.65 mV using an ac-dc thermal transfer standard. This quantum-based standard source can be used to measure the ac-dc difference of thermal transfer standards at small voltages.

IEEE Transactions on Instrumentation and Measurement•Apr 1, 2001•44 citations
An ac-Josephson-effect determination of eh\frac{e}{h}he​ with significantly improved accuracy is reported. The precision of the measurement is determined by uncertainties associated with the comparison of a Josephson-device voltage with the emf of an electrochemical-standard-cell voltage reference and is about 3 parts in 108{10}^{8}108. This precision was made possible by use of Josephson devices at voltages above 10 mV and design and construction of two special voltage-comparator instruments. The fabrication and operation of the Josephson devices and the design and performance of the voltage comparators are discussed. The 3/108{10}^{8}108 precision represents the precision with which a drift-free and readily reproducible Josephson voltage standard can be realized in practice using the techniques developed for these experiments. The accuracy of the final result is about 12 parts in 108{10}^{8}108 and is determined primarily by uncertainties associated with the stability of the local electrochemical voltage standard and with establishment of the relationship between the local volt and the volt maintained by the U. S. National Bureau of Standards. Significant improvements in the maintenance of the local-voltage standard which contributed to reduction of the final uncertainty to this value are discussed. During the course of the experiments, the Josephson frequency-voltage relation was shown experimentally to be independent of magnetic field, temperature, and Josephson-device bias voltage or induced step number to within the accuracy of the final result. The final experimental result and its one-standard-deviation uncertainty are $\frac{2e}{h}=(483.593718\ifmmode\pm\else\textpm\fi{}0.000060)\frac{\mathrm{MHz}}{\ensuremath{\mu}{V}_{\mathrm{NBS}69}}$ (0.12 ppm) referred to the volt as maintained by the U. S. National Bureau of Standards after January 1, 1969. This result is in excellent agreement with the earlier, less accurate result of Parker, Langenberg, Denenstein, and Taylor, which played an important role in the 1969 adjustment of the fundamental physical constants by Taylor, Parker, and Langenberg. It is in reasonable agreement with values recently reported by several other groups. The significantly improved accuracy of the present result makes possible a small improvement in the accuracy of the derived value of the fine structure constant and clears the way for a larger improvement through more accurate determination of the proton gyromagnetic ratio.
We have synthesized and measured ac and dc voltages using a Josephson arbitrary waveform synthesizer. On-chip filtering has enabled the first practical operating margins for ac and arbitrary waveforms. Using a digital voltmeter, we demonstrate the operating margins and linearity of 101 synthesized dc voltages and confirm the flatness of a single voltage step. We present the first ac-dc and ac-ac voltage measurements of the synthesizer at 3.65 mV using an ac-dc thermal transfer standard. This quantum-based standard source can be used to measure the ac-dc difference of thermal transfer standards at small voltages.