Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Robust Gauge Reduction under Imperfect Quantum Controls

Oliver Tuma

Published Sep 29, 2026• 0 citations
Publisher

Abstract

This is a separate preprint record that develops the robustness layer of the outcome-resolved mid-circuit-measurement gauge analysis. It uses the exact complete-positivity benchmark of the preceding preprint as an input, but its main result concerns the composition of imperfect-control uncertainty, residual-gauge conditioning, and instrument-model error. The general ingredients—gate-set-tomography gauge freedom, commutant geometry, perturbation by singular-value gaps, quantum-instrument physicality, and mid-circuit-measurement learnability—are prior art. The paper does not claim a new general GST gauge principle, a dimension-free tomography theorem, or experimental validation. Related identifier ● Identifier: 10.5281/zenodo.23043202 ● Relation: Is derived from (isDerivedFrom) ● Resource type: Publication -> Preprint ● Title: Outcome-Resolved Mid-Circuit Measurements as Exact Gauge Constraints: Complete-Positivity Windows, Correlation Certificates, and Robustness Limits Description / Abstract Self-consistent quantum characterization is invariant under similarity transformations, so an experimentally fitted gate set is generally identified only up to gauge. Exact trusted controls can reduce this ambiguity, but realistic controls are imperfect; simultaneously, a mid-circuit measurement (MCM) instrument is itself only approximately described by a model. These two uncertainties act at different logical stages and should not be merged before the gauge geometry is reconstructed. This preprint gives an explicit finite-dimensional stability analysis. For a finite reference control family ({R_i}), define the commutator map (\mathcal C(B)=([B,R_i])_i) and let (\gamma) be its smallest positive singular value. If two exactly gauge-equivalent implemented gate families ({G_i}) and ({G’_i}) both lie within Frobenius errors (\delta_i) of the same references, then every trace-preserving gauge matrix (B) lies within [\operatorname{dist}{F}(B,\ker\mathcal C)\le \frac{2\Delta}{\gamma}|B|{\mathrm{op}},\qquad\Delta=\left(\sum_i\delta_i^2\right)^{1/2}.] For the two-qubit control set (H\otimes I), (S\otimes I), (I\otimes H), (I\otimes S), and CNOT, the exact commutant is (\operatorname{span}{\mathcal D,\mathrm{id}-\mathcal D}), so the residual scalar gauge is (B_c=\mathcal D+c(\mathrm{id}-\mathcal D)). In the declared unweighted Frobenius convention, direct computation gives (\gamma=0.830129650657\ldots). The main result closes two previously separate robustness budgets. Suppose an independent physical or calibration argument places the scalar projection (c) in a positive prior interval ([\ell,u]). If (\alpha=2\Delta/\gamma<1), a self-normalized estimate removes the otherwise unknown factor (|B|): [|B-B_c|_F\le \bar e=\frac{\alpha M_0}{1-\alpha},\qquad M_0=\max(1,u).] If (\bar e<m_0=\min(1,\ell)), the condition number of (B) is explicitly bounded. Composing this control-side bound with a Choi-Frobenius instrument-model error (\varepsilon) yields a closed outer complete-positivity condition for the symmetric noisy Lüders MCM benchmark, [(1-\eta)|1-2p|,|c-c^{-1}|\le \eta+2d\rho,] where (\rho) is an explicit function of (\Delta,\gamma,\ell,u), and (\varepsilon). Hence the imperfect-control problem again reduces to an explicit scalar gauge interval. The result separates transverse control uncertainty from instrument-model uncertainty and identifies the loss of robustness as the prior gauge envelope approaches singularity.

DOI
10.5281/zenodo.23043721

Related papers

Detailed, interpretable characterization of mid-circuit measurement on a transmon qubit

Piper C. Wysocki, Luke D. Burkhart, Madeline H. Morocco +12 more

Mid-circuit measurements (MCMs) are critical components of the quantum error correction protocols expected to enable utility-scale quantum computing. MCMs can be modeled by quantum instruments (a type of quantum operation or process), which can be characterized self-consistently using gate set tomography. However, experimentally estimated quantum instruments are often hard to interpret or relate to device physics. We address this challenge by adapting the error generator formalism -- previously used to interpret noisy quantum gates by decomposing their error processes into physically meaningful sums of "elementary errors" -- to MCMs. We deploy our new analysis on a transmon qubit device to tease out and quantify error mechanisms including amplitude damping, readout error, and imperfect collapse. We examine in detail how the magnitudes of these errors vary with the readout pulse amplitude, recover the key features of dispersive readout predicted by theory, and show that these features can be modeled parsimoniously using a reduced model with just a few parameters.

quant-pharXiv:2602.03938•Feb 5, 2026•4 citations

Outcome-Resolved Mid-Circuit Measurements as Exact Gauge Constraints

Oliver Tuma

Self-consistent quantum tomography is invariant under similarity transformations that can leave all observed circuit probabilities unchanged. Mid-circuit measurements (MCMs) add a qualitatively different object to this problem: an outcome-resolved quantum instrument has both a classical label and a post-measurement quantum state, so each outcome branch must itself remain completely positive under any admissible representation change. We study an exactly solvable residual-gauge model in even dimension d = 2r ≥ 4. After a fixed two-qubit Clifford control set reduces the trace-preserving similarity freedom to the scalar family B_c = D + c(id − D), we consider a symmetric two-sector Lüders instrument with label-confusion probability p and isotropic state-and-label replacement probability η. For the transformed branches J_{s,c} = B_c J_s^{η,p} B_c^{-1}, we prove exact necessary-and-sufficient complete-positivity criteria for both positive and negative scalar gauges. For c > 0 the condition is (1 − η)|1 − 2p||c − c^{-1}| ≤ η, while for c < 0 it is (1 − η)|1 − 2p|(|c| + 2 + |c|^{-1}) ≤ η. The result follows from an explicit Choi-spectrum calculation. It yields a closed positive gauge interval, an exact threshold for the appearance of negative gauges, and a logarithmic gauge radius |log c| ≤ arsinh(K/2), with K = η/[(1 − η)|1 − 2p|]. If the outcome label is discarded, the averaged channel is invariant under every B_c, so the additional gauge information disappears exactly. Two lag correlations determine K within the assumed model and therefore give an observable conditional gauge interval; a Hoeffding bound gives a finite-sample outer interval. We also derive an explicit outer interval when each instrument branch is known only within a Choi-Frobenius error budget. Finally, a Lüders-versus-measure-and-prepare countermodel shows that repeated outcome strings alone do not validate the quantum state continuation. A targeted literature audit finds substantial prior art on gate-set-tomography gauge freedom, instrument tomography, MCM learnability, and gauge-aware physicality intervals, including a closely related 2026 three-measurement protocol. The contribution is therefore deliberately narrow: the exact higher-dimensional full-complete-positivity boundary for the stated instrument family and its derived consequences, not the general idea that physicality can restrict tomography gauge.

•Sep 29, 2026•0 citations

Quantum Measurement under AASC

Amos Jay Maley Maley

Physical Sources, Finite Detectors, Persistent Records, and Actual Events This paper develops a unified account of quantum measurement under the Admissibility and Standing Constraint (AASC) framework, connecting constructed physical sources, quantum instruments, material amplification, finite record retention, event probabilities, and the actuality of measurement outcomes. The paper distinguishes three separate objects: a complete quantum instrument containing all outcome operations, including unresolved and failed outcomes; a material record carried by a physical system whose acquisition and retention can be analyzed; an actual history describing which occurrences belong to one original experimental run. A complete instrument and a persistent material record can be constructed without assuming that linear quantum dynamics alone selects one globally definite original-run history. Conversely, the admission of an actual event does not by itself determine its probability law or conditional quantum state. The physical construction contains two complementary measurement targets: a regulated interacting gauge–Higgs–fermion source with its full source Hamiltonian retained during finite receiver pulses; an explicitly parameterized six-mode cosine circuit with source and pump interfaces, losses, distinguishable outputs, a two-polarization intrinsic-spin receiver, and a finite energy-resolving thermal amplifier. The material-registration chain includes source-code loading, driven conversion, output registration, pump-displacement removal, transfer to an intrinsic material spin, finite Gibbs-collision amplification, endpoint reading, and quiet record retention. Electronic display labels, material flags, missed counts, dark displays, blanks, and unreadable outcomes remain distinct and are retained in the joint error ledger. The paper establishes: informative bounded receivers on an interacting quantum source; finite-pulse calibration with the complete source Hamiltonian retained; a complete monitored detector model; finite preparation and amplification bounds; coherent composition of instruments and records; adaptive record composition; local-instrument compatibility; calibrated affine probability uniqueness; sharp coherent calibration limits; sequential probability laws and compatible conditional states; explicit actual-history requirements. A finite Fourier residual certificate bounds the complete monitored detector instrument over its full \(35.587\ \mathrm{ms}\) interval by \(0.063241\) in restricted diamond norm. Exact interval arithmetic gives seeded amplifier endpoint fidelity greater than \(0.9999235242\) after 1,024 finite collisions, together with an explicit conditional survival bound for a subsequent \(100\ \mathrm{ms}\) quiet hold. The probability analysis shows that positivity, density-operator dependence, affinity under classical mixtures, and calibration fix the trace probability rule for the declared readout. Approximate sector calibration alone permits coherent deviations of order the square root of the calibration error; stronger linear bounds require additional structure. The paper’s central measurement-theoretic conclusion is deliberately separated from its successful detector construction. A complete instrument admits an exclusive-history completion, but linear quantum dynamics alone does not select one such history. Source-specific preparation, reader analysis, and a bounded counting-law completion supply the additional physical input required to select an actual history. The resulting framework substantially develops the material and probabilistic parts of quantum measurement while isolating apparatus errors, actual-history law, and event-selection assumptions as explicit obligations. The work does not claim to solve every interpretation of the measurement problem, derive a universal collapse law, establish unrestricted detector accuracy, or identify a finite calibration certificate with an experimental calibration. Principal contributions A unified source-to-detector account of quantum measurement. Constructed interacting quantum sources with finite receivers. Six-mode cosine-circuit detector realization. Material registration and finite amplification chain. Two-polarization intrinsic-spin receiver. Finite thermal collision and endpoint-reading model. Full-duration restricted diamond-norm detector bound. Interval-certified amplifier fidelity. Conditional quiet-hold survival bound. Retention of blanks, wrong, unreadable, and missed outcomes. Calibrated affine probability uniqueness. Sequential instruments and compatible conditional states. Explicit separation of complete instruments, material records, and actual histories. Source-specific conditions for actual-event selection. Complete physical error and assumption ledger.

•Sep 10, 2026•0 citations

Information Limits of Outcome-Resolved Incidence Certification

Qingchun Zhang

Calibrated support observations can constrain a complete quantum instrument without identifying its action by unrestricted tomography. We study what those observations guarantee when the noise law is not supplied. On a fixed four-dimensional incidence-record experiment, we define the set of all complete two-outcome completely positive instruments compatible with the exact raw rejection and outcome probabilities, retaining the classical flags. Exact ideal data identify the target, but an explicit family of complete instruments reproduces the nonzero-data category laws of a low-error contamination device while admitting coherent error of square-root order. A target-ray mass certificate and a common complete-dilation comparison give a universal upper, while an exactly feasible rational instrument supplies a stronger lower witness. At the diagnostic parameter r = 1/300000000, the unhalved target-relative worst-case radius lies between 0.000258065115532250 and 0.000951566242566. The result separates avoidable inequality conservatism from information absent from the measured data. Fixed-functional and fixed-map optimizations have separately certified scopes; they do not solve the global radius. The conclusions are conditional on the supplied carrier, calibration and common-device model. They do not establish an apparatus, device-independent certification, a finite-sample power guarantee or complete formal verification. Selected supporting declarations have one recorded successful Lean 4.19.0 macOS execution and declaration-specific source, type and axiom review; this is not an end-to-end formalization.

•Oct 13, 2026•0 citations

Relational Anchors for Quantum Subsystem Identification: Quadratic Obstructions, Cubic Gauge Collapse, and Robust Rigidity

Oliver Tuma

This preprint develops a finite-dimensional, proof-audited route from noisy relational localization certificates to exact tensor-product-structure (TPS) envelopes and robust subsystem identification. It separates the pre-Jordan gauge-calibration problem from the post-calibration algebra-rounding problem, proves a quadratic non-identifiability obstruction, and gives a finite cubic relation criterion for Wigner/Jordan gauge collapse. The cubic action is quantitatively analyzed through an exact transverse singular-value identity, nonlinear geodesic bounds, spectral recovery of the Wigner derivation algebra, a two-qubit Pfaffian model, and structured far-sector certificates. For two qubits, the derivation-normalizer problem is reduced to a quartic Grassmann objective and then closed analytically by an explicit Chevalley–Eilenberg/Hodge coercivity estimate on the 90-dimensional normal SU(4) module. This yields a rigorous global entry bound beta_4(pi/(2 sqrt(2))) > sqrt(2/37) and an unconditional cubic-to-Wigner threshold Delta_3^0 < 4/(3 sqrt(185)), eliminating the previous global far-region certification gate in this dimension. The post-calibration branch proves exact Wedderburn articulation for bistochastic idempotent anchors, Choi-rank and Choi-spectrum diagnostics, a central-derivation factor certificate, complementary-factor rectification, complete rounding-set ambiguity control, and stabilizer-synchronized relational-anchor separation. The resulting theorem is a conditional, radius-valued robustness statement inside a finite-dimensional full matrix algebra; it does not claim raw-frequency sample complexity, a dimension-free algebra-rounding constant, or preferred subsystems from a Hamiltonian and state alone.

•Sep 5, 2026•0 citations

From Predictive to Descriptive Completeness: Phase-Resolved Quantum Measurement in Circuit QED

Manoj Atolia

The quantum formalism contains a structural discrepancy: the transition amplitude computes the interaction-specific relative phase between probe and target and its effect on coupling strength, while the post-interaction state description does not preserve it. A companion paper identified this discrepancy and argued that the measurement problem arises from mistaking the formalism’s predictive completeness for descriptive completeness at the level of individual events. The present paper develops the quantitative consequence. A minimal phenomenological model shows that, for an event-level conditional law of the stated phase-dependent form, uniform averaging over the interaction-relative phase recovers the Born rule exactly, while partial phase control narrows the outcome distribution according to a visibility-loss factor . Starting from the Jaynes-Cummings Hamiltonian for a two-level system coupled to a single-mode field, we derive the event-level conditional probability , where is the phase-coupling strength — a quantity determined by the microscopic interaction parameters. The phase-coupling strength has two contributions. A pointer-overlap term, , arises from the finite separation of the measurement pointer states and decays exponentially with measurement strength . A persistent term, , arises from beyond-dispersive corrections to the Jaynes-Cummings dynamics. The standard treatment computes the rate of these transitions by squaring the matrix elements, eliminating the relative phase between qubit and field; the present framework retains the amplitude structure prior to ensemble reduction, predicting that the transitions are phase-correlated with the qubit-field relative phase. We propose a specific experiment: sweeping measurement strength while tracking phase-resolved outcome modulation in a circuit QED system. The standard treatment predicts the modulation amplitude decays to zero; the present framework predicts it saturates at a nonzero floor. Because a small phase-dependent bias can also arise from ordinary measurement non-diagonality, the decisive evidence is not the cosine modulation itself but its parameter dependence: the predicted amplitude must scale as across controlled changes in detuning, reverse under , and persist under recalibration. The experiment is feasible with current technology and would determine whether event-level phase structure persists through the measurement interaction or is genuinely absent from the outcome-producing physics.

•Apr 6, 2026•0 citations
This is a separate preprint record that develops the robustness layer of the outcome-resolved mid-circuit-measurement gauge analysis. It uses the exact complete-positivity benchmark of the preceding preprint as an input, but its main result concerns the composition of imperfect-control uncertainty, residual-gauge conditioning, and instrument-model error. The general ingredients—gate-set-tomography gauge freedom, commutant geometry, perturbation by singular-value gaps, quantum-instrument physicality, and mid-circuit-measurement learnability—are prior art. The paper does not claim a new general GST gauge principle, a dimension-free tomography theorem, or experimental validation. Related identifier ● Identifier: 10.5281/zenodo.23043202 ● Relation: Is derived from (isDerivedFrom) ● Resource type: Publication -> Preprint ● Title: Outcome-Resolved Mid-Circuit Measurements as Exact Gauge Constraints: Complete-Positivity Windows, Correlation Certificates, and Robustness Limits Description / Abstract Self-consistent quantum characterization is invariant under similarity transformations, so an experimentally fitted gate set is generally identified only up to gauge. Exact trusted controls can reduce this ambiguity, but realistic controls are imperfect; simultaneously, a mid-circuit measurement (MCM) instrument is itself only approximately described by a model. These two uncertainties act at different logical stages and should not be merged before the gauge geometry is reconstructed. This preprint gives an explicit finite-dimensional stability analysis. For a finite reference control family ({R_i}), define the commutator map (\mathcal C(B)=([B,R_i])_i) and let (\gamma) be its smallest positive singular value. If two exactly gauge-equivalent implemented gate families ({G_i}) and ({G’_i}) both lie within Frobenius errors (\delta_i) of the same references, then every trace-preserving gauge matrix (B) lies within [\operatorname{dist}{F}(B,\ker\mathcal C)\le \frac{2\Delta}{\gamma}|B|{\mathrm{op}},\qquad\Delta=\left(\sum_i\delta_i^2\right)^{1/2}.] For the two-qubit control set (H\otimes I), (S\otimes I), (I\otimes H), (I\otimes S), and CNOT, the exact commutant is (\operatorname{span}{\mathcal D,\mathrm{id}-\mathcal D}), so the residual scalar gauge is (B_c=\mathcal D+c(\mathrm{id}-\mathcal D)). In the declared unweighted Frobenius convention, direct computation gives (\gamma=0.830129650657\ldots). The main result closes two previously separate robustness budgets. Suppose an independent physical or calibration argument places the scalar projection (c) in a positive prior interval ([\ell,u]). If (\alpha=2\Delta/\gamma<1), a self-normalized estimate removes the otherwise unknown factor (|B|): [|B-B_c|_F\le \bar e=\frac{\alpha M_0}{1-\alpha},\qquad M_0=\max(1,u).] If (\bar e<m_0=\min(1,\ell)), the condition number of (B) is explicitly bounded. Composing this control-side bound with a Choi-Frobenius instrument-model error (\varepsilon) yields a closed outer complete-positivity condition for the symmetric noisy Lüders MCM benchmark, [(1-\eta)|1-2p|,|c-c^{-1}|\le \eta+2d\rho,] where (\rho) is an explicit function of (\Delta,\gamma,\ell,u), and (\varepsilon). Hence the imperfect-control problem again reduces to an explicit scalar gauge interval. The result separates transverse control uncertainty from instrument-model uncertainty and identifies the loss of robustness as the prior gauge envelope approaches singularity.
Mid-circuit measurements (MCMs) are critical components of the quantum error correction protocols expected to enable utility-scale quantum computing. MCMs can be modeled by quantum instruments (a type of quantum operation or process), which can be characterized self-consistently using gate set tomography. However, experimentally estimated quantum instruments are often hard to interpret or relate to device physics. We address this challenge by adapting the error generator formalism -- previously used to interpret noisy quantum gates by decomposing their error processes into physically meaningful sums of "elementary errors" -- to MCMs. We deploy our new analysis on a transmon qubit device to tease out and quantify error mechanisms including amplitude damping, readout error, and imperfect collapse. We examine in detail how the magnitudes of these errors vary with the readout pulse amplitude, recover the key features of dispersive readout predicted by theory, and show that these features can be modeled parsimoniously using a reduced model with just a few parameters.
Self-consistent quantum tomography is invariant under similarity transformations that can leave all observed circuit probabilities unchanged. Mid-circuit measurements (MCMs) add a qualitatively different object to this problem: an outcome-resolved quantum instrument has both a classical label and a post-measurement quantum state, so each outcome branch must itself remain completely positive under any admissible representation change. We study an exactly solvable residual-gauge model in even dimension d = 2r ≥ 4. After a fixed two-qubit Clifford control set reduces the trace-preserving similarity freedom to the scalar family B_c = D + c(id − D), we consider a symmetric two-sector Lüders instrument with label-confusion probability p and isotropic state-and-label replacement probability η. For the transformed branches J_{s,c} = B_c J_s^{η,p} B_c^{-1}, we prove exact necessary-and-sufficient complete-positivity criteria for both positive and negative scalar gauges. For c > 0 the condition is (1 − η)|1 − 2p||c − c^{-1}| ≤ η, while for c < 0 it is (1 − η)|1 − 2p|(|c| + 2 + |c|^{-1}) ≤ η. The result follows from an explicit Choi-spectrum calculation. It yields a closed positive gauge interval, an exact threshold for the appearance of negative gauges, and a logarithmic gauge radius |log c| ≤ arsinh(K/2), with K = η/[(1 − η)|1 − 2p|]. If the outcome label is discarded, the averaged channel is invariant under every B_c, so the additional gauge information disappears exactly. Two lag correlations determine K within the assumed model and therefore give an observable conditional gauge interval; a Hoeffding bound gives a finite-sample outer interval. We also derive an explicit outer interval when each instrument branch is known only within a Choi-Frobenius error budget. Finally, a Lüders-versus-measure-and-prepare countermodel shows that repeated outcome strings alone do not validate the quantum state continuation. A targeted literature audit finds substantial prior art on gate-set-tomography gauge freedom, instrument tomography, MCM learnability, and gauge-aware physicality intervals, including a closely related 2026 three-measurement protocol. The contribution is therefore deliberately narrow: the exact higher-dimensional full-complete-positivity boundary for the stated instrument family and its derived consequences, not the general idea that physicality can restrict tomography gauge.
Physical Sources, Finite Detectors, Persistent Records, and Actual Events This paper develops a unified account of quantum measurement under the Admissibility and Standing Constraint (AASC) framework, connecting constructed physical sources, quantum instruments, material amplification, finite record retention, event probabilities, and the actuality of measurement outcomes. The paper distinguishes three separate objects: a complete quantum instrument containing all outcome operations, including unresolved and failed outcomes; a material record carried by a physical system whose acquisition and retention can be analyzed; an actual history describing which occurrences belong to one original experimental run. A complete instrument and a persistent material record can be constructed without assuming that linear quantum dynamics alone selects one globally definite original-run history. Conversely, the admission of an actual event does not by itself determine its probability law or conditional quantum state. The physical construction contains two complementary measurement targets: a regulated interacting gauge–Higgs–fermion source with its full source Hamiltonian retained during finite receiver pulses; an explicitly parameterized six-mode cosine circuit with source and pump interfaces, losses, distinguishable outputs, a two-polarization intrinsic-spin receiver, and a finite energy-resolving thermal amplifier. The material-registration chain includes source-code loading, driven conversion, output registration, pump-displacement removal, transfer to an intrinsic material spin, finite Gibbs-collision amplification, endpoint reading, and quiet record retention. Electronic display labels, material flags, missed counts, dark displays, blanks, and unreadable outcomes remain distinct and are retained in the joint error ledger. The paper establishes: informative bounded receivers on an interacting quantum source; finite-pulse calibration with the complete source Hamiltonian retained; a complete monitored detector model; finite preparation and amplification bounds; coherent composition of instruments and records; adaptive record composition; local-instrument compatibility; calibrated affine probability uniqueness; sharp coherent calibration limits; sequential probability laws and compatible conditional states; explicit actual-history requirements. A finite Fourier residual certificate bounds the complete monitored detector instrument over its full 35.587 ms35.587\ \mathrm{ms}35.587 ms interval by 0.0632410.0632410.063241 in restricted diamond norm. Exact interval arithmetic gives seeded amplifier endpoint fidelity greater than 0.99992352420.99992352420.9999235242 after 1,024 finite collisions, together with an explicit conditional survival bound for a subsequent 100 ms100\ \mathrm{ms}100 ms quiet hold. The probability analysis shows that positivity, density-operator dependence, affinity under classical mixtures, and calibration fix the trace probability rule for the declared readout. Approximate sector calibration alone permits coherent deviations of order the square root of the calibration error; stronger linear bounds require additional structure. The paper’s central measurement-theoretic conclusion is deliberately separated from its successful detector construction. A complete instrument admits an exclusive-history completion, but linear quantum dynamics alone does not select one such history. Source-specific preparation, reader analysis, and a bounded counting-law completion supply the additional physical input required to select an actual history. The resulting framework substantially develops the material and probabilistic parts of quantum measurement while isolating apparatus errors, actual-history law, and event-selection assumptions as explicit obligations. The work does not claim to solve every interpretation of the measurement problem, derive a universal collapse law, establish unrestricted detector accuracy, or identify a finite calibration certificate with an experimental calibration. Principal contributions A unified source-to-detector account of quantum measurement. Constructed interacting quantum sources with finite receivers. Six-mode cosine-circuit detector realization. Material registration and finite amplification chain. Two-polarization intrinsic-spin receiver. Finite thermal collision and endpoint-reading model. Full-duration restricted diamond-norm detector bound. Interval-certified amplifier fidelity. Conditional quiet-hold survival bound. Retention of blanks, wrong, unreadable, and missed outcomes. Calibrated affine probability uniqueness. Sequential instruments and compatible conditional states. Explicit separation of complete instruments, material records, and actual histories. Source-specific conditions for actual-event selection. Complete physical error and assumption ledger.
Calibrated support observations can constrain a complete quantum instrument without identifying its action by unrestricted tomography. We study what those observations guarantee when the noise law is not supplied. On a fixed four-dimensional incidence-record experiment, we define the set of all complete two-outcome completely positive instruments compatible with the exact raw rejection and outcome probabilities, retaining the classical flags. Exact ideal data identify the target, but an explicit family of complete instruments reproduces the nonzero-data category laws of a low-error contamination device while admitting coherent error of square-root order. A target-ray mass certificate and a common complete-dilation comparison give a universal upper, while an exactly feasible rational instrument supplies a stronger lower witness. At the diagnostic parameter r = 1/300000000, the unhalved target-relative worst-case radius lies between 0.000258065115532250 and 0.000951566242566. The result separates avoidable inequality conservatism from information absent from the measured data. Fixed-functional and fixed-map optimizations have separately certified scopes; they do not solve the global radius. The conclusions are conditional on the supplied carrier, calibration and common-device model. They do not establish an apparatus, device-independent certification, a finite-sample power guarantee or complete formal verification. Selected supporting declarations have one recorded successful Lean 4.19.0 macOS execution and declaration-specific source, type and axiom review; this is not an end-to-end formalization.
This preprint develops a finite-dimensional, proof-audited route from noisy relational localization certificates to exact tensor-product-structure (TPS) envelopes and robust subsystem identification. It separates the pre-Jordan gauge-calibration problem from the post-calibration algebra-rounding problem, proves a quadratic non-identifiability obstruction, and gives a finite cubic relation criterion for Wigner/Jordan gauge collapse. The cubic action is quantitatively analyzed through an exact transverse singular-value identity, nonlinear geodesic bounds, spectral recovery of the Wigner derivation algebra, a two-qubit Pfaffian model, and structured far-sector certificates. For two qubits, the derivation-normalizer problem is reduced to a quartic Grassmann objective and then closed analytically by an explicit Chevalley–Eilenberg/Hodge coercivity estimate on the 90-dimensional normal SU(4) module. This yields a rigorous global entry bound beta_4(pi/(2 sqrt(2))) > sqrt(2/37) and an unconditional cubic-to-Wigner threshold Delta_3^0 < 4/(3 sqrt(185)), eliminating the previous global far-region certification gate in this dimension. The post-calibration branch proves exact Wedderburn articulation for bistochastic idempotent anchors, Choi-rank and Choi-spectrum diagnostics, a central-derivation factor certificate, complementary-factor rectification, complete rounding-set ambiguity control, and stabilizer-synchronized relational-anchor separation. The resulting theorem is a conditional, radius-valued robustness statement inside a finite-dimensional full matrix algebra; it does not claim raw-frequency sample complexity, a dimension-free algebra-rounding constant, or preferred subsystems from a Hamiltonian and state alone.
The quantum formalism contains a structural discrepancy: the transition amplitude computes the interaction-specific relative phase between probe and target and its effect on coupling strength, while the post-interaction state description does not preserve it. A companion paper identified this discrepancy and argued that the measurement problem arises from mistaking the formalism’s predictive completeness for descriptive completeness at the level of individual events. The present paper develops the quantitative consequence. A minimal phenomenological model shows that, for an event-level conditional law of the stated phase-dependent form, uniform averaging over the interaction-relative phase recovers the Born rule exactly, while partial phase control narrows the outcome distribution according to a visibility-loss factor . Starting from the Jaynes-Cummings Hamiltonian for a two-level system coupled to a single-mode field, we derive the event-level conditional probability , where is the phase-coupling strength — a quantity determined by the microscopic interaction parameters. The phase-coupling strength has two contributions. A pointer-overlap term, , arises from the finite separation of the measurement pointer states and decays exponentially with measurement strength . A persistent term, , arises from beyond-dispersive corrections to the Jaynes-Cummings dynamics. The standard treatment computes the rate of these transitions by squaring the matrix elements, eliminating the relative phase between qubit and field; the present framework retains the amplitude structure prior to ensemble reduction, predicting that the transitions are phase-correlated with the qubit-field relative phase. We propose a specific experiment: sweeping measurement strength while tracking phase-resolved outcome modulation in a circuit QED system. The standard treatment predicts the modulation amplitude decays to zero; the present framework predicts it saturates at a nonzero floor. Because a small phase-dependent bias can also arise from ordinary measurement non-diagonality, the decisive evidence is not the cosine modulation itself but its parameter dependence: the predicted amplitude must scale as across controlled changes in detuning, reverse under , and persist under recalibration. The experiment is feasible with current technology and would determine whether event-level phase structure persists through the measurement interaction or is genuinely absent from the outcome-producing physics.