Classifying malaria cell images relies on examining blood-smear microscopy slides to separate healthy red blood cells from those carrying the parasite to recognize the stage of infection. Manually examining the cells under a microscope is slow, as it depends heavily on expert skill, and can lead to inconsistent results, especially in resource-limited settings. Machine learning and deep learning help overcome these difficulties by automatically detecting subtle patterns that are hard for the human eye to distinguish, enabling faster, more accurate, and scalable diagnosis. This work compares the performance of classical deep learning models and hybrid quantum-classical systems for malaria cell classification problem, for a publicly available Kaggle dataset of 27,558 labelled images. The pipeline combines classical feature extraction from a subset of 5000 images with quantum feature mapping and variational quantum circuits (2, 3 and 4 qubits) through angle encoding and strongly entangling layers. All the models have been trained over 40 epochs with a 70-15-15 train-validation-test split, and accuracy, precision, recall, and F1-score have been evaluated. Classical CNN achieved 92.93% accuracy, while ResNet18 and MobileNetV2 achieved 87.87% and 60.67 % respectively.4-qubit Quantum CNN achieves the highest score of 93.47%, surpassing all the classical baselines. The hybrid MobileNetV2 achieved an accuracy of 87.07%, which is a significant improvement compared with its classical counterpart, indicating that quantum feature transformation can repurpose weak classical representations.
Classifying malaria cell images relies on examining blood-smear microscopy slides to separate healthy red blood cells from those carrying the parasite to recognize the stage of infection. Manually examining the cells under a microscope is slow, as it depends heavily on expert skill, and can lead to inconsistent results, especially in resource-limited settings. Machine learning and deep learning help overcome these difficulties by automatically detecting subtle patterns that are hard for the human eye to distinguish, enabling faster, more accurate, and scalable diagnosis. This work compares the performance of classical deep learning models and hybrid quantum-classical systems for malaria cell classification problem, for a publicly available Kaggle dataset of 27,558 labelled images. The pipeline combines classical feature extraction from a subset of 5000 images with quantum feature mapping and variational quantum circuits (2, 3 and 4 qubits) through angle encoding and strongly entangling layers. All the models have been trained over 40 epochs with a 70-15-15 train-validation-test split, and accuracy, precision, recall, and F1-score have been evaluated. Classical CNN achieved 92.93% accuracy, while ResNet18 and MobileNetV2 achieved 87.87% and 60.67 % respectively.4-qubit Quantum CNN achieves the highest score of 93.47%, surpassing all the classical baselines. The hybrid MobileNetV2 achieved an accuracy of 87.07%, which is a significant improvement compared with its classical counterpart, indicating that quantum feature transformation can repurpose weak classical representations.
Accurate classification of microscopic blood cells is still a critical task in medical image analysis, where subtle variations and limited data can challenge conventional deep learning models. As such, we investigate in this work the potential of Hybrid Quantum-Classical Neural Networks (HQNNs) to enhance feature representation and improve classification performance in this domain. We propose a modular architecture combining a pre-trained ResNet-50 backbone with a low-dimensional latent bottleneck and a variational quantum circuit, enabling a direct comparison between quantum-enhanced and purely classical transformation mechanisms. To isolate the contribution of the quantum component, we evaluate three architectures: a HQNN model, a Classical Matched Model with an additional nonlinear transformation layer of comparable capacity, and a baseline model without an intermediate transformation stage. Experiments conducted on two publicly available blood cell datasets, namely the Blood Cell Images dataset and the PBC dataset, demonstrate that HQNNs consistently achieve superior or more balanced performance across evaluation metrics. In the Blood Cell Images Dataset, the proposed approach improves macro F1-score by up to 3.7% compared to classical baselines, while improving the F1-score from 98.54% to 98.69% in the more challenging 8-class scenario with near-saturated performance. Additional evaluation on IBM quantum hardware shows that the model remains robust under noise, with only a modest performance degradation relative to simulated results. These results indicate that quantum feature transformations can enhance discriminative representations, particularly in challenging classification scenarios, and highlight the practical potential of HQNN models for medical imaging tasks.
Accurate classification of blood cells is crucial for early diagnosis and monitoring of hematological disorders. However, manual microscopy is time-consuming, subjective, and prone to inter-observer variability. Deep learning has shown potential in automating this task, but its high computational demands limit its use in resource-constrained settings. This study aims to develop an efficient, hybrid quantum-classical model for blood cell classification using quantum simulation to reduce computational complexity without compromising accuracy. We propose a hybrid framework that integrates a 6-qubit variational quantum circuit (VQC) with a classical EfficientNet-B0 model. The model was trained and tested on the full BloodMNIST dataset, which includes 17,092 microscopic images across eight blood cell types. The proposed model achieved a test accuracy of 96.58% and a validation accuracy of 96.90%. F1-scores ranged from 91.97% to 99.84%, with notable results in neutrophils (98.80%) and lymphocytes (98.36%). These findings confirm the feasibility of combining quantum and classical approaches for medical image classification. The proposed hybrid model shows strong promise for practical use in diagnostic systems, especially in low-resource settings, and offers a pathway for future research in quantum-enhanced medical imaging.
One of the most deadly infectious diseases in the world, malaria claims thousands of lives annually, particularly in youngsters. Conventional diagnostic methods including antigen testing, PCR, and microscopic blood smear analysis are either expensive, require specialised labour, or have poor accuracy. We suggest a quantum-inspired method for automated red blood cell (RBC) image-based malaria diagnosis in order to overcome these difficulties. To detect malaria-infected cells, our approach uses a Variational Quantum Classifier (VQC) that combines quantum feature mapping and classical preprocessing. In order to minimise dimensionality while maintaining important information, features are retrieved using contourlet transforms and contour area detection, and then optimised with minimum redundancy maximum relevance (mRMR). When compared to traditional approaches, VQC achieves greater accuracy in classifying the optimised features. Once the infection has been established, a basic rule-based expert system is also added to identify the type of malaria parasite. In addition to demonstrating the effectiveness of VQC for biomedical applications, this work lays the groundwork for the use of quantum models in actual illness detection.
With millions of medical data being produced daily, it is important to leverage current technology to improve the healthcare system. As traditional deep learning models are unable to effectively handle high-dimensional data, a hybrid classical-quantum approach is used to enhance traditional deep learning algorithms. The hybrid classical-quantum models are built upon the classical deep learning framework with quantum techniques. The classical layers are utilized for feature extraction while the quantum layer is used for computational tasks. This addresses computational limitations and data imbalance challenges in medical image analysis. Transfer learning models, such as ResNet18 and InceptionV3, are used in conjunction with a quantum variational circuit to perform the task. The model is trained on a chest X-ray dataset, which consists of two sets of data: binary and multiclass. The binary dataset consists of Normal and COVID-19 images, while the multiclass dataset has COVID-19, Normal, and Tuberculosis images for classification. PennyLane, as a simulator, has been used to perform quantum computing. The dataset has also been used to train the traditional transfer learning models, pre-trained ResNet18, and their results have been compared. Out of all the models tested, the hybrid classical-quantum model, namely Hybrid ResNet18, performed the best. It achieved an accuracy of 93.22% for the binary classification task and 93.91% for the multiclass classification. The results show that there is a statistically significant improvement in classification accuracy and F1-score of the hybrid approach over the classical transfer learning baselines under a simulation-based environment. This sets the stage for further research on real-world physical quantum hardware. Class imbalance and overlapping predictions have been addressed using methods such as data augmentation and confusion matrix analysis. Thus, quantum machine learning could be used as a vital tool to analyze medical data for better diagnostic results.
Accurate and computationally efficient classification of brain tumors from MRI scans is critical for deployment in resource-constrained clinical settings, where conventional deep CNN architectures-despite achieving strong accuracy-often require large parameter counts that limit scalability. This work proposes a hybrid quantum-classical deep learning framework that combines a classical convolutional feature extractor with a variational quantum circuit (VQC) for multi-class tumor classification. Spatial features extracted by the CNN backbone will be dimensionality-reduced and encoded into quantum states using angle encoding; a parameterized quantum circuit will then process these features in a higher-dimensional Hilbert space, leveraging superposition and entanglement to capture non-linear feature correlations. Measurement outputs from the quantum layer will be passed to a classical fully connected layer for classification into glioma, meningioma, pituitary tumor, and no-tumor categories. The proposed framework will be evaluated on a publicly available benchmark MRI dataset and benchmarked against state-of-the-art classical CNN architectures in terms of accuracy, precision, recall, F1-score, and parameter efficiency. This study aims to demonstrate that quantum-enhanced layers can achieve competitive classification performance while substantially reducing trainable parameters, offering a practical direction for efficient, quantum-assisted medical image analysis.
The problem of classifying brain tumours using magnetic resonance imaging (MRI) is a fundamental one in the field of computeraided diagnosis, since although many commonly employed convolutional neural network (CNN) architectures provide high accuracy they contain a large number of parameters, which has led to a search for more compact network designs. In this paper a hybrid quantum–classical approach is proposed that combines a lightweight CNN feature extractor with a trainable variational quantum circuit (VQC) in order to carry out four-class brain tumour classification. The MRI images are resized to 128 by 128 pixels and then processed by a small three-block CNN that reduces each image to an 8-dimensional feature vector. This vector is put into an 8-qubit quantum register by means of angle embedding and then acted on by a variational circuit composed of strongly entangling layers, by measuring each qubit in the Pauli-Z basis. The quantum features thus obtained are then fed into classical dense layers that categorise the images as glioma, meningioma, pituitary tumour or no tumour. The framework was tested on the Brain Tumor MRI dataset (7,200 images) and compared with a classical CNN baseline that was trained under the same conditions. The hybrid model reached a test accuracy of 76.88%, as compared to 72.31% for the classical baseline an improvement of 4.57 percentage points together with corresponding increases in macro-averaged precision, recall and F1-score. Notably, the hybrid model needed only 72 additional trainable parameters when compared to the classical baseline. The fact that the quantum layer was assessed using a noiseless simulator rather than on actual quantum hardware means that these results should be seen as indicating the feasibility of using compact quantum feature transformations for medical image classification rather than as showing a quantum advantage.