Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

공진기 QED 마이크로레이저에서 만델 Q -0.6의 강한 세기의 비고전광 관측

송영훈

Published Aug 1, 2019• 0 citations
OpenAlex

Abstract

One of the merits of nonclassical light is a reduced photon number variance below the standard quantum limit. Sub-Poissonian field in a cavity can provide a great improvement in quantum precision measurements via cavity-enhanced light-matter interaction. However, a realization of macroscopic sub-Poissonian field with more than 3dB photon number variance reduction has not been realized. In this thesis, we report the observation of more than 4dB steady-state photon number variance reduction below the standard quantum limit using the cavity-QED microlaser operated with hundreds of atoms. For this work, we investigated the effect of detector dead time on the measurement of the second-order correlation function. Based on the result, we invented so-called dead-time-free Mandel Q measurement method. While the mandel Q is kept below -0.5, the mean photon number of the field was scalable up to 600 which is much larger than analogous experimental results in microwave regime. Furthermore, our study proves that sub-Poisson photon statistics is not deteriorated by multi-atom effects with our experimental conditions. To our best knowledge, this is the first experimental confirmation of validity of extending the single atom model to many atom regime. By including cavity damping effect, we derived a more realistic theory which can exactly describe the photon statistics in the microlaser. Our findings establish the milestone of our proposal of an effective pathway to generate quasi-Fock-state lasing at the macroscopic scale.

Related papers

Observation of scalable sub-Poissonian-field lasing in a microlaser

Byoung-moo Ann, Younghoon Song, Junki Kim +2 more

Sub-Poisson field with much reduced fluctuations in a cavity can boost quantum precision measurements via cavity-enhanced light-matter interactions. Strong coupling between an atom and a cavity mode has been utilized to generate highly sub-Poisson fields. However, a macroscopic number of optical intracavity photons with more than 3 dB variance reduction has not been possible. Here, we report sub-Poisson field lasing in a microlaser operating with hundreds of atoms with well-regulated atom-cavity coupling and interaction time. Its photon-number variance was 4 dB below the standard quantum limit while the intracavity mean photon number scalable up to 600. The highly sub-Poisson photon statistics were not deteriorated by simultaneous interaction of a large number of atoms. Our finding suggests an effective pathway to widely scalable near-Fock-state lasing at the macroscopic scale.

arXiv:1906.11019•Scientific Reports•Nov 19, 2019•9 citations

Observation of sub-Poisson Photon Statistics in the Cavity-QED Microlaser

Wonshik Choi, Jai-Hyung Lee, Kyungwon An +3 more

We have measured the second-order correlation function of the cavity-QED microlaser output and observed a transition from photon bunching to antibunching with increasing average number of intracavity atoms. The observed correlation times and the transition from super- to sub-Poisson photon statistics can be well described by gain-loss feedback or enhanced-reduced restoring action against fluctuations in photon number in the context of a quantum microlaser theory and a photon rate equation picture. However, the theory predicts a degree of antibunching several times larger than that observed, which may indicate the inadequacy of its treatment of atomic velocity distributions.

arXiv:quant-ph/0411147•Physical Review Letters•Mar 7, 2006•50 citations

Indirect measurement of three-photon correlation in nonclassical light sources

Byoung-moo Ann, Younghoon Song, Junki Kim +2 more

We observe the three-photon correlation in nonclassical light sources by using an indirect measurement scheme based on the dead-time effect of photon-counting detectors. We first develop a general theory which enables us to extract the three-photon correlation from the two-photon correlation of an arbitrary light source measured with detectors with finite dead times. We then confirm the validity of our measurement scheme in experiments done with a cavity-QED microlaser operating with a large intracavity mean photon number exhibiting both sub- and super-Poissonian photon statistics. The experimental results are in good agreement with the theoretical expectation. Our measurement scheme provides an alternative approach for $N$-photon correlation measurement employing $(N\ensuremath{-}1)$ detectors and thus a reduced measurement time for a given signal-to-noise ratio, compared to the usual scheme requiring $N$ detectors.

arXiv:1608.07915•Physical Review A•Jun 9, 2016•2 citations

The relation between Mandel Q and correlation time in the cavity-QED microlaser

Wonshik Choi, W. Seo, H. -G. Hong +6 more

We have measured second order correlation function in the cavity-QED microlaser. The linear relation between correlation time and Mandel Q was observed and this explains the origin of sub-Poissonan photon statistics.

Frontiers in Optics•Jan 1, 2005•0 citations

Sub-Poissonian photon statistics in the micromaser

János A. Bergou

The author presents a tutorial review of the quantum theory of the micromaser which allows for arbitrary (sub- as well as super-Poissonian) fluctuations of the pumping beam. In conventional reservoir theory the rate of change of the cavity field is a sum of the changes due to separate interaction with the individual reservoirs, i.e. the interactions are uncorrelated. In their approach, which is based on discrete mapping rather than a maser equation, corrections to reservoir theory arise due to correlations between these interactions. The magnitude of these terms is characterized by the quantity p/N ex . Here p, the parameter describing pump beam fluctuations, is the negative of the Mandel Q parameter of the pump beam so that p=1 corresponds to regular pumping, p=0 to Poissonian one and p<0 to super-Poissonian pump beam fluctuations. N ex is the number of atoms passing through the cavity during the lifetime of the intercavity field. The conventional reservoir limit (standard laser theory) is recovered if p=0 and/or N ex is large. In all other cases the interactions with the gain and loss reservoirs are correlated. The author presents analytical results to demonstrate the effect of pump regularity on steady-state problems (photon statistics, mean number of photons and photon number variance) as well as on transient phenomena (correlation function and spectrum). In particular, it is shown that the approach to equilibrium can have non-Markovian character.

Quantum and Semiclassical Optics Journal of the European Optical Society Part B•Jun 1, 1995•5 citations

Multiple Thresholds and Many-Atom Dynamics in the Cavity QED Microlaser

Christopher M. Fang-Yen

This thesis describes a study of a cavity QED microlaser in which many atoms are present simultaneously and atom-cavity interaction is well-defined. The microlaser is found to display multiple thresholds analogous to first-order phase transitions of the cavity field. Hysteresis is observed as a function of atom-cavity detuning and number of atoms. Data is compared with a rate equation model and fully quantized treatment based on micromaser theory. Good agreement between theory and experiment is found when the cavity is resonant with atoms of the most probable velocity, but long lifetimes of metastable states preclude the observation of true steady-state transition points. For nonzero atom-cavity detuning the microlaser displays broadenings and shifts which are not yet well-understood. Quantum trajectory simulations are performed to investigate many-atom and finite transit time effects in the microlaser. We show that over a wide range of parameters the many-atom microlaser scales with the single-atom theory, with a perturbation in the photon statistics due to cavity decay during the atom transit time.

arXiv:physics/0412181•Dec 31, 2004•3 citations
One of the merits of nonclassical light is a reduced photon number variance below the standard quantum limit. Sub-Poissonian field in a cavity can provide a great improvement in quantum precision measurements via cavity-enhanced light-matter interaction. However, a realization of macroscopic sub-Poissonian field with more than 3dB photon number variance reduction has not been realized. In this thesis, we report the observation of more than 4dB steady-state photon number variance reduction below the standard quantum limit using the cavity-QED microlaser operated with hundreds of atoms. For this work, we investigated the effect of detector dead time on the measurement of the second-order correlation function. Based on the result, we invented so-called dead-time-free Mandel Q measurement method. While the mandel Q is kept below -0.5, the mean photon number of the field was scalable up to 600 which is much larger than analogous experimental results in microwave regime. Furthermore, our study proves that sub-Poisson photon statistics is not deteriorated by multi-atom effects with our experimental conditions. To our best knowledge, this is the first experimental confirmation of validity of extending the single atom model to many atom regime. By including cavity damping effect, we derived a more realistic theory which can exactly describe the photon statistics in the microlaser. Our findings establish the milestone of our proposal of an effective pathway to generate quasi-Fock-state lasing at the macroscopic scale.
Sub-Poisson field with much reduced fluctuations in a cavity can boost quantum precision measurements via cavity-enhanced light-matter interactions. Strong coupling between an atom and a cavity mode has been utilized to generate highly sub-Poisson fields. However, a macroscopic number of optical intracavity photons with more than 3 dB variance reduction has not been possible. Here, we report sub-Poisson field lasing in a microlaser operating with hundreds of atoms with well-regulated atom-cavity coupling and interaction time. Its photon-number variance was 4 dB below the standard quantum limit while the intracavity mean photon number scalable up to 600. The highly sub-Poisson photon statistics were not deteriorated by simultaneous interaction of a large number of atoms. Our finding suggests an effective pathway to widely scalable near-Fock-state lasing at the macroscopic scale.
We have measured the second-order correlation function of the cavity-QED microlaser output and observed a transition from photon bunching to antibunching with increasing average number of intracavity atoms. The observed correlation times and the transition from super- to sub-Poisson photon statistics can be well described by gain-loss feedback or enhanced-reduced restoring action against fluctuations in photon number in the context of a quantum microlaser theory and a photon rate equation picture. However, the theory predicts a degree of antibunching several times larger than that observed, which may indicate the inadequacy of its treatment of atomic velocity distributions.
We observe the three-photon correlation in nonclassical light sources by using an indirect measurement scheme based on the dead-time effect of photon-counting detectors. We first develop a general theory which enables us to extract the three-photon correlation from the two-photon correlation of an arbitrary light source measured with detectors with finite dead times. We then confirm the validity of our measurement scheme in experiments done with a cavity-QED microlaser operating with a large intracavity mean photon number exhibiting both sub- and super-Poissonian photon statistics. The experimental results are in good agreement with the theoretical expectation. Our measurement scheme provides an alternative approach for NNN-photon correlation measurement employing $(N\ensuremath{-}1)$ detectors and thus a reduced measurement time for a given signal-to-noise ratio, compared to the usual scheme requiring NNN detectors.
The author presents a tutorial review of the quantum theory of the micromaser which allows for arbitrary (sub- as well as super-Poissonian) fluctuations of the pumping beam. In conventional reservoir theory the rate of change of the cavity field is a sum of the changes due to separate interaction with the individual reservoirs, i.e. the interactions are uncorrelated. In their approach, which is based on discrete mapping rather than a maser equation, corrections to reservoir theory arise due to correlations between these interactions. The magnitude of these terms is characterized by the quantity p/N ex . Here p, the parameter describing pump beam fluctuations, is the negative of the Mandel Q parameter of the pump beam so that p=1 corresponds to regular pumping, p=0 to Poissonian one and p<0 to super-Poissonian pump beam fluctuations. N ex is the number of atoms passing through the cavity during the lifetime of the intercavity field. The conventional reservoir limit (standard laser theory) is recovered if p=0 and/or N ex is large. In all other cases the interactions with the gain and loss reservoirs are correlated. The author presents analytical results to demonstrate the effect of pump regularity on steady-state problems (photon statistics, mean number of photons and photon number variance) as well as on transient phenomena (correlation function and spectrum). In particular, it is shown that the approach to equilibrium can have non-Markovian character.
This thesis describes a study of a cavity QED microlaser in which many atoms are present simultaneously and atom-cavity interaction is well-defined. The microlaser is found to display multiple thresholds analogous to first-order phase transitions of the cavity field. Hysteresis is observed as a function of atom-cavity detuning and number of atoms. Data is compared with a rate equation model and fully quantized treatment based on micromaser theory. Good agreement between theory and experiment is found when the cavity is resonant with atoms of the most probable velocity, but long lifetimes of metastable states preclude the observation of true steady-state transition points. For nonzero atom-cavity detuning the microlaser displays broadenings and shifts which are not yet well-understood. Quantum trajectory simulations are performed to investigate many-atom and finite transit time effects in the microlaser. We show that over a wide range of parameters the many-atom microlaser scales with the single-atom theory, with a perturbation in the photon statistics due to cavity decay during the atom transit time.