Medical image classification is a fundamental aspect of contemporary diagnosis, but the conventional Deep Learning (DL) model is increasingly encountering difficulties in terms of computational complexity, data availability, and interpretability. With the massive growth of medical data, the "black box" phenomenon of Convolutional Neural Networks (CNNs) hinders medical validation. This paper presents a novel Hybrid Quantum-Classical Neural Network (HQCNN) approach for multimodal diagnosis, specifically addressing Brain Tumors (MRI), Pneumonia (Chest X-Ray), and Retinal Diseases (OCT). The proposed model combines a pre-trained ResNet-18 backbone for high-level feature representation with a 4-qubit Variational Quantum Circuit (VQC) to harness the power of quantum entanglement for improved classification in high-dimensional Hilbert spaces. More-over, we close the interpretability gap by incorporating Gradient-weighted Class Activation Mapping (Grad-CAM). Experimental results show that the hybrid model performs exceptionally well, specifically with 98.76% accuracy on Retina OCT, 90.71% accuracy on Chest X-Rays and 95.27% on Brain MRI, with a substantial decrease in trainable parameters in the decision head compared to classical models.
Medical image classification is a fundamental aspect of contemporary diagnosis, but the conventional Deep Learning (DL) model is increasingly encountering difficulties in terms of computational complexity, data availability, and interpretability. With the massive growth of medical data, the "black box" phenomenon of Convolutional Neural Networks (CNNs) hinders medical validation. This paper presents a novel Hybrid Quantum-Classical Neural Network (HQCNN) approach for multimodal diagnosis, specifically addressing Brain Tumors (MRI), Pneumonia (Chest X-Ray), and Retinal Diseases (OCT). The proposed model combines a pre-trained ResNet-18 backbone for high-level feature representation with a 4-qubit Variational Quantum Circuit (VQC) to harness the power of quantum entanglement for improved classification in high-dimensional Hilbert spaces. More-over, we close the interpretability gap by incorporating Gradient-weighted Class Activation Mapping (Grad-CAM). Experimental results show that the hybrid model performs exceptionally well, specifically with 98.76% accuracy on Retina OCT, 90.71% accuracy on Chest X-Rays and 95.27% on Brain MRI, with a substantial decrease in trainable parameters in the decision head compared to classical models.
Brain tumor detection from MRI images is a critical and challenging task in medical diagnostics, where early identification greatly improves treatment outcomes. This paper presents a Hybrid Quantum– Classical Convolutional Neural Network (HQCNN) that integrates the strengths of ResNet-18 and a Variational Quantum Circuit for efficient and accurate tumor classification. The proposed model first employs ResNet-18 as a classical feature extractor, where 17 convolutional layers and pooling operations capture both low-level and high-level spatial features from MRI images. The final fully connected layer of ResNet-18 is replaced by a quantum processing layer implemented using PennyLane. In this layer, the extracted classical features are encoded onto qubits using RY rotation gates, while CNOT gates introduce entanglement between them, forming a VQC with trainable parameters. After quantum computation, Pauli-Z measurements convert the processed quantum states back into classical values, which are passed to a final fully connected layer for binary classification as Tumor or No Tumor. The hybrid integration of classical CNN feature learning with quantum entanglement– based representation enhances model generalization and interpretability. Experimental analysis demonstrates that the proposed HQCNN achieved 94.65% accuracy, outperforming traditional CNN models and confirming the potential of hybrid quantum–classical architectures for reliable and interpretable medical image diagnosis.
Abstract Pneumonia remains a leading cause of mortality globally, necessitating rapid and accurate diagnostic tools to assist radiologists. While classical Deep Learning (DL) models, particularly Convolutional Neural Networks (CNNs), have demonstrated high efficacy in medical image analysis, they are often characterized by high computational complexity and massive parameter requirements. This research proposes a novel Hybrid Quantum-Classical Neural Network (HQCNN) to detect Pneumonia from chest X-ray images with enhanced computational efficiency. By integrating a classical ResNet-18 architecture for feature extraction with a Variational Quantum Circuit (VQC) based on PennyLane, we leverage the quantum mechanical principles of superposition and entanglement for pattern recognition. The proposed model was trained and validated on a standard chest X-ray dataset and benchmarked against a classical transfer learning equivalent. Experimental results indicate that the hybrid quantum model achieved a validation accuracy of 78% with significantly fewer trainable parameters (~ 24) compared to the classical baseline (62% accuracy, ~ 1026 parameters). Furthermore, the quantum model demonstrated superior sensitivity (100% Recall), successfully identifying all positive pneumonia cases in the validation batch. This study highlights the potential of Quantum Machine Learning (QML) as a resource-efficient, high-sensitivity alternative for future medical diagnostic systems.
Medical image classification is a critical component of modern healthcare; however, accurate diagnosis remains challenging due to limited annotated datasets, class imbalance, and the high dimensionality of medical imaging data. To address these challenges, a hybrid quantum-classical neural network (HQCNN) is proposed, integrating classical deep learning with variational quantum learning for medical image classification. The proposed architecture combines a five-layer convolutional neural network (CNN) for hierarchical feature extraction with a lightweight 4-qubit variational quantum circuit (VQC) incorporating quantum state encoding, superposition and entanglement mechanisms, and a quantum attention-Fourier (QAF) module. This hybrid design aims to improve nonlinear feature representation and quantum parameter efficiency while maintaining a shallow quantum circuit suitable for noisy intermediate-scale quantum (NISQ)-era constraints. Experimental evaluation on six MedMNIST benchmark datasets demonstrated competitive performance across both binary and multi-class classification tasks. HQCNN achieved 98.88% accuracy on the binary subset of PathMNIST (classes 0 vs. 1), 97.61% accuracy on the multi-class OrganAMNIST dataset, and 86.29% accuracy on BreastMNIST. Comparative experiments and statistical analyses demonstrated consistent improvements over the controlled BHQNN baseline, while component-wise ablation studies showed that the QAF module, superposition and entanglement mechanisms, and expressive parameterized rotations contributed to classification performance in a complementary and dataset-dependent manner. Moreover, HQCNN reduced the number of trainable quantum parameters by approximately 55.6% compared with the baseline hybrid quantum neural network (BHQNN). Noise-aware simulations further showed that the model retained relatively stable predictive performance under moderate depolarizing noise, supporting further evaluation under near-term quantum computing conditions. Overall, the results demonstrate that HQCNN provides a parameter-efficient hybrid quantum-classical framework for medical image classification and offers a promising foundation for further investigation of quantum-enhanced medical image analysis.
Deep learning techniques have significantly enhanced medical image classification for disease diagnosis. However, traditional deep learning models face several challenges, such as dependence on large annotated datasets, complex architectural layers, and millions of trainable parameters, which can increase computational load and cause overfitting. Although quantum computing offers potential for parallel processing and improved feature representation, its practical use is limited by the current capabilities of Noisy Intermediate-Scale Quantum (NISQ) hardware. To overcome these issues, Hybrid Quantum–Classical Convolutional Neural Networks (HQCNNs) have been developed, using quantum properties like superposition and entanglement to improve feature extraction and classification of medical images. This review offers a thorough analysis of 50 peer-reviewed studies published from 2021 to 2026 and introduces a taxonomy of HQCNN architectures. It classifies existing approaches into three categories: Quantum-to-Classical, Classical-to-Quantum, and Hybrid Quantum Transfer Learning. The studies reviewed encompass a diverse range of medical imaging applications, including binary and multi-class disease classification using X-ray, CT, MRI, ultrasound, dermoscopic, retinal, and mammographic images. Additionally, the review compares HQCNNs with their classical CNN counterparts, exploring how factors like quantum circuit design, dataset size, class imbalance, task complexity, evaluation protocols, and hardware limitations influence classification performance. It concludes with an analysis of the key limitations of current HQCNN models, discusses challenges in deploying NISQ devices practically, and proposes future research directions to bridge the gap between experimental HQCNN frameworks and reliable clinical diagnostic systems.
Abstract Classical deep learning models often struggle to fully capture complex visual patterns and to generalize effectively when trained on limited or imbalanced medical imaging data. To address this limitation, this paper presents a novel Hybrid Quantum Deep Learning (Hybrid QDL) framework that leverages the strengths of both deep neural networks and quantum circuits for advanced medical image interpretation. The proposed model integrates a pre-trained EfficientNet-B4 as the feature extractor and a variational quantum circuit as the classification head, enabling joint learning of hierarchical and quantum-enhanced representations. The Hybrid QDL model is evaluated on three clinically relevant datasets: COVIDx (for 3-class COVID-19 diagnosis using chest X-rays), PneumoniaMNIST (for pneumonia detection), and OrganAMNIST (for multi-organ abdominal classification). The model achieves state-of-the-art results, with 98.48% accuracy and 98.33% F1-score on COVIDx, outperforming both classical and prior quantum baselines. On PneumoniaMNIST and OrganAMNIST, it reaches 98.28% and 95.27% accuracy, respectively, along with high macro F1-scores. Ablation studies confirm that increasing quantum circuit depth and entanglement enhances discriminative power, particularly in complex multi-class scenarios. These results demonstrate that the Hybrid QDL framework is a robust, scalable solution for automated medical diagnosis and holds significant promise for real-world clinical decision support and COVID-19 detection.
The problem of classifying brain tumours using magnetic resonance imaging (MRI) is a fundamental one in the field of computeraided diagnosis, since although many commonly employed convolutional neural network (CNN) architectures provide high accuracy they contain a large number of parameters, which has led to a search for more compact network designs. In this paper a hybrid quantum–classical approach is proposed that combines a lightweight CNN feature extractor with a trainable variational quantum circuit (VQC) in order to carry out four-class brain tumour classification. The MRI images are resized to 128 by 128 pixels and then processed by a small three-block CNN that reduces each image to an 8-dimensional feature vector. This vector is put into an 8-qubit quantum register by means of angle embedding and then acted on by a variational circuit composed of strongly entangling layers, by measuring each qubit in the Pauli-Z basis. The quantum features thus obtained are then fed into classical dense layers that categorise the images as glioma, meningioma, pituitary tumour or no tumour. The framework was tested on the Brain Tumor MRI dataset (7,200 images) and compared with a classical CNN baseline that was trained under the same conditions. The hybrid model reached a test accuracy of 76.88%, as compared to 72.31% for the classical baseline an improvement of 4.57 percentage points together with corresponding increases in macro-averaged precision, recall and F1-score. Notably, the hybrid model needed only 72 additional trainable parameters when compared to the classical baseline. The fact that the quantum layer was assessed using a noiseless simulator rather than on actual quantum hardware means that these results should be seen as indicating the feasibility of using compact quantum feature transformations for medical image classification rather than as showing a quantum advantage.