Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Superconducting Kinetic-Inductance Resonators for Strong Photon–Phonon Coupling in GaAs

Karthik V. Myilswamy, Joey T. Bush, Zixuan Wang, Richard P. Mirin, Kevin L. Silverman

Published Jan 1, 2026• 0 citations
Publisher

Abstract

We fabricate and characterize thin-film NbTiN superconducting microwave resonators on GaAs, designed to enhance piezoelectric interaction with phononic cavities. Their kinetic-inductance–dominated design is intended to enable future tunability of the resonance frequency.
DOI
10.1364/cleo_fs.2026.ftu1b.2

Related papers

Frequency-tunable high-Q superconducting resonators via wireless control of nonlinear kinetic inductance

Mingrui Xu, Xu Han, Wei Fu +2 more

Frequency-tunable microwave resonators are in great demand especially in hybrid systems where precise frequency alignment of resonances is required. Here, we present frequency-tunable high-Q superconducting resonators fabricated from thin niobium nitride and niobium titanium nitride films. The resonant frequency is tuned by applying a magnetic field perpendicular to the hole structures in the resonator's inductor wire, whose kinetic inductance is modified by wirelessly induced DC supercurrents. A continuous in situ frequency tuning of over 300 MHz is achieved for a 10 GHz resonator with a moderate magnetic field of 1.2 mT. The planar resonator design and the noncontact tuning scheme greatly ease the fabrication complexity and can be widely applied in many hybrid systems for coupling microwave modes with other forms of excitations such as optical photons, phonons, magnons, and spins.

Applied Physics Letters•May 13, 2019•62 citations

High kinetic inductance NbTiN superconducting transmission line resonators in the very thin film limit

Terence Bretz-Sullivan, Rupert Lewis, Ana L. Lima-Sharma +6 more

We examine the DC and radio frequency (RF) response of superconducting transmission line resonators comprised of very thin NbTiN films, <12 nm in thickness, in the high-temperature limit, where the photon energy is less than the thermal energy. The resonant frequencies of these superconducting resonators show a significant nonlinear response as a function of RF input power, which can approach a frequency shift of Δf=−0.15% in a −20 dB span in the thinnest film. The strong nonlinear response allows these very thin film resonators to serve as high kinetic inductance parametric amplifiers.

Applied Physics Letters•Aug 1, 2022•24 citations

Fabrication and Characterization of Superconducting Resonators

Giuseppe Cataldo, Emily M. Barrentine, Ari-David Brown +3 more

Superconducting microwave resonators are of interest for a wide range of applications, including for their use as microwave kinetic inductance detectors (MKIDs) for the detection of faint astrophysical signatures, as well as for quantum computing applications and materials characterization. In this paper, procedures are presented for the fabrication and characterization of thin-film superconducting microwave resonators. The fabrication methodology allows for the realization of superconducting transmission-line resonators with features on both sides of an atomically smooth single-crystal silicon dielectric. This work describes the procedure for the installation of resonator devices into a cryogenic microwave testbed and for cool-down below the superconducting transition temperature. The set-up of the cryogenic microwave testbed allows one to do careful measurements of the complex microwave transmission of these resonator devices, enabling the extraction of the properties of the superconducting lines and dielectric substrate (e.g., internal quality factors, loss and kinetic inductance fractions), which are important for device design and performance.

Journal of Visualized Experiments•May 21, 2016•3 citations

Kinetic inductance compact resonator with NbTiN micronwires

Ming Yang, Xiaoliang He, Wanpeng Gao +6 more

Nonlinear resonators of superconducting thin-film kinetic inductance have attracted considerable research interest in the fields of detectors, qubits, parametric amplifiers, and more. By tuning the deposition parameters, niobium titanium nitride (NbTiN) films (∼12 nm in thickness) present high resistivity(∼2000 μΩ cm) and large sheet kinetic inductance (∼0.7 nH/□). We designed resonators with NbTiN micronwire as the inductor and aluminum as the capacitor, which result in a high internal quality factor and a Kerr nonlinearity of a few hertz. The radio frequency response of the resonators demonstrates nonlinear behavior similar to that of the cubic Duffing oscillator, including frequency shift and hysteresis region. The kinetic inductance resonator is a promising candidate for high saturation power parametric amplifiers.

AIP Advances•Aug 1, 2024•8 citations

High-impedance superconducting resonators and on-chip filters for circuit quantum electrodynamics with semiconductor quantum dots

X. Zhang, Zhiyong Zhu, N. Phuan Ong +1 more

Spin-photon coupling presents an enticing opportunity for the long-range coupling of spin qubits. The spin-photon coupling rate, ${g}_{s}$, is proportional to the charge-photon coupling rate, ${g}_{c}$. To move deeper into the strong-coupling regime, ${g}_{c}$ can be enhanced by fabricating high-impedance cavities using high-kinetic-inductance films. Here, we report dc transport and microwave response investigations of niobium nitride ($\mathrm{Nb}\mathrm{N}$) films of different thicknesses. The kinetic inductance increases rapidly as the film thickness is reduced below 50 nm and for 15-nm $\mathrm{Nb}\mathrm{N}$ films we measure a sheet kinetic inductance ${L}_{k,S}=41.2\phantom{\rule{0.2em}{0ex}}\text{pH}/◻$. As an application of the high-kinetic-inductance films, we fabricate compact $LC$ filters that are commonly used to reduce microwave leakage in circuit quantum electrodynamics (cQED) devices. These filters feature up to 60 dB of attenuation near typical cavity resonance frequencies of ${f}_{c}=8$ GHz.

arXiv:2306.16499•Physical Review Applied•Jan 11, 2024•9 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations
Frequency-tunable microwave resonators are in great demand especially in hybrid systems where precise frequency alignment of resonances is required. Here, we present frequency-tunable high-Q superconducting resonators fabricated from thin niobium nitride and niobium titanium nitride films. The resonant frequency is tuned by applying a magnetic field perpendicular to the hole structures in the resonator's inductor wire, whose kinetic inductance is modified by wirelessly induced DC supercurrents. A continuous in situ frequency tuning of over 300 MHz is achieved for a 10 GHz resonator with a moderate magnetic field of 1.2 mT. The planar resonator design and the noncontact tuning scheme greatly ease the fabrication complexity and can be widely applied in many hybrid systems for coupling microwave modes with other forms of excitations such as optical photons, phonons, magnons, and spins.
We examine the DC and radio frequency (RF) response of superconducting transmission line resonators comprised of very thin NbTiN films, <12 nm in thickness, in the high-temperature limit, where the photon energy is less than the thermal energy. The resonant frequencies of these superconducting resonators show a significant nonlinear response as a function of RF input power, which can approach a frequency shift of Δf=−0.15% in a −20 dB span in the thinnest film. The strong nonlinear response allows these very thin film resonators to serve as high kinetic inductance parametric amplifiers.
Superconducting microwave resonators are of interest for a wide range of applications, including for their use as microwave kinetic inductance detectors (MKIDs) for the detection of faint astrophysical signatures, as well as for quantum computing applications and materials characterization. In this paper, procedures are presented for the fabrication and characterization of thin-film superconducting microwave resonators. The fabrication methodology allows for the realization of superconducting transmission-line resonators with features on both sides of an atomically smooth single-crystal silicon dielectric. This work describes the procedure for the installation of resonator devices into a cryogenic microwave testbed and for cool-down below the superconducting transition temperature. The set-up of the cryogenic microwave testbed allows one to do careful measurements of the complex microwave transmission of these resonator devices, enabling the extraction of the properties of the superconducting lines and dielectric substrate (e.g., internal quality factors, loss and kinetic inductance fractions), which are important for device design and performance.
Nonlinear resonators of superconducting thin-film kinetic inductance have attracted considerable research interest in the fields of detectors, qubits, parametric amplifiers, and more. By tuning the deposition parameters, niobium titanium nitride (NbTiN) films (∼12 nm in thickness) present high resistivity(∼2000 μΩ cm) and large sheet kinetic inductance (∼0.7 nH/□). We designed resonators with NbTiN micronwire as the inductor and aluminum as the capacitor, which result in a high internal quality factor and a Kerr nonlinearity of a few hertz. The radio frequency response of the resonators demonstrates nonlinear behavior similar to that of the cubic Duffing oscillator, including frequency shift and hysteresis region. The kinetic inductance resonator is a promising candidate for high saturation power parametric amplifiers.
Spin-photon coupling presents an enticing opportunity for the long-range coupling of spin qubits. The spin-photon coupling rate, gs{g}_{s}gs​, is proportional to the charge-photon coupling rate, gc{g}_{c}gc​. To move deeper into the strong-coupling regime, gc{g}_{c}gc​ can be enhanced by fabricating high-impedance cavities using high-kinetic-inductance films. Here, we report dc transport and microwave response investigations of niobium nitride (NbN\mathrm{Nb}\mathrm{N}NbN) films of different thicknesses. The kinetic inductance increases rapidly as the film thickness is reduced below 50 nm and for 15-nm NbN\mathrm{Nb}\mathrm{N}NbN films we measure a sheet kinetic inductance Lk,S=41.2pH/◻{L}_{k,S}=41.2\phantom{\rule{0.2em}{0ex}}\text{pH}/◻Lk,S​=41.2pH/◻. As an application of the high-kinetic-inductance films, we fabricate compact LCLCLC filters that are commonly used to reduce microwave leakage in circuit quantum electrodynamics (cQED) devices. These filters feature up to 60 dB of attenuation near typical cavity resonance frequencies of fc=8{f}_{c}=8fc​=8 GHz.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.