Abstract

The atomic magnetometers are emerging sensors for detecting ultraweak magnetic fields and have recently drawn widespread attention because of their potential applications in biomagnetic imaging. In this study, a fluorescence-based magnetic field sensing scheme tailored for miniaturized integration of spin-exchange relaxation-free (SERF) atomic magnetometers is proposed. A theoretical model is established to describe the dependence of fluorescence intensity based on atomic polarization, and an orthogonal detection configuration is constructed with a miniaturized 87Rb buffer-gas vapor cell, where fluorescence-modulated field measurements are implemented. In addition, the buffer and quenching gas compositions are optimized, yielding stronger fluorescence signals. Experimental results demonstrate that the measured fluorescence response agrees well with analytical results. The sensitivity is significantly improved, from 217.7 to$29.1~\mathrm {fT}/{\!}\sqrt {\mathrm {Hz}}$, using the proposed optimization method. These findings expand the potential of fluorescence-based detection in the applications of quantum sensing and pave the way toward compact and integrable SERF magnetometers.

DOI
10.1109/tim.2026.3711329

Related papers

Miniaturized atomic magnetometer employing pump-beam modulation

Ziqian Yue, Junjian Tang, Yueyang Zhai

Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).

Advanced Sensor Systems and Applications•Oct 11, 2024•0 citations

In-situ determination of spin polarization in a single-beam fiber-coupled spin-exchange-relaxation-free atomic magnetometer with differential detection

Yintao Ma, Zhixia Qiao, Yao Chen +8 more

The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.

Optics Express•Jan 9, 2023•5 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•74 citations

The Characterization of Atomic Vapor Cells for High-Sensitivity Magnetic Field Measurements in SERF Regime

Murat Salim Karabinaoğlu, Berfin Muhlise Caklı, Mehmet Hüseyin Sevim

Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.

IEEE Sensors Letters•Feb 24, 2025•5 citations

Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell

Yibo Qi, Bo Li, Shuying Wang +3 more

Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz$^{1/2}$) was 1.89 times that of the single-pass configuration (3.4 fT/Hz$^{1/2}$), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•18 citations

Accurate determination of alkali atom density based on zero-field magnetic resonance in a single-beam spin-exchange relaxation-free atomic magnetometer

Yintao Ma, Yao Chen, Libo Zhao +6 more

Abstract A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.

Measurement Science and Technology•May 24, 2022•10 citations
The atomic magnetometers are emerging sensors for detecting ultraweak magnetic fields and have recently drawn widespread attention because of their potential applications in biomagnetic imaging. In this study, a fluorescence-based magnetic field sensing scheme tailored for miniaturized integration of spin-exchange relaxation-free (SERF) atomic magnetometers is proposed. A theoretical model is established to describe the dependence of fluorescence intensity based on atomic polarization, and an orthogonal detection configuration is constructed with a miniaturized 87Rb buffer-gas vapor cell, where fluorescence-modulated field measurements are implemented. In addition, the buffer and quenching gas compositions are optimized, yielding stronger fluorescence signals. Experimental results demonstrate that the measured fluorescence response agrees well with analytical results. The sensitivity is significantly improved, from 217.7 to29.1 fT/ ⁣Hz29.1~\mathrm {fT}/{\!}\sqrt {\mathrm {Hz}}29.1 fT/Hz​, using the proposed optimization method. These findings expand the potential of fluorescence-based detection in the applications of quantum sensing and pave the way toward compact and integrable SERF magnetometers.
Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.
Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz1/2^{1/2}1/2) was 1.89 times that of the single-pass configuration (3.4 fT/Hz1/2^{1/2}1/2), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
Abstract A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.