Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics Letters A

Optimal squeezing for phase estimation in coherent state seeded SU(1,1) interferometer

Vikas Kumar Prajapati, Priyanka Sharma, Ravi Kamal Pandey, Gaurav K. Shukla

Published Jul 9, 2026• 0 citations
Publisher
DOI
10.1016/j.physleta.2026.131995

Related papers

Realizing the optimal measurement scheme for an SU(1,1) interferometer in ab initio phase estimation

Mingchen Liu, Haixing Miao, Lijian Zhang

Physical Review A•Jun 3, 2025•1 citation

Improving phase sensitivity of SU(1,1) interferometer using even and odd coherent states and squeezed vacuum state

Abdelmajid El Maaroufi, Abbas Manan, Bouchra Maroufi +2 more

Physics Letters A•Dec 5, 2025•2 citations

Enhancement in phase sensitivity of SU(1,1) interferometer with Kerr state seeding

Priyanka Sharma, Aviral Kumar Pandey, Gaurav Shukla +1 more

arXiv:2404.02674•Optics Communications•Aug 30, 2024•6 citations

Parity-based estimation in an SU(1,1) interferometer with photon-subtracted squeezed vacuum states

Li-Li Hou, Jiandong Zhang, Shuai Wang

Optics Communications•Mar 13, 2023•3 citations

Nonlinear phase estimation based on nonlinear interferometers with coherent and squeezed vacuum light

Jiandong Zhang, Shuai Wang

Physics Letters A•Feb 27, 2024•3 citations

Optimized phase sensing in a truncated SU(1,1) interferometer

Prasoon Gupta, Bonnie L. Schmittberger, Brian E. Anderson +2 more

Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.

arXiv:1802.04314•Optics Express•Jan 4, 2018•58 citations
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.