Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Onto-Physical Entanglement and Quantum Proper-Time Readout: CPT-Coherence Theory, Optical Ion Clocks, and the Experimental Interface Between Identity and Evolution

Joseph Julian

Published Jul 1, 2026• 0 citations
Publisher

Abstract

Optical ion clocks now approach a regime in which relativistic time dilation is no longer exhausted by a classical proper-time parameter read by a quantum sensor. Recent work by Sorci, Foo, Leibfried, Sanner, and Pikovski shows that harmonically trapped optical clock atoms can exhibit vacuum-induced, squeezing-induced, and intrinsically quantum corrections to the second-order Doppler shift, with time-dilation-induced entanglement between motional and internal clock degrees of freedom becoming observable in strongly squeezed trapped-ion motion. This paper develops the significance of that result within CPT-Coherence Theory. The central principle of CPT-Coherence is Onto-Physical Entanglement: what a system is cannot be separated from how it is allowed to remain coherent under admissible transformation. In the clock setting, this principle appears in branch-visible form. The internal clock transition is not merely an isolated label transported through spacetime; its phase identity is dynamically bound to the motional state through the relativistic proper-time operator. Proper-time interferometry therefore supplies a laboratory instance of a more general structural rule: physical identity is stabilized only through the admissible evolution channels by which it can be read out. The paper distinguishes the relativistic proper time of the ion-clock experiment from the coherence-depth coordinate of CPT-Coherence. The former is a branch-visible observable associated with worldline evolution; the latter is a structural coordinate organizing parent-boundary admissibility, trace access, Schur response, and stable observable descent. Their relation is not identity but projection: quantum proper-time readout provides an experimentally precise interface through which branch observers can test how internal identity, motion, coherence, and record formation remain coupled. We formulate a CPT-Coherence clock-readout sector in which a quantum clock is represented by a triple consisting of an internal identity generator, an external motion algebra, and a proper-time readout operator. The Sorci-Foo-Leibfried-Sanner-Pikovski protocol is then interpreted as a high-precision realization of an OPE readout channel: classical time dilation corresponds to scalar proper-time averaging; vacuum and squeezing shifts correspond to state-dependent branch corrections; and visibility loss corresponds to trace-visible entanglement between identity and admissible motion. This establishes optical ion clocks as a natural experimental grammar for CPT-Coherence, while CPT-Coherence supplies a unifying interpretation of why such experiments probe not simply clock rates, but the inseparability of physical being and physical evolution. Scope note: the quantitative predictions below coincide with those of standard relativistic quantum clock theory; CPT-Coherence contributes an interpretation and vocabulary, together with an explicit falsification target for that interpretation.

DOI
10.5281/zenodo.21152289

Related papers

Quantum Signatures of Proper Time in Optical Ion Clocks

Gabriel Sorci, Joshua Foo, Dietrich G. Leibfried +2 more

Optical clocks based on atoms and ions probe relativistic effects with unprecedented sensitivity. They resolve time dilation due to atom motion or different positions in the gravitational potential through frequency shifts. However, all measurements of time dilation so far can be explained effectively as the result of dynamics with respect to a classical proper time parameter. Here we show that atomic clocks can probe effects where a classical description of the proper time dynamics is insufficient as superpositions of proper time emerge. We apply a Hamiltonian formalism to derive time dilation effects in harmonically trapped clock atoms and show how second-order Doppler shifts due to the vacuum energy, squeezing, and quantum corrections to the dynamics arise. We also demonstrate that time-dilation-induced entanglement between motion and clock evolution can become observable in state-of-the-art clocks when the motion of the atoms is strongly squeezed, realizing proper time interferometry. Our results show that experiments with trapped ion clocks are within reach of probing relativistic evolution of clocks for which a quantum description of proper time becomes necessary.

arXiv:2509.09573•Physical Review Letters•Feb 27, 2026•6 citations

Time as Record: Proper Time, Psychological Time, and Onto-Physical Entanglement: A CPT-Coherence Framework for Distinct Temporal Readout Regimes

Joseph Julian

Time is not a single operational object. Laboratory time, relativistic proper time, biological timing, psychological duration, and coherence-depth structure play different roles and are accessed by different readout systems. This paper develops a theoretical framework for distinguishing these temporal regimes while identifying a common structural feature: each becomes physically or experientially meaningful only through a system capable of generating stable records of change. The starting point is quantum proper-time readout in optical ion clocks. In relativistic quantum clock experiments, proper time is not merely an external scalar parameter; it is inferred from an internal phase record whose visibility can be degraded when clock identity becomes entangled with motional history. Such systems provide a controlled physical example of time-as-record: the clock records elapsed proper time only insofar as its internal identity remains coherent under admissible evolution. We use this clock setting to introduce a broader distinction among four temporal objects: tlab, tprop, tpsych, TC. Here tlab is laboratory coordinate time, tprop is relativistic proper time recorded by physical clocks, tpsych is psychological time generated by cognitive and embodied record processes, and TC is the CPT-Coherence structural coordinate organizing admissibility, trace access, and stable observable descent. These quantities are not identical. The central thesis is not that psychological time is quantum proper time, nor that optical clocks measure consciousness or coherence depth. The thesis is narrower: proper time and psychological time are categorically distinct but structurally comparable as readout regimes. Within CPT-Coherence Theory, this comparison is organized by Onto-Physical Entanglement: what a system is cannot be separated from how it remains coherent under admissible transformation. In the clock case, identity persistence is measured by phase coherence and Ramsey visibility. In the cognitive case, psychological duration is modeled as a higher-level record produced by attention, interoception, memory, arousal, prediction, and event segmentation. The proposed object is not a single inner clock, but a cognitive readout functional: Reccog : embodied cognitive state history → (duration, ordering, temporal confidence, felt passage). This permits a disciplined analogy: proper time is physical clock-readout; psychological time is cognitive record-readout; coherence depth is the structural admissibility coordinate of the theory. The paper formulates a temporal-readout taxonomy, introduces record-stability witnesses for both physical and psychological timing, and specifies failure conditions that prevent the framework from collapsing into metaphor. The result is a falsifiable perspective: if psychological duration is a record-stability phenomenon, then distortions of subjective time should correlate not only with estimated duration, but also with measurable changes in attention, bodily-state integration, memory ordering, confidence, and event-boundary structure. Thus, the physics of proper-time readout does not explain psychological time directly; it supplies a rigorous model of how time becomes a record for an embedded system.

•Jul 1, 2026•0 citations

Quantum Proper-Time Clocks as Temporal Interfaces: A Diagnostic Note on Clockability, Proper Time, and Temporal Exportability

Danilo Tavella

This technical note treats recent work on quantum signatures of proper time in optical ion clocks as an external stress reference for the Clockability cluster. The note does not propose a new theory of time, nor does it interpret quantum optical clocks as confirming Clockability. Instead, it distinguishes proper-time accumulation, physical clock readout, trace comparability, and temporal exportability as separate descriptive levels. Optical ion clocks are analyzed as temporal interfaces: finite physical architectures through which proper-time signatures become accessible under specific conditions of state preparation, motional structure, coherence, and readout. The aim is diagnostic only: to clarify how high-precision quantum-clock regimes make visible the distinction between local proper-time dynamics and the operational availability of temporal order.

•May 19, 2026•0 citations

Necessity Recursion and a Pre-Registered φ-Attractor Prediction for Proper-Time Superposition in Optical Ion Clocks

Abby Davis

On 20 April 2026, Sorci, Foo, Leibfried, Sanner, and Pikovski (Phys. Rev. Lett.) proposed that next-generation optical ion clocks with squeezed-state preparation can probe whether proper time exists in quantum superposition — a single clock ticking faster and slower at once. Their work establishes the protocol; the laboratory measurement is forthcoming. That prospective window permits a genuine pre-registered prediction. Fibonacci Causal Loop Theory (FCLT) holds that any stable system governed by depth-2 necessity recursion, S(n)=S(n−1)+S(n−2), is driven to the golden ratio φ=(1+√5)/2 — the unique algebraically forced attractor of its characteristic equation x²−x−1=0. We advance the hypothesis that proper-time superposition is such a system, the two temporal branches playing the role of the two prior states, so that the ratio of fast- to slow-ticking amplitudes approaches φ upon decoherence. From this we obtain one parameter-free, falsifiable prediction — t₊/t₋ → φ ≈ 1.61803, with δ = |R−φ|/φ and falsification at δ > 0.10 — logged under Protocol V3.1 prior to experimental resolution. We claim no confirmation: the prediction is offered as not-yet-tested, to be adjudicated by the Stevens/NIST program. A second, independent signature (φ-structured fringe spacing in the squeezed regime) provides an internal consistency check.

•May 10, 2026•0 citations

Operational Recoverability Bounds for Proper-Time Interferometry with Open Quantum Clocks

K Z Zhao

Abstract Clock interferometry probes general-relativistic proper-time differences through the entanglement between a particle's center-of-mass path and its internal degrees of freedom. Existing analyses treat the internal clock as either a closed system or study how environmental noise modifies the interferometric visibility. Here we address a distinct question: what fraction of the proper-time-induced visibility loss remains recoverable when the experimentalist is restricted to local unitary control of the internal clock? We model the clock as a two-level system undergoing amplitude damping with branch-dependent proper times in a Mach-Zehnder interferometer and derive the visibility both without and with a spin-echo refocusing pulse. In the closed-system limit ($\gamma\to0$), the echo restores full visibility; for $\gamma>0$, the no-jump survival probability imposes a strict upper bound on echo-recovered visibility that no internal-only unitary can exceed. We establish the conditions under which a proper-time-parametrized Gorini-Kossakowski-Sudarshan-Lindblad equation is valid by appealing to the local comoving frame and the equivalence principle, distinguishing comoving-bath and laboratory-bath parametrizations. Numerical simulations with QuTiP confirm all analytic results. We provide experimental parameter estimates for cold-atom and cavity-QED platforms, showing that the irrecoverable visibility deficit is within reach of near-future clock-interferometry experiments. The echo-recovery deficit constitutes an operational witness that separates irreversible environmental decoherence from the formally reversible path-clock entanglement of the Pikovski mechanism.

International Journal of Theoretical Physics•Aug 28, 2026•0 citations

Scalar Clocks, Awareness Tensors, and Gravity as Time Decoherence: Three Testable Predictions for Record-Sensitive Geometry

EUGENE CATRAMBONE

This manuscript develops three concrete, falsifiable predictions based on a framework in which time and space are operationally equivalent, and classical reality is understood as the record. In this scalar-clock / awareness-tensor / Trinity picture, an observation is any physical process that stabilizes correlations into durable, revisitable records, and gravity is interpreted as time decoherence: clock-locking and time selection into dominant mass time-zones. The paper introduces three phenomenological parameters that are exactly zero in standard GR+QM: (i) ϵ\epsilonϵ, the sensitivity of co-located clock rates to engineered decoherence and monitoring strength; (ii) η\etaη, the sensitivity of effective gravitational acceleration to record-export structure at fixed mass distribution; and (iii) a scalar time-mismatch scale ΔT∗\Delta T_\astΔT∗, beyond which interference visibility near a mass exhibits a protocol-dependent threshold. These parameters are tied to operational proxies: clock-locking depth, time mismatch, and coupling gradients. From this framework, three testable predictions follow: Entanglement-dependent time dilation: Two identical, co-located precision clocks in the same gravitational potential but in different record-coupling regimes (high vs. low monitoring and decoherence) should exhibit a small, persistent differential drift that tracks clock-locking depth, not altitude or velocity. Gravity modulation by engineered decoherence: In a torsion balance, atom interferometer, or precision gravimeter, the measured acceleration toward a test mass should differ slightly between “decoherence OFF” and “decoherence ON” conditions, even when the mass distribution and EM fields are unchanged. The key signature is a protocol-locked Δg\Delta gΔg that appears only when scattered quanta are recorded, not when the same fields are present but their outputs are dumped locally. Entanglement horizon near mass: In a matter-wave interferometer, as one arm approaches a mass (or as the mass is increased), interference visibility should drop at a characteristic threshold set by scalar-clock mismatch and record structure. This defines an “entanglement horizon” in time-mismatch space, distinct from smooth environmental decoherence. For each effect, the paper defines explicit null hypotheses, identifies leading systematics, and sketches minimal experimental protocols compatible with current or near-term optical clocks, gravimetry, and matter-wave interferometry platforms. A brief CPT-compatibility analysis clarifies that microscopic dynamics remain CPT-symmetric in the usual QFT sense; any asymmetries arise only at the coarse-grained level of record formation and clock-locking. The proposals can therefore be read either as parameterized extensions of GR+QM using measurement architecture as an additional knob, or as an operational test of a broader “gravity as time decoherence” interpretation in which geometry becomes explicitly record-sensitive. This Version 2 is a revised and expanded update of the original upload, adding a phenomenology-first summary, clarifying the roles of the parameters (ϵ,η,ΔT∗)(\epsilon,\eta,\Delta T_\ast)(ϵ,η,ΔT∗), and situating the framework more explicitly relative to existing work on gravity-related decoherence, hybrid classical–quantum gravity, and clock/interferometry proposals (Diósi–Penrose, Bassi, Anastopoulos–Hu, Oppenheim, Zych–Costa–Pikovski–Brukner, Bose et al.). The updated version explicitly restricts the criterion to record-sensitive effects, rather than any effect. It explicitly spells out what “record formation on/off” means in practice: detectors and logging are turned on/off while the physical fields are held fixed, i.e., outputs are either stored or not stored. This version tightens falsifiability and lab usability. It (i) commits to explicit benchmark model families for the three predictions, each reducing to standard physics when ϵ=η=κ=0\epsilon=\eta=\kappa=0ϵ=η=κ=0; (ii) defines an unambiguous export-axis variable via the exported mutual-information rate I˙XR\dot I_{XR}I˙XR and export depth E\mathcal{E}E, enabling cross-platform comparisons; (iii) adds a fully worked, platform-specific optical lattice clock pilot (C1 vs C2 export-only toggle) including invariance audits, confound/error budgeting, preregistered power/discriminability analysis, and an end-to-end analysis pipeline; and (iv) upgrades mandatory reporting/preregistration templates so null results produce publishable bounds on (ϵ,η,κ)(\epsilon,\eta,\kappa)(ϵ,η,κ).

•Dec 30, 2025•0 citations
Optical ion clocks now approach a regime in which relativistic time dilation is no longer exhausted by a classical proper-time parameter read by a quantum sensor. Recent work by Sorci, Foo, Leibfried, Sanner, and Pikovski shows that harmonically trapped optical clock atoms can exhibit vacuum-induced, squeezing-induced, and intrinsically quantum corrections to the second-order Doppler shift, with time-dilation-induced entanglement between motional and internal clock degrees of freedom becoming observable in strongly squeezed trapped-ion motion. This paper develops the significance of that result within CPT-Coherence Theory. The central principle of CPT-Coherence is Onto-Physical Entanglement: what a system is cannot be separated from how it is allowed to remain coherent under admissible transformation. In the clock setting, this principle appears in branch-visible form. The internal clock transition is not merely an isolated label transported through spacetime; its phase identity is dynamically bound to the motional state through the relativistic proper-time operator. Proper-time interferometry therefore supplies a laboratory instance of a more general structural rule: physical identity is stabilized only through the admissible evolution channels by which it can be read out. The paper distinguishes the relativistic proper time of the ion-clock experiment from the coherence-depth coordinate of CPT-Coherence. The former is a branch-visible observable associated with worldline evolution; the latter is a structural coordinate organizing parent-boundary admissibility, trace access, Schur response, and stable observable descent. Their relation is not identity but projection: quantum proper-time readout provides an experimentally precise interface through which branch observers can test how internal identity, motion, coherence, and record formation remain coupled. We formulate a CPT-Coherence clock-readout sector in which a quantum clock is represented by a triple consisting of an internal identity generator, an external motion algebra, and a proper-time readout operator. The Sorci-Foo-Leibfried-Sanner-Pikovski protocol is then interpreted as a high-precision realization of an OPE readout channel: classical time dilation corresponds to scalar proper-time averaging; vacuum and squeezing shifts correspond to state-dependent branch corrections; and visibility loss corresponds to trace-visible entanglement between identity and admissible motion. This establishes optical ion clocks as a natural experimental grammar for CPT-Coherence, while CPT-Coherence supplies a unifying interpretation of why such experiments probe not simply clock rates, but the inseparability of physical being and physical evolution. Scope note: the quantitative predictions below coincide with those of standard relativistic quantum clock theory; CPT-Coherence contributes an interpretation and vocabulary, together with an explicit falsification target for that interpretation.
Optical clocks based on atoms and ions probe relativistic effects with unprecedented sensitivity. They resolve time dilation due to atom motion or different positions in the gravitational potential through frequency shifts. However, all measurements of time dilation so far can be explained effectively as the result of dynamics with respect to a classical proper time parameter. Here we show that atomic clocks can probe effects where a classical description of the proper time dynamics is insufficient as superpositions of proper time emerge. We apply a Hamiltonian formalism to derive time dilation effects in harmonically trapped clock atoms and show how second-order Doppler shifts due to the vacuum energy, squeezing, and quantum corrections to the dynamics arise. We also demonstrate that time-dilation-induced entanglement between motion and clock evolution can become observable in state-of-the-art clocks when the motion of the atoms is strongly squeezed, realizing proper time interferometry. Our results show that experiments with trapped ion clocks are within reach of probing relativistic evolution of clocks for which a quantum description of proper time becomes necessary.
Time is not a single operational object. Laboratory time, relativistic proper time, biological timing, psychological duration, and coherence-depth structure play different roles and are accessed by different readout systems. This paper develops a theoretical framework for distinguishing these temporal regimes while identifying a common structural feature: each becomes physically or experientially meaningful only through a system capable of generating stable records of change. The starting point is quantum proper-time readout in optical ion clocks. In relativistic quantum clock experiments, proper time is not merely an external scalar parameter; it is inferred from an internal phase record whose visibility can be degraded when clock identity becomes entangled with motional history. Such systems provide a controlled physical example of time-as-record: the clock records elapsed proper time only insofar as its internal identity remains coherent under admissible evolution. We use this clock setting to introduce a broader distinction among four temporal objects: tlab, tprop, tpsych, TC. Here tlab is laboratory coordinate time, tprop is relativistic proper time recorded by physical clocks, tpsych is psychological time generated by cognitive and embodied record processes, and TC is the CPT-Coherence structural coordinate organizing admissibility, trace access, and stable observable descent. These quantities are not identical. The central thesis is not that psychological time is quantum proper time, nor that optical clocks measure consciousness or coherence depth. The thesis is narrower: proper time and psychological time are categorically distinct but structurally comparable as readout regimes. Within CPT-Coherence Theory, this comparison is organized by Onto-Physical Entanglement: what a system is cannot be separated from how it remains coherent under admissible transformation. In the clock case, identity persistence is measured by phase coherence and Ramsey visibility. In the cognitive case, psychological duration is modeled as a higher-level record produced by attention, interoception, memory, arousal, prediction, and event segmentation. The proposed object is not a single inner clock, but a cognitive readout functional: Reccog : embodied cognitive state history → (duration, ordering, temporal confidence, felt passage). This permits a disciplined analogy: proper time is physical clock-readout; psychological time is cognitive record-readout; coherence depth is the structural admissibility coordinate of the theory. The paper formulates a temporal-readout taxonomy, introduces record-stability witnesses for both physical and psychological timing, and specifies failure conditions that prevent the framework from collapsing into metaphor. The result is a falsifiable perspective: if psychological duration is a record-stability phenomenon, then distortions of subjective time should correlate not only with estimated duration, but also with measurable changes in attention, bodily-state integration, memory ordering, confidence, and event-boundary structure. Thus, the physics of proper-time readout does not explain psychological time directly; it supplies a rigorous model of how time becomes a record for an embedded system.
This technical note treats recent work on quantum signatures of proper time in optical ion clocks as an external stress reference for the Clockability cluster. The note does not propose a new theory of time, nor does it interpret quantum optical clocks as confirming Clockability. Instead, it distinguishes proper-time accumulation, physical clock readout, trace comparability, and temporal exportability as separate descriptive levels. Optical ion clocks are analyzed as temporal interfaces: finite physical architectures through which proper-time signatures become accessible under specific conditions of state preparation, motional structure, coherence, and readout. The aim is diagnostic only: to clarify how high-precision quantum-clock regimes make visible the distinction between local proper-time dynamics and the operational availability of temporal order.
On 20 April 2026, Sorci, Foo, Leibfried, Sanner, and Pikovski (Phys. Rev. Lett.) proposed that next-generation optical ion clocks with squeezed-state preparation can probe whether proper time exists in quantum superposition — a single clock ticking faster and slower at once. Their work establishes the protocol; the laboratory measurement is forthcoming. That prospective window permits a genuine pre-registered prediction. Fibonacci Causal Loop Theory (FCLT) holds that any stable system governed by depth-2 necessity recursion, S(n)=S(n−1)+S(n−2), is driven to the golden ratio φ=(1+√5)/2 — the unique algebraically forced attractor of its characteristic equation x²−x−1=0. We advance the hypothesis that proper-time superposition is such a system, the two temporal branches playing the role of the two prior states, so that the ratio of fast- to slow-ticking amplitudes approaches φ upon decoherence. From this we obtain one parameter-free, falsifiable prediction — t₊/t₋ → φ ≈ 1.61803, with δ = |R−φ|/φ and falsification at δ > 0.10 — logged under Protocol V3.1 prior to experimental resolution. We claim no confirmation: the prediction is offered as not-yet-tested, to be adjudicated by the Stevens/NIST program. A second, independent signature (φ-structured fringe spacing in the squeezed regime) provides an internal consistency check.
Abstract Clock interferometry probes general-relativistic proper-time differences through the entanglement between a particle's center-of-mass path and its internal degrees of freedom. Existing analyses treat the internal clock as either a closed system or study how environmental noise modifies the interferometric visibility. Here we address a distinct question: what fraction of the proper-time-induced visibility loss remains recoverable when the experimentalist is restricted to local unitary control of the internal clock? We model the clock as a two-level system undergoing amplitude damping with branch-dependent proper times in a Mach-Zehnder interferometer and derive the visibility both without and with a spin-echo refocusing pulse. In the closed-system limit (γ→0\gamma\to0γ→0), the echo restores full visibility; for γ>0\gamma>0γ>0, the no-jump survival probability imposes a strict upper bound on echo-recovered visibility that no internal-only unitary can exceed. We establish the conditions under which a proper-time-parametrized Gorini-Kossakowski-Sudarshan-Lindblad equation is valid by appealing to the local comoving frame and the equivalence principle, distinguishing comoving-bath and laboratory-bath parametrizations. Numerical simulations with QuTiP confirm all analytic results. We provide experimental parameter estimates for cold-atom and cavity-QED platforms, showing that the irrecoverable visibility deficit is within reach of near-future clock-interferometry experiments. The echo-recovery deficit constitutes an operational witness that separates irreversible environmental decoherence from the formally reversible path-clock entanglement of the Pikovski mechanism.
This manuscript develops three concrete, falsifiable predictions based on a framework in which time and space are operationally equivalent, and classical reality is understood as the record. In this scalar-clock / awareness-tensor / Trinity picture, an observation is any physical process that stabilizes correlations into durable, revisitable records, and gravity is interpreted as time decoherence: clock-locking and time selection into dominant mass time-zones. The paper introduces three phenomenological parameters that are exactly zero in standard GR+QM: (i) ϵ\epsilonϵ, the sensitivity of co-located clock rates to engineered decoherence and monitoring strength; (ii) η\etaη, the sensitivity of effective gravitational acceleration to record-export structure at fixed mass distribution; and (iii) a scalar time-mismatch scale ΔT∗\Delta T_\astΔT∗, beyond which interference visibility near a mass exhibits a protocol-dependent threshold. These parameters are tied to operational proxies: clock-locking depth, time mismatch, and coupling gradients. From this framework, three testable predictions follow: Entanglement-dependent time dilation: Two identical, co-located precision clocks in the same gravitational potential but in different record-coupling regimes (high vs. low monitoring and decoherence) should exhibit a small, persistent differential drift that tracks clock-locking depth, not altitude or velocity. Gravity modulation by engineered decoherence: In a torsion balance, atom interferometer, or precision gravimeter, the measured acceleration toward a test mass should differ slightly between “decoherence OFF” and “decoherence ON” conditions, even when the mass distribution and EM fields are unchanged. The key signature is a protocol-locked Δg\Delta gΔg that appears only when scattered quanta are recorded, not when the same fields are present but their outputs are dumped locally. Entanglement horizon near mass: In a matter-wave interferometer, as one arm approaches a mass (or as the mass is increased), interference visibility should drop at a characteristic threshold set by scalar-clock mismatch and record structure. This defines an “entanglement horizon” in time-mismatch space, distinct from smooth environmental decoherence. For each effect, the paper defines explicit null hypotheses, identifies leading systematics, and sketches minimal experimental protocols compatible with current or near-term optical clocks, gravimetry, and matter-wave interferometry platforms. A brief CPT-compatibility analysis clarifies that microscopic dynamics remain CPT-symmetric in the usual QFT sense; any asymmetries arise only at the coarse-grained level of record formation and clock-locking. The proposals can therefore be read either as parameterized extensions of GR+QM using measurement architecture as an additional knob, or as an operational test of a broader “gravity as time decoherence” interpretation in which geometry becomes explicitly record-sensitive. This Version 2 is a revised and expanded update of the original upload, adding a phenomenology-first summary, clarifying the roles of the parameters (ϵ,η,ΔT∗)(\epsilon,\eta,\Delta T_\ast)(ϵ,η,ΔT∗), and situating the framework more explicitly relative to existing work on gravity-related decoherence, hybrid classical–quantum gravity, and clock/interferometry proposals (Diósi–Penrose, Bassi, Anastopoulos–Hu, Oppenheim, Zych–Costa–Pikovski–Brukner, Bose et al.). The updated version explicitly restricts the criterion to record-sensitive effects, rather than any effect. It explicitly spells out what “record formation on/off” means in practice: detectors and logging are turned on/off while the physical fields are held fixed, i.e., outputs are either stored or not stored. This version tightens falsifiability and lab usability. It (i) commits to explicit benchmark model families for the three predictions, each reducing to standard physics when ϵ=η=κ=0\epsilon=\eta=\kappa=0ϵ=η=κ=0; (ii) defines an unambiguous export-axis variable via the exported mutual-information rate I˙XR\dot I_{XR}I˙XR and export depth E\mathcal{E}E, enabling cross-platform comparisons; (iii) adds a fully worked, platform-specific optical lattice clock pilot (C1 vs C2 export-only toggle) including invariance audits, confound/error budgeting, preregistered power/discriminability analysis, and an end-to-end analysis pipeline; and (iv) upgrades mandatory reporting/preregistration templates so null results produce publishable bounds on (ϵ,η,κ)(\epsilon,\eta,\kappa)(ϵ,η,κ).