Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Informatics

Hybrid Quantum-Classical Neural Networks for Healthcare Prediction Powered by Automated Scientific Discovery

Karthik Meduri, Ruthvik Yedla, Santosh Reddy Addula, Guna Sekhar Sajja, Shaila Rana, Elyson De La Cruz, Mohan Harish Maturi, Hari Gonaygunta

Published Jun 22, 2026• 0 citations
Publisher

Abstract

This study presents a reproducible evaluation framework for hybrid quantum-classical neural networks (HQCNNs) in healthcare classification, rather than a new architecture. We assess a four-qubit HQCNN combining a compact classical encoder, a two-layer parameterized quantum circuit (PQC), and a classical readout (441 trainable parameters) against carefully tuned classical baselines on the Wisconsin Diagnostic Breast Cancer (WDBC) dataset under identical five-fold cross-validation. The work is framed as a single-dataset proof-of-concept: the contribution is a documented, shared-fold evaluation protocol with a parameter-matched classical control and a quantified epistemic-informativeness analysis, not a demonstration of general quantum advantage. The HQCNN reached 96.49±1.96% accuracy and 99.44±0.60% ROC-AUC. A parameter-matched classical multilayer perceptron (441 parameters) reached 95.08±1.81% accuracy; the HQCNN’s +1.41 percentage-point edge at equal capacity was not statistically significant (paired t, p=0.056). Across five shared folds, no HQCNN-versus-classical accuracy difference survived Holm–Bonferroni correction (all adjusted p≥0.625), so we report the HQCNN as competitive with, not superior to, strong tuned classical baselines. A multi-split depth ablation showed that circuit depth L∈{1,2,3} had no statistically detectable effect on accuracy (L=2 vs. L=3: Wilcoxon p=1.00); we therefore adopt two variational layers as a practical default rather than an optimum. Under a low-noise simulator (depolarising and amplitude-damping channels, p=0.01), accuracy was 96.49%, indicating robustness only at modest uniform error rates; realistic hardware noise is higher. We additionally apply Bayesian surprise as an epistemic-informativeness heuristic—not a formal generative model—to rank which findings are most worth building on. The framework offers a reproducible, documented evaluation procedure that can support cumulative comparison of hybrid quantum-classical models in healthcare.

DOI
10.3390/informatics13060098

Related papers

HQCNN: a hybrid quantum-classical neural network with Fourier-inspired quantum attention for medical image classification

Shahjalal Khan, Jahid Karim Fahim, Pintu Chandra Paul +5 more

Medical image classification is a critical component of modern healthcare; however, accurate diagnosis remains challenging due to limited annotated datasets, class imbalance, and the high dimensionality of medical imaging data. To address these challenges, a hybrid quantum-classical neural network (HQCNN) is proposed, integrating classical deep learning with variational quantum learning for medical image classification. The proposed architecture combines a five-layer convolutional neural network (CNN) for hierarchical feature extraction with a lightweight 4-qubit variational quantum circuit (VQC) incorporating quantum state encoding, superposition and entanglement mechanisms, and a quantum attention-Fourier (QAF) module. This hybrid design aims to improve nonlinear feature representation and quantum parameter efficiency while maintaining a shallow quantum circuit suitable for noisy intermediate-scale quantum (NISQ)-era constraints. Experimental evaluation on six MedMNIST benchmark datasets demonstrated competitive performance across both binary and multi-class classification tasks. HQCNN achieved 98.88% accuracy on the binary subset of PathMNIST (classes 0 vs. 1), 97.61% accuracy on the multi-class OrganAMNIST dataset, and 86.29% accuracy on BreastMNIST. Comparative experiments and statistical analyses demonstrated consistent improvements over the controlled BHQNN baseline, while component-wise ablation studies showed that the QAF module, superposition and entanglement mechanisms, and expressive parameterized rotations contributed to classification performance in a complementary and dataset-dependent manner. Moreover, HQCNN reduced the number of trainable quantum parameters by approximately 55.6% compared with the baseline hybrid quantum neural network (BHQNN). Noise-aware simulations further showed that the model retained relatively stable predictive performance under moderate depolarizing noise, supporting further evaluation under near-term quantum computing conditions. Overall, the results demonstrate that HQCNN provides a parameter-efficient hybrid quantum-classical framework for medical image classification and offers a promising foundation for further investigation of quantum-enhanced medical image analysis.

International Journal of Advanced Technology and Engineering Exploration•Aug 31, 2026•0 citations

HQCNN: A Hybrid Quantum-Classical Neural Network for Medical Image Classification

Shahjalal, Jahid Karim Fahim, Pintu Chandra Paul +3 more

Classification of medical images plays a vital role in medical image analysis; however, it remains challenging due to the limited availability of labeled data, class imbalances, and the complexity of medical patterns. To overcome these challenges, we propose a novel Hybrid Quantum-Classical Neural Network (HQCNN) for both binary and multi-class classification. The architecture of HQCNN integrates a five-layer classical convolutional backbone with a 4-qubit variational quantum circuit that incorporates quantum state encoding, superpositional entanglement, and a Fourier-inspired quantum attention mechanism. We evaluate the model on six MedMNIST v2 benchmark datasets. The HQCNN consistently outperforms classical and quantum baselines, achieving up to 99.91% accuracy and 100.00% AUC on PathMNIST (binary) and 99.95% accuracy on OrganAMNIST (multi-class) with strong robustness on noisy datasets like BreastMNIST (87.18% accuracy). The model demonstrates superior generalization capability and computational efficiency, accomplished with significantly fewer trainable parameters, making it suitable for data-scarce scenarios. Our findings provide strong empirical evidence that hybrid quantum-classical models can advance medical imaging tasks.

arXiv:2509.14277•Sep 16, 2025•5 citations

Brain Tumor Diagnosis Using Quantum Convolutional Neural Networks

Muhammad Al-Zafar Khan, Abdullah Al Omar Galib, Nouhaila Innan +1 more

Accurate classification of brain tumors from MRI scans is critical for effective treatment planning. This study presents a Hybrid Quantum Convolutional Neural Network (HQCNN) that integrates quantum feature-encoding circuits with depth-wise separable convolutional layers to analyze images from a publicly available brain tumor dataset. Evaluated on this dataset, the HQCNN achieved 99.16% training accuracy and 91.47% validation accuracy, demonstrating robust performance across varied imaging conditions. The quantum layers capture complex, non-linear relationships, while separable convolutions ensure computational efficiency. By reducing both parameter count and circuit depth, the architecture is compatible with near-term quantum hardware and resource-constrained clinical environments. These results establish a foundation for integrating quantum-enhanced models into medical-imaging workflows with minimal changes to existing software platforms. Future work will extend evaluation to multi-center cohorts, assess real-time inference on quantum simulators and hardware, and explore integration with surgical-planning systems.

arXiv:2401.15804•Jan 28, 2024•30 citations

Compress, Encode, Diagnose: PCA-Enhanced QNNs for Breast Cancer Classification

Aman Kumar Prajapati, Lupam K Saha, Mohammed Nabeel Ahsan +1 more

Quantum neural networks (QNNs) offer a promising avenue for machine learning by leveraging quantum computation, but practical QNN models are constrained by the low dimensionality of the input data they can handle. This paper proposes a hybrid quantum-classical neural network architecture that incorporates principal component analysis (PCA) for dimensionality reduction and variational quantum circuits (VQC) for quantum feature encoding. Focusing on the Wisconsin Diagnostic Breast Cancer dataset (569 instances, 30 features) as a representative biomedical classification task, in this work, we design hybrid quantum-classical neural network (QNN) models using 5-qubit and 10-qubit quantum circuits. For comparison, we use classical baseline identical to the downstream head but without the VQC+measurement. The preprocessed inputs feed the classifier head directly; only the input layer dimension is adjusted to the number of features. The $\mathbf{5}$-qubit hybrid model is evaluated under two conditions: with and without principal component analysis (PCA) applied as a preprocessing step to investigate the effect of dimensionality reduction on model performance. In contrast, the 10 -qubit hybrid model is evaluated without PCA, directly processing the input features to explore its capacity to handle higher-dimensional data within the quantum circuit. Performance is measured in terms of classification accuracy, precision, recall, and F1-score. We evaluate the model’s robustness by injecting noise into the training data, finding that the PCA-enhanced hybrid QNN maintains competitive accuracy and resilience under perturbation. This study highlights the potential of PCA-driven variational quantum encodings to enhance QNNs for reliable biomedical data classification.

IEEE International Conference on Recent Advances in Systems Science and Engineering (RASSE)•Nov 4, 2025•0 citations

Parallel Multi-Circuit Quantum Feature Fusion in Hybrid Quantum-Classical Convolutional Neural Networks for Breast Tumor Classification

Ece Yurtseven

Quantum machine learning has emerged as a promising approach to improve feature extraction and classification tasks in high-dimensional data domains such as medical imaging. In this work, we present a hybrid Quantum-Classical Convolutional Neural Network (QCNN) architecture designed for the binary classification of the BreastMNIST dataset, a standardized benchmark for distinguishing between benign and malignant breast tumors. Our architecture integrates classical convolutional feature extraction with two distinct quantum circuits: an amplitude-encoding variational quantum circuit (VQC) and an angle-encoding VQC circuit with circular entanglement, both implemented on four qubits. These circuits generate quantum feature embeddings that are fused with classical features to form a joint feature space, which is subsequently processed by a fully connected classifier. To ensure fairness, the hybrid QCNN is parameter-matched against a baseline classical CNN, allowing us to isolate the contribution of quantum layers. Both models are trained under identical conditions using the Adam optimizer and binary cross-entropy loss. Experimental evaluation in five independent runs demonstrates that the hybrid QCNN achieves statistically significant improvements in classification accuracy compared to the classical CNN, as validated by a one-sided Wilcoxon signed rank test (p = 0.03125) and supported by large effect size of Cohen's d = 2.14. Our results indicate that hybrid QCNN architectures can leverage entanglement and quantum feature fusion to enhance medical image classification tasks. This work establishes a statistical validation framework for assessing hybrid quantum models in biomedical applications and highlights pathways for scaling to larger datasets and deployment on near-term quantum hardware.

quant-pharXiv:2512.02066•International Conference on Quantum Communications, Networking, and Computing (QCNC)•Dec 2, 2025•4 citations

Enhancing Blood Cells Classification using Hybrid Quantum Neural Networks

Guilherme Cruz, Nouhaila Innan, Alberto Marchisio +2 more

Accurate classification of microscopic blood cells is still a critical task in medical image analysis, where subtle variations and limited data can challenge conventional deep learning models. As such, we investigate in this work the potential of Hybrid Quantum-Classical Neural Networks (HQNNs) to enhance feature representation and improve classification performance in this domain. We propose a modular architecture combining a pre-trained ResNet-50 backbone with a low-dimensional latent bottleneck and a variational quantum circuit, enabling a direct comparison between quantum-enhanced and purely classical transformation mechanisms. To isolate the contribution of the quantum component, we evaluate three architectures: a HQNN model, a Classical Matched Model with an additional nonlinear transformation layer of comparable capacity, and a baseline model without an intermediate transformation stage. Experiments conducted on two publicly available blood cell datasets, namely the Blood Cell Images dataset and the PBC dataset, demonstrate that HQNNs consistently achieve superior or more balanced performance across evaluation metrics. In the Blood Cell Images Dataset, the proposed approach improves macro F1-score by up to 3.7% compared to classical baselines, while improving the F1-score from 98.54% to 98.69% in the more challenging 8-class scenario with near-saturated performance. Additional evaluation on IBM quantum hardware shows that the model remains robust under noise, with only a modest performance degradation relative to simulated results. These results indicate that quantum feature transformations can enhance discriminative representations, particularly in challenging classification scenarios, and highlight the practical potential of HQNN models for medical imaging tasks.

cs.CVCross-listedarXiv:2605.23324•May 25, 2026•1 citation
This study presents a reproducible evaluation framework for hybrid quantum-classical neural networks (HQCNNs) in healthcare classification, rather than a new architecture. We assess a four-qubit HQCNN combining a compact classical encoder, a two-layer parameterized quantum circuit (PQC), and a classical readout (441 trainable parameters) against carefully tuned classical baselines on the Wisconsin Diagnostic Breast Cancer (WDBC) dataset under identical five-fold cross-validation. The work is framed as a single-dataset proof-of-concept: the contribution is a documented, shared-fold evaluation protocol with a parameter-matched classical control and a quantified epistemic-informativeness analysis, not a demonstration of general quantum advantage. The HQCNN reached 96.49±1.96% accuracy and 99.44±0.60% ROC-AUC. A parameter-matched classical multilayer perceptron (441 parameters) reached 95.08±1.81% accuracy; the HQCNN’s +1.41 percentage-point edge at equal capacity was not statistically significant (paired t, p=0.056). Across five shared folds, no HQCNN-versus-classical accuracy difference survived Holm–Bonferroni correction (all adjusted p≥0.625), so we report the HQCNN as competitive with, not superior to, strong tuned classical baselines. A multi-split depth ablation showed that circuit depth L∈{1,2,3} had no statistically detectable effect on accuracy (L=2 vs. L=3: Wilcoxon p=1.00); we therefore adopt two variational layers as a practical default rather than an optimum. Under a low-noise simulator (depolarising and amplitude-damping channels, p=0.01), accuracy was 96.49%, indicating robustness only at modest uniform error rates; realistic hardware noise is higher. We additionally apply Bayesian surprise as an epistemic-informativeness heuristic—not a formal generative model—to rank which findings are most worth building on. The framework offers a reproducible, documented evaluation procedure that can support cumulative comparison of hybrid quantum-classical models in healthcare.
Medical image classification is a critical component of modern healthcare; however, accurate diagnosis remains challenging due to limited annotated datasets, class imbalance, and the high dimensionality of medical imaging data. To address these challenges, a hybrid quantum-classical neural network (HQCNN) is proposed, integrating classical deep learning with variational quantum learning for medical image classification. The proposed architecture combines a five-layer convolutional neural network (CNN) for hierarchical feature extraction with a lightweight 4-qubit variational quantum circuit (VQC) incorporating quantum state encoding, superposition and entanglement mechanisms, and a quantum attention-Fourier (QAF) module. This hybrid design aims to improve nonlinear feature representation and quantum parameter efficiency while maintaining a shallow quantum circuit suitable for noisy intermediate-scale quantum (NISQ)-era constraints. Experimental evaluation on six MedMNIST benchmark datasets demonstrated competitive performance across both binary and multi-class classification tasks. HQCNN achieved 98.88% accuracy on the binary subset of PathMNIST (classes 0 vs. 1), 97.61% accuracy on the multi-class OrganAMNIST dataset, and 86.29% accuracy on BreastMNIST. Comparative experiments and statistical analyses demonstrated consistent improvements over the controlled BHQNN baseline, while component-wise ablation studies showed that the QAF module, superposition and entanglement mechanisms, and expressive parameterized rotations contributed to classification performance in a complementary and dataset-dependent manner. Moreover, HQCNN reduced the number of trainable quantum parameters by approximately 55.6% compared with the baseline hybrid quantum neural network (BHQNN). Noise-aware simulations further showed that the model retained relatively stable predictive performance under moderate depolarizing noise, supporting further evaluation under near-term quantum computing conditions. Overall, the results demonstrate that HQCNN provides a parameter-efficient hybrid quantum-classical framework for medical image classification and offers a promising foundation for further investigation of quantum-enhanced medical image analysis.
Classification of medical images plays a vital role in medical image analysis; however, it remains challenging due to the limited availability of labeled data, class imbalances, and the complexity of medical patterns. To overcome these challenges, we propose a novel Hybrid Quantum-Classical Neural Network (HQCNN) for both binary and multi-class classification. The architecture of HQCNN integrates a five-layer classical convolutional backbone with a 4-qubit variational quantum circuit that incorporates quantum state encoding, superpositional entanglement, and a Fourier-inspired quantum attention mechanism. We evaluate the model on six MedMNIST v2 benchmark datasets. The HQCNN consistently outperforms classical and quantum baselines, achieving up to 99.91% accuracy and 100.00% AUC on PathMNIST (binary) and 99.95% accuracy on OrganAMNIST (multi-class) with strong robustness on noisy datasets like BreastMNIST (87.18% accuracy). The model demonstrates superior generalization capability and computational efficiency, accomplished with significantly fewer trainable parameters, making it suitable for data-scarce scenarios. Our findings provide strong empirical evidence that hybrid quantum-classical models can advance medical imaging tasks.
Accurate classification of brain tumors from MRI scans is critical for effective treatment planning. This study presents a Hybrid Quantum Convolutional Neural Network (HQCNN) that integrates quantum feature-encoding circuits with depth-wise separable convolutional layers to analyze images from a publicly available brain tumor dataset. Evaluated on this dataset, the HQCNN achieved 99.16% training accuracy and 91.47% validation accuracy, demonstrating robust performance across varied imaging conditions. The quantum layers capture complex, non-linear relationships, while separable convolutions ensure computational efficiency. By reducing both parameter count and circuit depth, the architecture is compatible with near-term quantum hardware and resource-constrained clinical environments. These results establish a foundation for integrating quantum-enhanced models into medical-imaging workflows with minimal changes to existing software platforms. Future work will extend evaluation to multi-center cohorts, assess real-time inference on quantum simulators and hardware, and explore integration with surgical-planning systems.
Quantum neural networks (QNNs) offer a promising avenue for machine learning by leveraging quantum computation, but practical QNN models are constrained by the low dimensionality of the input data they can handle. This paper proposes a hybrid quantum-classical neural network architecture that incorporates principal component analysis (PCA) for dimensionality reduction and variational quantum circuits (VQC) for quantum feature encoding. Focusing on the Wisconsin Diagnostic Breast Cancer dataset (569 instances, 30 features) as a representative biomedical classification task, in this work, we design hybrid quantum-classical neural network (QNN) models using 5-qubit and 10-qubit quantum circuits. For comparison, we use classical baseline identical to the downstream head but without the VQC+measurement. The preprocessed inputs feed the classifier head directly; only the input layer dimension is adjusted to the number of features. The 5\mathbf{5}5-qubit hybrid model is evaluated under two conditions: with and without principal component analysis (PCA) applied as a preprocessing step to investigate the effect of dimensionality reduction on model performance. In contrast, the 10 -qubit hybrid model is evaluated without PCA, directly processing the input features to explore its capacity to handle higher-dimensional data within the quantum circuit. Performance is measured in terms of classification accuracy, precision, recall, and F1-score. We evaluate the model’s robustness by injecting noise into the training data, finding that the PCA-enhanced hybrid QNN maintains competitive accuracy and resilience under perturbation. This study highlights the potential of PCA-driven variational quantum encodings to enhance QNNs for reliable biomedical data classification.
Quantum machine learning has emerged as a promising approach to improve feature extraction and classification tasks in high-dimensional data domains such as medical imaging. In this work, we present a hybrid Quantum-Classical Convolutional Neural Network (QCNN) architecture designed for the binary classification of the BreastMNIST dataset, a standardized benchmark for distinguishing between benign and malignant breast tumors. Our architecture integrates classical convolutional feature extraction with two distinct quantum circuits: an amplitude-encoding variational quantum circuit (VQC) and an angle-encoding VQC circuit with circular entanglement, both implemented on four qubits. These circuits generate quantum feature embeddings that are fused with classical features to form a joint feature space, which is subsequently processed by a fully connected classifier. To ensure fairness, the hybrid QCNN is parameter-matched against a baseline classical CNN, allowing us to isolate the contribution of quantum layers. Both models are trained under identical conditions using the Adam optimizer and binary cross-entropy loss. Experimental evaluation in five independent runs demonstrates that the hybrid QCNN achieves statistically significant improvements in classification accuracy compared to the classical CNN, as validated by a one-sided Wilcoxon signed rank test (p = 0.03125) and supported by large effect size of Cohen's d = 2.14. Our results indicate that hybrid QCNN architectures can leverage entanglement and quantum feature fusion to enhance medical image classification tasks. This work establishes a statistical validation framework for assessing hybrid quantum models in biomedical applications and highlights pathways for scaling to larger datasets and deployment on near-term quantum hardware.
Accurate classification of microscopic blood cells is still a critical task in medical image analysis, where subtle variations and limited data can challenge conventional deep learning models. As such, we investigate in this work the potential of Hybrid Quantum-Classical Neural Networks (HQNNs) to enhance feature representation and improve classification performance in this domain. We propose a modular architecture combining a pre-trained ResNet-50 backbone with a low-dimensional latent bottleneck and a variational quantum circuit, enabling a direct comparison between quantum-enhanced and purely classical transformation mechanisms. To isolate the contribution of the quantum component, we evaluate three architectures: a HQNN model, a Classical Matched Model with an additional nonlinear transformation layer of comparable capacity, and a baseline model without an intermediate transformation stage. Experiments conducted on two publicly available blood cell datasets, namely the Blood Cell Images dataset and the PBC dataset, demonstrate that HQNNs consistently achieve superior or more balanced performance across evaluation metrics. In the Blood Cell Images Dataset, the proposed approach improves macro F1-score by up to 3.7% compared to classical baselines, while improving the F1-score from 98.54% to 98.69% in the more challenging 8-class scenario with near-saturated performance. Additional evaluation on IBM quantum hardware shows that the model remains robust under noise, with only a modest performance degradation relative to simulated results. These results indicate that quantum feature transformations can enhance discriminative representations, particularly in challenging classification scenarios, and highlight the practical potential of HQNN models for medical imaging tasks.