Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement

AC-driven temperature measurement of vapor cell in a compact atomic magnetometer with suppressed thermometry-induced magnetic interference

Zhendong Wu, Di Wu, Tengyue Long, Le Jia, Wenhao Guan, Jing Zhang, Zhuo Wang, Xusheng Lei, Xinda Song

Published Jun 1, 2026• 0 citations
Publisher
DOI
10.1016/j.measurement.2026.122039

Related papers

Compact Mz atomic magnetometer with a thick silicon core MEMS vapor cell

Qi Li, Jianan Qin, Yuejin Jiang +2 more

Optics Communications•Jul 14, 2024•5 citations

Laser Heating Method for an Alkali Metal Atomic Cell with Heat Transfer Enhancement

Yang Li, Guoqing Zhou, Shencheng Tian +3 more

Alkali metal atomic cells are crucial components of atomic instruments, such as atomic magnetometers, atomic gyroscopes, and atomic clocks. A highly uniform and stable heating structure can ensure the stability of the alkali metal atom density. The vapor cell of an atomic magnetometer that uses laser heating has no magnetic field interference and ease of miniaturization, making it superior to hot air heating and AC electric heating. However, the current laser heating structure suffers from low heating efficiency and uneven temperature distribution inside the vapor cell. In this paper, we designed a non-magnetic heating structure based on the laser heating principle. We studied the temperature distribution of the heating structure using the finite element method (FEM) and analyzed the conversion and transfer of laser energy. We found that the heat conduction between the vapor cell and the heating chips (colored filters) is poor, resulting in uneven temperature distribution and low heating efficiency in the vapor cell. Therefore, the addition of graphite film to the four surfaces of the vapor cell was an important improvement. This addition helped to balance the temperature distribution and improve the conduction efficiency of the heating structure. It was measured that the power of the heating laser remained unchanged. After the addition of the graphite film, the temperature difference coefficient (CVT) used to evaluate the internal temperature uniformity of the vapor cell was reduced from 0.1308 to 0.0426. This research paper is crucial for improving the heating efficiency of the non-magnetic heating structure and the temperature uniformity of the vapor cell.

Photonics•Jun 1, 2023•14 citations

Zero-field atomic magnetometer unaffected by longitudinal magnetic field interference

Di Zhan, Yaoguo Wang, Ziao Liu +3 more

Measurement•Mar 18, 2026•0 citations

Impact of Thermal Induced Magnetic Noise on the Sensitivity of Atomic Magnetometers

Ning Zhang, Zixuan Wang, Qiang Guo

•Jan 1, 2025•0 citations

Design of Compact Optically Pumped Vector Magnetometer

Rai, Newton

The Svenja and Regal research groups are collaboratively advancing the development of scalar and vector magnetometers, including integrated vector-scalar systems. This thesis focuses on designing a compact optically pumped vector magnetometer (COPVM) that measures the orientation of the magnetic field through Rabi frequencymeasurements driven by a microwave field, serving as an electromagnetic vector reference, across multiple atomic transitions. We transformed a large optical table setup for the vector magnetometer, designed by Cindy's group, into a 20 cm by 10 cm rectangular optical breadboard, designing and fabricating essential components like optical mounts, a microwave cavity, a thermal oven, Kapton heaters, and photodiode electronics to meet the dimensional constraints of COPVMs. To improve temperature uniformity in the vapor cell, we propose a novel cylindrical oven design supported by thermal simulations and in-situ experimental measurements of the vapor cell's heating temperature. We also designed a low-magnetic polyimide heater to mitigate magnetic field interference caused by conventional electrical heating elements. Additionally, we developed a compact cubic dielectric cavity (15 x 15 x 15 mm) with feeding loop antennas as a microwave source to drive various hyperfine 87Rb transitions (σ± and π). This project analyzes miniaturization challenges for the compact physics package (CPP) and its impact on size, weight, and power (SWaP), aiming to maintain optimal functionality. Components like optics mounts and microwave cavities are fabricated from nonmetallic materials using advanced techniques such as selective laser sintering (SLS) and CNC machining, which reduce magnetic interference and enhance structural alignment. This approach also allows for customization and rapid adjustments, supporting flexible prototyping and optimization. This thesis provides a roadmap for designing a compact optically pumped vector magnetometer, addressing key challenges and laying the foundation for future advancements in miniaturized atomic sensors.

•Dec 3, 2024•0 citations

In-Situ Measurement of Electrical-Heating-Induced Magnetic Field for an Atomic Magnetometer

Jixi Lu, Jing Wang, Ke Yang +4 more

Electrical heating elements, which are widely used to heat the vapor cell of ultrasensitive atomic magnetometers, inevitably produce a magnetic field interference. In this paper, we propose a novel measurement method of the amplitude of electrical-heating-induced magnetic field for an atomic magnetometer. In contrast to conventional methods, this method can be implemented in the atomic magnetometer itself without the need for extra magnetometers. It can distinguish between different sources of magnetic fields sensed by the atomic magnetometer, and measure the three-axis components of the magnetic field generated by the electrical heater and the temperature sensor. The experimental results demonstrate that the measurement uncertainty of the heater’s magnetic field is less than 0.2 nT along the x-axis, 1.0 nT along the y-axis, and 0.4 nT along the z-axis. The measurement uncertainty of the temperature sensor’s magnetic field is less than 0.02 nT along all three axes. This method has the advantage of measuring the in-situ magnetic field, so it is especially suitable for miniaturized and chip-scale atomic magnetometers, where the cell is extremely small and in close proximity to the heater and the temperature sensor.

Sensors•Mar 25, 2020•39 citations
Alkali metal atomic cells are crucial components of atomic instruments, such as atomic magnetometers, atomic gyroscopes, and atomic clocks. A highly uniform and stable heating structure can ensure the stability of the alkali metal atom density. The vapor cell of an atomic magnetometer that uses laser heating has no magnetic field interference and ease of miniaturization, making it superior to hot air heating and AC electric heating. However, the current laser heating structure suffers from low heating efficiency and uneven temperature distribution inside the vapor cell. In this paper, we designed a non-magnetic heating structure based on the laser heating principle. We studied the temperature distribution of the heating structure using the finite element method (FEM) and analyzed the conversion and transfer of laser energy. We found that the heat conduction between the vapor cell and the heating chips (colored filters) is poor, resulting in uneven temperature distribution and low heating efficiency in the vapor cell. Therefore, the addition of graphite film to the four surfaces of the vapor cell was an important improvement. This addition helped to balance the temperature distribution and improve the conduction efficiency of the heating structure. It was measured that the power of the heating laser remained unchanged. After the addition of the graphite film, the temperature difference coefficient (CVT) used to evaluate the internal temperature uniformity of the vapor cell was reduced from 0.1308 to 0.0426. This research paper is crucial for improving the heating efficiency of the non-magnetic heating structure and the temperature uniformity of the vapor cell.
The Svenja and Regal research groups are collaboratively advancing the development of scalar and vector magnetometers, including integrated vector-scalar systems. This thesis focuses on designing a compact optically pumped vector magnetometer (COPVM) that measures the orientation of the magnetic field through Rabi frequencymeasurements driven by a microwave field, serving as an electromagnetic vector reference, across multiple atomic transitions. We transformed a large optical table setup for the vector magnetometer, designed by Cindy's group, into a 20 cm by 10 cm rectangular optical breadboard, designing and fabricating essential components like optical mounts, a microwave cavity, a thermal oven, Kapton heaters, and photodiode electronics to meet the dimensional constraints of COPVMs. To improve temperature uniformity in the vapor cell, we propose a novel cylindrical oven design supported by thermal simulations and in-situ experimental measurements of the vapor cell's heating temperature. We also designed a low-magnetic polyimide heater to mitigate magnetic field interference caused by conventional electrical heating elements. Additionally, we developed a compact cubic dielectric cavity (15 x 15 x 15 mm) with feeding loop antennas as a microwave source to drive various hyperfine 87Rb transitions (σ± and π). This project analyzes miniaturization challenges for the compact physics package (CPP) and its impact on size, weight, and power (SWaP), aiming to maintain optimal functionality. Components like optics mounts and microwave cavities are fabricated from nonmetallic materials using advanced techniques such as selective laser sintering (SLS) and CNC machining, which reduce magnetic interference and enhance structural alignment. This approach also allows for customization and rapid adjustments, supporting flexible prototyping and optimization. This thesis provides a roadmap for designing a compact optically pumped vector magnetometer, addressing key challenges and laying the foundation for future advancements in miniaturized atomic sensors.
Electrical heating elements, which are widely used to heat the vapor cell of ultrasensitive atomic magnetometers, inevitably produce a magnetic field interference. In this paper, we propose a novel measurement method of the amplitude of electrical-heating-induced magnetic field for an atomic magnetometer. In contrast to conventional methods, this method can be implemented in the atomic magnetometer itself without the need for extra magnetometers. It can distinguish between different sources of magnetic fields sensed by the atomic magnetometer, and measure the three-axis components of the magnetic field generated by the electrical heater and the temperature sensor. The experimental results demonstrate that the measurement uncertainty of the heater’s magnetic field is less than 0.2 nT along the x-axis, 1.0 nT along the y-axis, and 0.4 nT along the z-axis. The measurement uncertainty of the temperature sensor’s magnetic field is less than 0.02 nT along all three axes. This method has the advantage of measuring the in-situ magnetic field, so it is especially suitable for miniaturized and chip-scale atomic magnetometers, where the cell is extremely small and in close proximity to the heater and the temperature sensor.