Satellite Microwave Detection via Cavity-Coupled Rydberg Atomic Receiver

Mingwei Lei, Meng Shi

Published Jan 1, 2026• 1 citation
Publisher

Abstract

Due to the small interaction region between Rydberg atoms and the microwave field, it is difficult to detect weak satellite signals using free-space-coupled atomic receivers. In this work, we introduce a cavity-coupled Rydberg atomic receiver to enhance the microwave field and combine it with a passive antenna to detect C-band satellite signals. Using microwave-atom enhanced coupling, the minimum detectable power of incident microwave is reduced to -128 dBm, and the corresponding sensitivity sensing by atoms is estimated as 21 nV/cm/Hz1/2at a frequency of 3.80 GHz. Furthermore, we also show the effectiveness of this scheme by capturing the beacon signal from a geostationary satellite, without the need for low-noise amplifiers often used in conventional detection. Besides, modulated satellite signals are received with a signal-to-noise ratio of 8 dB with a measurement bandwidth of 10 Hz. Our results demonstrate an advancement in facilitating satellite communications using cavity-coupled Rydberg-atom receivers.

DOI
10.1109/tqe.2026.3690617

Related papers

Satellite Signal Detection via Rydberg-Atom Receiver

Mignwei Lei, Zhang, Jianquan, Luo, Qun +3 more

Rydberg-atom receivers aim for ultra-high sensitivity to microwave fields through various techniques, but receiving satellite signals has remained a significant challenge, due to the difficulty of capturing weak microwaves over long distances. In this work, we introduce a high-gain antenna to focus satellite signals, and then apply into an atomic cell via a microwave cavity. Using microwave-enhanced coupling, the minimum detectable power of incident microwave is down to -128 dBm, and the corresponding sensitivity is estimated as 21 nV/cm/Hz1/2 at frequency of 3.80 GHz. Furthermore, beacon signal from geostationary satellites is captured with Rydberg sensors for the first time, without the need for a low-noise amplifier. And C-band modulated signals are read out with a signal-to-noise ratio of 8 dB. Our results mark a significant breakthrough in facilitating satellite communications using Rydberg-atom receivers.

arXiv:2506.15439•Jun 18, 2025•1 citation

Sensitivity Enhancement of S-Band Rydberg Atom Microwave Receiver Using Resonant Cavity

Yipeng Xie, Xinbing Chen, Mingwei Lei +1 more

Rydberg atom-based microwave electric field sensing has attracted growing interest owing to its inherent advantages, such as absolute calibration, wideband operability, and compatibility with room-temperature devices. A critical bottleneck that limits sensitivity is the inefficient coupling between the Rydberg atoms and the incident microwave field, particularly when detecting weak signals propagating in free space. Here we propose and experimentally validate a scheme that integrates a horn antenna with a resonant microwave cavity to significantly improve this coupling for free-space signal reception in the S-band. Using a two-photon excitation scheme in a cesium vapor cell, we systematically characterize the sensing performance under three configurations: a bare cell, direct cavity injection, and a cavity coupled to a horn antenna that captures free-space microwave signals over a 1 m distance. In the antenna-coupled cavity configuration, we achieve an optimal sensitivity of 2.33 nV/cm/$\sqrt{\text{Hz}}$ at the receiving antenna, which corresponds to an enhancement of approximately 17.9 dB compared to the optimized bare vapor cell configuration. Our findings offer a practical and effective route to boost the sensitivity of Rydberg atomic sensors, facilitating their adoption in real-world microwave metrology and wireless communication applications where weak free-space electric fields must be reliably measured.

physics.atom-phCross-listedarXiv:2606.02669•Optics Express•Jun 2, 2026•1 citation

Cavity-enhanced Rydberg atomic superheterodyne receiver

Yukang Liang, Qinxia Wang, Zhi‐Hui Wang +7 more

High-sensitivity measurements of the microwave electric field are important in applications of communication and metrology. The sensitivity of traditional Rydberg superheterodyne receivers in free space is effectively determined by the signal-to-noise ratio (SNR), which is often considered equivalent to sensitivity in practical sensing applications. In this work, we demonstrate a cavity-enhanced receiver, where an optical cavity significantly amplifies the interaction between the probe light and cesium atoms, which substantially improves the signal-to-noise ratio via enhancing the expansion coefficient κ . Here, κ is the edge slope of the single peak obtained by fitting the double-peak EIT-AT spectrum, characterizing the response of the probe light to the frequency detuning of the coupling laser. The sensitivity is thus boosted by a factor of approximately 19 dB. This study highlights the pivotal role of optical cavities in advancing Rydberg-based detection systems, offering a promising approach for high-sensitivity microwave electric field measurements.

arXiv:2502.20792•Optics Express•Mar 4, 2025•11 citations

Enhancing Sensitivity of an Atomic Microwave Receiver via a Fabry-Perot Cavity

Bo Wu, Dunwei Liao, Di Sang +2 more

Rydberg atom-based microwave (MW) atomic receiver is regarded as a promising atomic receiver to surpass the sensitivity of conventional receivers. This article proposes a tunable Fabry-Perot (FP) cavity that locally enhances the MW electric (E) field to improve measurement sensitivities. This FP cavity includes a 0.9947 reflection coefficient periodic metal slit structure and a reflective plate. In our experiment, 21-dB signal-to-noise ratio (SNR) enhancement is achieved by utilizing the FP cavity. Ultimately, the atomic receiver loaded with a FP cavity provides a sensitivity of$ \mathbf {5 \mathbf {nv/cm/\sqrt {Hz}}}$@8.57 GHz that is the most advanced sensitivity known based on$\mathbf {^{133}\textrm {Cs}}$resonant transition$\mathbf {|44D_{5/2}\rangle \rightarrow |45P_{3/2}\rangle }$. Since the FP cavity is different from the traditional closed cavity and split-ring resonance mechanism, a large enhancement tunable frequency bandwidth of 4.8–12.2 GHz can be achieved by adjusting the plate spacing. In addition, the FP cavity solves the direct coupling between the electromagnetic wave and the resonator in the X-band, which provides mobility and flexibility. We take all the vapor cell wall’s refractive index and metal reflections into account as the resonance-based system is more sensitive to errors.

IEEE Transactions on Antennas and Propagation•Oct 21, 2024•36 citations

Cavity-Enhanced Rydberg Atom Microwave Receiver

Bang Liu, Lihua Zhang, Qifeng Wang +11 more

Abstract Developing microwave electric field sensing based on Rydberg atoms has received significant attention due to its unique advantages. However, achieving effective coupling between Rydberg atoms and the microwave electric field in the sensing process is a challenging problem that greatly impacts the sensitivity. To address this, we propose using a microwave resonant cavity to enhance the effective coupling between the Rydberg atoms and the microwave electric field. In our experiment, Rydberg atoms are prepared via a three-photon excitation scheme, and the electric fields are measured without and with a microwave cavity in which the vapor cell is placed inside, respectively. As a result, we achieved an 18 dB enhancement of power sensitivity by adding the cavity, which is an effective enhancement in electric field pulse signal detection. This experimental testing provides a promising direction for enhancing the sensitivity of Rydberg atomic electric field sensors and paves the way for their application in precision electric field measurements.

arXiv:2404.06915•Chinese Physics Letters•Apr 7, 2025•32 citations

Sensitivity enhancement in Rydberg atomic microwave superheterodyne measurements through laser-atom-microwave interaction mechanisms

Zhongzhou Tian, Guojin Zeng, Chao Yan +3 more

Measurement sensitivity is crucial for the practical application of Rydberg atomic microwave superheterodyne receiver systems in communication, radar, and navigation. Based on laser-atom-microwave interaction mechanisms, the influence of laser powers and local-oscillator (LO) microwave field intensity on measurement sensitivity is systematically studied in this paper. Measurement sensitivity is analyzed through electromagnetically induced transparency (EIT) spectral characteristics, specifically EIT amplitude and full-width-half-maximum (FWHM),larger amplitudes and narrower FWHM indicate improved signal-to-noise ratios. For a 60D-state Rydberg atomic system with fixed probe and coupling laser beam waists (800 µm and 875 µm), optimal parameters are determined: probe laser power of 60 µW(Rabi frequency: 2π×7.02 MHz), coupling laser power of 40 mW (Rabi frequency: 2π×0.66 MHz), and LO microwave Rabi frequency of 2π×8.34 MHz. Experimental results demonstrate a 4.6 dB sensitivity enhancement, advancing from −137.5dBm/Hz to −142.1 dBm/Hz at 3.21 GHz microwave field. This improvement is attributed to precise alignment of laser-atom and microwave-atom interactions, bridging the gap toward quantum sensitivity limits.

Applied Optics and Photonics China (AOPC)•Oct 28, 2025•0 citations
Due to the small interaction region between Rydberg atoms and the microwave field, it is difficult to detect weak satellite signals using free-space-coupled atomic receivers. In this work, we introduce a cavity-coupled Rydberg atomic receiver to enhance the microwave field and combine it with a passive antenna to detect C-band satellite signals. Using microwave-atom enhanced coupling, the minimum detectable power of incident microwave is reduced to -128 dBm, and the corresponding sensitivity sensing by atoms is estimated as 21 nV/cm/Hz1/2at a frequency of 3.80 GHz. Furthermore, we also show the effectiveness of this scheme by capturing the beacon signal from a geostationary satellite, without the need for low-noise amplifiers often used in conventional detection. Besides, modulated satellite signals are received with a signal-to-noise ratio of 8 dB with a measurement bandwidth of 10 Hz. Our results demonstrate an advancement in facilitating satellite communications using cavity-coupled Rydberg-atom receivers.
Rydberg-atom receivers aim for ultra-high sensitivity to microwave fields through various techniques, but receiving satellite signals has remained a significant challenge, due to the difficulty of capturing weak microwaves over long distances. In this work, we introduce a high-gain antenna to focus satellite signals, and then apply into an atomic cell via a microwave cavity. Using microwave-enhanced coupling, the minimum detectable power of incident microwave is down to -128 dBm, and the corresponding sensitivity is estimated as 21 nV/cm/Hz1/2 at frequency of 3.80 GHz. Furthermore, beacon signal from geostationary satellites is captured with Rydberg sensors for the first time, without the need for a low-noise amplifier. And C-band modulated signals are read out with a signal-to-noise ratio of 8 dB. Our results mark a significant breakthrough in facilitating satellite communications using Rydberg-atom receivers.
Rydberg atom-based microwave electric field sensing has attracted growing interest owing to its inherent advantages, such as absolute calibration, wideband operability, and compatibility with room-temperature devices. A critical bottleneck that limits sensitivity is the inefficient coupling between the Rydberg atoms and the incident microwave field, particularly when detecting weak signals propagating in free space. Here we propose and experimentally validate a scheme that integrates a horn antenna with a resonant microwave cavity to significantly improve this coupling for free-space signal reception in the S-band. Using a two-photon excitation scheme in a cesium vapor cell, we systematically characterize the sensing performance under three configurations: a bare cell, direct cavity injection, and a cavity coupled to a horn antenna that captures free-space microwave signals over a 1 m distance. In the antenna-coupled cavity configuration, we achieve an optimal sensitivity of 2.33 nV/cm/Hz\sqrt{\text{Hz}}Hz​ at the receiving antenna, which corresponds to an enhancement of approximately 17.9 dB compared to the optimized bare vapor cell configuration. Our findings offer a practical and effective route to boost the sensitivity of Rydberg atomic sensors, facilitating their adoption in real-world microwave metrology and wireless communication applications where weak free-space electric fields must be reliably measured.
High-sensitivity measurements of the microwave electric field are important in applications of communication and metrology. The sensitivity of traditional Rydberg superheterodyne receivers in free space is effectively determined by the signal-to-noise ratio (SNR), which is often considered equivalent to sensitivity in practical sensing applications. In this work, we demonstrate a cavity-enhanced receiver, where an optical cavity significantly amplifies the interaction between the probe light and cesium atoms, which substantially improves the signal-to-noise ratio via enhancing the expansion coefficient κ . Here, κ is the edge slope of the single peak obtained by fitting the double-peak EIT-AT spectrum, characterizing the response of the probe light to the frequency detuning of the coupling laser. The sensitivity is thus boosted by a factor of approximately 19 dB. This study highlights the pivotal role of optical cavities in advancing Rydberg-based detection systems, offering a promising approach for high-sensitivity microwave electric field measurements.
Rydberg atom-based microwave (MW) atomic receiver is regarded as a promising atomic receiver to surpass the sensitivity of conventional receivers. This article proposes a tunable Fabry-Perot (FP) cavity that locally enhances the MW electric (E) field to improve measurement sensitivities. This FP cavity includes a 0.9947 reflection coefficient periodic metal slit structure and a reflective plate. In our experiment, 21-dB signal-to-noise ratio (SNR) enhancement is achieved by utilizing the FP cavity. Ultimately, the atomic receiver loaded with a FP cavity provides a sensitivity of$ \mathbf {5 \mathbf {nv/cm/\sqrt {Hz}}}@8.57GHzthatisthemostadvancedsensitivityknownbasedon@8.57 GHz that is the most advanced sensitivity known based on@8.57GHzthatisthemostadvancedsensitivityknownbasedon\mathbf {^{133}\textrm {Cs}}resonanttransitionresonant transitionresonanttransition\mathbf {|44D_{5/2}\rangle \rightarrow |45P_{3/2}\rangle }$. Since the FP cavity is different from the traditional closed cavity and split-ring resonance mechanism, a large enhancement tunable frequency bandwidth of 4.8–12.2 GHz can be achieved by adjusting the plate spacing. In addition, the FP cavity solves the direct coupling between the electromagnetic wave and the resonator in the X-band, which provides mobility and flexibility. We take all the vapor cell wall’s refractive index and metal reflections into account as the resonance-based system is more sensitive to errors.
Abstract Developing microwave electric field sensing based on Rydberg atoms has received significant attention due to its unique advantages. However, achieving effective coupling between Rydberg atoms and the microwave electric field in the sensing process is a challenging problem that greatly impacts the sensitivity. To address this, we propose using a microwave resonant cavity to enhance the effective coupling between the Rydberg atoms and the microwave electric field. In our experiment, Rydberg atoms are prepared via a three-photon excitation scheme, and the electric fields are measured without and with a microwave cavity in which the vapor cell is placed inside, respectively. As a result, we achieved an 18 dB enhancement of power sensitivity by adding the cavity, which is an effective enhancement in electric field pulse signal detection. This experimental testing provides a promising direction for enhancing the sensitivity of Rydberg atomic electric field sensors and paves the way for their application in precision electric field measurements.
Measurement sensitivity is crucial for the practical application of Rydberg atomic microwave superheterodyne receiver systems in communication, radar, and navigation. Based on laser-atom-microwave interaction mechanisms, the influence of laser powers and local-oscillator (LO) microwave field intensity on measurement sensitivity is systematically studied in this paper. Measurement sensitivity is analyzed through electromagnetically induced transparency (EIT) spectral characteristics, specifically EIT amplitude and full-width-half-maximum (FWHM),larger amplitudes and narrower FWHM indicate improved signal-to-noise ratios. For a 60D-state Rydberg atomic system with fixed probe and coupling laser beam waists (800 µm and 875 µm), optimal parameters are determined: probe laser power of 60 µW(Rabi frequency: 2π×7.02 MHz), coupling laser power of 40 mW (Rabi frequency: 2π×0.66 MHz), and LO microwave Rabi frequency of 2π×8.34 MHz. Experimental results demonstrate a 4.6 dB sensitivity enhancement, advancing from −137.5dBm/Hz to −142.1 dBm/Hz at 3.21 GHz microwave field. This improvement is attributed to precise alignment of laser-atom and microwave-atom interactions, bridging the gap toward quantum sensitivity limits.