Optics Letters

Closed-loop atomic spin gyroscope via injection current modulation and magnetic feedback

Xiaoping Li, Wenfeng Fan, Shimiao Fan, Wei Quan

Published Apr 30, 2026• 0 citations
Publisher

Abstract

In traditional spin-exchange relaxation-free (SERF) gyroscopes, open-loop detection leaves the scale factor vulnerable to fluctuations in probe laser intensity and environmental temperature. To address this, an external-modulator-free closed-loop atomic spin gyroscope (ASG) is demonstrated using direct probe laser injection current modulation. A magnetic feedback loop maintains the total optical rotation at a zero point, decoupling the inertial signal from intensity and optical depth variations. Experimental results demonstrate a closed-loop rotation sensitivity of 2.8×10 −6 °/s/Hz 1/2 at 1 Hz. Compared to open-loop measurements under identical conditions (1×10 −5 ∘ /s/Hz 1/2 ), low-frequency noise is significantly suppressed. By eliminating bulky external modulators and effectively suppressing low-frequency noise, this design offers a highly competitive architecture for miniaturized atomic inertial sensors.

DOI
10.1364/ol.600447

Related papers

Real-Time In Situ Quantum Feedback Control of Electron Spin in Atomic Spin Gyroscopes

Hongyu Pei, Wei Quan, Linlin Yuan +4 more

The atomic spin gyroscope (ASG), based on spin-exchange relaxation-free (SERF) co-magnetometers, is poised to become the next generation of high-precision inertial sensors. However, the long-term stability of the gyro can be limited by electron spin polarization. In this study, we investigate a novel real-time, in situ quantum feedback control technique for electron spin polarization in ASGs. By varying the pumping rates, we analyze the gyroscope’s response to the modulation magnetic field, finding that electron polarization dramatically affects the magnetic field response properties of ASGs. It’s demonstrated that the amplitude or phase of the electron spin resonance can be locked for in situ control of electron spin polarization in real-time. A K-Rb-21Ne co-magnetometer is established to implement the proposed method, where a transverse modulating magnetic field is applied to resonate with the electron spin. The lock-in amplification (LIA) technique is used to obtain the amplitude or phase of the electron spin resonance, and the electron spin polarization is closed-loop controlled by locking the second harmonic resonance amplitude or phase. The gyro signal is extracted from the first harmonic of the electron spin resonance. Our experimental results show that real-time in situ feedback control of electron spin significantly improves ASG’s long-term stability and suppresses low-frequency noise. This proposed method has broad application prospects, including optically pumped magnetometers (OPMs), nuclear magnetic resonance gyroscopes (NMRGs), and co-magnetometers.

IEEE Transactions on Instrumentation and Measurement•Oct 18, 2023•31 citations

Spin-exchange relaxation-free magnetic gradiometer with dual-beam and closed-loop Faraday modulation

Jiancheng Fang, Shuangai Wan, Jie Qin +2 more

Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.

Journal of the Optical Society of America B•Feb 12, 2014•24 citations

A novel Cs-129Xe atomic spin gyroscope with closed-loop Faraday modulation

Jiancheng Fang, Shuangai Wan, Jie Qin +4 more

We report a novel Cs-(129)Xe atomic spin gyroscope (ASG) with closed-loop Faraday modulation method. This ASG requires approximately 30 min to start-up and 110 °C to operate. A closed-loop Faraday modulation method for measurement of the optical rotation was used in this ASG. This method uses an additional Faraday modulator to suppress the laser intensity fluctuation and Faraday modulator thermal induced fluctuation. We theoretically and experimentally validate this method in the Cs-(129)Xe ASG and achieved a bias stability of approximately 3.25 °∕h.

Review of Scientific Instruments•Aug 1, 2013•41 citations

Low drift nuclear spin gyroscope with probe light intensity error suppression*

Wenfeng Fan, Wei Quan, Feng Liu +2 more

A nuclear spin gyroscope based on an alkali-metal–noble-gas co-magnetometer operated in spin-exchange relaxation-free (SERF) regime is a promising atomic rotation sensor for its ultra-high fundamental sensitivity. However, the fluctuation of probe light intensity is one of the main technical error sources that limits the bias stability of the gyroscope. Here we propose a novel method to suppress the bias error induced by probe light intensity fluctuations. This method is based on the inherent magnetic field response characteristics of the gyroscope. By the application of a bias magnetic field, the gyroscope can be tuned to a working point where the output signal is insensitive to probe light intensity variation, referred to herein as ‘zero point’, thus the bias error induced by intensity fluctuations can be completely suppressed. The superiority of the method was verified on a K–Rb–21Ne co-magnetometer, and a bias stability of approximately 0.01 °/h was obtained. In addition, the method proposed here can remove the requirement of the closed-loop control of probe light intensity, thereby facilitating miniaturization of the gyroscope volume and improvement of reliability.

Chinese Physics B•Sep 18, 2019•22 citations

Dual-Axis Closed Loop of a Single-Beam Atomic Magnetometer: Toward High Bandwidth and High Sensitivity

Junjian Tang, Yueyang Zhai, Binquan Zhou +2 more

Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2021•95 citations

Closed-loop atomic spin polarization detection based on EOAM modulation in K-Rb-21Ne co-magnetometers

Shimiao Fan, Wenfeng Fan, Qi Yuan +4 more

We propose a high-sensitivity spin polarization detection scheme based on optical amplitude modulation in atomic co-magnetometers, which is different from the traditional configuration.A linearly polarized laser with intensity modulation interacts with electron spins, generating optical rotation angles.Through differential amplification and demodulation, atomic spin polarization information is extracted with high precision.The effectiveness of the proposed method is verified by applying external perturbations during testing.Compared to traditional detection methods, the proposed approach effectively enhances inertial measurement sensitivity.Specifically, at 1 Hz, the measurement sensitivity has improved from 9.7 × 10 -6 to 3.25 × 10 -6 deg/(s Hz 1/2 ).Furthermore, the proposed scheme is easily integrable and conducive to future research on miniaturizing co-magnetometers and can also be applied to many other related fields.

Chinese Optics Letters•Jan 1, 2024•4 citations
In traditional spin-exchange relaxation-free (SERF) gyroscopes, open-loop detection leaves the scale factor vulnerable to fluctuations in probe laser intensity and environmental temperature. To address this, an external-modulator-free closed-loop atomic spin gyroscope (ASG) is demonstrated using direct probe laser injection current modulation. A magnetic feedback loop maintains the total optical rotation at a zero point, decoupling the inertial signal from intensity and optical depth variations. Experimental results demonstrate a closed-loop rotation sensitivity of 2.8×10 −6 °/s/Hz 1/2 at 1 Hz. Compared to open-loop measurements under identical conditions (1×10 −5 ∘ /s/Hz 1/2 ), low-frequency noise is significantly suppressed. By eliminating bulky external modulators and effectively suppressing low-frequency noise, this design offers a highly competitive architecture for miniaturized atomic inertial sensors.
The atomic spin gyroscope (ASG), based on spin-exchange relaxation-free (SERF) co-magnetometers, is poised to become the next generation of high-precision inertial sensors. However, the long-term stability of the gyro can be limited by electron spin polarization. In this study, we investigate a novel real-time, in situ quantum feedback control technique for electron spin polarization in ASGs. By varying the pumping rates, we analyze the gyroscope’s response to the modulation magnetic field, finding that electron polarization dramatically affects the magnetic field response properties of ASGs. It’s demonstrated that the amplitude or phase of the electron spin resonance can be locked for in situ control of electron spin polarization in real-time. A K-Rb-21Ne co-magnetometer is established to implement the proposed method, where a transverse modulating magnetic field is applied to resonate with the electron spin. The lock-in amplification (LIA) technique is used to obtain the amplitude or phase of the electron spin resonance, and the electron spin polarization is closed-loop controlled by locking the second harmonic resonance amplitude or phase. The gyro signal is extracted from the first harmonic of the electron spin resonance. Our experimental results show that real-time in situ feedback control of electron spin significantly improves ASG’s long-term stability and suppresses low-frequency noise. This proposed method has broad application prospects, including optically pumped magnetometers (OPMs), nuclear magnetic resonance gyroscopes (NMRGs), and co-magnetometers.
Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.
We report a novel Cs-(129)Xe atomic spin gyroscope (ASG) with closed-loop Faraday modulation method. This ASG requires approximately 30 min to start-up and 110 °C to operate. A closed-loop Faraday modulation method for measurement of the optical rotation was used in this ASG. This method uses an additional Faraday modulator to suppress the laser intensity fluctuation and Faraday modulator thermal induced fluctuation. We theoretically and experimentally validate this method in the Cs-(129)Xe ASG and achieved a bias stability of approximately 3.25 °∕h.
A nuclear spin gyroscope based on an alkali-metal–noble-gas co-magnetometer operated in spin-exchange relaxation-free (SERF) regime is a promising atomic rotation sensor for its ultra-high fundamental sensitivity. However, the fluctuation of probe light intensity is one of the main technical error sources that limits the bias stability of the gyroscope. Here we propose a novel method to suppress the bias error induced by probe light intensity fluctuations. This method is based on the inherent magnetic field response characteristics of the gyroscope. By the application of a bias magnetic field, the gyroscope can be tuned to a working point where the output signal is insensitive to probe light intensity variation, referred to herein as ‘zero point’, thus the bias error induced by intensity fluctuations can be completely suppressed. The superiority of the method was verified on a K–Rb–21Ne co-magnetometer, and a bias stability of approximately 0.01 °/h was obtained. In addition, the method proposed here can remove the requirement of the closed-loop control of probe light intensity, thereby facilitating miniaturization of the gyroscope volume and improvement of reliability.
Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.
We propose a high-sensitivity spin polarization detection scheme based on optical amplitude modulation in atomic co-magnetometers, which is different from the traditional configuration.A linearly polarized laser with intensity modulation interacts with electron spins, generating optical rotation angles.Through differential amplification and demodulation, atomic spin polarization information is extracted with high precision.The effectiveness of the proposed method is verified by applying external perturbations during testing.Compared to traditional detection methods, the proposed approach effectively enhances inertial measurement sensitivity.Specifically, at 1 Hz, the measurement sensitivity has improved from 9.7 × 10 -6 to 3.25 × 10 -6 deg/(s Hz 1/2 ).Furthermore, the proposed scheme is easily integrable and conducive to future research on miniaturizing co-magnetometers and can also be applied to many other related fields.