Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Electron Device Letters

Design of Unidirectional Broadband Circularly Polarized Resonator With Integrated Local Oscillator for Rydberg Atomic Receiver

Yuxiao Li, Yi Lin, Kai Yang, Ruibing Ran, Qiang An, Dan Wen, Yunqi Fu

Published Apr 27, 2026• 1 citation
Publisher

Abstract

The high-efficiency Rydberg field probe (RFP), as the core of Rydberg atomic receivers, has at tracted widespread attention due to its advantages of high sensitivity and high integration. This letter presents a broadband right-hand circularly polarized (RHCP) enhance ment resonator with unidirectional receiving beam. It can be combined with RFP to enhance the detection sensitivity of the Rydberg atomic receiver. The experimental results demonstrate the excellent broadband CP response of the resonator, with a 3-dB axial ratio (AR) bandwidth of 180 MHz. Using the AC stark effect, the resonator achieves an enhancement of 25.4–28.1 dB for RHCP microwaves (MW), with an optimal AR of 2.15 dB at 2.32 GHz. This designed resonator further expands the range of Rydberg atomic receivers in CP and directional reception applications.

DOI
10.1109/led.2026.3687863

Related papers

Frequency Reconfigurable Circularly Polarized Resonator for Quantum Microwave Sensing

Yuxiao Li, Lu Lin, Kai Yang +3 more

The Rydberg atomic receiver (RAR) has great potential for application in quantum microwave (MW) sensing due to its advantages of self-calibration and high sensitivity. However, the linearly polarized (LP) response of most RARs will reduce the sensitivity to the circularly polarized (CP) MW fields. To address this, we propose a frequency-reconfigurable CP enhancement resonator for RARs. The resonator can convert incident right-hand CP (RHCP) MW fields into LP-enhanced fields for atomic sensing. Frequency reconfiguration is achieved by adjusting the equivalent capacitance of the resonant circuit. The results show that the resonator achieves continuous frequency tuning within the range of 1.606–1.73 GHz, with an optimal axis ratio (AR) as low as 1.93 dB at 1.68 GHz. Based on the AC Stark effect, the enhancement factor (EF) for RHCP MW fields ranges from 20.2 to 24.8 dB across the reconfigurable band. This design provides key technical support for the adaptation of RARs to CP dynamic sensing scenarios.

IEEE Microwave and Wireless Technology Letters•Jan 1, 2026•0 citations

A Cascaded Cavity Resonator for Broadband Electric Field Enhancement in Rydberg Microwave Measurements

Ge Gao, Minze Chen, Aobei Chen +4 more

Rydberg atom-based microwave measurement technology has gained attention for its self-calibration, high sensitivity, and wide frequency response. To enhance sensitivity, resonators are typically employed for localized electric field enhancement. With the introduction of AC/DC Stark tuning and laser scanning techniques, resonator designs have been developed to support extended frequency coverage. However, these require sequential scanning or switching to cover the target range, limiting their applicability in passband-wide, multi-frequency detection. To address this issue, this paper proposes a cascaded cavity resonator (CCR) that enables continuous field enhancement within the target S-band range. A theoretical model was established and the key dimensions were optimized via COMSOL-based simulation of the vapor cell's spatial field distribution. Subsequently, validation through Autler-Townes (AT) effect and heterodyne technology confirms that the proposed structure enhances sensitivity by$ \geq$27.2 dB within the 2.781-3.008 GHz bandwidth. This work supports systematic exploration of Rydberg-atom response across a broader spectral range and enables multi-frequency detection without stepwise tuning.

IEEE Antennas and Wireless Propagation Letters•Oct 14, 2025•0 citations

A Compact Tunable Enhancement Resonator for Rydberg Atomic Receiver

Yuxiao Li, Yi Lin, Zhenke Ding +4 more

Rydberg atomic receivers (RARs) have emerged in the field of quantum precision measurement due to high sensitivity and self-calibration. In this letter, we demonstrate a compact tunable enhancement resonator (CTER) for enhancing the detective sensitivity of the RAR. The resonator consists of two printed circuit board (PCB) substrates and a copper tuning column, which achieves resonant frequency variation by continuously sliding the copper tuning column. During the measurement, we have achieved electric field enhancement in the 210 MHz to 308.6 MHz band with a relative bandwidth of 38$\%$and the enhancement factor ranging from 38 dB to 47 dB. By adjusting the height of the CTER, different sizes of atomic vapor cells can be accommodated while maintaining good enhancement. In theoff-resonant region, the detective sensitivity of the RAR with and without CTER at 223.7 MHz were measured at 179.37 nV$\cdot {\text{cm}}^{-1}$$ \cdot {\text{Hz}}^{-1/2}$and 40.16$\mu$V$\cdot$$\text{cm}^{-1}$$ \cdot {\text{Hz}}^{-1/2}$by utilizing the Rydberg atomic heterodyne technique, respectively. Furthermore, the CTER displays a compact electrical size, approximately 3.37× 10$^{-5}$$\lambda ^{3}$in comparison to other resonators, which facilitates the miniaturization and integration of the RAR. Its remarkable resonance characteristics and broadband tuning capability provide support for achieving high-sensitivity and broadband quantum microwave measurements.

IEEE Antennas and Wireless Propagation Letters•Dec 16, 2024•11 citations

Continuous broadband Rydberg receiver using AC Stark shifts and Floquet states

Danni Song, Yuechun Jiao, Jinlian Hu +6 more

We demonstrate the continuous broadband microwave receivers based on AC Stark shifts and Floquet states of Rydberg levels in a cesium atomic vapor cell. The resonant transition frequency of two adjacent Rydberg states 78 S1/2 and 78 P1/2 is tuned based on AC Stark effect of 70 MHz radio frequency (RF) field that is applied outside the vapor cell. The use of the j=1/2 Rydberg states ensures that only a single mj sublevel is involved. The generated Rydberg Floquet states act to enhance the sensitivity of the AC-Stark-tuned states when the frequency is matched and further extend the bandwidths. We achieve microwave field measurements with over 1.172 GHz continuous frequency tuning and a sensitivity ranging from 280.2 nVcm−1Hz−1/2 to 14.6 μ Vcm−1Hz−1/2. The achieving of continuous frequency and high sensitivity microwave detection will promote the application of Rydberg receivers in the radar technique and wireless communication.

arXiv:2407.05676•Applied Physics Letters•Nov 4, 2024•15 citations

Sensitivity of a Rydberg-atom receiver to frequency and amplitude modulation of microwaves

Sebastian Borówka, Uliana Pylypenko, Mateusz Mazelanik +1 more

Electromagnetically induced transparency in atomic systems involving Rydberg states is known to be a sensitive probe of incident microwave (MW) fields, in particular those resonant with Rydberg-to-Rydberg transitions. Here we propose an intelligible analytical model of a Rydberg atomic receiver's response to amplitude- (AM) and frequency-modulated (FM) signals and compare it with experimental results, presenting a setup that allows sending signals with either AM or FM and evaluating their efficiency with demodulation. Additionally, the setup reveals a detection configuration using all circular polarizations for optical fields and allowing detection of a circularly polarized MW field, propagating colinearly with optical beams. In our measurements, we systematically show that several parameters exhibit local optimum characteristics and then estimate these optimal parameters and working ranges, addressing the need to devise a robust Rydberg MW sensor and its operational protocol.

arXiv:2206.11829•Applied Optics•Sep 15, 2022•29 citations

Sensitivity enhancement in Rydberg atomic microwave superheterodyne measurements through laser-atom-microwave interaction mechanisms

Zhongzhou Tian, Guojin Zeng, Chao Yan +3 more

Measurement sensitivity is crucial for the practical application of Rydberg atomic microwave superheterodyne receiver systems in communication, radar, and navigation. Based on laser-atom-microwave interaction mechanisms, the influence of laser powers and local-oscillator (LO) microwave field intensity on measurement sensitivity is systematically studied in this paper. Measurement sensitivity is analyzed through electromagnetically induced transparency (EIT) spectral characteristics, specifically EIT amplitude and full-width-half-maximum (FWHM),larger amplitudes and narrower FWHM indicate improved signal-to-noise ratios. For a 60D-state Rydberg atomic system with fixed probe and coupling laser beam waists (800 µm and 875 µm), optimal parameters are determined: probe laser power of 60 µW(Rabi frequency: 2π×7.02 MHz), coupling laser power of 40 mW (Rabi frequency: 2π×0.66 MHz), and LO microwave Rabi frequency of 2π×8.34 MHz. Experimental results demonstrate a 4.6 dB sensitivity enhancement, advancing from −137.5dBm/Hz to −142.1 dBm/Hz at 3.21 GHz microwave field. This improvement is attributed to precise alignment of laser-atom and microwave-atom interactions, bridging the gap toward quantum sensitivity limits.

Applied Optics and Photonics China (AOPC)•Oct 28, 2025•0 citations
The high-efficiency Rydberg field probe (RFP), as the core of Rydberg atomic receivers, has at tracted widespread attention due to its advantages of high sensitivity and high integration. This letter presents a broadband right-hand circularly polarized (RHCP) enhance ment resonator with unidirectional receiving beam. It can be combined with RFP to enhance the detection sensitivity of the Rydberg atomic receiver. The experimental results demonstrate the excellent broadband CP response of the resonator, with a 3-dB axial ratio (AR) bandwidth of 180 MHz. Using the AC stark effect, the resonator achieves an enhancement of 25.4–28.1 dB for RHCP microwaves (MW), with an optimal AR of 2.15 dB at 2.32 GHz. This designed resonator further expands the range of Rydberg atomic receivers in CP and directional reception applications.
The Rydberg atomic receiver (RAR) has great potential for application in quantum microwave (MW) sensing due to its advantages of self-calibration and high sensitivity. However, the linearly polarized (LP) response of most RARs will reduce the sensitivity to the circularly polarized (CP) MW fields. To address this, we propose a frequency-reconfigurable CP enhancement resonator for RARs. The resonator can convert incident right-hand CP (RHCP) MW fields into LP-enhanced fields for atomic sensing. Frequency reconfiguration is achieved by adjusting the equivalent capacitance of the resonant circuit. The results show that the resonator achieves continuous frequency tuning within the range of 1.606–1.73 GHz, with an optimal axis ratio (AR) as low as 1.93 dB at 1.68 GHz. Based on the AC Stark effect, the enhancement factor (EF) for RHCP MW fields ranges from 20.2 to 24.8 dB across the reconfigurable band. This design provides key technical support for the adaptation of RARs to CP dynamic sensing scenarios.
Rydberg atom-based microwave measurement technology has gained attention for its self-calibration, high sensitivity, and wide frequency response. To enhance sensitivity, resonators are typically employed for localized electric field enhancement. With the introduction of AC/DC Stark tuning and laser scanning techniques, resonator designs have been developed to support extended frequency coverage. However, these require sequential scanning or switching to cover the target range, limiting their applicability in passband-wide, multi-frequency detection. To address this issue, this paper proposes a cascaded cavity resonator (CCR) that enables continuous field enhancement within the target S-band range. A theoretical model was established and the key dimensions were optimized via COMSOL-based simulation of the vapor cell's spatial field distribution. Subsequently, validation through Autler-Townes (AT) effect and heterodyne technology confirms that the proposed structure enhances sensitivity by$ \geq$27.2 dB within the 2.781-3.008 GHz bandwidth. This work supports systematic exploration of Rydberg-atom response across a broader spectral range and enables multi-frequency detection without stepwise tuning.
Rydberg atomic receivers (RARs) have emerged in the field of quantum precision measurement due to high sensitivity and self-calibration. In this letter, we demonstrate a compact tunable enhancement resonator (CTER) for enhancing the detective sensitivity of the RAR. The resonator consists of two printed circuit board (PCB) substrates and a copper tuning column, which achieves resonant frequency variation by continuously sliding the copper tuning column. During the measurement, we have achieved electric field enhancement in the 210 MHz to 308.6 MHz band with a relative bandwidth of 38%\%%and the enhancement factor ranging from 38 dB to 47 dB. By adjusting the height of the CTER, different sizes of atomic vapor cells can be accommodated while maintaining good enhancement. In theoff-resonant region, the detective sensitivity of the RAR with and without CTER at 223.7 MHz were measured at 179.37 nV⋅cm−1\cdot {\text{cm}}^{-1}⋅cm−1$ \cdot {\text{Hz}}^{-1/2}and40.16and 40.16and40.16\muVVV\cdotcm−1\text{cm}^{-1}cm−1 \cdot {\text{Hz}}^{-1/2}byutilizingtheRydbergatomicheterodynetechnique,respectively.Furthermore,theCTERdisplaysacompactelectricalsize,approximately3.37×10by utilizing the Rydberg atomic heterodyne technique, respectively. Furthermore, the CTER displays a compact electrical size, approximately 3.37× 10byutilizingtheRydbergatomicheterodynetechnique,respectively.Furthermore,theCTERdisplaysacompactelectricalsize,approximately3.37×10^{-5}$λ3\lambda ^{3}λ3in comparison to other resonators, which facilitates the miniaturization and integration of the RAR. Its remarkable resonance characteristics and broadband tuning capability provide support for achieving high-sensitivity and broadband quantum microwave measurements.
We demonstrate the continuous broadband microwave receivers based on AC Stark shifts and Floquet states of Rydberg levels in a cesium atomic vapor cell. The resonant transition frequency of two adjacent Rydberg states 78 S1/2 and 78 P1/2 is tuned based on AC Stark effect of 70 MHz radio frequency (RF) field that is applied outside the vapor cell. The use of the j=1/2 Rydberg states ensures that only a single mj sublevel is involved. The generated Rydberg Floquet states act to enhance the sensitivity of the AC-Stark-tuned states when the frequency is matched and further extend the bandwidths. We achieve microwave field measurements with over 1.172 GHz continuous frequency tuning and a sensitivity ranging from 280.2 nVcm−1Hz−1/2 to 14.6 μ Vcm−1Hz−1/2. The achieving of continuous frequency and high sensitivity microwave detection will promote the application of Rydberg receivers in the radar technique and wireless communication.
Electromagnetically induced transparency in atomic systems involving Rydberg states is known to be a sensitive probe of incident microwave (MW) fields, in particular those resonant with Rydberg-to-Rydberg transitions. Here we propose an intelligible analytical model of a Rydberg atomic receiver's response to amplitude- (AM) and frequency-modulated (FM) signals and compare it with experimental results, presenting a setup that allows sending signals with either AM or FM and evaluating their efficiency with demodulation. Additionally, the setup reveals a detection configuration using all circular polarizations for optical fields and allowing detection of a circularly polarized MW field, propagating colinearly with optical beams. In our measurements, we systematically show that several parameters exhibit local optimum characteristics and then estimate these optimal parameters and working ranges, addressing the need to devise a robust Rydberg MW sensor and its operational protocol.
Measurement sensitivity is crucial for the practical application of Rydberg atomic microwave superheterodyne receiver systems in communication, radar, and navigation. Based on laser-atom-microwave interaction mechanisms, the influence of laser powers and local-oscillator (LO) microwave field intensity on measurement sensitivity is systematically studied in this paper. Measurement sensitivity is analyzed through electromagnetically induced transparency (EIT) spectral characteristics, specifically EIT amplitude and full-width-half-maximum (FWHM),larger amplitudes and narrower FWHM indicate improved signal-to-noise ratios. For a 60D-state Rydberg atomic system with fixed probe and coupling laser beam waists (800 µm and 875 µm), optimal parameters are determined: probe laser power of 60 µW(Rabi frequency: 2π×7.02 MHz), coupling laser power of 40 mW (Rabi frequency: 2π×0.66 MHz), and LO microwave Rabi frequency of 2π×8.34 MHz. Experimental results demonstrate a 4.6 dB sensitivity enhancement, advancing from −137.5dBm/Hz to −142.1 dBm/Hz at 3.21 GHz microwave field. This improvement is attributed to precise alignment of laser-atom and microwave-atom interactions, bridging the gap toward quantum sensitivity limits.