Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Phase-Invariant Condition for Optimal Feedforward in ZZ-Coupled Quantum Systems: Experimental Validation on IBM Heron r2 and IQM Garnet

Takeshi Okuda

Published Apr 15, 2026• 0 citations
Publisher

Abstract

WITHDRAWN (v1.1, November 2026). The main claim of this preprint — that πνZZτ* ≈ 0.873 rad is an observed invariant across IBM and IQM superconducting devices — is withdrawn by the author. 0.873 was an input, not an observation. In every IBM run (2026-03-28 to 04-19) the delay was set to τ = 0.873/(πνZZ) from the measured νZZ before execution; πνZZτ recomputed from the run logs is 0.8730 for every run, so the constancy in Table 1 holds by construction. Table 1 mixes values from different sessions and experiments. Only the Q13–Q14 row matches a logged run at the listed τ*; other rows match a calibration-file plan or Bell-clock results at other delays. The reported GPS is not the quantity defined in the paper. The logged value for Q13–Q14 (+0.199) is Fff − Fstatic from a dynamic mid-circuit-measurement protocol, not Pff − Pref for the static circuit described. Pair selection. Eight IBM pairs were run; four are reported. IQM. The raw IQM scans (2026-04-14/15) give GPS at τ = 7 µs of −0.006 ± 0.007 (all 18 values); the tabulated +0.026 ± 0.011 (n = 5) could not be reproduced. No IQM optimum is supported. The measurements remain available as records of GPS at the set operating point πνZZτ = 0.873; they do not test whether this point is optimal. The derivation φ*ff = arg⟨eiφ⟩ (Sec. 2) is unaffected. The PDF contains the withdrawal notice followed by the original text unchanged.

DOI
10.5281/zenodo.19593676

Related papers

Quantum-6502: A Self-Calibrating Quantum BIOS with Universal Pair Discovery and Cross-Backend Validation on IBM Heron r2

Takeshi Okuda

AbstractWe present Quantum-6502, a self-calibrating BIOS layer for Entanglement-Enhanced Dynamical Tracking (EEDT) based phase-storage on IBM Heron r2 superconducting processors. EEDT is a proof-of-concept phase-storage protocol that demonstrates how always-on ZZ coupling can be converted into a feedforward resource via mid-circuit measurement (MCM), rather than suppressed. Key Features of Quantum-6502 BIOS:Universal Pair Discovery (Layer 0): Automatically discovers suitable qubit pairs from backend calibration data using zero quantum jobs.Ultra-Light Calibration (ULC): Measures νZZ and T2 using only 2 jobs (9 circuits).Adaptive Execution: Executes QFEED+ adaptive feedforward to compensate for per-session drift without user intervention. Hardware Validation Results:Static vs. Dynamic Contrast: On ibm_kingston (Q149+Q150), the system yielded GPS_dynamic = +0.345 ± 0.007 versus GPS_static = −0.201 (Δ = +0.546, z = 47.96σ), assuming shot-level independence with binomial standard error. This contrast provides strong direct evidence consistent with the stochastic collapse-timing mechanism of EEDT.Cross-Backend Consistency: Validation on ibm_marrakesh confirms GPS = +0.037 (z = 8.5σ combined, 8 Holm-corrected conditions) and GPS = +0.726 (z = 66σ).Expanded Operating Regime: The kingston result extends the confirmed operating regime to ωZZT2 = 21.9. Based on the data, τ*/TMCM ≥ 5 is tentatively proposed as the operative constraint, ensuring that measurement overhead remains subdominant to coherent evolution.Robustness: Sensitivity analysis confirms that EEDT gain remains positive (GPS > 0) across a ±30% variance (covering observed drift ranges) from the MANUAL calibration estimate of νZZ. Consistency with AUTO-mode estimates (where available) indicates no systematic bias introduced by the MANUAL override. AvailabilityThe present validation is restricted to IBM Heron r2. All system code, raw experimental data, and IBM Quantum job IDs are publicly available in the linked repository.

•Mar 22, 2026•0 citations

Automatic calibration of arrays of superconducting qubits and couplers

Kevin J. Satzinger, Brooks Foxen, B. Chiaro +2 more

Bulletin of the American Physical Society•Mar 4, 2019•0 citations

Bell Decay Clock: Extracting Useful Information from Decoherence via Mid-Circuit Measurement Feedforward

Takeshi Okuda

A feedforward protocol that converts decoherence into an information resource for quantum control. The Bell Decay Clock encodes timing information in measurement-resolved decay pathways of entangled states, enabling mid-circuit measurement (MCM) to extract useful classical information even after phase coherence is lost. Key results:- IBM Heron: Bell clock maintains GPS > 0 over 3-4x wider window than ZZ clock (18/18 points, z > 5σ)- IQM Garnet: ZZ clock fails completely (GPS < 0, all points), Bell clock succeeds (GPS = +0.19, 4.4σ)- Static vs Dynamic control: ΔGPS = +0.55 isolates MCM feedback as active mechanism- Universal feedforward phase ϕ* = 0.873 rad verified across 3 independent qubit pairs Related: EEDT protocol (DOI: 10.5281/zenodo.19029431)Code: https://github.com/okudat9/Quantum-6502

•Apr 1, 2026•0 citations

Optimal experiment design for parameter estimation as applied to dipole- and exchange-coupled qubits

Kevin C Young, Mohan Sarovar, K. Birgitta Whaley +1 more

APS•Mar 1, 2009•0 citations

Echo Timing and Phase Response on IBM Fez: Two Acquisitions with Reproducible Analysis

Jonathan chadbourne

Two acquisitions on physical qubit 0 of IBM Fez examine Ramsey, centered Hahn-echo and pre-idle phaseresponse, followed by asymmetric echo placement. WAVE002 (November 6, 2026) contains 416 circuits and53,248 shots. WAVE003 (November 14, 2026) contains 240 circuits and 61,440 shots. Centered echo exceededRamsey at the WAVE002 8-microsecond anchor and exceeded both quarter- and three-quarter-position echoesat both tested WAVE003 holds. The main contrasts survive a publication-level simultaneous uncertaintyallocation across both studies, conditional on independent bounded shots The supplement supplies recorded shots and counts, frozen analyzers, circuit inventories and readable instructions, archived results, offline replay and labeled exploratory model comparisons. The original WAVE002 sparse-count failure and its lossless correction are preserved. The acquisitions are complementary, not identical independent replications. Physical shot independence, pulse timing and chronological execution were not independently attested. An uncertainty-aware absolute-response comparison finds conventional quasi-static and slow finite-correlation models compatible with all pooled gain coordinates. An unsuccessful retrospective point forecast is preserved alongside its broad training-only uncertainty. No unexplained anomaly, technological improvement, unique noise mechanism, calibrated memory fidelity or new echo method is established. AI assistance is disclosed. This is a preprint, not a claim of peer review or journal acceptance.

•Nov 14, 2026•0 citations

Study of junction and bias parameters in readout of phase qubits

Hesam Zandi, Shabnam Safaei, Sina Ataollah Khorasani +1 more

arXiv:0911.0850•Physica C Superconductivity•May 12, 2011•4 citations
WITHDRAWN (v1.1, November 2026). The main claim of this preprint — that πνZZτ* ≈ 0.873 rad is an observed invariant across IBM and IQM superconducting devices — is withdrawn by the author. 0.873 was an input, not an observation. In every IBM run (2026-03-28 to 04-19) the delay was set to τ = 0.873/(πνZZ) from the measured νZZ before execution; πνZZτ recomputed from the run logs is 0.8730 for every run, so the constancy in Table 1 holds by construction. Table 1 mixes values from different sessions and experiments. Only the Q13–Q14 row matches a logged run at the listed τ*; other rows match a calibration-file plan or Bell-clock results at other delays. The reported GPS is not the quantity defined in the paper. The logged value for Q13–Q14 (+0.199) is Fff − Fstatic from a dynamic mid-circuit-measurement protocol, not Pff − Pref for the static circuit described. Pair selection. Eight IBM pairs were run; four are reported. IQM. The raw IQM scans (2026-04-14/15) give GPS at τ = 7 µs of −0.006 ± 0.007 (all 18 values); the tabulated +0.026 ± 0.011 (n = 5) could not be reproduced. No IQM optimum is supported. The measurements remain available as records of GPS at the set operating point πνZZτ = 0.873; they do not test whether this point is optimal. The derivation φ*ff = arg⟨eiφ⟩ (Sec. 2) is unaffected. The PDF contains the withdrawal notice followed by the original text unchanged.
AbstractWe present Quantum-6502, a self-calibrating BIOS layer for Entanglement-Enhanced Dynamical Tracking (EEDT) based phase-storage on IBM Heron r2 superconducting processors. EEDT is a proof-of-concept phase-storage protocol that demonstrates how always-on ZZ coupling can be converted into a feedforward resource via mid-circuit measurement (MCM), rather than suppressed. Key Features of Quantum-6502 BIOS:Universal Pair Discovery (Layer 0): Automatically discovers suitable qubit pairs from backend calibration data using zero quantum jobs.Ultra-Light Calibration (ULC): Measures νZZ and T2 using only 2 jobs (9 circuits).Adaptive Execution: Executes QFEED+ adaptive feedforward to compensate for per-session drift without user intervention. Hardware Validation Results:Static vs. Dynamic Contrast: On ibm_kingston (Q149+Q150), the system yielded GPS_dynamic = +0.345 ± 0.007 versus GPS_static = −0.201 (Δ = +0.546, z = 47.96σ), assuming shot-level independence with binomial standard error. This contrast provides strong direct evidence consistent with the stochastic collapse-timing mechanism of EEDT.Cross-Backend Consistency: Validation on ibm_marrakesh confirms GPS = +0.037 (z = 8.5σ combined, 8 Holm-corrected conditions) and GPS = +0.726 (z = 66σ).Expanded Operating Regime: The kingston result extends the confirmed operating regime to ωZZT2 = 21.9. Based on the data, τ*/TMCM ≥ 5 is tentatively proposed as the operative constraint, ensuring that measurement overhead remains subdominant to coherent evolution.Robustness: Sensitivity analysis confirms that EEDT gain remains positive (GPS > 0) across a ±30% variance (covering observed drift ranges) from the MANUAL calibration estimate of νZZ. Consistency with AUTO-mode estimates (where available) indicates no systematic bias introduced by the MANUAL override. AvailabilityThe present validation is restricted to IBM Heron r2. All system code, raw experimental data, and IBM Quantum job IDs are publicly available in the linked repository.
A feedforward protocol that converts decoherence into an information resource for quantum control. The Bell Decay Clock encodes timing information in measurement-resolved decay pathways of entangled states, enabling mid-circuit measurement (MCM) to extract useful classical information even after phase coherence is lost. Key results:- IBM Heron: Bell clock maintains GPS > 0 over 3-4x wider window than ZZ clock (18/18 points, z > 5σ)- IQM Garnet: ZZ clock fails completely (GPS < 0, all points), Bell clock succeeds (GPS = +0.19, 4.4σ)- Static vs Dynamic control: ΔGPS = +0.55 isolates MCM feedback as active mechanism- Universal feedforward phase ϕ* = 0.873 rad verified across 3 independent qubit pairs Related: EEDT protocol (DOI: 10.5281/zenodo.19029431)Code: https://github.com/okudat9/Quantum-6502
Two acquisitions on physical qubit 0 of IBM Fez examine Ramsey, centered Hahn-echo and pre-idle phaseresponse, followed by asymmetric echo placement. WAVE002 (November 6, 2026) contains 416 circuits and53,248 shots. WAVE003 (November 14, 2026) contains 240 circuits and 61,440 shots. Centered echo exceededRamsey at the WAVE002 8-microsecond anchor and exceeded both quarter- and three-quarter-position echoesat both tested WAVE003 holds. The main contrasts survive a publication-level simultaneous uncertaintyallocation across both studies, conditional on independent bounded shots The supplement supplies recorded shots and counts, frozen analyzers, circuit inventories and readable instructions, archived results, offline replay and labeled exploratory model comparisons. The original WAVE002 sparse-count failure and its lossless correction are preserved. The acquisitions are complementary, not identical independent replications. Physical shot independence, pulse timing and chronological execution were not independently attested. An uncertainty-aware absolute-response comparison finds conventional quasi-static and slow finite-correlation models compatible with all pooled gain coordinates. An unsuccessful retrospective point forecast is preserved alongside its broad training-only uncertainty. No unexplained anomaly, technological improvement, unique noise mechanism, calibrated memory fidelity or new echo method is established. AI assistance is disclosed. This is a preprint, not a claim of peer review or journal acceptance.