Characteristics of phase sensitive protocol “iQdyne” for diamond quantum magnetometry in wide field optics

皓介 水野, Kosuke Mizuno, 誠人 中島, M. Nakajima, 整 石綿, Hitoshi Ishiwata, 雄太 増山, Y. MASUYAMA, 孝之 岩崎, Takayuki Iwasaki, 睦子 波多野, Mutsuko Hatano

Published Mar 1, 2019• 0 citations
OpenAlex

Related papers

Phase sensitive protocol "iQdyne" for wid-field diamond magnetometry

皓介 水野, Kosuke Mizuno, 誠人 中島 +9 more

•Feb 1, 2019•0 citations

Phase sensitive quantum magnetometry imaging using emsemble NV center in diamond on wide field optics

皓介 水野, Kosuke Mizuno, 整 石綿 +7 more

•Jun 1, 2019•0 citations

Simultaneous amplitude and phase wide-field imaging of AC magnetic signal using diamond quantum magnetometry

皓介 水野, Kosuke Mizuno, 整 石綿 +7 more

•Dec 1, 2019•0 citations

Wide-field diamond magnetometry with millihertz frequency resolution and nanotesla sensitivity

Kosuke Mizuno, Makoto Nakajima, Hitoshi Ishiwata +3 more

Wide-field quantum magnetometry using nitrogen-vacancy (NV) center in diamond can be a breakthrough for a nuclear magnetic resonance (NMR) in a small volume, which is important for biological applications. Although the coherence time of the electron spin of the NV center results in a limited frequency resolution for diamond magnetometry in the range 10–100 kHz, recent studies have shown that a phase-sensitive protocol can circumvent this limit using a confocal setup. We proposed a new measurement protocol, “iQdyne,” which facilitates an improved frequency resolution of wide-field imaging, unencumbered by the coherence limit imposed by the NV center. We demonstrated wide-field magnetometry with a frequency resolution of 238 mHz and a magnetic sensitivity of 65 nT/Hz1/2, which are superior to those obtained using a conventional XY8-based technique, and showed the potential of the iQdyne protocol for the wide-field NMR imaging.

arXiv:1807.04444•AIP Advances•Dec 1, 2018•19 citations

Development of highly sensitive diamond quantum magnetometer using photonic structures

晃佑 髙田

•Mar 24, 2026•0 citations

Optimized Diamond Development for Quantum Vector Magnetometry

John F. Barry, Xingyu Zhang, Linh Pham +3 more

IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)•Apr 1, 2019•0 citations
Wide-field quantum magnetometry using nitrogen-vacancy (NV) center in diamond can be a breakthrough for a nuclear magnetic resonance (NMR) in a small volume, which is important for biological applications. Although the coherence time of the electron spin of the NV center results in a limited frequency resolution for diamond magnetometry in the range 10–100 kHz, recent studies have shown that a phase-sensitive protocol can circumvent this limit using a confocal setup. We proposed a new measurement protocol, “iQdyne,” which facilitates an improved frequency resolution of wide-field imaging, unencumbered by the coherence limit imposed by the NV center. We demonstrated wide-field magnetometry with a frequency resolution of 238 mHz and a magnetic sensitivity of 65 nT/Hz1/2, which are superior to those obtained using a conventional XY8-based technique, and showed the potential of the iQdyne protocol for the wide-field NMR imaging.