Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) on Development of Innovative Sensor Systems by Highly Sophisticated Control of Solid Quantum Sensors

睦子 波多野, Mutsuko Hatano

Published Dec 1, 2020• 0 citations
OpenAlex

Related papers

Current Status and Prospects of Solid-State Quantum Sensors for Quantum-LEAP

睦子 波多野, Mutsuko Hatano

•Dec 1, 2021•0 citations

JST and MEXT SFQ Device Projects -- For New Innovation of SFQ Electronics

Fujimaki Akira

IEICE Technical Report; IEICE Tech. Rep.•Oct 23, 2008•0 citations

Quantum Technologies—Quantum Sensors and Quantum Imaging Systems

Woon Siong Gan

Springer eBooks•Jan 1, 2022•0 citations

Highly sensitive diamond quantum sensor with large sensor volume toward magnetoencephalography

雄太 増山, Takayuki Iwasaki, 睦子 波多野 +4 more

Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.

•Dec 4, 2019•0 citations

Optimization of digital filtering detection with frequency modulation for portable sensitive quantum magnetometer

雄太 増山, Takayuki Iwasaki, Mutsuko Hatano +3 more

Introduction Nitrogen-vacancy (NV) centers in diamond are promising solid-state quantum sensors. The sensor can potentially monitor the real-time magnetic field at room-temperature toward the brain-machine interface. One of the biggest challenges is to implement a highly sensitive sensor in a compact system. There are two major ways to achieve it. An analog signal processing method with a lock-in amplifier is fast to obtain the signal, but it increases the size of the sensor system. The digital signal processing method with the Fourier transform is simple, but it needs more computational resources. Reducing computational resources with the simple system is an important task for monitoring a real-time magnetic field. In this study, we demonstrate an alternative method of digital signal processing with less computational resources than the Fourier transform. The computational time of the method to compute the signal from n points of data is O(n), whereas the time with Fourier transform is O(n log n). Method and Result We confirm our method with a large detection volume of the ensemble NV centers. The microwave and optical systems used in our experiment are shown in Fig. 1. The diamond sample containing NV centers was placed between the microwave resonator and a compound parabolic concentrator1. We used a coplanar waveguide resonator (CWR) with a wide center electrode for strong and uniform microwave irradiation2. The power of microwave with frequency modulation is 25 dBm before the CWR. The 300 mW laser beam to the diamond was focused with a beam diameter of about 30 μm. The fluorescence from the NV centers was collected through the compound parabolic concentrator and detected using a photodiode. The detected signal of the photodiode is analyzed by digital signal processing. The method obtains the result using a digital filter that effectively becomes a sinc filter using the orthogonality of trigonometric functions by multiplication of the acquired data by a trigonometric function. Figures 2 shows continuous-wave optical detected magnetic resonance (CW-ODMR) spectrum using the digital signal processing with a different modulation frequency of the microwave. The maximum slope and the noise of the signal become smaller with increasing the modulation frequency for different reasons. The low transition rate between quantum states of the NV center reduces the maximum slope for high modulation frequency. While the noise becomes smaller for high modulation frequency. We evaluate the maximum signal slope (Fig. 3) and noise level of the spectrum (Fig. 4). We found the reduction of the noise is greater than the reduction of the maximum slope. This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.

•Dec 17, 2019•0 citations

The Quantum Leap: Unleashing Quantum Computing for Next-Generation Renewable Energy Optimization and Applications

Vennapusa Mahesh Kumar Reddy, Gurrampati Sreenivasula, G. K. D. Prasanna Venkatesan

Algorithms for intelligent systems•Aug 2, 2026•0 citations
Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.
Introduction Nitrogen-vacancy (NV) centers in diamond are promising solid-state quantum sensors. The sensor can potentially monitor the real-time magnetic field at room-temperature toward the brain-machine interface. One of the biggest challenges is to implement a highly sensitive sensor in a compact system. There are two major ways to achieve it. An analog signal processing method with a lock-in amplifier is fast to obtain the signal, but it increases the size of the sensor system. The digital signal processing method with the Fourier transform is simple, but it needs more computational resources. Reducing computational resources with the simple system is an important task for monitoring a real-time magnetic field. In this study, we demonstrate an alternative method of digital signal processing with less computational resources than the Fourier transform. The computational time of the method to compute the signal from n points of data is O(n), whereas the time with Fourier transform is O(n log n). Method and Result We confirm our method with a large detection volume of the ensemble NV centers. The microwave and optical systems used in our experiment are shown in Fig. 1. The diamond sample containing NV centers was placed between the microwave resonator and a compound parabolic concentrator1. We used a coplanar waveguide resonator (CWR) with a wide center electrode for strong and uniform microwave irradiation2. The power of microwave with frequency modulation is 25 dBm before the CWR. The 300 mW laser beam to the diamond was focused with a beam diameter of about 30 μm. The fluorescence from the NV centers was collected through the compound parabolic concentrator and detected using a photodiode. The detected signal of the photodiode is analyzed by digital signal processing. The method obtains the result using a digital filter that effectively becomes a sinc filter using the orthogonality of trigonometric functions by multiplication of the acquired data by a trigonometric function. Figures 2 shows continuous-wave optical detected magnetic resonance (CW-ODMR) spectrum using the digital signal processing with a different modulation frequency of the microwave. The maximum slope and the noise of the signal become smaller with increasing the modulation frequency for different reasons. The low transition rate between quantum states of the NV center reduces the maximum slope for high modulation frequency. While the noise becomes smaller for high modulation frequency. We evaluate the maximum signal slope (Fig. 3) and noise level of the spectrum (Fig. 4). We found the reduction of the noise is greater than the reduction of the maximum slope. This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.